Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹8.3 LAccepted-AOC GS 15 SAGARTA COMPLEX LUMBANI NAGAR MIDC HIGNA ROAD NAGPUR 440016 MAHARASHTRA | NAGPUR | NAGPUR | MAHARASHTRA | 440016 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹11.4 L+₹3.1 L (37.4%)Rejected-AOC | L-2 | Rejected-AOC Being L-2 |
Tender Value
₹9.7 L
EMD Value
₹24,400
Closing Date
4 Nov 2019, 3:00 pmClosed
SE PNW
O/o CE Gen Sarni
Repairing,Erection,commissioning of left out components and load test of various PBL make EOT Crane installed in Boiler Unit No.10 and 11STPS,Sarni.
2019_MPPGC_37698_1
WT2821
Open Tender
Miscellaneous Works
Item Wise
90 days
sarni
as per NIT
4 documents required · 4 mandatory
₹500
Yes
Payable To
₹24,400
Yes
22 Sept 2021
27 Aug 2019
6 Nov 2019
27 Aug 2019
4 Nov 2019
27 Aug 2019
Repairing,Erection,Commissioning of left out/missing components& Load Test including supply of spares of various PBL make EOT Crane/Hoists installed in Boiler Unit No.10 &11 STPS,Sarni
Repairing, Erection of left out/missing components, commissioning, Load test & provide necessary load test certificate from competent authority of existing pressure part Coil handling system/EOT crane at Unit NO. 10, which includes. A. Supply & replacement /installation of required contractors, pendent push button along with required length of cable (12 Core x 1.5 Sq. mm), power & control cables, limit switch for up & down, CT limit Switches, counter weight limit switches, 63 AMP MCB & all other missing / damaged component. B. Supply and Installation of pendent pushbutton along with required length of cable. C. Checking & repairing of CT & main Motor if required. D. Repair of Brakes & replacement if required. E. Any other work/material required for successful commissioning & proper working. Specification :PBL make EOT Crane 5 MT Capacity
Repairing, Erection of left out/missing components, commissioning, Load test & provide necessary load test certificate from competent authority of existing Hoist at FD Fan Unit No. 10 B (ROTOR Handling System) which includes. A. Checking / repairing of Brakes & replacement if required. B. Supply and installment of limit switches of CT & main Hoists. C. Checking & repairing of CT & main Motor if required. D. Supply and replacement of all damaged / missing component required for successful commissioning & proper working Specification :PBL make Hoist 2 MT Capacity
Repairing, Erection of left out/missing components, commissioning, Load test & provide necessary load test certificate from competent authority of existing hoist at FD Fan Unit No.10 A (ROTOR Handling System) which includes. A. Checking / repairing of Brakes & replacement if required. B. Checking & repairing of CT & main Motor if required. C. Supply and installment of limit switches of CT & main hoist. D. Supply and replacement of all damaged / missing components required for successful commissioning & proper working. Specification :PBL make Hoist 2 MT Capacity
Repairing, Erection of left out/missing components, commissioning, Load test & provide necessary load test certificate from competent authority of existing pressure part Coil handling system/EOT Crane at Unit NO. 11, which includes. A. Supply & replacement /installation of required contractors, pendent push button along with required length of cable (12 Core x 1.5 Sq. mm), power & control cables, limit switch for up & down, CT limit Switches, counter weight limit switches, 63 AMP MCB & all other missing / damaged component. B. Supply Installation of pendent push button along with required length of cable. C. Checking & repairing of CT & main Motor if required. D. Repairing of Brakes & replacement if required. E. Supply and replacement of all damaged / missing Components required for successful commissioning & proper working. Specification:PBL make EOT Crane 5 MT Capacity
Repairing, Erection of left out/missing components, commissioning, Load test & provide necessary load test certificate from competent authority of existing Hoist at APH at Unit No. 11 (Basket handling system) which includes. A. Checking / repairing of Brakes & replacement if Required. B. Supply and installment of limit switches of CT & main Hoists. C. Supply Installation of pendent push button along with required length of cable. D. Checking & repairing of CT & main Motor if required. E. Supply, installation of Wire Rope of required size length approximate 150 mtr. Specification:PBL make Hoist 1 MT Capacity
Repairing, Erection of left out/missing components, commissioning, Load test & provide necessary load test certificate from competent authority of existing Hoist at PA Fan at Unit No. 11 A (ROTOR Handling System) which includes. A. Checking / repairing of Brakes & replacement if Required. B. Supply and installation of limit switches of CT & main Hoist. C. Checking & repairing of CT& main Motor, if required. D. Supply and replacement of all damaged / missing component required for successful commissioning & proper working. Specification:PBL make Hoist 5 MT Capacity
Repairing, Erection of left out/missing components, commissioning, Load test & provide necessary load test certificate from competent authority of existing Hoist at FD Fan Unit No. 11B (ROTOR Handling System) which includes. A. Checking / repairing of Brakes & replacement if Required. B. Supply and installment of limit switches of CT & main Hoist. C. Checking & repairing of CT & main Motor if required. Specification:PBL make Hoist 2 MT Capacity
JAY TECHNICAL SERVICES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .