Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | ₹8.7 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L1₹18.5 LAccepted-AOC 59 WELKAR HOUSE C P TANK ROAD C P TANK AREA MUMBAI MAHARASHTRA 400004 | MUMBAI | MAHARASHTRA | 400004 | ₹18.5 L | L1 | Accepted-AOC L1 Bidder |
| 3 | L1₹44.1 LAccepted-AOC 102 104 2ND FLOOR PRAVIN HOUSE 1ST PATHAN STREET 4TH KUMBHARWADA NEAR MOTI TALKIES MUMBAI MAHARASHTRA 400004 | MUMBAI | MAHARASHTRA | 400004 | ₹44.1 L | L1 | Accepted-AOC L1 Bidder |
| 4 | L1₹54.1 LAccepted-AOC A 1 UPSIDC INDUSTRIAL AREA NANDGAON ROAD KOSI KALAN KOSI KALAN DISTRICT MATHURA MATHURA UTTAR PRADESH 281403 | MATHURA | UTTAR PRADESH | 281403 | ₹54.1 L | L1 | Accepted-AOC L1 Bidder |
| 5 | L1₹2.8 CrAccepted-AOC 17 RAJMUGAT SOCIETY NARANPURA CROSS ROAD NARANPURA NARANPURA AHMEDABAD GUJARAT 380013 | AHMADABAD | GUJARAT | 380013 | ₹2.8 Cr | L1 | Accepted-AOC L1 Bidder |
Tender Value
Refer Docs
Closing Date
1 Sept 2022, 3:00 pmClosed
Mr. Nilesh Sathe
thyssenKrupp Industrial Solutions (India) Private Limited (Formerly Uhde India Private Limited) Uhde House, L B S Marg, Vikhroli (W), Mumbai - 400083, India
SUPPLY OF PIPES-WELDED- SS and AS FOR P25 PROJECT AT IOCL PANIPAT REFINERY
2022_REFHQ_154854_1
6745-PPM-000-CA-PI35
Limited
Mechanical - Piping, materials, flanges, valves, seals
Tender cum Auction
120 days
IOCL Panipat Refinery
Please refer Tender documents.
6 documents required · 6 mandatory
Exempted
23 Jan 2025
9 Aug 2022
2 Sept 2022
9 Aug 2022
1 Sept 2022
25 Aug 2022
SUPPLY OF PIPES -SS WELDED TO A 358
PIPE,EFW,SS,DUAL, B36.19M, BW ENDS,SCH 80S, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A358 TP304/304L CL.1, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SUPPLY OF PIPE-WELDED ALLOY STEEL
PIPE,EFW,AS, B36.10M, BW ENDS,SCH XS, EFW, NORMALIZED & TEMPERED, RADIOGRAPHY SHALL BE DONE, AFTER STRESS RELIEVING, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A691 Gr.5CR CL.42, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,AS, B36.10M, BW ENDS,SCH XS, EFW, NORMALIZED & TEMPERED, RADIOGRAPHY SHALL BE DONE, AFTER STRESS RELIEVING, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A691 Gr.5CR CL.42, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,AS, B36.10M, BW ENDS,SCH NON-STD, EFW, NORMALIZED & TEMPERED, RADIOGRAPHY SHALL BE DONE, AFTER STRESS RELIEVING, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A691 Gr.5CR CL.42, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,AS, B36.10M, BW ENDS,SCH NON-STD, EFW, NORMALIZED & TEMPERED, RADIOGRAPHY SHALL BE DONE, AFTER STRESS RELIEVING, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A691 Gr.5CR CL.42, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,AS, B36.10M, BW ENDS,SCH NON-STD, EFW, NORMALIZED & TEMPERED, RADIOGRAPHY SHALL BE DONE, AFTER STRESS RELIEVING, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A691 Gr.5CR CL.42, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,AS, B36.10M, BW ENDS,SCH XS, EFW, NORMALIZED & TEMPERED, RADIOGRAPHY SHALL BE DONE, AFTER STRESS RELIEVING, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A691 Gr.9CR CL.42, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,AS (H2 SER.), B36.10M, BW ENDS,SCH 30, EFW, NORMALIZED & TEMPERED, RADIOGRAPHY SHALL BE DONE, AFTER STRESS RELIEVING, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A691 Gr.1 1/4CR CL42, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
PIPE,EFW,AS (H2 SER.), B36.10M, BW ENDS,SCH XS, EFW, NORMALIZED & TEMPERED, RADIOGRAPHY SHALL BE DONE, AFTER STRESS RELIEVING, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A691 Gr.1 1/4CR CL42, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
PIPE,EFW,AS (H2 SER.), B36.10M, BW ENDS,SCH NON-STD, EFW, NORMALIZED & TEMPERED, RADIOGRAPHY SHALL BE DONE, AFTER STRESS RELIEVING, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A691 Gr.1 1/4CR CL42, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
HI TECH METAL AND TUBES
Jindal Saw Limited (Semless Div.)
RATNAMANI METALS AND TUBES LIMITED
stage.html
html • 0.08 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .