Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 213 BAHARTI NAGAR SUBASH NAGAR JAMMU JAMMU JAMMU JAMMU KASHMIR 180007 | JAMMU | JAMMU AND KASHMIR | 180007 | Admitted-Finance |
| 2 | Admitted-Finance JAMMU AND KASHMIR JAMMU AND KASHMIR | JAMMU | JAMMU AND KASHMIR | 181122 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical H NO 92 LANE NO 17 HARI NAGAR TALAB TILLO JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | Rejected-Technical NON-RESPONSIVE |
Tender Value
₹5.4 L
EMD Value
₹11,000
Closing Date
12 Aug 2022, 2:00 pmClosed
DY. GENERAL MANAGER
Office of the Deputy General Manager, JKPCC Ltd., Unit Electrical, Rail Head Complex Jammu.
Renovation of Electrical Distribution System at JKRRI Complex Janipur, Jammu.
2022_PWDJK_180184_1
e-NIT No. 12/ELECT of 2022-23 Dt. 20-07-2022.
Open Tender
Electrical Works
Item Rate
30 days
JAMMU
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
Financial Controller, JKPCC Ltd.
₹11,000
Yes
Dy. Gen. Mgr. Elect. Unit JKPCC Jammu.
24 Aug 2022
21 Jul 2022
12 Aug 2022
21 Jul 2022
12 Aug 2022
22 Jul 2022
26 Jul 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group C)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Supplying and fixing of following rating 240 Volts "C" Series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning. (Make as per annexure enclosed).
Triple Pole and Neutral 63/50 Amp.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supply of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade 0f following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.3.5 core 70 sq. mm armoured.
Supply of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade 0f following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.3.5 core 25 sq. mm armoured.
Supply of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade 0f following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.3.5 core 35 sq. mm armoured.
Supply of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade 0f following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 4 core 16 sq. mm armoured.
laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq.mm
laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 95sqmm. and upto 185 sqmm.
Busbar (Outdoor Type) :Providing/ Installation/ Testing and Commissioning of cubical type main panel board from high quality 14 SWG 2mm thickness CRCA sheet angle/ Flat iron mounted with hinged lockable front door with din bar in separate compartment painted with powder coated conforming with PWD specification P-IV sub station work along with 3-phase and neutral aluminium bus bar of suitable length and rating.
ROYAL ENGINEERS AND CONTRACTORS
SUNIL KUMAR SURI CONTRACTOR
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .