Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹14.4 L+₹17,726 (1.25%)Rejected-AOC MILITARY HOSPITAL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹15.9 L+₹1.6 L (11.6%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹17.1 L+₹2.9 L (20.6%)Rejected-AOC NEW HOSPITAL ROAD UDHAMPUR UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹17.3 L+₹3.1 L (21.9%)Rejected-AOC 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
24 May 2021, 6:00 pmClosed
SHUBHAM PARKASH
GE NORTH UDH
REPAIR REPLACEMENT OF ALUMINIUM WIRING INCLUDING INTERNAL FITTINGS AND FIXTURES AND OTHER CONNECTED WORKS OF ASC SUPPLY FPD WEU HQ DDGSI AND SUB AREA OFFICERS MESS UNDER GEN UDHAMPUR
2021_MES_438831_1
GE/U(N)-07/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE NORTH UDH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NORTH UDH
₹40,000
Yes
22 Jun 2021
27 Apr 2021
26 May 2021
27 Apr 2021
24 May 2021
10 May 2021
Amount
Taking down carefully the existing Copper/Aluminium point wiring of any size and type by disconnecting from the either terminals complete with switches, sockets, ceiling rose, regulators, bell etc by unscrewing and removing materials to store for keeping in safe custody for re-use or for taking credit and making good to disturb surface of walls, floors etc., complete all as specified and directed by Engr -in- charge. Note : (i) Old dismanteled wiring and accessories (other than reuse) will be contractors property and credit will be charged against schedule of credit.
Taking down carefully by unscrewing from boards / outlet boxes fittings and fixture such as, LED bulk head fitting, LED tube light fitting etc. for re use at site or carrying to the store (serviceable fitting shall be reuse) all as specified and as directed by engineer in charge.
Taking down Old Serviceable/unserviceable MCB DB any type/size etc after disconnecting (serviceable DBs /MCBs shall be reuse), complete all as specified and directed by engineer in charge.
M&L for Point wiring for One light point controlled by one one way switch 5 Amp with 1.5 Sqmm single core multi standed copper conductor FRLSH insulated and unsheathed heavy duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated drawn into and including concealed PVC rigid conduit of not less than 20mm dia and1.5mm wall thickness ISI marked terminated into annealed steel terminal boxes including 3.00 mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and directed by the Engr-in-charge.
M&L for point wiring with 1.5 Sq. mm PVC Insulated unsheathed FRLSH multistranded copper conductor, medium grade ISI meraked drwan into and including PVC concealed conduit with all accessories from terminal box to junction of ceiling and wall and rest of circuit conductor wire drwan in to and including suraface PVC rigid non metalic conduit for one ceiling fan point controlled by one switch with and also including 1.5 sqmm continious earth wire connected to common earth dolly complete all as specified and directed by engineer incharge.
All as per item No. 04 above but for bell / buzzer on independent board controlled by one push button bell switch.
All as per item No. 04 above but for one 5 Amps socket outlet on independent board.
All as per item No. 04 bove but wire size 2x2.5 Sqmm to controlled the 3 pin 5 / 15 Amps socket outlet on independent board and providing earth continuity wire using PVC insulated, FRLSH 1100 volts grade un sheathed single core stranded copper conductor cable of size 2.5 Sqmm.
All as per item No. 04 above but controle by 2 Nos.of two way switch.
All as per item Srl No. 04 herein before but for 3 pin socket outlet 5 Amp on same board, complete all as specified and directed by Engr -in-charge.
M&L Point wiring with multistranded copper conductor cable, PVC insulated and unsheathed (FRLSH) size 1.5 sqmm drawn in and incl PVC casing and caping with fixing accessories, to be fixed on wooden gutties or plastic rawal plug, for one light /fan/controlled by one switch with thickness not less than 1.25mm annealed steel boxes concealed on wall with and including 3mm thick laminated backlite sheet complete all as directed by Engineer-in-charge.
All as per item No 11 above but for two way point wiring
All as per item No 11 above but for one 3/5 pin socket 5 Amp on same board.with cable1.5 sqmm size.
All as per item No 11 above but for one 3/5 pin socket 5 Amp on independent board.with cable1.5 sqmm size.
All as per item No 11 above but for 3/5 pins socket outlet 15 Amps independent with 2.5 sqmm incl continous earthing with multistandred copper conductor PVC insulated unsheathed size 2.5 Sqmm complete all as specified and directed.
All as per item No. 11 above but for bell / buzzer on independent board controlled by one push button bell switch.
S&F Switch Piano flush type single pole 5 Amps One way, all as specified and directed by Engineer- in - Charge.
S&F Switch Piano flush type single pole two way 5 Amps, all as specified and directed by Engineer- in - Charge.
S&F Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type complete all as specified and directed by Engineer- in - Charge.
S&F Switch Piano type single pole 16/20 Amps One way, complete all as specified and directed by Engineer- in - Charge.
S&F Socket outlet Two in one, 3/5 Pin piano type 10 Amp and 20 Amp flush type complete all as specified and directed by Engineer- in - Charge
S&F Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body complete all as specified and directed by Engineer - in - Charge.
S&F Electric bell (Ding dong) AC 230/250 volts grade single pole ISI marked, complete all as specified and as directed by engineer in charge
S&F switch piano flush type for bell Push 5 Amps, complete all as specified and directed by Engineer- in - Charge.
S&F Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked complete all as specified and directed by Engineer- in - Charge.
Fixing only serviceable light fittings any type as obtained against item No 2 all as specified and directed by engineer incharge
Taking down fan, ceiling cable end, dismantling blades and kept in safe custody for refixing on same location all as specified and directed by engineer in charge.
Hanging /fixing only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan obtained from item no 27
M&L Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of MES Part-1 fixed in replacement including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC Pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of Earthing. Note : (a) On testing after completion of earthing, if the desired earth resistnace is not obtained, the earthing will be done by the contractor at his own risk and cost to the entire satisfaction ot the engineer incharge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
Sub main wiring with two run single core 6 sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100V grade including 25mm dia PVC concealed conduit medium grade ISI marked with all accessories such as Tees, elbows, junctgion boxes etc, as required fixed on wall alongwith one run of 6 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continious earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable submain of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-in-charge. Note : Two run of 6 sqmm and one run 6 sqmm cable and one run of PVC conduit shall be measured as one RM
M&L in replacement for submain wiring with 2X4QMM+1X4SQMM Earth Wire single core PVC insulated FRLSH sheathed cooper cable connecting to common earth dolly in and including heavy duty PVC Concealed Conduit 25MM DIA complete including taking down userviceable submain wiring all as per site requirement and direction by EIC, all accessories complete all as specified and directed.
M&L in replacement for submain wiring with 2X1.5QMM+1X1.5SQMM Earth Wire single core PVC insulated FRLSH sheathed cooper cable connecting to common earth dolly in and including heavy duty PVC Concealed Conduit 20MM DIA complete including taking down userviceable submain wiring all as per site requirement and direction by EIC, all accessories complete all as specified and directed.
M&L in replacement for submain wiring with 2X2.5QMM+1X2.5SQMM Earth Wire single core PVC insulated FRLSH sheathed cooper cable connecting to common earth dolly in and including heavy duty PVC Concealed Conduit 20MM DIA complete including taking down userviceable submain wiring all as per site requirement and direction by EIC, all accessories complete all as specified and directed.
S&F Switch Piano flush type single pole two way 5 Amps fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F Switch Piano flush type single pole 5 Amps one way fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F switch piano flush type for bell Push 5 Amps fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F Socket outlet Two in one, 3/5 Pin piano type 5 Amp and 15 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F Switch Piano type single pole 16/20 Amps One way, fixed in replacement, complete all as specified and directed by Engineer- in - Charge
S&F Switch socket combination piano type 5 pin 5 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge
S&F Switch socket combination piano type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body fixed in replacement, complete all as specified and directed by Engineer - in - Charge.
S&F Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F Electric bell(Ding dong) AC 230/250 volts grade single pole ISI marked fixed in replacement, complete all as specified and as directed by engineer in charge.
Fixing only serviceable MCB DB of any type and capacity obtained from Item No 03 complete all as specified and directed by engineer incharge.
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 8 Way all as specified and directed by engineer in charge.
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 12 Way all as specified and directed by engineer in charge.
S&F in replacement Distribution board 4 way TP&N Double Door IP43-IK09 with metal door are fitted with Bus Bars, Neutral Links suitable for 415V, 50Hz, Blanking Plates, Suitable for TP/FP MCB all as specified and as directed by engineer incharge.
S&F in replacement Distribution board 6 way TP&N Double Door IP43-IK09 with metal door are fitted with Bus Bars, Neutral Links suitable for 415V, 50Hz, Blanking Plates, Suitable for TP/FP MCB all as specified and as directed by engineer incharge.
S&F MCB TPN 63 Amps four pole 415V incl all termnials, fitting etc all as specified and as directed by engineer incharge.
S&F connection and testing 'C' series SPN MCB 40 to 63 Amp 240V, 50Hz, 10kA for lighting and other domesitc loads incl necessary copper lugs etc all as specified and as directed by engineer incharge.
Supply fixing, connection and testing 'C' series MCB SP6-32 Amps all as specified and as directed by engineer incharge.
Supply fixing connection and testing 'C' series MCB SP 40 Amps all as specified and as directed by engineer incharge.
Fixing only serviceable MCB SPN/SP any capacity obtained from item no 03 as above all as specified and as directed by engineer in charge.
S&F Modular fan step regulator 120W 02 module including taking down unserviceble one all as specified and as directed by engineer in charge.
S&FModular switch 01 way 06A, 01 module including taking down unserviceble one all as specified and as directed by engineer in charge.
S&F Modular switch 01 way 16A, 01 module including taking down unserviceble one all as specified and as directed by engineer in charge.
S&F Modular bell push flush type 6A, 01 module including taking down unserviceble one all as specified and as directed by engineer in charge.
S&F Modular socket, 6A-2/3 pin, 02 module including taking down unserviceble one all as specified and as directed by engineer in charge.
S&F Modular socket, 6A/16A-2/3 pin, 02 module including taking down unserviceble one all as specified and as directed by engineer in charge.
S&F PVC rectangular block for mounting switches, sockets, fan regulator etc. of 4 MODULE all as specified and as directed by engineer in charge,
S&F PVC rectangular block for mounting switches, sockets, fan regulator etc. of 6 MODULE all as specified and as directed by engineer in charge,
S&F 3 mm thick plastic laminated ebonite sheet cover of size 200x150mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc all as specified and as directed by engineer in charge.
S&F 3 mm thick plastic laminated ebonite sheet cover of size 250x200mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc all as specified and as directed by engineer in charge.
S&F for Isolator 4 Pole 100 Amp, 415 Volts- all as specified and as directed by engineer in charge.
S&F for Isolator 4 Pole 125 Amp, 415 Volts- all as specified and as directed by engineer in charge.
M&L for disconnecting all Electrical connection from MCB DB TPN/Wall Mounted Panel Box for reconnecting the same with providing proper Copper Bottle Lugs of suitable size and removing the burnt out internal wiring of DB/Panel complete with providing PVC Flexible conduit for Hanging wire complete all as specified and directed by engineer in charge. Note : Replacement Burnt out MCBs of any type/size may be measured and paidseparately under relavent Items
Taking down/removing existing damaged cable connection from MCB DB/Wall Mounted Panel Board by making cutting chases on wall/ floor to extend the shorten UG cable of any type/size from Loop and making fresh to reconnect the same with suitable aluminium lugs complete including distribute the load equally on each phase all as specified and directed by Engineer in charge. Note : Cutting of Wall /Floor shall be measured and paid separately.
M&L for Cutting of hard standing n.exc 45 Cm defth, and n.exc 30 Cm width for taking out/laying UG Cable including making good disturbed surface as per existing all as specified and as directed by engineer in charge.
S&F in repair rigid non- metalic PVC casing and caping of 25/12 mm inclusive of all elbow, tees, etc comlete all as directed by Engr- in- Charge.
S&F in repair LED PLL Lamps (Retro fit) 18 Watt all as specified and as directed by engineer in charge.
S&F angle lamp holder ,pvc / polycarbonate type with back plate suitable for batten fittings all as specified and directed by Engr-in- charge.
M & L for replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps 240 volt capacity complete all as directed.
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply single door SPN DB system 2 Way all as specified and directed by engineer in charge.
RANBIR ENTERPRISES
HIMALAYA ENTERPRISES
MAHAJAN TRADING CO
m/s shanti trading company
DEV RAJ MAGOTRA
VARDHMAN INTERNATIONAL
pargal builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .