Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹74.3 L
EMD Value
₹1.2 L
Closing Date
3 Feb 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Jal Shakti Divn Haroli
Executive Engineer Jal Shakti Divn Haroli
(SH Construction of Pump House at Tahliwal Campus)
2026_HPIPH_126694_1
No. JSV/ Haroli/ TA/ tender/25- 9012-35 dt 24-01-26
Open Tender
Civil Works
Item Rate
90 days
Tahliwal Campus
as per NIT
8 documents required · 8 mandatory
₹2,000
Yes
Executive Engineer Jal Shakti Divn Haroli
₹1.2 L
31 Jan 2026
24 Jan 2026
4 Feb 2026
24 Jan 2026
3 Feb 2026
24 Jan 2026
24 Jan 2026 - 3 Feb 2026
Excavation in earth work in all heights and depth in all kinds of soils, including saturated soil comprising of pick work, jumper work, and blasting work both in soft and hard rock with chiselling and wedging out of rock (where blasting is prohibited) and their intermediate classification of soils including, dewatering wherever required, setting out to required lines, levels as shown on the drawing and directed by the Engineer -in-Charge at site. according to the HP.PWD. specification
P/L cement concrete 1:5:10(1 cement :5 sand: 10 graded stone agg. 40mm nominal size) & curing complete excluding cost of form work in foundation and plinth. within all leads and lifts as per the direction of engineer-in-charge.
Providing and laying cement concrete 1: 3 : 6 ( 1 cement :3 sand : 6 graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts and as per the direction of the Engineer-in-Chaarge (for foundation of Pump)
Providing and laying cement concrete (Mix M-30)1: 1 : 2 ( 1 cement :1 sand : 2 graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts and as per the direction of the Engineer-in-Chaarge (for foundation of Pump)
Providing and laying cement concrete (Mix M-25) 1: 1: 5 :3 ( 1 cement 1:5 sand : 3 graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in:-
in Foundation, footing , bases of column and the like & mass Concrete Complete in all respect.
Columns, pillars , Posts and struts upto floor two level
Lintels, beams griders bressumers and cantilever upto floor two level
Suspended floors,roofs landing and the like landing and shelves and their support balconies, beams, girders, bressumers and contilever upto floor two level With in all leads and lifts and as per the direction of the Engineer-in-Charge.
1st Class Bricks work using common burnt clay building bricks in foundation and plinth in Cement Mortar 1:6 (1 Cement : 6 Sand) all leads and lifts and as per the direction of the Engineer-in-Charge.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete including carriage of material with in all leads and liftsas per the direction of the Engineer-in-Charge.
Brick work using common burnt clay building bricks in super structure above plinth level upto floor level in cement mortor 1:6 ( 1 cement:6 sand ) of 2nd class Brick work Complete in all Respect with in all leads and lifts as per the direction of the Engineer-in-Charge.
Brick work using common burnt clay building bricks in super structure above floor two level in cement mortor 1:6 ( 1 cement:6 sand ) of 2nd class Brick work Complete in all Respect with in all leads and lifts as per the direction of the Engineer-in-Charge.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring, shuttering , strutting and propping etc. height of propping and centering ¢ering below supporting floor to celling not exceeding 4 mtr. and removal of same for in situ Rcc and PCC work in:- below supporting floor two level.
(i) Foundation,footing,bases of columns etc.and mass concrete.within all leads and lifts and as per the direction of Engineer in charge.
Column,pillars,posts & struts square, rectangular or polygonal in plan . and the like complete in respect .within all leads and lifts and as per the direction of Engineer in charge.
Sides & soffits of beams,beam haunchings, catilevers, bressumers & lintels not exceeding 1.00 mtr.depth in all ht.from floor complete in respect .within all leads and lifts and as per the direction of Engineer in charge.
Flat surface such as soffits of suspended floors,roofs,landing and the like floor etc. up to 20mm in thick including complete in respect .within all leads and lifts and as per the direction of Engineer in charge.
Providing mild steel/tor steel reinforcement for reinforced cement concrete work including bending, binding and placing in position complete in all floor levels (a). Tor steel. including carriage of materials within all leads and lifts and as per the direction of Engineer-in-Charge.
Providing and fixing anodised aluminium work for door, window, ventilators and partitions with extruded built up standard tubular and other sections of approved make conforming to IS 733 and IS 1285 anodised transparent or dyed to required shade according to IS 1868. (Minimum anodic coating of grade AC 15) fixed with rawlplugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rustfree, straight, mitred and jointed mechanically where ever required including cleast angle, aluminium, snap beading for glazinge/panelling C.P. brass/stainless steel screws. All complete as per architectural drawings and the directions of Engineer-In-Charge. including carriage of material within all leads and lifts.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partition etc with PVC/neoprens gasket etc. complete as per the architectural drawings and the directions of Engineer-In_charge (cost of aluminium snap beading shall be paid in basic item.) glazing with glass panes of 4mm thickness (weight not less than 10.00 kg/sqm. including carriage of material within all leads and lifts.
Providing 40x3mm flat iron hold fast 40 cms long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15 cms 1:3:6 ( 1 cement :3 sand : 6 graded stone aggregate 20 mm nominal size ) complete in all respect as per the direction of the Engineer -in- Charge.
Providing and fixing M.S. round of square bars with MS flats at required specing in frames of window and clerestory window complete in all respect. within all leads and lifts.
Providing and fixing Ms Handle with necessary screws complete in all respect(125mm)
Providing and fixing M.S. tower bolts (barrel type) anodized transport or dyed to required shade and colour with necessary screws complete in all respect(200x10)
Providing and fixing sliding door bolts black enamelled with nuts bolts and screws complete in all respect(250x16)
15mm (fifteen milimetres) thick cement plasters in single coat on rough side of brick/concrete/stone walls for interior/exterior plastering upto all floor level including arises, internal rounded angles, chamfers and or rounded angles not exceeding 80mm (Eighty milimetres) in girth and finished even and smooth with cement mortar 1:6 (one cement: six sand) including carriage of materials within all leads and lifts and as per the direction of Engineer-in-Charge.
Providing plinth protection 50mm thick in cement concrete 1:3:6 (1 Cement : 3 Sand : 6 Graded stone aggregated 20mm nominal size) with in all leads and lifts complete in all respectas per the direction of Engineer-in-Charge.
Providing under Layer plinth protection 75mm thick in ( unconsolidated) bed dry brick stone aggregated 40mm nominal size with rammed and consolidated and grouted with fine sand including preparation of ground.complete in respect. including carriage of materials within all leads and lifts as per the direction of Engineer-in-Charge.
Providing and fixing 10mm thick anti skid water proof stain and impect resistent heavy duty vetrified tiles Nitco or equivalant 600x600mmx10mm manufactured of approved shade and colour in flooring, treads of steps and landings laid over 12mm thick cement mortar 1:3 (1 cement : 3 sand) jointed with cement slurry mixed with pigment to match the shade of tiles as required complete including carriage of material within all leads and lifts. as per the direction of Engineer-in-Charge.
Structural steel works riveted, bolted or welded in built up sections, trusses and frame work, including cutting, hoisting , fixing in position and applying priming coat of approved steel primer complete in all respect complete in all respect within all leads and lifts as per direction of the Engineer-in-charge.
Providing & fixing 0.60 mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 micron over 5 micron primer coating to back coat of polyster of 5 micron over 5 micron primer coating i/c fixing with prepainted iron J or L hooks, bolts and nuts 6mm diameter s with prepainted limpet rubber washers complete with all accessories as required as per direction of Engineer in Charge. .
Providing and Fixing insulating board celling of approved quality with necessary nails etc. Complete.
Supplying and fixing rolling shutters of spproved make made of 80mmx1.25mm M.S. laths interlocked toghther through their entire length and jointed together at the end by end locks mounted on specially design pipe shaft, with bractes side guides and arrangements for inside and outside locking with push pull operation complete but excluding the cost of top cover and spring shutters having width 3.5 mtrs and above complete in all respect and as per direction and to the entire satisfaction of the Engineer-in-Charge....
White washing with lime on undecorated wall surface ( two coats) to give an even shade including throughly brooming the surface to remove all dirt ,dust mortor drops and loose scale of lime wash and other foreign matter complete in in all respect as per the direction of the Engineer-in-Charge.
Finishing wall with water proofing cement paint of approved brand and Manufacture wall surfaces (two coats) to give an even shade and final finish after throughly cleaning the surface to remove all dirt, dust and other foreign matter etc including sand papering and knotting etc.with in all leads and lifts.as per the direction of the Engineer-in-Charge.
Constructing brick masonary 'U' shape open surface drain with side wall. 30 x 30 cm in cement mortar 1:6 ( 1 cement : 6 sand) and inside plastering with cement plaster 1:3 ( 1 cement : 3 sand) including earth work and laying 10 cm cement concretein 1:5:10 ( 1 cement : 5 sand :10 graded stone aggregate of 40 mm nominal size) and 7.50 cm.cement concrete 1: 2:4 ( 1cement : 2 sand : 4 graded stone aggregate 20 mm nominal size ) and finished with a floating coat of neat cement complete as per standard design.
Providing and laying heavy duty precast cement concrete Interlocking paver blocks having thickness 60 mm complete up to M-50 grade i/c border or kurb grey or coloured over sub base of sand with 25 mm thick average thickness of cement mortar 1:4 laid over jointed with neat cement slurry mixed with i/c curing rubbing & polishing complete in all leads as per the direction of the Engineer-in- Charge.
Providing, fixing and testing as per site requirements, 10.00 tones capacity single girder, power operated overhead travelling crane to suit a span of 8.50 meters (wall to wall), incorporating a Monis balanced spur gear chain pully block and geared tavaled trolley as a lifting and transversing unit fitted with mild steel calibrated hand chain and high tensile steel load chain to suit 6.00 meters heights from floor to top of gantary rail as per drawing including main gantry girder, one motor for hoisting, one motor for cross traverse, two motor, for long travel operated from floor level for by means of penclent push button stations and any other component required for operation of the crane, complete, including parallel Girders for Rolling gantery crane.
Wiring for light/Fan point/Exhaust fan point/call bell point with 1.5 Sq.mm PVC insulated copper conductor cable in surface/recessed PVC conduct at required including carriage of all material within all leads and lifts. Group "C"
Wiring for light/power plug with 2 x 4 Sq.mm PVC insulated copper conductor or single core cable in surface/recessed steel conduit alongwith 1 No. 2.24 mm dia bare copper wire for loop earthing as required including carriage of materials within all leads and lifts.
Wiring for circuit wiring with 2 x 1.5 Sq.mm PVC insulated copper conductor single core cable in surface/ recessed steel conduit as required including carriage of material within all leads and lifts.
Wiring for sub-main wiring with the following size of copper conductor single core cable in surface/recessed steel conduit as required including carriage of materials upto all leads and lifts. 2x6 Sq.mm
Supplying and fixing metal box of 180 x 100 x 60mm deep (Nominal size) on surface/recess with suitable size phonolic leminated sheet cover fixing 3 pim 15/16 amps socket tumber/piano type switch connections painting etc. including carriage of materials within all leads and lifts.
Supplying and fixing backellite batten/angle holder including connection as required.
Providing, installing, testing and commissioning of ceiling fan and regulator including wiring the rod of standard length (upto 30cm) with 1.5 Sqmm PVC insulated copper conductor single core cabe etc. as required sweep type. type 1400 mm Cat. ''A''
Providing, installation, testing and commissioning of prewired flourscent tube fitting complete with ballast, starter and capactors but excluding flourscent tube rod, suitable to operate on 230 volts single phase A.C.supply directly on surface with copper wiring as required including carriage of materials within all leads and lifts tube fixture 1 x 36 watt Box type Category "A".
Supplying and fixing 40Amps to 63 Amps rating 240 Volts "L" series miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required including carriage of material within all leads and lifts. Category- A 63 Amps.
Supplying and fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recessed completed with tinned, copper busher neutral link, earth bar, detachable gland plate inter -connections, including painting, earthing etc. as required Bus bar 12 way.
Supplying and fixing 5 Amps to 32 Amps rating 240 volts, G series miniature circuit breaker of following poles in the existing MCB, DB complete with connections testing and commissioning etc. as required Category "A"single pole.
Earthing with G.I. Pipe earth pipe, 4.5mtrs length,40mm dia including accessories and providing masonary enclousres with cover plate having locking arrangement and watering pipe etc.(but without charcal coke and salt)Complete as required including carriage of material within all leads and lifts.
Extra using salt and charcoal for G.I earth Pipe electrode is required including carriage of materials upto all leads and lifts.
Supplying and laying 6sqmm G.I wire at 0.50 mtr below ground level for conductor eatrh electrode,including soldering etc.as required including carriage of materials upto all leads and lifts.
Providing, fixing & testing Street Light Fixture with CFL of 36 watt, copper ballast, G.I. Pipe bracket, complete in all respects.
Supplying and fixing of integral CFL post top lateran of following capacity , cast aluminum spigot, spun aluminum canopy, opal acrylic, deffusers complete with all accessories but excluding CFL lamp i/c making connections testing and commissioning etc as required. Gate Post Top Lanteern CFL 2X18 Watt
Providing and laying of 1 No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground lavel i/cexcavation sand cushioning, and protective covering and Refilling the trenches etc.of required Size
Armoured cable 4 sq. mm (Twin core)
Armoured cable 6 sq. mm (Twin core)
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.Including carriage of materials within all leads and lifts. RCCB 63 Amp. Cat-A
Providing and installation of Exhaust fan of following size in the existing opening ,i/c making holeto suit size of the above afn, making wood the damages , connections testing and commissioning etc. as required
Exhaust fan Heavy Duty 600 mm sweep
Exhaust fan Heavy Duty 450 mm sweep ( domestic)
Providing, Installation, testing and commissioning of Street Light of 100 watt, with 80 mm dia 4 meter long Pipe + 2 meter bend piece,Make Havells, complete in all respect.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.30 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.65 MB
Tendernotice_2.pdf
PDF • 0.21 MB
Tendernotice_3.pdf
PDF • 0.14 MB
Tendernotice_4.pdf
PDF • 0.09 MB
BOQ_186935.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .