Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.2 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC DUE TO L1 | |
| 2 | L2₹48.2 L+₹62,871.50 (1.32%)Rejected-Finance | L2 | Rejected-Finance HIGHER RATE | |
| 3 | L3₹51.1 L+₹3.5 L (7.39%)Rejected-Finance | L3 | Rejected-Finance HIGHER RATE | |
| 4 | L4₹52.3 L+₹4.8 L (10.0%)Rejected-Finance | L4 | Rejected-Finance HIGHER RATE | |
| 5 | L5₹53.4 L+₹5.9 L (12.4%)Rejected-Finance | L5 | Rejected-Finance HIGHER RATE |
| Sl No | Description | Qty | Unit | H.B. Traders L3 | S.R. Constructions L5 | SANJEEV ENTERPRISES L1 | PARAS ENTERPRISES L4 | J B ELECTRICALS L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of 1000mm long rigid architectural RGBW (W=4000K) LED Linear light having housing of Extruded aluminium alloy 6063 grade & die-cast aluminium end caps. The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire width shall be 38mm & height of 47mm without brackets. The luminaire’s integrated brackets shall be made of extruded aluminium & the same shall be so designed that the luminaire can be tilted ±95°. The luminaire shall have silicon glue between optical cover & LED chamber to ensure proper IP66 protection. The nominal weight of the luminaire shall be 1.55KG (±10%). The luminaire shall be equipped with high-power Cree, osram, lumiled or equivalent. The fixture shall have 25°X40° beam angle & the lens shall be made of anti-aging & anti UV-PMMA material. The optical cover shall be made of IK06 rated clear tempered glass. The LEDs shall have minimum CRI ≥80 & shall have SDCM≤4. The fixture shall come with power & DMX cable of minimum 100mm length. The fixtures shall be installed with have IP67 connectors. The luminaire shall have system wattage not exceeding 24W and system lumen output of not less than 800 lumens. Fixture shall operating temperature range of -40°C to 50°C. The fixture shall have a non-integral driver with input voltage of 24V DC. The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. The luminaire shall be capable of digital dimming of 65536 steps complete all as specified and directed.
Make: Signify (Philips) or equivalent in iGuzzini/ Linealite/ Martin/ We-ef | 58 | Each | 10,500 ₹6,09,000 Lowest | 11,100 ₹6,43,800 | 15,820 ₹9,17,560 | 11,000 ₹6,38,000 | 10,500 ₹6,09,000 Lowest |
| 2.00 | Supply, installation, testing and commissioning of Supply of architectural RGBW (W=4000K) LED flood light with integral driver & housing made ofextruded Al with Die-cast aluminium end caps. The luminaire shall be have min dimension 155 X 140X149 (±10%) with bracket. The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°. The bracket shall have locking mechanism to fix & secure the desired tilt angle. The luminaire shall have silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. The luminaire must have a breather gland. The luminaire shall be equipped with high-power LED's from Cree, osram, lumiled makes only. The fixture shall have 10° beam angle (±10%) & the lens shall be made of anti-aging & anti UV-PMMA material. The optical cover shall be made of IK06 rated clear tempered glass. The LEDs shall have minimum CRI ≥80 for white light & shall have SDCM≤4. The fixture shall come with power & DMX cable of minimum 100mm length. The fixtures shall be installed with have IP67 connectors. The luminaire shall have system wattage not exceeding 24W and system lumen output of not less than 1200 lumens. Fixture shall operating temperature range of -40°C to 50°C. The fixture shall have an integral driver with input voltage for 220-240 VAC, 50/60Hz. The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall give feedback on luminaire address & status (ON & Off). The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. The luminaire shall be capable of digital dimming of 65536 steps complete all as specified and directed.
Make: Signify (Philips) or equivalent in iGuzzini/ Linealite/ Martin/ We-ef | 7 | Each | 19,000 ₹1,33,000 Lowest | 21,000 ₹1,47,000 | 26,778 ₹1,87,446 | 20,000 ₹1,40,000 | 21,500 ₹1,50,500 |
| 3.00 | Supply, installation, testing and commissioning of exterior IP68 LED RGB/RGBW Flexible light strip of 5 mtr standard length with 10-15 Watt per meter which can be compatible with the DMX / Ethernet controller. Minimum System lumens of minimum 450 lumens/meter and System Lumen Efficacy > 30lm/w. Luminaire light beam spread - 110°, The Strip should have IP 68 protection and is offered IP 67 rated connector to join the LED Strips incontinuity. The luminaire must be offered with Aluminum channel for mounting the strip lights. The product should be complete with all accessories and Driver. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The bidder shall upload the luminaire BIS certificate along with technical bid. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables complete all as specified and directed.
Make: Signify (Philips) or equivalent in iGuzzini/ Linealite/ Martin/ We-ef | 15 | Each | 14,000 ₹2,10,000 Lowest | 16,500 ₹2,47,500 | 19,884 ₹2,98,260 | 15,000 ₹2,25,000 | 15,500 ₹2,32,500 |
| 4.00 | S&F IP65 150W 24V driver complete all as specified and directed. | 10 | Each | 12,000 ₹1,20,000 | 9,900 ₹99,000 | 10,000 ₹1,00,000 | 10,000 ₹1,00,000 | 7,500 ₹75,000 Lowest |
| 5.00 | S&F DMX decoder complete all as specified and directed. | 10 | Each | 12,000 ₹1,20,000 | 9,000 ₹90,000 | 3,540 ₹35,400 Lowest | 10,000 ₹1,00,000 | 7,500 ₹75,000 |
| 6.00 | S&F AL profile (1m) complete all as specified and directed. | 60 | Each | 1,300 ₹78,000 | 900 ₹54,000 | 470 ₹28,200 Lowest | 1,000 ₹60,000 | 1,100 ₹66,000 |
| 7.00 | S&F ZGC 301 IP connector (10Bags) complete all as specified and directed. | 2 | Each | 1,300 ₹2,600 | 900 ₹1,800 Lowest | 1,233 ₹2,466 | 1,000 ₹2,000 | 1,000 ₹2,000 |
| 8.00 | Supply, installation, testing and commissioning of Compact master Content Program Controller (DMX controller) with capability to control minimum 8 DMX512 universes, playback scenes and animations stored in its SD card, and it can be used for offline scenes scheduling, setting brightness, white balance and playback speed adjustments. It should be able to amplify the DMX signal in cascaded connection & support automatic playback scheduling. It should support power-on startup and scheduled timing start along with capability of unattended operation and remote scene triggering if needed. The Content Program Controller shall have integrated LCD display & support IR remote control. The dimensions of the Content Program Controller shall be approximately 278X193X66 mm (±10%). It should be housed in aluminium casing. The Input voltage shall be 12VDC & shall have 2 RJ45 ports on Input side. The IEC classification shall be Class III. It should operate on DM512 protocol. The output shall have 8 X 3P lockable terminals. The power consumption shall be 8W (±10%). The Content Program Controller shall have one SD card slot for maximum 32GB card & the SD card being used shall be FAT32 format. The Content Program Controller shall come with 220-240V to 12V DC power supply. The IP rating of content program controller shall be IP20 & shall comply to CE, CB & CQC certifications. The DMX controller/content program controller shall be from the same make/brand/manufacturer as that of façade lighting luminaires. The working temperature range shall be -30°C to 50°C. The successful bidder shall submit the technical data sheet for approval before supply of material complete all as specified and directed.
Make: Signify (Philips) or equivalent in iGuzzini/ Linealite/ Martin/ We-ef | 1 | Each | 1,85,000 ₹1,85,000 | 1,45,600 ₹1,45,600 Lowest | 3,41,079 ₹3,41,079 | 1,50,000 ₹1,50,000 | 1,48,000 ₹1,48,000 |
| 9.00 | Supply, installation, testing and commissioning of RDM-6Wall Splitter & Booster,should be able to provide 6-output DMX/RDM splitter with DMX/RDM pass-through supporting bi-directional communications for discovery, addressing and DMX control of Ethernet/DMX products.This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6x32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Surface or DIN-rail mountable,Isolated DMX/RDM Input/Outputs,Automatic switching between DMX and RDM mode for auto-discovery, Environment-IP20, Interior applications,Finish/Color-Polycarbonate complete all as specified and directed.
Make: Signify (Philips) or equivalent in iGuzzini/ Linealite/ Martin/ We-ef | 2 | Each | 25,000 ₹50,000 Lowest | 31,600 ₹63,200 | 37,000 ₹74,000 | 30,000 ₹60,000 | 28,500 ₹57,000 |
| 10.00 | Supply and fixing of 4P DMX leader cable for connecting luminaire with power supply having length min 2m length (min 10 nos in 1 packet) complete all as specified and directed. | 1 | Each | 15,000 ₹15,000 Lowest | 21,000 ₹21,000 | 21,000 ₹21,000 | 20,000 ₹20,000 | 18,500 ₹18,500 |
Tender Value
Refer Docs
EMD Value
₹97,243
Closing Date
18 Jul 2025, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI, SP MARG NAR ABHM GATE NO 5
PROVN OF FACADE LIGHT AT VARUNIKA AUDITORIUM AND ADDN/ ALTN AND SPL REPAIR FOR REPLACEMENT OF OLD UNSV BOLLARD LIGHTS AT CHANAKYA BAGH, CHANAKYAPURI UNDER GE NEW DELHI
2025_MES_715286_1
NIT No GE/ND-25/2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
GE NEW DELHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE NEW DELHI
₹97,243
Yes
22 Sept 2025
18 Jun 2025
21 Jul 2025
18 Jun 2025
18 Jul 2025
3 Jul 2025
Amount
Supply, installation, testing and commissioning of 1000mm long rigid architectural RGBW (W=4000K) LED Linear light having housing of Extruded aluminium alloy 6063 grade & die-cast aluminium end caps. The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire width shall be 38mm & height of 47mm without brackets. The luminaire’s integrated brackets shall be made of extruded aluminium & the same shall be so designed that the luminaire can be tilted ±95°. The luminaire shall have silicon glue between optical cover & LED chamber to ensure proper IP66 protection. The nominal weight of the luminaire shall be 1.55KG (±10%). The luminaire shall be equipped with high-power Cree, osram, lumiled or equivalent. The fixture shall have 25°X40° beam angle & the lens shall be made of anti-aging & anti UV-PMMA material. The optical cover shall be made of IK06 rated clear tempered glass. The LEDs shall have minimum CRI ≥80 & shall have SDCM≤4. The fixture shall come with power & DMX cable of minimum 100mm length. The fixtures shall be installed with have IP67 connectors. The luminaire shall have system wattage not exceeding 24W and system lumen output of not less than 800 lumens. Fixture shall operating temperature range of -40°C to 50°C. The fixture shall have a non-integral driver with input voltage of 24V DC. The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. The luminaire shall be capable of digital dimming of 65536 steps complete all as specified and directed. Make: Signify (Philips) or equivalent in iGuzzini/ Linealite/ Martin/ We-ef
Supply, installation, testing and commissioning of Supply of architectural RGBW (W=4000K) LED flood light with integral driver & housing made ofextruded Al with Die-cast aluminium end caps. The luminaire shall be have min dimension 155 X 140X149 (±10%) with bracket. The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°. The bracket shall have locking mechanism to fix & secure the desired tilt angle. The luminaire shall have silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. The luminaire must have a breather gland. The luminaire shall be equipped with high-power LED's from Cree, osram, lumiled makes only. The fixture shall have 10° beam angle (±10%) & the lens shall be made of anti-aging & anti UV-PMMA material. The optical cover shall be made of IK06 rated clear tempered glass. The LEDs shall have minimum CRI ≥80 for white light & shall have SDCM≤4. The fixture shall come with power & DMX cable of minimum 100mm length. The fixtures shall be installed with have IP67 connectors. The luminaire shall have system wattage not exceeding 24W and system lumen output of not less than 1200 lumens. Fixture shall operating temperature range of -40°C to 50°C. The fixture shall have an integral driver with input voltage for 220-240 VAC, 50/60Hz. The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall give feedback on luminaire address & status (ON & Off). The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. The luminaire shall be capable of digital dimming of 65536 steps complete all as specified and directed. Make: Signify (Philips) or equivalent in iGuzzini/ Linealite/ Martin/ We-ef
Supply, installation, testing and commissioning of exterior IP68 LED RGB/RGBW Flexible light strip of 5 mtr standard length with 10-15 Watt per meter which can be compatible with the DMX / Ethernet controller. Minimum System lumens of minimum 450 lumens/meter and System Lumen Efficacy > 30lm/w. Luminaire light beam spread - 110°, The Strip should have IP 68 protection and is offered IP 67 rated connector to join the LED Strips incontinuity. The luminaire must be offered with Aluminum channel for mounting the strip lights. The product should be complete with all accessories and Driver. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The bidder shall upload the luminaire BIS certificate along with technical bid. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables complete all as specified and directed. Make: Signify (Philips) or equivalent in iGuzzini/ Linealite/ Martin/ We-ef
S&F IP65 150W 24V driver complete all as specified and directed.
S&F DMX decoder complete all as specified and directed.
S&F AL profile (1m) complete all as specified and directed.
S&F ZGC 301 IP connector (10Bags) complete all as specified and directed.
Supply, installation, testing and commissioning of Compact master Content Program Controller (DMX controller) with capability to control minimum 8 DMX512 universes, playback scenes and animations stored in its SD card, and it can be used for offline scenes scheduling, setting brightness, white balance and playback speed adjustments. It should be able to amplify the DMX signal in cascaded connection & support automatic playback scheduling. It should support power-on startup and scheduled timing start along with capability of unattended operation and remote scene triggering if needed. The Content Program Controller shall have integrated LCD display & support IR remote control. The dimensions of the Content Program Controller shall be approximately 278X193X66 mm (±10%). It should be housed in aluminium casing. The Input voltage shall be 12VDC & shall have 2 RJ45 ports on Input side. The IEC classification shall be Class III. It should operate on DM512 protocol. The output shall have 8 X 3P lockable terminals. The power consumption shall be 8W (±10%). The Content Program Controller shall have one SD card slot for maximum 32GB card & the SD card being used shall be FAT32 format. The Content Program Controller shall come with 220-240V to 12V DC power supply. The IP rating of content program controller shall be IP20 & shall comply to CE, CB & CQC certifications. The DMX controller/content program controller shall be from the same make/brand/manufacturer as that of façade lighting luminaires. The working temperature range shall be -30°C to 50°C. The successful bidder shall submit the technical data sheet for approval before supply of material complete all as specified and directed. Make: Signify (Philips) or equivalent in iGuzzini/ Linealite/ Martin/ We-ef
Supply, installation, testing and commissioning of RDM-6Wall Splitter & Booster,should be able to provide 6-output DMX/RDM splitter with DMX/RDM pass-through supporting bi-directional communications for discovery, addressing and DMX control of Ethernet/DMX products.This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6x32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Surface or DIN-rail mountable,Isolated DMX/RDM Input/Outputs,Automatic switching between DMX and RDM mode for auto-discovery, Environment-IP20, Interior applications,Finish/Color-Polycarbonate complete all as specified and directed. Make: Signify (Philips) or equivalent in iGuzzini/ Linealite/ Martin/ We-ef
Supply and fixing of 4P DMX leader cable for connecting luminaire with power supply having length min 2m length (min 10 nos in 1 packet) complete all as specified and directed.
Supply and fixing of endcap male connector (pack of 20 pcs) complete all as specified and directed.
Supply and fixing of endcap female connector (pack of 20 pcs) complete all as specified and directed.
Supply and fixing of 5P DC/DMX leader cable for connecting luminaire with power supply having length min 2m length (min 10 nos in 1 packet) complete all as specified and directed. Make: Signify (Philips)/ iGuzzini/ Linealite/ Martin/ We -ef.
Supply and fixing of 5P DC/DMX jumper cable for interconnecting the façade luminaires having length min 2m length (min 10 nos in 1 packet) complete all as specified and directed.
Programming for lighting management system includes addressing for all smart lighting fixture along with mapping on connected system. All fixture to be programmed as per the site requirement. Min 5 Scenes to be created & configure on smart keypad for ease of operation of smart light system complete all as specified and directed. Note: (a) The work has to be executed through OEM/OEM authorised agency only. (b) The contractor must sign bid specific MoU with the OEM for execution of workthrough OEM/OEM authorised agency. (c) The contractor must submit the copy of the MoU signed with OEM at the time of submission of Technical bid, falling which his technical bid shall be summarily rejected. Note For item No 01 to 15: (a) The quoted rates also include the cost of 2 run conduit of 25mm for power cable and Data cable. (b) The quoted rates also include the cost of required 4.0,2.5 and 1.5 sqmm wire for connections (03 run cable) for Phase,Neutral and earth wire as per OEM recommendation. (c) The quoted rates also include the cost ofarmoured Cat6/control cable and splitter boxes as per OEM recommendation. (d) The quoted rates also include the cost of necessary junction boxes with IP 66 protection, connectors drivers, shaddle, flexible conduit, assembly bracket, metal gauge, cable tray, switch, socket etc. (e) Any item not covered under this schedule shall be deemed to be included in this section for installation and testing of facade lighting and the contractor may quote the rate accordingly.
Supplying, installation, testing and commissioning in replacement of LT panel 3.15 mm thick cubical outdoor type weather proof, totally enclosed with IP 65 protection made out of CRCA sheet angle iron of size 50 mm x 50 mm x 6 mm suitable for 3 phase, 4 wire ,440 volts, 50 Hz including cable glands, phase indicators, internal wiring,CT of suitable Ratio, voltmeter, ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc and locking arrangement with two locks godown type welded inside of the shutter with duplicate keys, spray painting with two coats of light gray paint over a coat of red oxide primer and mounted on two No bricks pillars including excavation and earth work complete PCC (1:2:4) brick work (1:4) and plastering complete all as specified and directed. Incoming:- (a) MCB TPN 40 Amps Pole,- 01 No (b) Power contactor- 32 Amps- 03 Nos (c) Surge protection device- 01 No (d) RYB Indicating lamp (e) Digital Voltmeter and ammeter of suitable rating (f) Start/stop Push Button-1 No (g) Over voltage/under voltage relay-01 No Outgoing:- (a) MCB SP 06-32 Amps - 10 Nos
Supply, installation, testing and commissioning of single phase voltager stabilizer of capacity 05 KVA,Minimum input voltage 90-130V,minimum output voltage130V, maximum output voltage 290-300 Volts including digital display,digital indicators,over volt protection and overload protection complete all as specified and directed by Engr- In- Charge.
S&F factory made concealed sheet steel distribution boards, double door, SPN, 08 way, 230 volts AC, IP 43 with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing complete all as specified and directed.
S&F MCB SPN 20-32 Amps, 240 Volts, 10 KA, `B' curve, complete all as specified and directed by Engr-in-Charge.
Supply and fixing RCCB double pole 20-32 Amps, sensitivity 30 mA, for earth leakage and shock protection complete all as specified and directed by Engr-In-Charge. Make:- Havells/Legrand/Schneider.
Supply and fixing of MCB SP, 240V 10KA, B curve of 10 Amps complete all as specified and directed by Engr-in-Charge.
M&L for point wiring with PVC insulated unsheathed multi stranded FRLS type copper conductor cable of size 1.5 Sqmm 1100 V grade including one run of PVC insulated unsheathed multi stranded FRLS type copper conductor cable of size 1.5 sqmm as earth continuity conductor connected to common earth dolly in and including PVC concealed conduit 20 mm dia medium grade ISI marked and its accessories including provn of new factory made pressed steel modular switch/ terminal box of suitable size and new modular front & back plates of approved colour/model of suitable size for housing the modular switches, sockets, fan regulators for one light/ fan/ exhaust fan point controlled by one No, one way 5 Amp switch complete all as specified and directed.
All as per item No 22.00 above but One three pin 5 Amp socket outlet point controlled by one no, one way switch on independent board complete all as specified and directed.
All as per item No 22.00 above but with 2.5 sqmm (for phase, neutral) and 2.5 sqmm (for continuous earth wire) cable for one 15/16 amp socket out let point on independent board complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as specified and directed by Engr-in-Charge.
S&F in replacement of 10-12 Watt LED bollard light warm white made of premium quality material in IP -65 Protection, fully weather proof, LED integrated, anti rust anti dust, perfectly suitable for ambiance creation and beautiful light pattern light, input voltage 220-240 Volt, 50 HZ, low power warm white LED including suitable nut bolt, foundation of size 300mmX300mmX450mm cement concrete (1:2:4) type B1 (20mm stone aggregate) to fix the light including excavation and earth work complete all as specified and directed by Engr-In-Charge. Make: Philips Cat part No 582091/ Lustre Cat Part No Li-80016-10(LIBLF-10)/ Homdec Cat Pat No HL-2345A
S&F of 10-12 Watt LED bollard light warm white made of premium quality material in IP -65 Protection ,fully weather proof,LED integrated,anti rust anti dust,perfectly suitable for ambiance creation and beautiful light pattern light,input voltage 220-240 Volt, 50 HZ ,low power warm white LED including suitable nut bolt,foundation of size 300mmX300mmX450mm cement concrete (1:2:4) type B1 (20mm stone aggregate) to fix the light including excavation and earth work complete all as specified and directed by Engr-In-Charge. Make: Philips Cat part No 582091/ Lustre Cat Part No Li-80016-10(LIBLF-10)/ Homdec Cat Pat No HL-2345A
S&F high-quality LED Flood Light with a minimum system lumen of 5500 lm and system wattage not exceeding 50W. The luminaire should have minimum system efficacy of 110 lumen/watt for the offered wattage. The LED used shall have CCT of 3000K, SDCM ≤ 5 and CRI≥70. The housing should be made of Single Piece pressure die-cast aluminum & the luminaire shall have toughened glass front cover. The luminaire LED shall have declared Lifetime of 50K hours@L70. The Ingress protection should be minimum IP65 & impact resistance shall be IK07. The Luminaire should have 4KA internal surge protection. The driver shall have operating voltage of 140V to 270V, PF≥0.95 @full load, THD≤10% @ full load & complay to Electronic driver efficieny of ≥85% & Driver tc shall be ≤ 85⁰C. The luminaire shall pass Insulation Resistance test @ ≥ 2MΩ. The luminaire Working Temp. range should be from 0⁰ to 50⁰C. The luminaire shall pass electric strength test & Withstood satisfactorily 1480Vrms for 1min between live parts & accessible parts specified.. The luminaire shall be able to give Constant Light output (CLO) between voltage range of 140V to 277V including necessary electric connection complete all as specified and directed. Make:- Philips/ Regent/ Trilux/ Osram.
S&F high-quality LED recessed uplighter with inbuilt DMX decoder having system wattage not exceeding 36W (±2W). The product shall have RGBW (≤4 SDCM) light output & must be DMX 512 controlled, The housing should be made of Piece pressure die-cast aluminum & Frame should be of Stainless Steel Ring with High quality temper glass cover min 12mm with PC lens secondry optics. The luminaire shall have declared Lifetime of 50K hours@L70. The Ingress protection should be minimum IP67 & impact resistance shall be IK10. The Luminaire should have a minimum AC: L to N: 1kV, L to ground &N to ground: 2kV surge protection. The driver shall have operating voltage of 110V to 240V, PF≥0.90 @full load, Working Temperature Range -40℃ to +50℃ & product beam angle shall be 20°. The luminaire shall pass Insulation Resistance test @ ≥ 2MΩ. The luminaire Working Temp. range should be from 0⁰ to 50⁰C. Power Connection single flying cable 30cm+/-5cm and single IP68 connector, PG13.5 gland, H05RN-F 3*1mm2. fixture must be CB/EMC/CE/CCC certified including necessary connection with electric supply complete all as specified and directed. Make : Philips/ Regent/ Osram.
Supply, laying and testing cable XLPE insulated, screened,PVC bedded, galvanized steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm X 2 core including taking down old unsv cable complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for laying of LT under ground cable including taking down of old U/s bricks complete all as specified and directed.
M&L for Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and directed.
Laying only serviceable sub class ‘B’ bricks as retrieved from Srl item No 31.00 above complete all as specified and directed by Engr-in-Charge.
Supply local sand cushioning, with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and directed.
Returning filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and directed.
Removing excavated materials to a distance not exec. 50 mtr and deposing where directed at a level not exec 1.5 mtr above the starting point complete all as specified and directed. Note: (a) Srl Item No 01.00 to 03.00, 08.00, 09.00, 14.00, 15.00 & 26.00 to 30.00 of BOQ are major items for the subject tender and material in respect of these items shall be procured within one month after placing of work order and produced before Engg in Charge alongwith original purchase vouchers as per direction of Garrison Engineer and shall obtain a certificate from Engg in charge that material in respect of above mentioned items have been submitted in the office of Engg in charge in their safe custody. (b) Materials in respect of Freakishly low declared items if any at the time of acceptance of contract shall be procured within one month after placing of work order and submit the same in the office of Engg in charge alongwith original purchase vouchers in their safe custody and shall obtain a certificate from Engg in charge.
J B ELECTRICALS (BID ID -3354820)
H.B. Traders (BID ID -3353035)
PARAS ENTERPRISES (BID ID -3352902)
S.R. Constructions (BID ID -3353042)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .