| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.5 Cr+₹3.4 L (2.29%)Rejected-Finance | ₹1.5 Cr+₹3.4 L (2.29%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹1.7 Cr+₹28.5 L (19.5%)Rejected-Finance S NO 41 4K JAIHIND SOCIETY GANESH NAGAR NEAR ANAND PARK VADGAON SHERI PUNE 411 014 | PUNE | PUNE | MAHARASHTRA | 411014 | ₹1.7 Cr+₹28.5 L (19.5%) | L3 | Rejected-Finance Being other than L1 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected being 03 class below eligible class |
| 5 | Rejected-Technical 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | - | Rejected-Technical Rejected being not enlisted in appropriate category |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
9 Apr 2024, 6:00 pmClosed
Col Sharath Ravindran CWE
CWE(AF) Chakeri
PROVN OF FIRE DETECTION AND ALARM SYSTEM IN CERTAIN BLDG AT 24 ED UNDER AGE (I) MANAURI
2023_MES_587002_3
CWE(AF)/CHK/MNR/T-42 OF 2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE (I) AF Manauri
pLEASE REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
AGE(I) AF Manauri
₹2.2 L
4 Jun 2024
2 Mar 2024
17 Apr 2024
2 Mar 2024
9 Apr 2024
27 Mar 2024
Amount
Supply, Installation, testing and commissioning of surface mounting Analague Addressable fire alarm control panel 1 loop with EN 54. The panel shall be compliant with EN 54-2 and EN 54-4, capacity from 99 detector and 99 moduls devices upto 200 detector single loop, The panel must have 2 inbuilt programmable sounder circuits, each circuit rated at 1 amp, 16 Zonal LED indicators, 5 programmable inputs, 3 programmable relays, 3 A power supply, large graphic display, real time clock. The panel must have expandable feature from 1 to 2 loops. The panel shall have up to 512 sub addressable programmable Inputs/Outputs via optional RS 485 COMMS serially connected expansion cards. Powerfull wide cause and effects, sensitivity adjustment and drift compensation, stores 500 last events in event log, indicating panel sounder circuits complete with LCD Display with back light illumination and push button to acknowledge alarm, including 7 Ah 12 V (2 per panel) battery, panel constructed by 1.2 mm thick mild sheet steel, epoxy powder coated finishing, display 8 line of 40 characters graphic LCD, testing and reset suitable for operation 230 volts single phase 50 Hzs AC supply 24 V DC supply with suitable capacity charger including maintenance free batteries and battery charger,mains voltage 110 or 230 V AC 50 or 60 Hz, mains supply fuse 1.6 A 250 V, IP 30, fire contact rating 30 V DC1 Amp, alarm contact rating, 30V DC1 Amp, sounder output rating fused at 1 Amp each, detection loop 400 miliamp output, Dimension of Panel 385x310x90mm, requires network card and modules including Flush mounting accessories, Large enclosure and all fixing accessories complete all as specified and directed by Engr-in-Charge.
Supply, Installation, testing and commissioning of surface mounting Analague Addressable fire alarm control panel 2 loop with EN 54. The panel shall be compliant with EN 54-2 and EN 54-4, capacity from 99 detector and 99 module devices upto 200 detector (per each loop) for two loop,The panel must have 2 inbuilt programmable sounder circuits, each circuit rated at 1 amp, 16 Zonal LED indicators, 5 programmable inputs, 3 programmable relays, 3 A power supply, large graphic display, real time clock. The panel must have expandable feature from 1 to 2 loops. The panel shall have up to 512 sub addressable programmable Inputs/Outputs via optional RS 485 COMMS serially connected expansion cards. Powerfull wide cause and effects, sensitivity adjustment and drift compensation, stores 500 last events in event log, indicating panel sounder circuits complete with LCD Display with back light illumination autodialler and push button to acknowledge alarm, including 7 Ah 12 V (2 per panel) battery, panel constructed by 1.2 mm thick mild sheet steel, epoxy powder coated finishing, display 8 line of 40 characters graphic LCD, testing and reset suitable for operation 230 volts single phase 50 Hzs AC supply 24 V DC supply with suitable capacity charger maintenance free batteries and battery charger,mains voltage 110 or 230 V AC 50 or 60 Hz, mains supply fuse 1.6 A 250 V, IP 30, fire contact rating 30 V DC1 Amp, alarm contact rating, 30V DC1 Amp, sounder output rating fused at 1 Amp each, detection loop 400 miliamp output, Dimension of Panel 385x310x90mm, 2 sounder circuits PTR requires network card and modules including Flush mounting accessories, Large enclosure with all fixing accessories complete all as specified and directed by Engr-in-Charge.
Supply, Installation, testing and commissioning to addressable intelligence having inbuilt microprocessor with twin blinking LED, memory and decision alogrithm twin angle with both forward and backward light scattering mechanism cum thermal multicriteria detector (Analogue Multi-sensor) with heat and smoke combination, high performance chamber, operating voltage 17-41 VDC, operating temprature range -10 degree Centigrade to +50 degree centigrade, pulsing /non pulsing controlled from panel alongwith response indicator flush/ceiling wall mounted type,compatible for 2 wire detector,alarm status is indicated by Red colours LED,dual LEDs for 360 degree visibility including detector base with locking features to prevent unauthorised removal, stainless steel contact, confirms EN 54-5 & EN 54-7 LPCB and Vds approved complete all as directed by Engr-in-charge. Note: The multi detector are to be installed above false ceiling/enclosed space. The rates shall deemed to be inclusive for taking down false ceiling and refixing the same position to match the existing surface with finishing, painting etc.
Supply, installation, testing and commissioning of IR3 based flame detector with relay type module/Zone module, IP65/IP66 protection, mounting stand (stainless steel adjustable mount), detector detects multi spectral sensitivity of fire by using IR sensors, detectors complying with and certified to EN-54-10/IIC Approval/PESO certified/CIMFR tested,confirming to relevant IS, design for long distance detection range of more than 25-40 mtr for viewed angle, response time typically less than 5 second, field of view 90 degree conical field of view or 45 degree either side of the viewing axis centre line, supply voltage 10 -28 VDC typically 24 VDC, LED indication system, operating temprature and storage temprature -20 degree C to 60 degree C, humidity less than 95% including SMPS (switched mode power supply AC to DC ) suitable configuration for RS 485 or 4-20MA complete and all as directed by Engr-in-Charge. Note:- (a) Contractor shall quote the rate including meeting the all power input requirement and accessories as required for functioning the flame detector including point wiring. (b) Submain wiring for looping shall be measured and paid separately under respective items. (b) Contractor shall provide guarantee of flame detector IR3 as per OEM but not less 02 years from the actual date of completion
Supply, installation testing and commissioning of Analogue Addressable Manual call point with integral short circuit isolator, with flush mounting glass box resettable type, unique plug and play installation concept, confirms to EN 54-11 & EN-54-17, LPCB approved, Vds approved resettable glass type compatible with main fire alarm control board microprocessor based and blinking facility complete Analogue addressable protocol having, Bi-coloured status LED, Non-frangible element fitted as standard (confirms to EN 54), complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of addressable wall mounted intelligent loop powered electronic sounder cum strobe, with 30 inbuilt tones(all tones as per EN54-3), low power requirement, 07 volume levels, IP 65 rating, LPCB approved in accordaance to EN-55 part -3 complete as specified as per Engineer in charge.
Supply, installation, testing and commissioning of sensor common mounting base, features integral short circuit isolator, slim profile,EN-54-17 Approved by LPCB and Vds approved operating voltage 15 to 30 Vdc complete all as specified and directed by Engr-in-Charge.
Material and labour for unarmoured sheathed and twin core twisted cable FRLSH multi stranded copper conductor 1.50 Sqmm 2 core 1100 volts control cable as per IS-7098 and including drawing through on wall/ceiling in rigid PVC conduit medium grade pipe, 20 mm dia in suitable size with all necessary fittings, tee, elbow, u-clip, etc complete all as specified and as directed. Note : (i) unarmoured sheathed 1.50 sqmm 2 core with one run of PVC conduit pipe 20 mm dia medium grade shall be measured as one unit.
Supply,laying, Jointing, testing and commissioning in trenches/fixing with clamp on wall connecting, thembling, glanding of XLPE insulated PVC innersheathed, armoured, galvanised steel strip or wire, LT control cable FRLSH multistranded copper conductor, 1100 volts grade, cross-sectional area 2.50 Sqmm 4 core as per IS 7098 (Part I) 1988 complete all as specified and directed by Engr-in-Charge.
Supply and fixing ONLINE UPS 1KVA (1000 VA) 6 Volt pure sinewave with in-Built batteries,40-50 Min backup, inbuilt OVCD (over voltage Cut of Device) with surge protection, efficient micro controller based, advanced PFC technology, static by pass-improves reliability, over temperature indication and protection, generator compatible, boost function for low input over voltage protection Extended input voltage range of 135 to 300 volt UPS to battery backup mode including wall mounted stand for UPS suitable size complete all as directed by Engr-in-Charge.
Supply and fixing fire alarm sirens Electronics horizontal type continous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured, single phase, 220/250V, 6000 RPM, 50 Hz, AC supply, at 1.5 Mtr with sound output variation of +5 db 500 m range, IP-65 Weatherproof, with suitable size of mounting stand and protection cover for siren complete all as directed by Engr-in-Charge
Supply and fixing of control unit for siren with Addressable Control Module for integration with main Fire Alarm panel complete all as directed by Engr-in-Charge.
Supply, Installation, testing and commissioning of Network module. The module shall connect panels and repeator panels through RS 485. The modules shall use RS 485 data at a baud rate. The Network module must be configured master/slave, multiple Master/Slave and peer to peer Networking, Net work card for integration of 2 loop Panels into a networked system complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commisioning of Active Repeater panel to be integrated with Fire alarm control panel, IP30 rating, larger display full colour 800 x 480 LCD with resistive touch screen and automatic back-light dimming and the status of any fire/fault of integarated fire alarm panels, panel should compliant with EN54-2, 1.2 mm mild sheet steel construction, Epoxy powder coated finishing, 3 knockouts top, 3 knockouts back cable entry, connection via RS485 control panel network, 24 programmable function buttons,operating voltage 18-32 Vdc, rated voltage 24 Vdc, Alarm current 120 mA, Ambient temprature 5 to 45 deg celcius,approved by LPCB complete all as directed by Engr-in-Charge.
Excavation in trenches in hard/dense soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, foundation, etc or for shaft well, cesspits, manholes, pierholes, etc not exc 10 Sqm plan and getting out in soft/loose soil complete all as specified and directed at site.
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested , poles, stays, struts have been erected and tested all as specified and directed at site.
Removing excavated surplus soil (Soft/Loose soil) obtained from exavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 m above the starting point all as specifed and directed.
Material and labour for sand cushioning with a layers of dry clean Ganga river sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. Note: Punned thickness 18 cm shall only be measured.
Supply and laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other for cable protection complete all as specified and directed.
M&L for boring of holes under road/drain/PCC path by manual method for inserting upto 40 mm dia light GI tubing for cable protection in minimum 60 mm depth from normal ground level all as specified and directed.
Supply and laying 40 mm dia GI tubing light grade complete with all fittings (ISI Marked) laid in trenches/fixed complete to wall and ceiling or laid in floors, trenches, under road crossing, fixed on poles/walls for cable protection all as specified.
M&L for fixing of LT cable route indicator aluminium cast material, 100 mm dia, round with 5-6 mm thick, two hole for mounting, 3 mm Embossed letter as appropriate, including stand of made out of angle iron of size 40 x 40x 6mm thick of length 90cm (60 cm above ground level) as directed and to be grouted 2 feet from the ground level including all excavation and earth work complete all as specified and directed.
M & L for false ceiling with Semi perforated 12mm thick micro tegular edged GRG false ceiling tiles at all height (Minimum 4m height) with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture,design & patterns having moisture content less than 2%, humitidy resistance of 99%, NRCO 0.50 to 0.75 as per IS 8225: 1987 , non combustible as per BS 476 (Part4) - 1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120grams per sqm including both sides) comprising of main T-runners of size 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermideate T of size 15x32 mm of length 600 mm to form grid module of size 600x 600 mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 gram per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and L shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 25 x 25x 0.40 mm of length 3000 mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450 mm center to centre and 40 mm long dry wall wood screws. The work shall be carried out as per specification, drawings and as per direction of the Engr-in-Charge.
S & F rolled mild steel joist, channel, angle, tee or hollow sections, fixed independently or support for holding ceiling as required confirming to grade E-250 (Fe-410W quality) of any size and shape complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
NOTE applicable for item no 1 to 7,10 to 14: Contractor shall provide guarantee for flame proof items as per OEM but not less 02 years from the actual date of completion.
DARSHAN CONSTRUCTION Co.
OM INFRA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .