| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 CrAccepted-AOC | ₹7.5 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹7.5 Cr+₹1.0 L (0.14%)Rejected-AOC 1027 SECTOR 21B CHANDIGARH 160022 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160022 | ₹7.5 Cr+₹1.0 L (0.14%) | L2 | Rejected-AOC Not Lowest |
| 3 | L3₹7.8 Cr+₹26.4 L (3.52%)Rejected-AOC | ₹7.8 Cr+₹26.4 L (3.52%) | L3 | Rejected-AOC Not Lowest |
| 4 | L4₹7.8 Cr+₹28.8 L (3.85%)Rejected-AOC | ₹7.8 Cr+₹28.8 L (3.85%) | L4 | Rejected-AOC Not Lowest |
| 5 | L5₹7.8 Cr+₹30.4 L (4.06%)Rejected-AOC | ₹7.8 Cr+₹30.4 L (4.06%) | L5 | Rejected-AOC Not Lowest |
Tender Value
Refer Docs
EMD Value
₹7.6 L
Closing Date
3 Mar 2021, 6:00 pmClosed
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
As described in Sch or Works, shown on drgs and as specified
2020_MES_339224_1
80993/E8
Open Tender
Civil Works
Item Rate
640 days
Jalandhar Cantt
All documents as per NIT
8 documents required · 8 mandatory
₹3,000
Garrison Engineer (East) Jalandhar
₹7.6 L
Yes
25 Mar 2021
15 Jan 2021
5 Mar 2021
15 Jan 2021
3 Mar 2021
22 Feb 2021
15 Jan 2021 - 16 Feb 2021
Amount
Note: (i) Please refer Schedule 'A' Notes given on serial page No. 22(R), 23, 24(R), 25, 26(R) of tender documents. (ii) Item from Srl No. 3.00 to 7.11 of this document shall be Part-XIII (Miscellaneous items) of BOQ.
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule 'A' Part-I brought forward from serial page No. 27
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-II brought forward from serial page No. 28
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 29
Lump sum price worked out by the contractor for ROAD, PATH, CULVERTS AND HARDSTANDING WORKS as listed in Schedule 'A' Part-IV brought forward from serial page No. 31(R)
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS listed in Schedule 'A' Part-V brought forward from serial page No. 32(R)
Lump sum price worked out by the contractor for RAIN WATER HARVESTING WORKS listed in Schedule 'A' Part-VI brought forward from serial page No. 34(R)
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-VII brought forward from serial page No. 37
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-VIII brought forward from serial page No. 38
Lump sum price worked out by the contractor for FIRE FIGHTING WORKS as listed in Schedule 'A' Part-IX brought forward from serial page No. 40(R)
Lump sum price worked out by the contractor for DISMANTLING AND DEMOLITION WORKS as listed in Schedule 'A' Part-X brought forward from serial page No. 41(R)
Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTH WORKS as listed in Schedule 'A' Part-XI brought forward from serial page No. 42(R)
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Part-XII brought forward from serial page No. 42-B
INTERNAL ELECTRIFICATION WORKS
Material and labour for concealed point wiring for one light point/bell point controlled by one switch complete with 1.5 sqmm (nominal cross sectional area) FRLS PVC insulated multi-stranded copper conductor in and including suitable size heavy duty non-metallic rigid PVC conduit (ISI marked) including fittings & accessories including MS concealed terminal boxes with 3mm thick plastic laminated bakelite (Hylum) sheet top cover for mounting switch socket etc including 1.5 sqmm FRLS PVC copper conductor multi-stranded as earth wire connected to the common earth dolly complete all as specified and directed. Note;- (i) Switches, sockets, lamp holder, ceiling rose, bell, light fittings shall be measured and paid for separately. (ii) Cutting chases shall be carried out by using electrically operated mechanical cutter and the cost thereof shall deemed to be included in lump sum cost of respective building.
All as per description of srl item No. 3.01 above but for one fan point controlled with switch and regulator
All as per description of srl item No. 3.01 above but for one 3 pin socket outlet 5 Amp on same board.
All as per description of srl item No. 3.01 above but for one 3 pin socket outlet 5 Amp on independent board.
All as per description of srl item No. 3.01 above but for 3 pin, 15 Amps socket outlet with 2.5 sqmm copper conductor cable as main wiring & earth wire.
Material and labour for sub main wiring with 04 single core FRLS PVC insulated stranded copper conductor 4 Sqmm and 02 run of 4 Sqmm for earth continuous earth wire inlcuidng 25mm dia PVC rigid non-metallic conduit medium grade ISI marked all as specified and directed. Note : 04 runs of PVC cable 4 sqmm & 02 runs of earth wire 4 sqmm with 01 run of PVC conduit shall be considered as one unit.
Supply and fix ceiling fan 1200mm sweep AC single phase 230 V, 50 Hz, copper wound, with BLDC technology, max power input upto 26 to 32 watt, copper wire motor with 5 star BEE rating complete alongwith canopy cover and remote control, down rod, U clamp, electronic regulator 2 module heavy duty including provision of cord flexible copper conductor 23/0.0076 three core from ceiling rose to connector complete all as specified and directed.
Supply and fix exhaust fan 450 mm sweep, 1400 rpm, single phase, 230 volt, heavy duty, metalic body with lovered shutter including provision of three core flexible cable of required length of size 23/.0076 from ceiling rose/ connector to fan terminal, fixing the fan on wall with suitable size of nuts, bolts & washers complete all as specified and directed. Note: Cost of opening in wall and grouting of bolts shall be deemed included in the lump sum cost of the building.
Supply and fix exhaust fan 300 mm sweep, 900 rpm, single phase, 230 volt, heavy duty, metalic body with lovered shutter including provision of three core flexible cable of required length of size 23/.0076 from ceiling rose/ connector to fan terminal, fixing the fan on wall with suitable size of nuts, bolts & washers complete all as specified and directed. Note: Cost of opening in wall and grouting of bolts shall be deemed included in the lump sum cost of the building.
Supply and fixing MCB, SP 240 volts, capacity 6 - 32 Amps, 'B' series 50 Hz, 10 KA complete all as specified and directed.
Supply and fixing MCB, SPN 240 volts, capacity 6 - 32 Amps, 'B' series 50 Hz, 10 KA complete all as specified and directed.
Supply and fixing MCB, TP, 415 volts, capacity 40 Amps, 'B' series 50 Hz, 10 KA complete all as specified and directed.
Supply and fix energy saving LED Luminaries comprising of extruded aluminum housing high quality PC diffuser, reliable and robust housing structure, Slim integrated design easy to install ,100 Lumens /Watt 4 feet ,18 watt to 20 watt 124 volts AC supply to be fixed on PVC square boxes (02 No) complete prewired including connection & testing complete all as specified and directed.
Supply and fix energy saving & environment friendly, long life versalite, pressure die-cast aluminium luminaire with high power 25 watt 5700 K LEDs Bldg security lights as light source and high efficiency electronic driver having IP 65 protection (min), surge protection, power factor more than 0.9 complete pre-wired and product should be made in India only including bracket made out of GI pipe 32 mm dia medium grade bent to shape and clamp 40 x 6 mm with nuts and bolts including connection & testing complete all as specified and directed.
Supply and fix LED Lamp 10 W Adore 6500 K, B 22 CDL Ball Lamp Cat Part No. LEDZ BULB 9 WCDL B 22 Bajaj or equivalent in HAVELLS / Crompton Greaves
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth lead GI wire 4mm dia (8 SWG) connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron light grade 15mm bore and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete (1:3:6) type C-1 & RCC cover in M-20 (Design mix) reinforced with 8mm dia TMT bars @ 15cm c/c both ways and all as shown in Electrical Plate No 3 of MES standard Schedule of Rates (Part-I) of 2009 complete all as specified and directed. Notes : (i) Outer edge of earth pit shall be 1 m away from the outer edge of PCC chamber. (ii) GI earth wire form earth elctrode test point upto 7.5 metre is included in this item. (iii) Water pipe shall be provided in slanting position. (iv) Earthing work shall be carried out in the presence of Engineer-in-Charge or the rep detailed by him. (v) In case the desired test result of earthing not found satisfactory, contractor shall re-carry out the earth work at new location without any extra cost to the deptt.
RAIN WATER HARVESTING WORKS
Trial Boring holes for 300 mm dia in normal available strata upto 50 m depth by mechanical mehod including removal of surplus soil to a distance n. exc 50 metre complete all as specified and directed.
All as per description of item No. 4.01 here-in-before but depth exceeding 50 metre but not exceeding 75 metre
Supply and fix PVC pipe 150 mm bore class 'A' of pressure rating 6Kg/cm² including all necessary fitting complete all as specified and directed.
Supply and fix perforated/slotted PVC pipe 150 mm dia class 'A' including all necessary fittings complete all as specified and directed.
Material and labour for pea gravel packing including jute cloth as filter media 3mm to 5mm size around PVC pipe complete all as specified and directed.
Material and labour for filling pea gravel in RWH of size 12.5mm coarse aggregate upto a height of 0.50 metre complete all as specified and directed.
Material and labour for filling pea gravel in RWH of size 3mm to 5mm upto a height of 0.50 metre complete all as specified and directed.
Material and labour for filling coarse sand in trenches upto a height of 0.50metre complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY WORKS
Supply, install, testing and commissioning step down distribution transformer 200 KVA, copper wound, Outdoor type, 11000/433 volt, 3 phase, 4 wire, 50 cycles, naturally oil cooled type, suitable for outdoor installation, connected delta on HV side and star on LV side with neutral brought out LT side with solid earthing system with off load tap changing switch on HT side to vary secondary voltage upto +7.5 % in steps of 2.5% each with in limit and with standard accessories like oil temperature with indicator for highest temperature gauge, silica gel, breather assembly, oil conservator tank with oil filling hole duly plugged, with bare HV and LV bushings, CI roller wheel, lifting lugs, explosion vent, air release plug, earthing terminals, oil drain valve of gun metal with plug, oil filter valve with plug, name rating and diagram plate, oil level indicator and arching horn set and other fittings/ accessories and for standard requirement first fill oil all as per IS:1180 EEL3 (with upto date amended) including connections complete all as specified and directed. Note :- (i) Pre-commissioning test shall be carried out by the SEI for which all arrangements shall be made by the contractor without any extra cost. (ii) Standard connected accessories/ fittings in addition to above as required shall be provided and cost of same is deemed to be included in the quoted rate. (iii) Contractor will submit technical specification from approved manufacturer comprising of the above specifiecation to GE and take approval before palcing order. connections complete all as specified.
Supply and fixing lightening arrester metal oxide type complete with all fittings, transmission class, discharge capacity 65 kilo amp as per IEC 99.4 effectively earthed complete suitable for 11 KV, HT over head line complete including nuts, bolts, clamps, bracket etc and connecting with GI earth wire, complete all specified and directed
Material and labour for boring hole under the road / pavement / hard standing including HDPE pipe of 150mm dia at a depth not less than one metre below ground level complete all specified and directed
Material & labour earthing complete for transformer / LT panels with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode GI strip 32 x 6mm connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth strip connected to test point and protected by galvanized iron medium grade 50mm bore and GI pipe 20mm bore light grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC chamber in cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate and RCC cover in M-25 (Design mix) and all as shown in Electrical Plate No. 3 of MES Schedule (Part-I) of 2009 complete all as specified and directed. Notes : (i) Outer edge of earth pit shall be 1 m away from the outer edge of PCC chamber. (ii) GI earth strip for earth elctrode test point upto 7.5 metre is included in this item. (iii) Water pipe shall be provided in slanting position. (iv) Earthing shall be carried out in the presence of Engineer-in-Charge or the rep detailed by him. (v) In case the desired test result of earthing not found satisfactory, contractor shall re-carry out the earth work at new location without any extra cost to the deptt.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth lead GI wire 4mm dia (8 SWG) connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron medium grade 15mm bore and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete (1:3:6) type C-1 & RCC cover in M-20 (Design mix) and all as shown in Electrical Plate No 3 of MES standard Schedule of Rates (Part-I) of 2009 complete all as specified and directed. Notes : (i) Outer edge of earth pit will be 1m away from the outer edge of PCC chamber and the cost of additional earth lead, protection pipe shall be deemed included in unit quoted rate. (ii) GI earth wire form earth elctrode test point upto 7.5 metre is included in this item. (iii) Water pipe shall be provided in slanting position. (iv) Earthing shall be carried out in the presence of Engineer-in-Charge or the rep detailed by him. (v) In case the desired test result of earthing not found satisfactory, contractor shall re-carry out the earthing at new location without any extra cost to the deptt.
Supply & install High mast pole 12.5 mtr High 12 sided polygon having hot dip galvanising as per IS, tubuler structure with BS EN 10025 as per IS-2062,in two section longitudinal and welded in one section with thickness of sheet 3mm at top and 3mm at bottom suitable for wind velocity as per IS-875 (part-3) 1987 with lightning protection finial GI with single spike of 1200 mm long with accessories, LED type double aviation obstructions lights including wiring & connection and including necessary excavation, returning filling, removal of soil from site all and PCC foundation of high mast light as per manufacturer design having door opening of size 900mm x 250mm at base with close fitting door with allen key locking with base plate of size 520mm dia 25 mm thick (min) with 06 Nos foundation bolts of M24 and 750 mm long with PCD 750 mm including lantern carriage of ERW class-B MS Pipe NB 40 in round shape 600 mm (ID) with 6 arms duly welded having load carrying capacity 6 luminairies and accessories with double drum 2 winch of capacity 350 Kg (SWL)having motorised opearation with manual mode with control gear assembly with self lubricating in permanent oil bath including first fillof lubricant SAE-90/140 with two stainless steel wire rope 7/19 of 6 mm dia of grade AISI 316 provided with suitable thimbles and terminals with minimum breaking capacity 2350 Kg per rope including integral power tool suitable to operate on AC 440 Volts/240 Volts electric supply, single speed reversible type and trailing electric cable flexible with stranded copper conductor 2.5 sqmm 5 core having EPR/PVC insulated and PCP/PVC sheath IS marked complete all as specified and directed.
S&F energy saving LED flood light fitting 120 watt made of pressure die-cast aluminium housing LED efficiacy >100lm/watt Potted isolated driver and high power LED and individuals secondary lences with operating range -90 volts to 340 volts Fixture should with stand 320 V upto 48 Hrs Auto cut off >320 V and restart 440 volts, sustain upto 8 Hrs . Brand name should be engraved on fixture to ensure Indian brand only, fixed to high mast 12.5 metre long complete all as specified and directed. Notes: (i) All LED fitting shall be made in India only. (ii) Contractor shall provide 2 years written manufacturer’s warranty for the LED fixture complete including driver from the certified date of completion. (iii) Contractor shall be produce LM-79 & LM-80 report of NABL accredited laboratory from third party.
Supply and fix bracket made out of 40 mm bore GI medium grade tube 1.5 metre long, including cutting, welding and bent to shape at 120 degree angle, fixed with clamps nuts and bolts, washer complete all as specified (Note: Clamps, nut, bolts and washers will be measured and paid separately).
Supply and fixing LT Cable junction box environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive, made of Polycarbonate with glass fiber reinforced, and size not less than 255mm x 205mm x 112 mm (upto Cable Size 25sq.mm), rated for Degree of ingress Protection IP 66/69 in accordance with IEC 60529.Weatherproof UV-resistant, rainwater-proof, temperature-resistant. The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall complies with requirements of the standards IEC 60998 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5. The Junction Box Black Colour according to RAL 9011. The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate . For better safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 degree Centigrade & Current Carrying Capacity upto 102Amps. The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechanical load shall be in accordance with EN 50298 - 98 for IK 08 including one No. 4 pole connector and one no. MCB SP 'C' curved 6/10 Amp 9/10KA and chromium plated clamps and nut bolts complete all as per manufacturer’s instructions. Make : Cat Part :- KF 2525 B of Hensel or equavalent of /Siemens/Rittal.
Supply and fixing factory made LT panel box, outdoor type, vermin proof, made CRCA MS sheet 3.15mm thick, machine pressed, with 900mm long supports of angle iron 50mm x50mm x 6mm, 50cm of legs grouted in PCC 1:2:4 type B-1 below floor / ground, double door hinged type front and rear including locking arrangement, 415 volts AC 50 Hz, duly powder coated with 7 tank process, making connections for incomimg and outgoung with necessary wiring, proper lugs / thimbles and comprising of the following :- (A) Bus bar copper strip 30x10mm, four pole and capacity 450 Amps coloured with plastic coated insulation and sleeves in four colours (Red, Yellow, Blue & Black) fixed on insulators with necessary nuts and bolts and washers etc including wiring of panel accessories with suitable size of copper conductor cable, thimbles etc. (B) INCOMING :- (i) MCCB of current rating 315 Amp, 4 pole 415 volt, 36 KA rupturing capacity with thermal release, ICS=ICU=100% -01 No. (ii) 3 phase multi function meter with LCD display, accuracy class 1.0, having parameters KW, KWH, KVAh, PF, duly pre-wired with suitable size of FRLS insulated copper wire with universal code including suitable CTs complete - 01 No. (iii) Phase Indicator neon lamp RYB with MCBs -01 Set of 3 (C) OUTGOING:- (i) MCCB of current rating 160 Amp, 4 pole 415 volt, 25 KA rupturing capacity with thermal release, ICS=ICU=100% -03 No (ii) MCB 32 Amp Four pole 415 Volt, 10KA - 01 No. (iii) MCB 32 Amp Two pole 230 Volt, 10KA - 03 No. (iv) Onload changeover switch in open execution type, 250A - 01 No.
Supply and fixing factory made Feeder panel box, outdoor type, vermin proof, made CRCA MS sheet 3.15mm thick, machine pressed, with 900mm long supports of angle iron 50mm x50mm x 6mm, 50cm of legs grouted in PCC 1:2:4 type B-1 below floor / ground, double door hinged type front and rear including locking arrangement, 415 volts AC 50 Hz, duly powder coated with 7 tank process, making connections for incomimg and outgoung with necessary wiring, proper lugs / thimbles and comprising of the following :- (A) Bus bar copper strip 20x10mm, four pole and capacity 300 Amps coloured with plastic coated insulation and sleeves in four colours (Red, Yellow, Blue & Black) fixed on insulators with necessary nuts and bolts and washers etc including wiring of panel accessories with suitable size of copper conductor cable, thimbles etc. (B) INCOMING :- (i) MCCB of current rating 160 Amp, 4 pole 415 volt, 25 KA rupturing capacity with thermal release, ICS=ICU=100% -01 No. (ii)3 phase multi-function meter with LCD display, accuracy class 1.0, having parameters KW, KWH, KVAh, PF, duly pre-wired with suitable size of FRLS insulated copper wire with universal code including suitable CTs complete - 01 No. (iii) Phase Indicator neon lamp RYB with MCBs -01 Set of 3 (C) OUTGOING:- (i) MCCB of current rating 63 Amp, 4 pole 415 volt, 16 KA rupturing capacity with thermal release, ICS=ICU=100% -05 No (ii) MCB 32 Amp Two pole 230 Volt, 10KA - 03 No.
Supply and fixing factory made Feeder panel of size 600mm x 500mm x 400mm, outdoor type, vermin proof, made CRCA MS sheet 3.15mm thick, machine pressed, with 100cm long supports of angle iron 40mm x40mm x 6mm, 50cm of legs grouted in PCC 1:2:4 type B-1 below floor / ground, double door hinged type front and rear including locking arrangement, 415 volts AC 50 Hz, duly powder coated with 7 tank process, making connections for incomimg and outgoung with necessary wiring, proper lugs / thimbles and comprising of the following :- (i) MCB 40 Amp TPN, 415 Volt, 'C' Curve, 10KA - 01 No. (ii) MCB 32 Amp TPN, 415 Volt, 'C' Curve, 10KA - 01 No. (iii) MCB 10 Amp SP 230 Volt, 'C' Curve, 10KA - 04 No (iv) Astronomical timer - 01 No. (v) 4 pole contactor 415V - 01 No. (vi) Rotory switch of motor for moving up / down the lantern carriage - 01 No.
S&F LED street light luminarie 60 watt in epoxy powder coated pressure die-cast aluminium With potted isolated driver and high power LED and individual lences operating range -90 volts to 340 volts Fixture should with stand 320 v upto 48 Hrs Auto cut off >320 v with inbuilt SPD -10 KV. Brand name should be embossed on fixture to ensure Indian brand only complete all as specified and directed. Notes: (i) LED fittings shall be made in India only. (ii) Contractor shall provide 2 years written manufacturer’s warranty for the LED fixture complete including driver from the certified date of completion. (iii) Contractor shall be produce LM-79 & LM-80 report of NABL accredited laboratory from manufacturer's local office. .
Material and labour for sub main wiring with 2 runs of single core FRLS PVC insulated stranded copper conductor 2.5 Sqmm and 01 run of 2.5 Sqmm for earth continuous earth wire in and including 20mm dia rigid non-metallic PVC conduit all as specified and directed. Note : 02 runs of PVC cable 2.5 sqmm & 01 runs of earth wire 2.5 sqmm with 01 run of PVC conduit shall be considered as one unit.
Supply and fix time switches astro type (having longitude and latitude of Indian cities in memory) Three phase of 16 Amp rating Power Contactor(AC 3) 16 Amps with digital timer switch and MCBs TPN (Input-Output) 16 Amp should be enclosed Make Indoasain Cat part No TL016 or equalent to C&S Electric/L&T/Havells
EXTERNAL WATER SUPPLY WORKS
Material & labour brick masonry valve pit of size 90 cm x 90 cm x 90 cm (internal size) with cover of mild steel sheet 3 mm thick and angle iron frame of size 40mm x40mm x 6mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including locking arrtangement, brick work built in cement mortar 1:4 external surfaces in contact with earth pointed flush with same mortar as the work proceeds and all inner and exposed suraces of pit plastered with 15mm thick in cement mortar 1:4 and painted with three coats of white wash, 100mm thick PCC base / foundation 1:4:8, type D-2, using 40mm graded crushed stone aggregate, PCC bed plate 100mm thick on top of wall complete all as specified and directed.
Material & labour for Cutting the existing CI / DI pipe line 150 mm / 200mm dia for making branch connection of GI pipe of 80 mm including provision of 150 x 150 x 80 mm / 200 x 200 x 80 mm tee along with lead joints and connected earth work all as specified and directed.
FIRE FIGHTING WORKS
Supply, installation, commissioning and testing of Automatic motor control LT indoor panel board (factory made of approved CPRI) not less than 150 cm x 100 cm x 50 cm mounted indoor type made out of CRCA sheet 2 mm thick dust proof, powder coated from both side, individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply including bus bar chamber and copper bus bar of capacity 200 Amps rating for phase and neutral mounted on hygroscopic insulator fixed in a separate bus bar chamber separate compartment for incoming and outgoing feeder prewired with suitable size of copper conductor cable including fitted on 50x50x6mm angle iron channel with PCC foundation and provision of lugs and bushing for housing the following :- (i) Electrolite copper bus bar 250 amps for phase & neutral-04 Nos (ii) MCCB 4P 160 Amps, 25 KA- 01 Nos (iii) MCCB 4P 100 Amps, 25 KA- 02 Nos (iii) MCCB 4P 40 Amps, 16 KA - 02 Nos (v) Automatic star delta starter with D range contactor and rubsta 60 HP- 02 Nos (vi) DOL starter with D range contactor and LR1D OLR in SS encloser 5 HP- 02 Nos (vii) Multi functional digital Voltmeter and ampere meter including suitable and appropriate CTs-01 Set (viii) Indicator lamp (LED R-Y-B)- 07 Set
Supply, laying, jointing and testing in trenches 100mm bore ductile iron pipes with spigot and socketed ends class ‘K-9’ in any length all as per IS 8329/2000 including rubber gasket joints including testing all as specified and as directed. Note :- (i) Excavation, Earth work and DI fittings shall be measured and paid for separately under respective items. (ii) Cost of Rubber tyton joints is included in rate quoted (iii) Standard length of pipe shall be 5.50 metre or 6.0 metre as available (iv) The measurement of pipes shall be net as fixed between the fittings including short lengths without any allowance for cutting and wastage and for the portion entering in the sockets of pipes and fittings.
Supplying, fixing, fire hose cabinate box for hose reel of size 20 mm of 30 Mtr length, made out from 16 gauge MS sheet with double leafed glazed shutters (glazed with 4 mm thick glass ) complete with coupling branch pipe and nozzles complete all as specified and directed.
S&F fire hose reel , wall mounted swivel type fitted with 30 mtr long ,20 mm dia ,high pressure dunlop hose conforming to IS: 5132 with 15 mm dia outlet , gun metal nozzle with shut off valve as per IS 884- 1969 complete all as specified and directed.
Supply and fix siren electric motor operated conforming to IS 1941 suitable for three phase 415 volt with motor not exceeding 3.78 KW power and able to deliver 143 DB noise level siren will have a automatic equipment for producing a warning noise of range 1000 meter complete all as specified and directed.
Supply & fix Cast Iron Reflux Valve 100 mm bore with bypass arrangement supplied and installed complete all as specified and directed.
Supplying & erecting 4 Loop Analogue Addressable Fire Alarm Control Panel with 80 Character Backlit LCD Display, built in PSU with battery charger, including 250 Watts amplifier with appropriate ohms & microphone for public address system complete all as specified and directed.
Material and labour for ductile iron fittings ISI marked such as coupling, bends, elbow, and tee etc, screwed joint complete all as specified and directed.
Supply and laying, jointing and testing Control Copper Cables,Solid Copper Conductor of size 1.5 Sqmm, 2 core , XLPE Insulated, with Inner sheathed Armoured laid in trenches / fixed to wall complete all as specified and directed
S&F Analogue addressable fault isolator module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected complete all as specified and directed. Make : Honey well/Spencer Fire/ETS
S&F addressable manual call point resettable type complete all as specified and directed.
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .