Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹32.3 LAccepted-AOC | ₹32.3 L Quoted ₹30.0 L | 1 | Accepted-AOC Work order issued |
| 2 | 2₹37.0 L+₹7.0 L (23.4%)Rejected-Finance | ₹37.0 L+₹7.0 L (23.4%) | 2 | Rejected-Finance Not L1 bidder |
| 3 | 3₹37.1 L+₹7.1 L (23.7%)Rejected-Finance D 5 C C COLONY DELHI 7 | NORTH | DELHI | 110006 | ₹37.1 L+₹7.1 L (23.7%) | 3 | Rejected-Finance Not L1 bidder |
| 4 | 4₹37.4 L+₹7.4 L (24.7%)Rejected-Finance | ₹37.4 L+₹7.4 L (24.7%) | 4 | Rejected-Finance Not L1 bidder |
| 5 | 5₹41.6 L+₹11.6 L (38.5%)Rejected-Finance EPROCUREMENT SYSTEM FOR CENTRAL PSUS | ₹41.6 L+₹11.6 L (38.5%) | 5 | Rejected-Finance Not L1 bidder |
| Sl No | Description | Qty | Unit | M/S RAJ ENTERPRISES L2 | BABA THADESARI BUILDERS L4 | RAJENDER KUMAR GUPTA L3 | SEHWAG CONSTRUCTION COMPANY L1 | M/s. Ram Prakash L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00Laying and Jointing PVC Pipe. Heading | ||||||||
| 1.01 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor
single core cable in surface/ recessed medium class PVC conduit along with 1 No 4
sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as
required. | 47 | metre | 334 ₹15,698 | 334 ₹15,698 | 334.25 ₹15,709.75 | 330 ₹15,510 Lowest | 334.25 ₹15,709.75 |
| 1.02 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of
FRLS PVC insulated copper conductor, single core cable in surface / recessed
medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire | 270 | metre | 233 ₹62,910 Lowest | 233 ₹62,910 Lowest | 233.09 ₹62,934.3 | 250 ₹67,500 | 233.09 ₹62,934.3 |
| 1.03 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of
FRLS PVC insulated copper conductor, single core cable in surface / recessed
medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 46 | metre | 275 ₹12,650 | 276 ₹12,696 | 275.23 ₹12,660.58 | 270 ₹12,420 Lowest | 275.23 ₹12,660.58 |
| 1.04 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of
FRLS PVC insulated copper conductor, single core cable in surface / recessed
medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire | 38 | metre | 439 ₹16,682 | 439 ₹16,682 | 439.1 ₹16,685.8 | 435 ₹16,530 Lowest | 439.1 ₹16,685.8 |
| 1.05 | Supplying and fixing following modular switch/ socket on the existing modular plate
& switch box including connections but excluding modular plate etc. as
required.5/6 amps switch | 20 | each | 102 ₹2,040 | 102 ₹2,040 | 102.84 ₹2,056.8 | 100 ₹2,000 Lowest | 102.84 ₹2,056.8 |
| 1.06 | Supplying and fixing modular blanking plate on the existing modular plate &
switch box excluding modular plate as required. | 2 | each | 40 ₹80 | 40.46 ₹80.92 | 40.46 ₹80.92 | 35 ₹70 Lowest | 40.46 ₹80.92 |
| 1.07 | Supplying and fixing following size/ modules, GI box alongwith modular base &
cover plate for modular switches in recess etc as required.8 Module
(125mmX125mm) | 2 | each | 454 ₹908 | 454 ₹908 | 454.33 ₹908.66 | 430 ₹860 Lowest | 453.33 ₹906.66 |
| 1.08 | Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket
outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be
used in non residential buildings). | 1 | each | 477 ₹477 | 477 ₹477 | 477.7 ₹477.7 | 400 ₹400 Lowest | 477.08 ₹477.08 |
| 1.09 | Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps
modular socket outlet and 15/16 amps modular switch, connection etc. as required. | 3 | each | 585 ₹1,755 | 585 ₹1,755 | 585.7 ₹1,757.1 | 550 ₹1,650 Lowest | 585.7 ₹1,757.1 |
Tender Value
₹51.9 L
EMD Value
₹1.0 L
Closing Date
6 Jan 2025, 3:00 pmClosed
Executive Engineer (EMS)/SZ
Office of the Executive Engineer (EMS)/SZ, Green Park, New Delhi-110016
Providing civil structure for fixed compactor transfer station (FCTS), at dhalao Auto market, Zamrudpur, Greater Kailash, Ward No. 173, South Zone.
2024_MCD_222212_1
EE (EMS)/SZ/TC/2024-25/04-02
Open Tender
Civil Works
Percentage
90 days
Greater Kailash
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
₹1.0 L
16 Jul 2026
1 Jan 2025
6 Jan 2025
1 Jan 2025
6 Jan 2025
1 Jan 2025
Amount
Laying and Jointing PVC Pipe. Heading
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 30 KA, FPMCCB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Supplying and fixing 20 amps 415volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps "C" curve, TPMCB, in sheet enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator6 way, Double door
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*25 sqmm
SITC of 30W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =30 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
SITC of 60W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
Supply of 1200 mm sweep 50 watt, Energy saver ISIS marked BEE 5 star rating AC Ceiling fan suitable for 230 V , 50 Hertz AC supply without regulator with blades, downrod etc. complete as required.
Supply of 18"(450 mm ) sweep 1400 rpm exhaust fan heavy duty complete with shutter blade etc as required
Providing and fixing circular / hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing .
Bidder Name
Amount
M/S RAJ ENTERPRISES (GSTN-07ACMPT3143K1Z7) BID ID -803713
BABA THADESARI BUILDERS (GSTN-NA) BID ID -803933
RAJENDER KUMAR GUPTA (GSTN-NA) BID ID -803951
SEHWAG CONSTRUCTION COMPANY (GSTN-NA) BID ID -803117
M/s. Ram Prakash (GSTN-NA) BID ID -803707
M/S RAJ ENTERPRISES (BID ID -803713)
BABA THADESARI BUILDERS (BID ID -803933)
M/s. Ram Prakash (BID ID -803707)
RAJENDER KUMAR GUPTA (BID ID -803951)
M/S RAJ ENTERPRISES (BID ID -803713)
RAJENDER KUMAR GUPTA (BID ID -803951)
BABA THADESARI BUILDERS (BID ID -803933)
M/s. Ram Prakash (BID ID -803707)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .