Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹1.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.8 Cr+₹38.2 L (27.3%)Rejected-AOC | ₹1.8 Cr+₹38.2 L (27.3%) | L2 | Rejected-AOC L2 |
| 3 | L3₹1.9 Cr+₹46.2 L (33.1%)Rejected-AOC VILLAGE BATWAL SUB TEHSIL BARWALA NEAR RAIPUR RANI DISTT PANCHKULA 134204 | YAMUNANAGAR | HARYANA | 134204 | ₹1.9 Cr+₹46.2 L (33.1%) | L3 | Rejected-AOC L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical REJECTED DUE TO THREE CLASS BELOW ELIGIBLE CLASS |
| 5 | Rejected-Technical | - | - | Rejected-Technical REJECTED DUE TO NO REMARKS IN CE SWC WLR |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
27 Dec 2021, 6:00 pmClosed
SH A P SINGH, IDSE
HQ CWE CHANDIMANDIR
CA NO CWE/CHM(U)-64/2021-22 PROVN OF LT UG CABLE INCL CONVERSION OF OVERHEAD CONDUCTORS WITH UG CABLE IN SECTOR C, SECTOR E, MES COLONY, DDGSI AREA AND CERTAIN MISC LOCATIONS AT CHANDIMANDIR
2021_MES_487942_1
CWE/CHM(U)-64/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE CHANDIMANDIR
CLASS B CAT b(i)
8 documents required · 8 mandatory
₹2,000
Yes
GE (U) CHANDIMANDIR
₹2.2 L
Yes
16 Feb 2022
12 Nov 2021
3 Jan 2022
12 Nov 2021
27 Dec 2021
13 Dec 2021
Amount
Dismantling of old ACSR conductors and earth wire of any size and removing material from the Site complete all as specified and as directed.
Dismantling of old cross arms of MS channel or angles sections flats;nuts bolts washers, insulators etc and removing the materials from the Site, complete all as specified and directed.
Excavating in trenches, for foundation of poles, stays or for laying of cables, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed.
Removing excavated material (soil) n.exc.50m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover, Class LV, type -I, flat size 250 x 150 x 40 mm complete all as specified and directed.
M & L for sand cushioning for protection of cable (below, above and around the cable laid in trenchs) all as specified and as directed.
Supply, laying, jointing and testing LT underground cable XLPE insulated and armoured and PVC sheathed 1100 volts grade, heavy duty with multistranded aluminum conductor of size 16 sqmm 2 core laid in trenches/ducts/along poles/through pipe under road etc with new aluminum lugs complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing LT underground cable XLPE insulated and armoured and PVC sheathed 1100 volts grade, heavy duty with multistranded aluminum conductor of size 16 sqmm 4 core laid in trenches/ducts/along poles/through pipe under road etc with new aluminum lugs complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing LT underground cable XLPE insulated and armoured and PVC sheathed 1100 volts grade, heavy duty with multistranded aluminum conductor of size 25 sqmm 4 core laid in trenches/ducts/along poles/through pipe under road etc with new aluminum lugs complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing LT underground cable XLPE insulated and armoured and PVC sheathed 1100 volts grade, heavy duty with multistranded aluminum conductor of size 35 sqmm 4 core laid in trenches/ducts/along poles/through pipe under road etc with new aluminum lugs complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing LT underground cable XLPE insulated and armoured and PVC sheathed 1100 volts grade, heavy duty with multistranded aluminum conductor of size 50 sqmm 3.5 core laid in trenches/ducts/along poles/through pipe under road etc with new aluminum lugs complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing LT underground cable XLPE insulated and armoured and PVC sheathed 1100 volts grade, heavy duty with multistranded aluminum conductor of size 70 sqmm 3.5 core laid in trenches/ducts/along poles/through pipe under road etc with new aluminum lugs complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing LT underground cable XLPE insulated and armoured and PVC sheathed 1100 volts grade, heavy duty with multistranded aluminum conductor of size 95 sqmm 3.5 core laid in trenches/ducts/along poles/through pipe under road etc with new aluminum lugs complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing LT underground cable XLPE insulated and armoured and PVC sheathed 1100 volts grade, heavy duty with multistranded aluminum conductor of size 120 sqmm 3.5 core laid in trenches/ducts/along poles/through pipe under road etc with new aluminum lugs complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing LT underground cable XLPE insulated and armoured and PVC sheathed 1100 volts grade, heavy duty with multistranded aluminum conductor of size 150 sqmm 3.5 core laid in trenches/ducts/along poles/through pipe under road etc with new aluminum lugs complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing LT underground cable XLPE insulated and armoured and PVC sheathed 1100 volts grade, heavy duty with multistranded aluminum conductor of size 185 sqmm 3.5 core laid in trenches/ducts/along poles/through pipe under road etc with new aluminum lugs complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing LT underground cable XLPE insulated and armoured and PVC sheathed 1100 volts grade, heavy duty with multistranded aluminum conductor of size 240 sqmm 3.5 core laid in trenches/ducts/along poles/through pipe under road etc with new aluminum lugs complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing LT underground cable XLPE insulated and armoured and PVC sheathed 1100 volts grade, heavy duty with multistranded aluminum conductor of size 300 sqmm 3.5 core laid in trenches/ducts/along poles/through pipe under road etc with new aluminum lugs complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing LT underground cable XLPE insulated and armoured and PVC sheathed 1100 volts grade, heavy duty with multistranded aluminum conductor of size 400 sqmm 3.5 core laid in trenches/ducts/along poles/through pipe under road etc with new aluminum lugs complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of new out door type LT feeder pillar box factory made CPRI approved ; openable from front & rear, double door with flush type hinges and flush cylindrical locks, dust and vermin proof, fabricated 3.15 mm thick CRCA sheet duly painted with two coats of powder coated of approved shade over a coat of zinc chrome primer and MC 75 chanel for base frame work complete with 4 Nos heat shrinkable insulated aluminum bus bars of capacity not less than 1.5 times of incoming MCCB/ACB including all MCCB connections with suitable rating aluminum busbar strip. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) complete all as specified and as directed and comprising of following accessories:- INCOMING (a) MCCB four pole 415 Volts ,50 HZ, 400Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 Nos. (b) Arc guard system-01 No shall be mounted on din rail. (c) Trip signal to main circuit breaker <1ms in event of arc. OUTGOING (a) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 200Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 02 Nos . (b) MCCB four pole 415 Volts ,50 HZ, 120 Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 02 Nos. (c) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (d) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, installation, testing and commissioning of new out door type LT feeder pillar box factory made CPRI approved ; openable from front & rear, double door with flush type hinges and flush cylindrical locks, dust and vermin proof, fabricated 3.15 mm thick CRCA sheet duly painted with two coats of powder coated of approved shade over a coat of zinc chrome primer and MC 75 chanel for base frame work complete with 4 Nos heat shrinkable insulated aluminum bus bars of capacity not less than 1.5 times of incoming MCCB/ACB including all MCCB connections with suitable rating aluminum busbar strip. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) complete all as specified and as directed and comprising of following accessories:- INCOMING (a) MCCB four pole 415 Volts ,50 HZ, 250Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 Nos. (b) Arc guard system-01 No shall be mounted on din rail. (c) Trip signal to main circuit breaker <1ms in event of arc. OUTGOING (a) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 63 Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 07 Nos. (b) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (c) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, installation, testing and commissioning of new out door type LT feeder pillar box factory made CPRI approved ; openable from front & rear, double door with flush type hinges and flush cylindrical locks, dust and vermin proof, fabricated 3.15 mm thick CRCA sheet duly painted with two coats of powder coated of approved shade over a coat of zinc chrome primer and MC 75 chanel for base frame work complete with 4 Nos heat shrinkable insulated aluminum bus bars of capacity not less than 1.5 times of incoming MCCB/ACB including all MCCB connections with suitable rating aluminum busbar strip. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) complete all as specified and as directed and comprising of following accessories:- INCOMING (a) MCCB four pole 415 Volts ,50 HZ, 250Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 Nos. (b) Arc guard system-01 No shall be mounted on din rail. (c) Trip signal to main circuit breaker <1ms in event of arc. OUTGOING (a) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 120Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 03 Nos. (b) MCCB four pole 415 Volts ,50 HZ, 100 Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 Nos. (c) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three). (d) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, installation, testing and commissioning of new out door type LT feeder pillar box factory made CPRI approved ; openable from front & rear, double door with flush type hinges and flush cylindrical locks, dust and vermin proof, fabricated 3.15 mm thick CRCA sheet duly painted with two coats of powder coated of approved shade over a coat of zinc chrome primer and MC 75 chanel for base frame work complete with 4 Nos heat shrinkable insulated aluminum bus bars of capacity not less than 1.5 times of incoming MCCB/ACB including all MCCB connections with suitable rating aluminum busbar strip. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) complete all as specified and as directed and comprising of following accessories:- INCOMING (a) MCCB four pole 415 Volts ,50 HZ, 320Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 Nos. (b) Arc guard system-01 No shall be mounted on din rail. (c) Trip signal to main circuit breaker <1ms in event of arc. OUTGOING (a) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 100Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 03 Nos. (b) MCCB four pole 415 Volts ,50 HZ, 160 Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 02 Nos. (c) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three). (d) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, installation, testing and commissioning of new out door type LT feeder pillar box factory made CPRI approved ; openable from front & rear, double door with flush type hinges and flush cylindrical locks, dust and vermin proof, fabricated 3.15 mm thick CRCA sheet duly painted with two coats of powder coated of approved shade over a coat of zinc chrome primer and MC 75 chanel for base frame work complete with 4 Nos heat shrinkable insulated aluminum bus bars of capacity not less than 1.5 times of incoming MCCB/ACB including all MCCB connections with suitable rating aluminum busbar strip. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) complete all as specified and as directed and comprising of following accessories:- INCOMING (a) MCCB four pole 415 Volts ,50 HZ, 400Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 Nos. (b) Arc guard system-01 No shall be mounted on din rail. (c) Trip signal to main circuit breaker <1ms in event of arc. OUTGOING (a) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 100Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 05 Nos . (b) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (c) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, installation, testing and commissioning of new out door type LT feeder pillar box factory made CPRI approved ; openable from front & rear, double door with flush type hinges and flush cylindrical locks, dust and vermin proof, fabricated 3.15 mm thick CRCA sheet duly painted with two coats of powder coated of approved shade over a coat of zinc chrome primer and MC 75 chanel for base frame work complete with 4 Nos heat shrinkable insulated aluminum bus bars of capacity not less than 1.5 times of incoming MCCB/ACB including all MCCB connections with suitable rating aluminum busbar strip. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) complete all as specified and as directed and comprising of following accessories:- INCOMING. (a) MCCB four pole 415 Volts ,50 HZ, 400 Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 Nos. (b) Arc guard system-01 No shall be mounted on din rail. (b) Trip signal to main circuit breakder <1ms in event of arc. OUTGOING. (a) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 120Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 05 Nos. (b) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three). (c) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, installation, testing and commissioning of new out door type LT feeder pillar box factory made CPRI approved ; openable from front & rear, double door with flush type hinges and flush cylindrical locks, dust and vermin proof, fabricated 3.15 mm thick CRCA sheet duly painted with two coats of powder coated of approved shade over a coat of zinc chrome primer and MC 75 chanel for base frame work complete with 4 Nos heat shrinkable insulated aluminum bus bars of capacity not less than 1.5 times of incoming MCCB/ACB including all MCCB connections with suitable rating aluminum busbar strip. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) complete all as specified and as directed and comprising of following accessories:- INCOMING (a) MCCB four pole 415 Volts ,50 HZ, 250 Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 Nos. (b) Arc guard system-01 No shall be mounted on din rail. (c) Trip signal to main circuit breaker <1ms in event of arc. OUTGOING (a) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 100Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 04 Nos . (b) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (c) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, installation, testing and commissioning of new out door type LT feeder pillar box factory made CPRI approved ; openable from front & rear, double door with flush type hinges and flush cylindrical locks, dust and vermin proof, fabricated 3.15 mm thick CRCA sheet duly painted with two coats of powder coated of approved shade over a coat of zinc chrome primer and MC 75 chanel for base frame work complete with 4 Nos heat shrinkable insulated aluminum bus bars of capacity not less than 1.5 times of incoming MCCB/ACB including all MCCB connections with suitable rating aluminum busbar strip. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) complete all as specified and as directed and comprising of following accessories:- INCOMING (a) MCCB four pole 415 Volts ,50 HZ, 400Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 Nos. (b) Arc guard system-01 No shall be mounted on din rail. (c) Trip signal to main circuit breaker <1ms in event of arc. OUTGOING (a) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 160Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 02 Nos. (b) MCCB four pole 415 Volts ,50 HZ, 100 Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 02 Nos. (c) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (d) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, installation, testing and commissioning of new out door type LT feeder pillar box factory made CPRI approved ; openable from front & rear, double door with flush type hinges and flush cylindrical locks, dust and vermin proof, fabricated 3.15 mm thick CRCA sheet duly painted with two coats of powder coated of approved shade over a coat of zinc chrome primer and MC 75 chanel for base frame work complete with 4 Nos heat shrinkable insulated aluminum bus bars of capacity not less than 1.5 times of incoming MCCB/ACB including all MCCB connections with suitable rating aluminum busbar strip. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) complete all as specified and as directed and comprising of following accessories:- INCOMING (a) MCCB four pole 415 Volts ,50 HZ, 250 Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 Nos. (b) Arc guard system-01 No shall be mounted on din rail. (c) Trip signal to main circuit breaker <1ms in event of arc. OUTGOING (a) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 120 Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 03 Nos . (b) MCCB four pole 415 Volts ,50 HZ, 100 Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 Nos . (c) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (d) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, installation, testing and commissioning of new out door type LT feeder pillar box factory made CPRI approved ; openable from front & rear, double door with flush type hinges and flush cylindrical locks, dust and vermin proof, fabricated 3.15 mm thick CRCA sheet duly painted with two coats of powder coated of approved shade over a coat of zinc chrome primer and MC 75 chanel for base frame work complete with 4 Nos heat shrinkable insulated aluminum bus bars of capacity not less than 1.5 times of incoming MCCB/ACB including all MCCB connections with suitable rating aluminum busbar strip. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) complete all as specified and as directed and comprising of following accessories:- INCOMING (a) MCCB four pole 415 Volts ,50 HZ, 250Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 Nos. (b) Arc guard system-01 No shall be mounted on din rail. (c) Trip signal to main circuit breaker <1ms in event of arc. OUTGOING (a) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 100Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 04 Nos. (b) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (c) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, installation, testing and commissioning of new out door type LT feeder pillar box factory made CPRI approved ; openable from front & rear, double door with flush type hinges and flush cylindrical locks, dust and vermin proof, fabricated 3.15 mm thick CRCA sheet duly painted with two coats of powder coated of approved shade over a coat of zinc chrome primer and MC 75 chanel for base frame work complete with 4 Nos heat shrinkable insulated aluminum bus bars of capacity not less than 1.5 times of incoming MCCB/ACB including all MCCB connections with suitable rating aluminum busbar strip. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) complete all as specified and as directed and comprising of following accessories:- INCOMING (a) MCCB four pole 415 Volts ,50 HZ, 200Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 Nos. (b) Arc guard system-01 No shall be mounted on din rail. (c) Trip signal to main circuit breaker <1ms in event of arc. OUTGOING (a) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 100Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 04 Nos. (b) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (c) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, installation, testing and commissioning of new out door type LT feeder pillar box factory made CPRI approved ; openable from front & rear, double door with flush type hinges and flush cylindrical locks, dust and vermin proof, fabricated 3.15 mm thick CRCA sheet duly painted with two coats of powder coated of approved shade over a coat of zinc chrome primer and MC 75 chanel for base frame work complete with 4 Nos heat shrinkable insulated aluminum bus bars of capacity not less than 1.5 times of incoming MCCB/ACB including all MCCB connections with suitable rating aluminum busbar strip. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) complete all as specified and as directed and comprising of following accessories:- INCOMING (a) MCCB four pole 415 Volts ,50 HZ, 400Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 Nos. (b) Arc guard system-01 No shall be mounted on din rail. (c) Trip signal to main circuit breaker <1ms in event of arc. OUTGOING (a) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 160Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 02 Nos. (b) MCCB four pole 415 Volts ,50 HZ, 100 Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 02 Nos. (c) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (d) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, install, commission and testing LT feeder piller box outdoor type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system including and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) alongwith incoming MCCB 4 pole, 415 Volts, 63 Amps, 25 KA - 01 Nos alongwith 1.5 times amps rated aluminum bus bar of incoming MCCB suitable for 6 nos outgoing 16 sqmm 4 core XLPE aluminum armoured cable complete all as specified and directed.
Supply, install, commission and testing LT feeder piller box outdoor type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system including and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) alongwith incoming MCCB 4 pole, 415 Volts, 100 Amps, 25 KA - 01 Nos alongwith 1.5 times amps rated aluminum bus bar of incoming MCCB suitable for 6 nos outgoing 16 sqmm 4 core XLPE aluminum armoured cable complete all as specified and directed.
Supply, install, commission and testing LT feeder piller box outdoor type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system including and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) alongwith incoming MCCB 4 pole, 415 Volts, 125 Amps, 25 KA - 01 Nos alongwith 1.5 times amps rated aluminum bus bar of incoming MCCB suitable for 6 nos outgoing 16 sqmm 4 core XLPE aluminum armoured cable complete all as specified and directed.
Supply, install, commission and testing LT feeder piller box outdoor type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system including and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) alongwith incoming MCCB 4 pole, 415 Volts, 160 Amps, 25 KA - 01 Nos alongwith 1.5 times amps rated aluminum bus bar of incoming MCCB suitable for 6 nos outgoing 16 sqmm 4 core XLPE aluminum armoured cable complete all as specified and directed.
Supply, install, commission and testing LT feeder piller box outdoor type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system including and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 50 cm long each below the base of panel made of angle iron support 50x50x6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) alongwith incoming MCCB 4 pole, 415 Volts, 200 Amps, 25 KA - 01 Nos alongwith 1.5 times amps rated aluminum bus bar of incoming MCCB suitable for 6 nos outgoing 16 sqmm 4 core XLPE aluminum armoured cable complete all as specified and directed.
Supply and fixing Galvanised steel tubing, light grade, with fittings and MS clamps, nuts, bolts etc of 40 mm dia bore for cable protection on pole/wall, road crossing/driange/footpath alongwith pcc work making the disturbed surface as per existing surface complete all as specified and directed.
Supply and fixing Galvanised steel tubing, light grade, with fittings and MS clamps, nuts, bolts etc of 80 mm dia bore for cable protection on pole/wall, road crossing/driange/footpath alongwith pcc work making the disturbed surface as per existing surface complete all as specified and directed.
M&L for cutting of Road/ hard standing not less than 30 cm in depth and 30 cm in width underneath the road for passing the cable/pipe and making good with PCC 1:2:4 type B-1 where road cutting done to make the road surface fair and level complete all as specified and directed by Engr-in Charge.
Earthing complete with galvanized iron or steel plate electrode 600mm x 600mm x 6.0 mm burried directly in ground vertially in a pit of depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth of not less than 1.50m below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to with and including GI/ Steel strip of size 32mmx6mm upto a length of 7.50 metre by means of bolts, nuts, check nuts & washers of galvanized iron /steel, earth strip protected by and including galvanized steel pipe light grade of bore 40 mm (internal dia) & connected to main control board / switch board or any other electrical equipment complete all as shown in electrical plate No : 3 MES SSR including necessary excavation & earth work, disposal of surplus soil not exceeding 50m, in any type of soil. (The rate also includes for cost of charcoal & salt in alternate layers of 15 cm thickness, 20 mm bore internal dia GI/steel pipe light grade) for watering, funnel, wire mesh, PCC chamber in cement concrete (1:3:6) type C-1, 40mm thick RCC (1:2:4) type B-0, reinforced with XPM of weight not less than 4.00 kg/Sqm and mild steel frame of angle 50mm x 50mm x 6mm and testing on competion all as specified and directed.
Supply and laying 50 mm outer dia, double walled, corrugated HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
Supply and fix non metallic junction box out of PVC sheet of thickness 3.00 mm of size not less than 240mm x 130 mm x 110 mm hinged with lockable arrangement with and including aluminum busbar TPN capacity 200 Amps with one Nos MCB 2.5 amps SP 10 ka 'C' curve with provn of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole or grounting in PCC with suitable size cmaps, net bolts etc complete all as specified and directed by Engr in Charge.
Supply, laying, jointing and testing multistranded copper cable PVC insulated unearthed 1100 volts grade of size 2.50 sqmm 3.00 core for connecting from junction box to light fitting and making connection and testing for functioning of light fitting complete all as specified and dircted by Engr in Charge.
Taking down old unsv LT cable of size 10 sqmm 2 core to 35 sqmm 4 core from LT Pole/bldgs complete all as specified and directed by Engineer-in-Charge.
M/S BALWINDER SINGH
JAY BEE Industries
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .