Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.8 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹71.5 L+₹12.7 L (21.6%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | Rejected-Technical | - | Rejected-Technical not as per tender terms and conditions (NTS) |
| Sl No | Description | Qty | Unit | Modality Infrastructure LLP L1 | M/s Jullundur Construction Co. L2 |
|---|---|---|---|---|---|
| 1.00Renovation of Training and Placement Office | |||||
| 1.01 | Schedule of Quantities (Civil Work) - Note: Aluminum work & glass work should have been double glazing and walls require installation. Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : • For fixed portion • Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (in KG) | 1,600 | Nos | 460 ₹7,36,000 Lowest | 520 ₹8,32,000 |
| 1.02 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (in KG) | 450 | Nos | 560 ₹2,52,000 | 540 ₹2,43,000 Lowest |
| 1.03 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): • With toughened glass panes of 8 mm thickness (weight not less than 20 kg/ sqm) (In Sq. m) | 550 | Nos | 1,560 ₹8,58,000 Lowest | 2,480 ₹13,64,000 |
| 1.04 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (each) | 15 | Nos | 2,500 ₹37,500 | 2,250 ₹33,750 Lowest |
| 1.05 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. • Single rubber stopper (each) | 15 | Nos | 200 ₹3,000 | 130 ₹1,950 Lowest |
| 1.06 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. (each) | 15 | Nos | 1,700 ₹25,500 Lowest | 2,100 ₹31,500 |
| 1.07 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete • 200x10 mm (each) | 15 | Nos | 300 ₹4,500 Lowest | 415 ₹6,225 |
| 1.08 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. • Upto 5mm depth and 5 mm width (In meter) | 150 | Nos | 180 ₹27,000 | 80 ₹12,000 Lowest |
| 1.09 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/ sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, Galvanised M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each with zinc coating of 120 gms/sqm(both side inclusive)) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete. • 75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming : to IS 2095: (part 1) : 1996 (Board with BIS certification marks) (In sq. m) | 65 | Nos | 1,520 ₹98,800 | 1,350 ₹87,750 Lowest |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
18 Apr 2022, 3:00 pmClosed
Director
Dr. B R Ambedkar NIT, Jalandhar
Renovation of Training and Placement Office
2022_NITJ_678894_1
NITJ/EO/Works/126/21
Open Tender
Civil Works - Buildings
Works
30 days
Dr. B R Ambedkar NIT
As per tender documents
2 documents required · 2 mandatory
₹500
Director
₹1.3 L
18 May 2022
28 Mar 2022
19 Apr 2022
28 Mar 2022
18 Apr 2022
28 Mar 2022
28 Mar 2022 - 11 Apr 2022
Amount
Renovation of Training and Placement Office
Schedule of Quantities (Civil Work) - Note: Aluminum work & glass work should have been double glazing and walls require installation. Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : • For fixed portion • Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (in KG)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (in KG)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): • With toughened glass panes of 8 mm thickness (weight not less than 20 kg/ sqm) (In Sq. m)
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (each)
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. • Single rubber stopper (each)
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. (each)
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete • 200x10 mm (each)
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. • Upto 5mm depth and 5 mm width (In meter)
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/ sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, Galvanised M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each with zinc coating of 120 gms/sqm(both side inclusive)) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete. • 75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming : to IS 2095: (part 1) : 1996 (Board with BIS certification marks) (In sq. m)
Providing and fixing crystal glass film frosted (sparkle effect) with approved art work, cut using digital plotter, self- adhesive , double- free installation to be done on glass. (In sq. m)
Providing and fixing glass wool wall insulation of density 48kg/cum and thickness as per requirement on site. (In sq. m)
Providing and fixing drop down door seal. (each)
Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. • For door/ window/ clerestory window (In sq. m)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : • Cement mortar 1:4 (1 cement : 4 coarse sand) (In cum)
12 mm cement plaster of mix : • 1:4 (1 cement : 4 fine sand) (In sq. m)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (In sq. m)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : • New work (two or more coats) over and including water thinnable priming coat with cement primer (In sq. m)
Schedule of Quantities (Electrical Work) (Wiring) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. • Group C (In Points)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required • 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (In metre)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required • 2 X 4 sq. mm + 1 X 4 sq. mm earth wire (In metre)
Supplying and laying of following size of PVC insulated and PVC sheathed/XLPE copper conductor cable of 1.1 kv grade etc. as required for VRF AC supply. (In metre)
(Wall Points) Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. • 3 Module (each)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. • 4 Module (each)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. • 8 Module (each)
Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc. as required. • 6 A switch (each)
Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc. as required. • 6 A socket outlet (each)
Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc. as required. • 16 A switch (each)
Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc. as required. • 6 pin 16 A socket outlet (each)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (each)
(Internet) Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed steel/PVC conduit as required. • I run of cable (in Metre)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. • RJ 45 socket (each)
(DB / MCB) Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) • 8 way (4 + 24), Double door (each)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required • Single pole (each)
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. • 100 A (each)
Supplying, Installation, testing commissioning of 15 watt circular recessed mounted LED Luminaries cutting the false ceiling as per requirement of new fitting and filling the gap in false ceiling with Gypson board painting etc as required. The fitting shall be made of white powder coated CRCA sheet metal housing with replaceable driver with Short circuit and Overvoltage protection having Luminaries efficacy 2 color 120 temperature (CCT) of 5500K-6500K. The luminary should have PF 2 95% and THD< 10% suitable for operation on 120 to 270V single phase A.C. supply. The driver used must have a constant current driver with Im/watt and Co-related efficiency > 90%.High quality diffuser fixed with main housing to give uniform and glare free light alongwith L-70 life minimum 50000 burning hours etc. as required. (In nos.)
Supply,installation,testing and commissioning of Variable refrigerant flow ( VRF/VRF)modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor complete with indoor and outdoor units with individual controller and with fittings etc., as per quantity given below i/c full charging of R-410A refrigerant gas complete with duly powder coated and Outdoor unit with MS stand and all supports required a. Outdoor Unit : 60 HP (20 HP X 3 ) (In nos.)
Supply,installation,testing and commissioning of Variable refrigerant flow ( VRF/VRF)modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor complete with indoor and outdoor units with individual controller and with fittings etc., as per quantity given below i/c full charging of R-410A refrigerant gas complete with duly powder coated and Outdoor unit with MS stand and all supports required b. Indoor units (Nominal capacity) : 4 Way Cassette Type Indoor Unit with cordless remote - 1 TR (In nos.)
Supply,installation,testing and commissioning of Variable refrigerant flow ( VRF/VRF)modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor complete with indoor and outdoor units with individual controller and with fittings etc., as per quantity given below i/c full charging of R-410A refrigerant gas complete with duly powder coated and Outdoor unit with MS stand and all supports required b. Indoor units (Nominal capacity) : 4 Way Cassette Type Indoor Unit with cordless remote - 1.5 TR (In nos.)
Supply,installation,testing and commissioning of Variable refrigerant flow ( VRF/VRF)modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor complete with indoor and outdoor units with individual controller and with fittings etc., as per quantity given below i/c full charging of R-410A refrigerant gas complete with duly powder coated and Outdoor unit with MS stand and all supports required b. Indoor units (Nominal capacity) : 4 Way Cassette Type Indoor Unit with cordless remote - 2 TR (In nos.)
Supply,installation,testing and commissioning of Variable refrigerant flow ( VRF/VRF)modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor complete with indoor and outdoor units with individual controller and with fittings etc., as per quantity given below i/c full charging of R-410A refrigerant gas complete with duly powder coated and Outdoor unit with MS stand and all supports required b. Indoor units (Nominal capacity) : 4 Way Cassette Type Indoor Unit with cordless remote - 4 TR (In nos.)
Supply of Refrigerant 'Y'Joint Required for distribution of refrigerant in copper piping stc complete as per specifications (In nos.)
Supplying & Installation of interconnecting following size of refrigerant copper pipe work with fitting duly inculated with 19/13 mm thick closed cell elastometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported with M.S. hanger. i) 6.3 mm dia with 13mm thick nitrile rubber insulation (In Rmt.)
Supplying & Installation of interconnecting following size of refrigerant copper pipe work with fitting duly inculated with 19/13 mm thick closed cell elastometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported with M.S. hanger. ii) 9.53 mm dia with 13mm thick nitrile rubber insulation (In Rmt.)
Supplying & Installation of interconnecting following size of refrigerant copper pipe work with fitting duly inculated with 19/13 mm thick closed cell elastometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported with M.S. hanger. iii) 12.7 mm dia with 13mm thick nitrile rubber insulation (In Rmt.)
Supplying & Installation of interconnecting following size of refrigerant copper pipe work with fitting duly inculated with 19/13 mm thick closed cell elastometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported with M.S. hanger. iv) 15.86 mm dia with 13mm thick nitrile rubber insulation (In Rmt.)
Supplying & Installation of interconnecting following size of refrigerant copper pipe work with fitting duly inculated with 19/13 mm thick closed cell elastometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported with M.S. hanger. v) 19.05 mm dia with 13mm thick nitrile rubber insulation (In Rmt.)
Supplying & Installation of interconnecting following size of refrigerant copper pipe work with fitting duly inculated with 19/13 mm thick closed cell elastometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported with M.S. hanger. vi) 22 mm dia with 19mm thick nitrile rubber insulation (In Rmt.)
Supplying & Installation of interconnecting following size of refrigerant copper pipe work with fitting duly inculated with 19/13 mm thick closed cell elastometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported with M.S. hanger. vii) 28.58 mm dia with 19mm thick nitrile rubber insulation (In Rmt.)
Supplying & Installation of interconnecting following size of refrigerant copper pipe work with fitting duly inculated with 19/13 mm thick closed cell elastometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported with M.S. hanger. viii) 34.59 mm dia with 19mm thick nitrile rubber insulation (In Rmt.)
Supplying & Installation of interconnecting following size of refrigerant copper pipe work with fitting duly inculated with 19/13 mm thick closed cell elastometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported with M.S. hanger. ix) 41.2 mm dia with 19mm thick nitrile rubber insulation (In Rmt.)
(Drain Piping) Rigid PVC Piping complete with fittings,supports as per specifications and duly insulated with 6 MM thick closed cell nitrile rubber insulation • 25 MM (In Rmt)
(Control & Transmission Wiring) Providing & fixing control cum transmission wiring of 2 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit. (In Rm)
M/s Jullundur Construction Co.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .