Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-Finance | L1 | Accepted-Finance L1 Bidder (Resultant Single Tender) | |
| 2 | Rejected-Technical | - | Rejected-Technical MSME Registration Certificate with different division and group. Bid security declaration form on a stamp paper submitted by firm. | |
| 3 | Rejected-Technical | - | Rejected-Technical MSME Registration certificate submitted. Bid security declaration from not submitted on a stamp paper. |
Tender Value
Refer Docs
Closing Date
12 Jul 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SK DUBEY, SC F
CCE (RnD) Estates South Chandrayangutta Hyderabad - 05
Provision of Civil and Allied works at PCDA (RnD) Office, Hyderabad
2021_DRDO_631277_1
CCEESTENQCIVPCDAHYD/10/21-22
Limited
Civil Works
Item Rate
90 days
Kanchanbagh
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
27 Jul 2021
26 May 2021
13 Jul 2021
26 May 2021
12 Jul 2021
26 May 2021
90 days
Amount
Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
Random Rubble Masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
a) Cement mortar 1:6 (1 cement : 6 coarse sand).
15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand)
Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge.
Supply of approved Earth obtained from outside MOD land filling in layers not exceeding 20cms thick at all heights and depths in foundations, pits, trenches, sewer lines around structures and foundation under floors other places including dressing and levelling watering, consolidation to achieve minimium of 95% proctor density etc., complete as per drawing specifications, (Payment shall be made for the quantity after deducting the void).
Providing and fixing stainless steel (Grade 304) Railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Supply of Grass and planting by dibbling the area including watering & Maintenance of Lawn for 30 days or more till grass forms a thick lawn cushion free from weeds. With Doob Grass (15 cm x 15 cm apart) including one year maintenance after completion of work
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
In cement mortar
Excavation Work by Mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
Hard Rock (Blasting prohibited)
Filling Available Excavated Earth (Excluding Rock) in trenches,Plinth sides of foundatios etc,in layers not exceeding 20cm in depth consolidating each diposited layer by ramming and watering,lead upto 50meter and lead upto 1.5meter
Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and includingpriming coat of exterior primer applied @ 2.20kg/10 sqm
Repairing of existing fountain all including making good electrical repairs, motor repair and replacing the damaged pipe line network, nozzles etc., and making the fountain functional all complete.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand).
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Providing and placing in position 2 Nos 8mm dia. M.S. Bars at every third course of half brick masonry. Cement mortar 1:4 (1 cement : 4 coarse sand).
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 40 mm thick
Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: (Profile C) Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing 35mm thick Flush Door Shutters, with commercial ply with teak veneering on the both sides or approved make, core of block board construction with frame of first class hard wood including providing and fixing internal lipping with second class teak wood battens 25mm minimum depth on all edges of shutter etc.,complete all as per drawings and as directed.
Providing and fixing the following hardware fittings of approved make. ISI marked aluminium powder coated to required colour or shade with necessary screws etc., complete:-
125mm long handles
Tower Bolt of size 150X10mm
Aluminium hanging floor Door Stopper. (Twin rubber stopper)
Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
Providing and applying two coats of synthetic enamel paint of approved brand and shade over a coat of primer including preparation of surface and applying approved brand putty on following surfaces at all levels and locations etc., complete.
Wooden Surfaces
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
Supplying and fixing in position best quality and approved make heavy quality screws down gun metal gate valves with hand wheel of the following sizes fixed to service lines including testing, making good the leakages, if any etc.,
Supplying, laying, jointing, testing and commissioning; UPVC(SWR) pipe (Type-B) as per IS : 13592/1992 including specials of best quality and approved make fixed to wall/floor including chasing, cutting, making the hole in walls/floors, cutting the pipes to the required size of length jointing the pipes and specials with suitable resin and testing etc.,complete all as specified and directed. (Specials at junctions must have access doors wherever required.)
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Coupler 75MM
Coupler 110MM
Coupler 150MM
Bend 87.5° 75MM
Bend 87.5° 110MM
Bend 87.5° 150MM
Shoe (Plain) 75 mm Shoe
Shoe (Plain) 110 mm Shoe
Shoe (Plain) 150 mm Shoe
Providing and fixing PVC rain water down take pipe of 6kg/cm2 pressure or grade etc.,including necessary fittings like clamps, bends, shoes and adhesives etc., complete all as directed.
110 mm dia
Supply and fixing of 50MM Thick AEROCON wall partion including all doors, accessories all complete as per standard and manufacturer's specifications and as directed by Engineer-in-Charge
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls/partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
With 16 mm thick beveled tegular mineral fibre Anti-microbial false ceiling tile confirming to ISO 5 (class 100) specifications
Removal of glass panel and supply of perforated panel with mosquito mesh
Supply and fixing of CNC panelling including all accessories etc., for aquarium. The panelling should be detachable for maintaince purpose of acquarium
White washing with lime to give an even shade: (2 coats)
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .