| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAccepted-AOC | L1 | Accepted-AOC ok |
Tender Value
₹1.4 L
EMD Value
₹2,700
Closing Date
24 Feb 2020, 5:00 pmClosed
JAGVIR SINGH KAJLA
EXECUTIVE ENGINEER PROV DIV NO 4 PWD B AND R PGIMS ROHTAK
Reinvited for Construction of transformer Meter Room in CHC Chiri under Pt BD Sharma in University of Health Sciences Rohtak
2020_HRY_118661_1
PWD/P4/375
Open Tender
Civil Works
Works
90 days
ROHTAK
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
EXECUTIVE ENGINEER PROV DIV NO 4 PWD B AND R PGIMS
₹2,700
Yes
21 Jul 2020
15 Feb 2020
24 Feb 2020
15 Feb 2020
24 Feb 2020
15 Feb 2020
Amount
Earth work in excavation in foundations, trenches, etc. in all kinds of soils, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 meters. (HSR 6.6)
Cement concrete 1:8:16 with brick ballast 40 mm Nominal size in foundation and plinth.(HSR 10.26)
Cement concrete 1:1-1/2:3 with stone aggregate 20 mm Nominal size for reinforced concrete work for walls exceeding 20 cm thinkness (straight and curved) beams, girders,stairs, columns,(square olr rectangular ) battens and lintels etc. excluding steel reinforcement but including centring and shuttering , laid in position ,complete in all respects(HSR.10.86+10.95,a)
Cement concrete 1:1-1/2:3 with stone aggregate 20mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal ,excluding steel reinforcement, but including centring and shuttering ,laid in position , complete in all respects.(HSR.10.82+10.95,a)
Damp proof course 40 mm thick of cement concrete 1:2:4 using stone aggregate with two coats of bitumen 20/30 penetration at 1.65 Kg. per sqm laid hot and sanded.(HSR 10.114)
First class brick work laid in cement sand mortar 1:6 in foundation and plinth(HSR.11.2)
First class brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level (HSR.11.7)
11.43 cm thick brick wall laid in cement sand mortar 1:4 in superstructure(HSR.11.48 a)
Terracing consisting of tiles 22.86 cm X 11.43 cm X 3.81 cm laid over 87.50 mm mud filling on a layer of 25mm mud plaster and another layer of mud mortar for laying the tiles , including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc.(HSR.13.13)
Top Khurra 0.6mx 0.6m for rains water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16 ( HSR 13.50).
Cement concrete 1:2:4 gola 10cm X 10 cm quadrant along junction of roof with parapet wall finished smooth ,where specially specified.(HSR.13.64)
Providing and fixing PVC rain water pipe 6kg pressure of ISI mark in cement mortar during masonry work.(HSR 13.89)
(a) 100 mm dia PVC pipe 6 kg . Presure
Providing & fixing PVC bend ISI mark(HSR 13.90)
(a) 100 mm dia PVC bend
Base course of floors consisting of 100 mm thick cement concrete 1:8:16 and 100 mm sand or stone filling(HSR.14.1)
Precast chequered tiles of 20mm thickness in ordinary grey cement without chipps laid on 20mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps and landings. (HSR 14.45)
Laying and fixing vitrified/ceramic/glazed tiles of any size of approved make in skirting/dado, pillars, wall facing, laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles. (Tiles shall be supplied by the Department). (HSR 14.94)
Laying and fixing granite stone in all shades, 15mm to 18mm thick in flooring, laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of granite stone (excluding the cost of granite stone) (HSR 14.96)
12 mm thick cement plaster 1:6 on walls (HSR 15.7)
15 mm thick cement plaster 1:6 on the rough side of single or half brick wall (HSR 15.12)
10 mm thick cement plaster 1:4 under side of ceiling (HSR 15.52)
Distempering with washable oil bound distemper (of approved manufacture) two coats excluding priming coat on new work. (HSR 16.57) L.R
Providing two coats of exterior acrylic emulsion paint. ( HSR 16.79) L.R
(b) 1st quality
Providing and applying two coats white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material labour charges scaffolding sundries etc. complete (J.K/Birla make)(HSR 16.81) L.R
Fe-500 EQR TMT steel bars for R.C.C works, where Not included in the complete rate of R.C.C. including bending, binding and placing in position complete. (HSR 18.22)
Pressed steel sheet frames (chowkats) consisting of 2mm thick steel sheet of the specified section, including iron lugs (hold fasts) iron hinges, conforming to P.W.D. specifications, including bolts for fixing stops, locknotch, provision for receiving tower bolts, and finished with one coat of ready mixed paint red lead Non-setting primer,of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame, and cement concrete 1:3:6 for lugs complete :-(HSR 18.34)
(b) Door and window frame of size 76 mm x 38 mm with 35 mm wide single rebate
P.H WORK
Labour for laying jointing, fixing and testing G.I./P.V.C./W.I. pipe lines and specials tees bends, sockets elbows etc., inside building and testing etc. complete including cutting threading. (HSR 28.18) (a) Excluding cost of specials
(i) 15 mm internal diameter of pipeline
(ii) 20 mm internal diameter of pipeline
Extra for fixing and jointing union couplings in G.I. and W.I. pipelines (HSR 28.21)
(a) 15 mm internal diameter
(b) 20 mm internal diameter
Drilling and tapping cast iron pipe lines of all diameters and screwing in ferrule and connections (HSR 28.22) (c) 20 mm internal diameter
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels on G.I. pipelinges laid in the ground or inside buildings including cartage from divisionnal stores or nearest railway station to site of works (HSR 28.29) (b) 20 mm internal diameter
Extra over item Nos. 30.3 to 30.6 for Providing and fixing best indian make plastic hygenic seat with lid complete instead of hollow black or white plastic seat and lid.(HSR 30.13) (i) White plastic seat (Solid)
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE (ORDINARY) LAVATORY SUITES consisting of :-Lavatory in VITREOUS CHINAWARE size as give below ( to the approval of the Engineer-in-charge) including china plug for tap hole where necessary ; R.S. or C.I. BRACKETS for building into wall including painting;32mmC.P.BRASS WASTE WITH C.P. brass chain and rubber plug;15mm C.P.BRASS SCREW DOWN PILLAR TAP WITH jamnuts or couplings best design (as approved by the Engineer-in-charge) ALL FITTINGS BEST INDIAN MAKE and to the approval of the Engineer-in-charge. All brass work chromium plated and complete in all respects including cutting and making good the walls floors and painting of fittings etc.(HSR.30.41) (i) White (iv) Size 550mmx400mm with one no. tap
Providing & fixing in position best indian make towel rails fixed in with rawlslugs embeded in walls with C.P brass screws complete in all respect including cutting and making good the walls etc.(HSR.30.68) (b) 20mm dia C.P brass adjustable (ii) 600mm long
Providing and fixing in position best indian make bevelled edge.5.5 mm thick mirror mounted on asbestos sheet ground in position by means of 4 nos. chormium plated brass screws and washers over rubber washers and and rawl plug embeded in the wall or cohormium plated brass clamps with C.P brass screws (as required by the Engineer-in-charge) complete including cutting and making good the walls etc.(HSR.30.71) (a) Indian Make (i) 600mm x 450mm
Providing and fixing in position super quality 65mm dia opening C.P. barss dome type hinged grating weighting about 750gms. Fixed in cement mortar 1:2 complete in all respects (as required by the Engineer-in-charge)(HSR 30.74)
Providing & fixing in position 15mm i/d C.P. brass bib cocks of best quality (as required by the Engineer-in-chargre). (HSR 30.75)
(a) Bib cock long body
(b) Bib cock sparrow with permix and flange.
Providing and fixing in position C.P. brass stop cocks (as approved by the Engineer-in-charge) (HSR 30.76) (a) 15 MM stop cock (ii) Concealed stop cock with flange
Providing and fixing in posotion best Indian make flexible tube connection.(HSR 30.82) (b) C.P. Brass (i) 15mm x 300mm
Providing and fixing in position H.C.I. soil waste vent or antisyphonage pipes to I.S.I. specification of E.I.c. manufacture or of any other reputed firm including cutting and wastage etc and cutting holes in walls roofs or floor etc and making good but ecluding cost of lead jointing (HSR 30.84)
(a) 100 mm internal diameter
(b) 75 mm internal diameter
Providing lead caulked joints to H.C.I. pipes and specials conforming to I.S.I. specification of E.I.C. manuacture or any other reputed firm including cost of lead yarn fuel and tools etc. (HSR 30.87)
(a) 100 mm internal diameter (1.13 kg.)
(b) 75 mm internal diameter (0.91 kg.)
Providing and fixing HCI floor tarps ISI marked of the self cleaning design with C.P brass hinged grating with frame with or without vent arm and including cement concrete1:2:4 under and around the floor trap where required upto floor level complete in all respects includig cutting and making good the walls and floor, etc.,minimum depth of water shoould be 150 mm with minimum scal of 50mm (HSR 30.89) (b) whith 75 mm i/d outlet
Providing and fixing in position HCI specials for soil waste vent or anti syphonage pipes to ISI marked including cutting holes in walls roofs or floors etc and making good but excluding cost of lead jointing (HSR 30.91)
(a) For 100mm I/D pipes
(xiii) Bend with door
(xxii) Collars
(b) For 75mm I/D pipes
(iv) Single junction with door 75mmx75mmx75mm
(xiii) Bend with door
(xviii) Collars
Providing and Fixing in position automatic brass ball valves in tanks (HSR 30.110) (a) With Copper Ball (i) 15mm internal diameter
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with HCI grating 150mmx150mm cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mmx300mm and outside size 330mmx330mm and chamber including cost of all brick work in cement mortar 1:5 cement concrete 1:8:16 in foundations, and cement concrete 1:2:4 in coping around C.I cover and frame etc. with three coats of black bitumastic superior paint of approved manufacture on all C.I. work as per standard design, minimum depth of water should be 150mm with a minimum seal 50mm.(HSR 30.114) (c) 150mm internal diameter S.W. gully trap
Providing and fixing in position best Indian make a range of three urinals flat back or angular lipped in viterous china ware with one no.10 letres capacity best Indian make C.I automatic flushing cistern with fittings and flush pipe etc. complete as fully decribed item No.30.19 above.(HSR 30.21)
465 mm high
(i) White
N.S ITEM P.H WORK
Supply G.I. pipes including cost of G.I. specials i.e. tee, elbow, sockets, bend etc. complete (Jindal B class) (N.S)
15mm dia
20mm dia
E.I WORK
Supply and erection of under ground cable, loose in existing pipe or trenches complete with necessary connections:- (HSR 31.26) (iv) 10 Sq. mm 2 Core Cable .(Armoured)
Wiring in existing Conduit pipe (Recessed) for Electrical points. (HSR 31.38)
Wiring only in 1.5 sqmm PVC insulated copper conductor cable in existing conduit pipe and MS boxes covered with 5mm thick backlite sheet including cost of switch, wall socket, ceiling rose etc.
(ii) Light Point
(b) Medium Point
(c) Long Point
(viii) 3 pin15 amp. plug point with 4 sq mm PVC insulated Copper conductor cable- including earthing the 3rd. pin etc.
(c) Long Point
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe (HSR 31.40)
(i) Cable size 1.5 sqmm (3/0.81mm)
(iii) Cable size 4 sqmm (7/0.85mm)
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including coast of PVC bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. (HSR 31.44) (b) 25 mm dia.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .