Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹13.1 L+₹3.4 L (35.2%)Rejected-Finance 411 STREET NO 4 PANCHVATI NAGAR BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹14.8 L+₹5.1 L (52.2%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹15.4 L+₹5.7 L (58.8%)Rejected-Finance HOUSE NO 3363 SECTOR 27 D CHANDIGARH | NA | NA | 160001 | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹15.8 L+₹6.1 L (62.5%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
8 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Chandigarh
GE Chandigarh N AREA PIN-160003
CERTAIN MISC PERIODICAL INCL REPAIR/REPLACEMENT AT E/M INSTALLATIONS AT K AREA UNDER GE CHANDIGARH
2021_MES_494366_1
GE/CHD-61/2021-22
Open Tender
Civil Works
Item Rate
270 days
Chandigarh
Class E category a(i) and b(i) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹40,000
Yes
25 Feb 2022
13 Dec 2021
10 Jan 2022
13 Dec 2021
8 Jan 2022
27 Dec 2021
14 Dec 2021 - 23 Dec 2021
60 days
Amount
Dismantling of Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings, complete all as specified
S&F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Dismantling fencing wire mesh/Chain Link Fencing any type
Excavating in post holes (or similar holes) in Soft & Loose Soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50m and making good surface
M&L cement concrete 1:2:4 type B-1 (using 40 mm grades stone agregate) as in foundations, filling and mass concrete complete as specified and directed
S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming Fe 410-W(Gde-E-250) quality A complete as specified and directed
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161- 1979 grade St.-240 complete as specified and directed
M&L for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 cm and not exc 10 cm long and 12 mm dia bolts
S&F chain link fencing of size 75 mm x 75 mm (3.10 mm nominal dia of wire) including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete as specified and directed
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, welding, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete as specified and directed
M&L Loose filling with aggregates of gauge 40 to 80 mm complete as specified and directed
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specially provided for complete all as specified and directed
M&L 75mm thick Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate) as in sub base under flooring all as specified and directed.
M&L 80 mm thickness M-40 Grade Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006, jointed and pointed with grey cement and no pigment including 50 mm thick sand cushioning and PCC lock at edges, complete all as specified and directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with Grey cement and no pigment over and including 15mm thick screed bed of CM 1:6 complete as specified and directed
M&L Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified.
Material & labour for brick work with sub class 'B' bricks, old size, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar (1:6) complete incl demolition all as specified and directed.
Sand filling under floors or in foundations including watering and consolidation complete as specified and directed
Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete as specified and directed
M&L 100 mm thick Plain cement concrete 1:2:4 type B-2 ( using 40 mm graded crushed stone aggregate) as in flooring finished even and smooth without using extra cement complete all as specified and directed
M&L Rendering 15mm thick on fair faces of brick work or concrete surface, in cement mortar 1:4 finished the surface even and smooth without using extra cement complete all as specified and directed
M&L for preparation of newly plastered surface of walls and applying two coats of cement base paint over a coat of chalk whitening primer complete all as specified.
M&L for preparing surfaces plastered or unplastered (Old surfaces) and applying two coats of white wash on wall complete all as specified.
M&L for preparing surfaces plastered or unplastered (Old surfaces) and applying two coats of white wash on ceiling complete all as specified.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M&L for preparation of old painted surfaces of steel over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified.
S&F Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, complete all as specified.
S& F for as in repair PVC insulated, unsheathed copper conductor cable 16 Sq mm, 4 core, flat in shape suitable for submersible pump motor complete all as specified and as directed by Engineer-in-Charge. Make : Palaza/Havells/Polycab
Disconnecting and removing U/S UG Cable and Supply, Laying and testing underground XLPE PVC insulated armoured heavy duty electric cable with aluminium multi-stranded conductor 1100 volts grade, 3.5Core, 25Sqmm complete all as specified and directed
All as per item No 31 above but size 3.5 core 35 Sqmm.
M&L for Outdoor type end jointing kit, heat shrinakable for 11KV grade UG cable with 3.5core Aliminium conductor of size 300 to 500 Sqmm 3.5 Core complete along with jointing material all as specified and as directed. Make: M-Seal/ Denson /Birla-3M
S&F Aluminium Lugs for cable of size 50 to 95 Sqmm
S&F Aluminium Lugs for cable of size 300 to 500 Sqmm
Supply and laying GI tubing, 50 mm dia, " light grade" ISI marked, galvanised laid in trenches / under road or floor / fixed alongwith pole / wall with suitable size MS clamps complete including taking out existing rusted GI tubing complete all as specified and as directed.
All as per item No. 36 above but 80mm dia, " light grade" ISI marked.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out . Note : Excavation shall be caried out manually. Exc with JCB will is not permitted.
Returning, filling in including spreading levelling, watering, and well ramming in layers not exc. 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated materials not exc 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
M & L for sand filling using approved clean dry sand for cushioning of under ground cables incl spreading levelling and well ramming in layers not exc 25 cm complete all as specified and directed.
Supply and laying of class 'B' bricks for under ground cable protection as directed by Engineer- in - charge
Supply and fix in repair of moulded case circuit breaker 4 pole, 415V 50Hz, 315 Amps with breaking capacity 35 KA with adjustable thermal and magnetic relay incl replacement of lugs complete all as specified and directed by Engr-in-Charge.
All as per item No 43 above but capacity 250Amp, 35KA
All as per item No 43 above but capacity 200Amp, 35KA
Repair/shifting of LT panel making electric connections incl wiring by conductor multi stranded PVC insulated welding of doors, fixing hinges, thimble incl refixing of MCCBs and brazing with bus bar etc complete all as specified and directed by Engr-in-Charge.
S&F energy saving LED street light 45 watt luminaire with high power LEDs with lens of beam angle of 120 degree,luminaire made of pressure die cast aluminium body with built in heat sinks, painted with polyurethan/powder coated paint, enclosed with toughened glass including separate compartment for cable and incl sealed/compact driver for easy access during maintenance,suitable for operating on voltage 120 - 270 volt, AC, 50 HZ,with surge protection of 5 KV ,out put luminous efficiency not less then100 Lumen/Watt, CRI more then 80, conforming to IP 66, class 1 complete all as per Manufacturer's specifications including taking down old unserviceable fittings of any size/ wattage complete all as directed by Engr-in-Charge.
S&F street light bracket made out of 40mm dia, 1.50 mtr long GI tubing, "medium grade" ISI marked, bent to required shape and angle as per site requirement with and including MS clamps size 30 x 6mm, with nuts, bolts, washers etc for fixing street light fittings and bracket, duly painted with two coats of aluminium paint over a coat of red oxide primer including taking out existing unserviceable rusted GI bracket complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate, electrode 60cm x 60cm x 6.0mm thick, buried directly in ground (earth pit not less than 4 mtr deep below normal ground level) with top edge of the plate not less than 3.25 mtr below normal ground level, connected to using galvanised iron strip 25X4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, connected to earthing test point, earth plate electrode surrounded by mixer of common salt and charcoal dust, including 20mm dia GI watering pipe ‘medium grade’, funnel with wire mesh, GI protetion pipe of size 40 mm dia up to test point or upto 7.5 mtr length, earthing chamber with cement concrete (1:2:4) type B-1, RCC chamber cover 80mm thick (1: 1 ½ : 3) type B1, excavation & earth work all as shown in electrical plate No 5 of SSR (Part-I) and testing on completion, complete all as specified and directed.
Taking down carefully aluminum/copper point wiring (light, fan, socket or power) complete along with fittings such as switches, ceiling roses, pendants, regulators sockets etc, and removing from site and making good disturbed surfaces of walls, floors etc all as directed by Engineer in Charge.
Taking down existing unserviceable sub main wiring with upto 4/6Sqmm aluminum/Copper cable all as directed by Engineer in Charge.
Point wiring for one light point controlled by one way 5 Amp switch with 1.5 Sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 Sqmm PVC insulated unsheathed copper conductor single core multi strand flexible and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green colour as earth lead in and including concealed non metallic rigid PVC conduit medium grade with all fittings (ISI marked) controlled by one switch including CI/MS sunk box of required size, & as directed by Engr in Charge & 3mm thick plastic laminated sheet, iuncluding cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified.
All as per item ser No 52 above but point wiring for one ceiling/exhaust fan point
All as per item No 52 above but one 3 pin 5 Amps switch socket out let point on independent board
All as per item No 52 above but one 3 pin 5 Amps switch socket out let point on same board
All as per item No 52 above but wiring with 2.5 Sqmm nominal area cable for 15 Amp socket outlet three pin Independent point with 2.5 Sqmm copper conductor for earthing (green colour).
M&L for Sub main wiring/power wiring complete with two runs of 4.0 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surface wall/floors/concealed etc., with one run of PVC insulated, 4.0Sqmm FRLS copper conductor for earth continuity all as specified and as directed. NOTE :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
Disconnection and removing the u/s 3X1.5 Sqmm PVC insulated unsheathed cable from the existing conduit and M&L for 3X1.5 Sqmm PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor drawn in the existing metal/ PVC conduit & Casing capping including connecting of the ends into the switch / socket/ DB complete. Make of PVC cables : Finolex/Polycab,Havells, Make of PVC Conduit : Mecury/Sudhaker/Avon Plast Note : Three runs of cable measured as one unit
Supply and fixing switch piano flush type single pole one way 5 Amps, 230 volts.
Supply and Fixing switch socket flush type universal 3 pin, 5 Amps 230 volts.
Supply and fixing switch piano flush type single pole one way 15 Amps, 230 volts.
Supply and Fixing switch socket flush type universal 3 pin 15 Amps 230 volts.
Supply and Fixing Ceiling rose 3 terminal 5 Amps 230 volts PVC/Polycarbonate, insulated body.
Supply and Fixing step type electronic fan regulator of capacity 100 watts 230 volts for ceiling / exhaust fan flush type.
Disconnection and removing the u/s light fitting and S&F LED Batten box type made of CRCA sheet including 1X20 watt retro LED tube rods and pre-wired with high efficiency electronic driver and connecting with three core PVC copper flexible cable of size 23/.0076 from ceiling rose to connector block complete all as specified.
Disconnection and removing the u/s DB and S&F MCB DB, SPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed.
S&F MCB SP 6-32 Amps 230 volts 10 KA ISI marked
All as per Item No 67 here in above but of capacity MCB SPN 40 Amps
Repair and servicing of Trolley mounted 4 Wheel extendable ladder including winch operating system assembly & replacement of following parts as per existing size and shape:- (a) Steel wire rope (As per sample) -30RM. (b) Ruberised wheel heavy duty (As per sample)- 04Nos. (c) Wheel bearing 04 Nos. Note:- Repair should include cost of oiling, greasing, topping up of oil in winch/gear box including welding of broken steel members, denting, penting of the lader complete all as directed by the Engr-in-Charge.
Taking out carefully with out damaging electrical equipment inside sub stn building, mild steel sheet gate shutter - 02 nos, reparing of the same by providing/welding suiable size and nos of hinges or other fixing arrangment such bearing so that the hinges or the bearing can hold the weight of the gate in still position as well as in moving position incl making necessary locking arangement. Painting of the gate or LT panels with two coats of synthetic enamel paint over a coat of red oxide as primer.
Rubber matting of size 2mx1mx25mm thick electrical 1.1 KV grade, chequered top in front of LT panel, complete all as specified and directed.
Taking down existing any type of sign board and M&L for any informatory sign board of size 100mmx600mm made out of 2mm thick stainless steel sheet fixed on stainless steel sheet frame of ractangular shape 45mmx25mm fixed on stainless steel pipe 50mm dia 2.25mtr long vertical member -02 nos, including letter writing (100 to 150 words), logo/drawing/sched matic diagram made with computerized printing of fully retro reflective with high intensity prismatic tape pasted on sheet with single side writing including vertical pipe emmebedded in 0.30x0.45mtr in PCC (1:3:6) TYPE C-1 Complete all as specified and directed by the Engi -in -charge. NOTE:- (I) The cost of excavation post hole, earth work, PCC for foundation etc shall be deemed to be included in the unit rate of this item. nothing extra shall be admissible on this account. (ii) the letter size of Main heading shall be minimum 100X10mm and sub heading letter size shall be minimum 50X5mm. (iii) The drawing and colour of writing work shall be got approoved by Engineer-in charge.
M/s Super Trading Corporation
M/S RAGBIR ENGINEERING SERVICES
His Construction Company
M/s Krishan Aggarwal
dhiraaj construction company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .