Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹17.7 L+₹1.6 L (9.90%)Rejected-Finance 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹17.8 L+₹1.7 L (10.7%)Rejected-Finance 30 SHIVTALLA STREET KOLKATA 700 007 | KOLKATA | KOLKATA | WEST BENGAL | 700007 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹18.0 L+₹1.9 L (11.8%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹19.2 L+₹3.1 L (19.2%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
31 Aug 2022, 6:00 pmClosed
GE AF KALAIKUNDA
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
DAY TO DAY MAINTENANCE OF E/M SERVICES AND REPLACEMENT OF ELECTRICAL FITTING, REWIRING AND ALLIED WORKS AT AIR FORCE STATION KALAIKUNDA UNDER GE (AF) KALAIKUNDA
2022_MES_531819_2
8761/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AFS KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹40,000
Yes
1 Nov 2022
18 Aug 2022
1 Sept 2022
18 Aug 2022
31 Aug 2022
26 Aug 2022
Amount
Supply and fix in repair switch piano, flush button, single pole, one way, 5 Amps, complete all as specified and directed.
Supply and fix switch piano, flush button, single pole, one way, 5 Amps, complete all as specified and directed. (Note : Item to be measured if executed under new point wiring)
Supply and Fix, in repair switch socket combination 2 in 1, 5A,flush type, complete all as specified and directed.
Supply and Fix, switch socket combination 2 in 1, 5A,flush type, complete all as specified and directed. (Note : Item to be measured if executed under new point wiring)
Supply and Fix in repair switch socket combined outlet 2 in 1, 3 pin, flush type 5 and 15 Amp universal multi purpose complete all as specified and directed.
Supply and Fix switch socket combined outlet 2 in 1, 3 pin, flush type 5 and 15 Amp universal multi purpose complete all as specified and directed. (Note : Item to be measured if executed under new point wiring)
Supply and fix in repair Ceiling Rose surface bakelite of size 63 x 50 mm, two to three terminal, PVC/ Polycarbonate insulated body, complete all as specified and directed.
Supply and fix Ceiling Rose surface bakelite of size 63 x 50 mm, two to three terminal, PVC/ Polycarbonate insulated body, complete all as specified and directed. (Note : Item to be measured if execuated under new point wiring)
Supply and fix in repairs,bell push, flush type, single pole, 5 Amps, complete all as specified and directed.
Supply and fix ,bell push, flush type, single pole, 5 Amps, complete all as specified and directed. (Note : Item to be measured if executed under new point wiring)
M&L in repair Buzzer electric single phase suitable for 230 Volt complete including taking out unserviceable complete all as specified and directed.
Supply and Fix in repairs, Bell Ding Dong, AC 230 volts, single pole, complete all as specified and directed.
M&L bell ding dong type,AC, 230 volts, single pole complete all as specified and directed (Note : Item to be measured if executed under new point wiring)
M&L in repair lamp holder , PVC/Poly carbonate type with back plate suitable for batten fittings to be fixed on PVC box complete all as specified and directed
M&L lamp holder , PVC/Poly carbonate type with back plate suitable for batten fittings to be fixed on PVC box complete all as specified and directed Make (Note : Item to be measured if executed under new point wiring)
S&F in repair LED bulb 9/10 watt with B22 base, efficiency > 105 lpw, 6500 K complete all as specified and directed . i.Make : Crompton / Wipro / Philips/Century/Havells.
S&F LED bulb 9/10 watt with B22 base, efficiency > 105 lpw, 6500 K complete all as specified and directed . Make : Crompton / Wipro / Philips/ Century/Havells. (Note : Item to be measured if executed under new point wiring)
S&F LED 20 Watt tube light fitting (T8 type) ,single/double end connection type including LED retrofit tube lamp 20 W , 240 Volt, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, IP 20, 2.5 KV internal surge protection complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed by EIC. Make :- Crompton (Batten Cat No.IGP161LT8-16 box type batten suitable for 20 watt retofit LED tube single side connection type). LED lamp : Make : Crompton / Wipro/Philips/Havells/Century/Bajaj. Note : Make of batten and LED tube lamp should be of same make. (Note : Item to be measured if executed under new point wiring)
Taking down old unserviceable TPN / SPN MCB DB's incl MCB of any size and any discription complete all as specified and directed .
S & F sheet metal enclosure for MCB, DB, VTPN 415 Volts,IP-43, 100 amps rated copper busbar 4 way Double door ( Vertical DB with MCB as incomer) Confirming to IS as per IEC 61439-3 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified and directed by Engr-in-charge. . Note: DB and MCCB/MCB shall be of same make.
S&F sheet metal enclosure for VT DB TPN, MCB DB TPN 4 way (with provision for MCCB as INCOMER and MCB as out going), Confirming to IS as per IEC 61439-3, IP 43,double door including 63 Amp, 25 kA,TP MCCB as incomer (Vertical type double door, 63 Amps MCCB rate inclusive) including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified and directed by Engr-in-charge. Make Legrand / Seimens/ Schneider/ Hager/L&T. (Note: DB and MCCB/MCB shall be of same make).
S & F sheet metal enclosure MCB, DB, SPN, 240 Volts, 100 Amps rated copper busbar, Confirming to IS as per IEC 61439-3, 12 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.Make- Legrand/ Seimens/ Schinder/L&T/Hager. Note: DB and MCCB/MCB shall be of same make.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.Make- Legrand/ Seimens/ Schinder/ L&T/Hager. Note: DB and MCCB/MCB shall be of same make.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, Ik09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed .Make- Legrand/ Seimens/ Schinder/ L&T.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 2 way, single door without bus bar, enclosure made up of CRCA sheet steel RAL 9003 powder coated, IP 30 complete all as specified and directed.Make- Legrand/ Seimens/ Schinder/L&T/ABB.
S&F in repair MCB FP/TPN 40 to 63 Amps, 10 KA 'C' Curve breaking capacity, including connection with suitable size copper lugs complete all as specified and directed . Make- Legrand/ Seimens/ Schinder/L&T/ABB/Hager.
S&F in repair MCB FP 100 Amps, 16 KA 'C' Curve breaking capacity, including connection with suitable size copper lugs including complete all as specified and directed .Make- Legrand/ Seimens/ Schinder/L&T/ABB/Hager.
S&F in repair MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size copper lugs complete all as specified and directed by Engr-In-Charge .Make- Legrand/ Seimens/ Schinder/L&T/ABB/Hager.
S&F in repair MCB SPN 6 to 32 amps 10 KA , 'C' Curve including connection with suitable size copper lugs complete all as specified and directed Make- Legrand/ Seimens/ Schinder/L&T/ABB/Hager.
Supply and fixing in repair of stepped type electronic fan regulator 100 watt flush type (delux) on the existing hylem laminated sheet etc as required complete all as specified and directed. Make: Anchor (Delux) / L&T/ Havells/Hager
Supply and fixing of stepped type electronic fan regulator 100 watt flush type (delux) on the existing phenolic laminated sheet etc as required complete all as specified and directed Make: Anchor (Delux) / L&T/ Havells/Hager (Note : Item to be measured if executed under new point wiring)
S&F LED 20 Watt tube light fitting (T8 type) ,single/double side connection type including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2100, lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours as per catalogue No Make :- Crompton /Wipro/Philips/Havells/ Century /Bajaj complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed. . Note : Make of batten and LED tube lamp should be of same make.
S&F LED 2 X 18 Watt tube light fitting (T8 type) , including LED retrofit tube 2 x 18 W , with powder coated CRCA decorative box type batten suitable for surface mounting on wall, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2100, lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours as per catalogue complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.5 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting .and including taking down old unserviceable complete all as specified & directed . Make : Crompton /Wipro/ Philips/Wipro/ Havells/Century/Bajaj. Note : Batten and tube shall be of same Make.
S&F LED tube lamp 18 Watt (reterofit type, T8 pattern, single/double side connection) LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2100, lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete fitting to be fixed in existing or new batten/ patti including changing the wiring suitable for T8 LED retrofit lamp in existing tube light fitting including taking down old unserviceable complete..Make :- Crompton /Philips /Wipro /Havells/ Century/ Bajaj.
S&F in repair LED 20 Watt tube light fitting intergated type, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2100, lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :- Crompton /Wipro /Philips /Havells/Century/Bajaj.
S&F in repair LED 9/10 Watt tube light fitting intergated type, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :- Crompton /Wipro /Philips /Havells/Century /Bajaj.
S&F in repair 18 Watt LED lamp 4 Pin type of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 1800, lumen , , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 65, CRI greater than 80%, ITHD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours necessary change in wiring complete all as specified and directed by EIC. Make : Havells /Crompton/Philips/Wipro/Century/Bajaj.
S&F in repair LED light with pressure die-cast housing along with prismatic polycarbonate diffuser and LED's with secondary optics and colour Temp 5700K ,IP-66 protection ,4KV internal surge protection of 25 watt, PF>0.95, luminaire efficacy >110 lm/ W for building security light complete all as specified and directed by Engineer in charge.including taking down old u/s. Make : Crompton /Philips /Wipro /Havells/Century/Bajaj.
S&F in repair LED bulkhead light with pressure die-cast housing light fittings nominal power 12 watt LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, Luminaire efficiency > 100 lpw, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 65, CRI greater than 80%, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete all as specified and as directed. Make : Crompton /Philips /Wipro /Havells/Century/Bajaj.
S&F LED bulkhead light with pressure die-cast housing light fittings nominal power 12 watt LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 1100, lumen , , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 65, CRI greater than 80%, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete all as specified and as directed. Make : Crompton /Philips /Wipro /Havells/Century/Bajaj. Note :- Item to be measured when new point wiring executed.
Taking down carefully copper/ aluminium submain wirings of any size (2 runs single core including earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size as per IS 694: 2010 with multistranded copper conductor, FRLSH cable drawn in but including non metallic rigid PVC conduit of 25 mm dia ISI marked as per IS 9537 (Part-III): 1983 including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete with colour code all as specified and directed.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4.0 Sqmm size with multistranded copper conductor FRLSH cable as per IS 694: 2010 (with colour code), drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC, including PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and directed.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, FRLSH cable as per IS 694: 2010 drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as continous earth conductor cable connected to earth dolly complete all as specified and directed. .
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm as per IS 694: 2010 (with colour code), drawn in but including PVC casing caping not less than 25 mm width ISI marked double locking type including one including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed by EIC.
M&L for Sub main wiring with Four single core (3 phase) PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size with multistranded copper conductor, FRLS cable drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC including one run of PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete ( 4 x 6.0 sqmm + 1 x 6.0 Sqmm earth wire) complete all as specified and directed
M&L for Sub main wiring with Four single core (3 phase) PVC insulated unsheathed cable 1100 volts grade, 10 Sqmm size with multistranded copper conductor, FRLS cable drawn in but including PVC casing capping not less than 32 mm ISI marked including all accessories of casing caping as approved by EIC including one run of PVC insulated unsheathed 10.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete ( 4 x 10.0 sqmm + 1 x 10.0 Sqmm earth wire) complete all as specified and directed
M&L for repairing distribution box(DB's) of any rating, any size by proper dressing of wirings,providing lugs, screw, nuts , cleaning of the burned surfaces etc, tightening of all the connections of incoming and outgoings from the MCB's/ DB, connecting Earthing connection to each earth dolly including fixing of DB cover by providing screws etc complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC casing caping of min 25 mm dia exclusive of boxes (junction/ terminals) but inclusive of all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles , pipe hook etc to be fixed on surface for dressing of wiring in neat presentable condition by proper relaying of existing PVC cables including removing of cables/ wires and relaying after fixing of new casing capping all as specified and directed,
S& F in repair Rigid non-metallic PVC conduit dia 25 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock,nuts, saddles, pipe hooks etc complete all as specified and directed by EIC.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants,regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc.complete all as specified and directed by Engr-in-charge.
M & L point wiring with 1.5 Sqmm multi stranded copper conductor 1100 V grade,as per IS 694: 2010, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, including sunken in cast iron/MS/GI terminal box duly painted with aluminium paint inside and anticorrosive paint out side with 2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets for the following:- Note : (i) Contractor has to make the surface good after flushing the sunken box as existing without any extra cost (ii) Length or wiring 15 mtrs from switch board to be considered as one point wiring. (iii) Rate of circuit wiring from DB to switch board is included in unit rate of item.
(a) One light/fan/ call bell point controlled by one switch.
(b) One 3 pin socket outlet 5 Amps on independent board.
All as per item No-50 here-in-before but for switch socket combination 15 Amps 3/6 Pin on independent board with 2.5 Sqmm (Nominal area) PVC insulated unsheathed, stranded copper conductor FRLSH cable (1100 Volts grade) complete.
M & L for power point wiring with 4.0 Sqmm multi stranded copper conductor 1100 V grade,as per IS 694: 2010, ISI marked, PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, including all accessories casing caping as approved by EIC, with PVC 4.0 sqmm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, for industrial metal clad socket power point. Note : (i) Length of power point wiring from DB to industrial socket upto 20mtrs distance shall be considered as one point wiring.
Supply and Fix in repair of 3 pin plug top AC-230 v 15 Amp complete all as specified and directed.
S&F in repair single phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V, 5-30 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) in existing position by providing Polycarbonate box cover, including making complete electric connections all as directed specifed and directed by EIC Make : Secure /L&T/ Siemens /Schneider Note : Old meter to be deposite in AGE E/M store.
S&F in repair three phase, 4 wire direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V( P-N) and 400/415V (P-P), 20-100 Amp, sprint 350, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) in existing position by providing Polycarbonate box cover, including making complete electrical connections, connecting PVC cable by providing suitable size copper lugs etc, all as directed specifed and directed by EIC Make : Secure / L&T/ Siemens /Schneider Note : Old meter to be deposite in AGE E/M store.
S & F single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, including taking down old u/s one complete all as specified and as directed. Make : Legrand /Schneider / L&T/ Hager.
S&F in repairs laminated hylam sheet cover, ISI marked with CM/L no., cut with grooves for mounting of fittings like switches, sockets, fan regulators etc. including fixing in loc with new galvanised screw and cup washer complete all as specified and directed by EIC of following sizes.
11 x 13 inches
9 x 11 inches
5 x 8 inches
5 x 5 inches
S&F Hylam sheet ISI marked min 2.8 mm sheet of suitable size as per site requirement to cover the DB box including cut with grooves for operation of MCB including fixing of sheet with providing steel /brass screw and cup washers as required at site complete as directed by Engineer in Charge.
Taking down old ceiling fan/Exhaust fans/Wall mounting fan of any cap/sweep after disconnecting the electric supply from any site, checking for its electrical defect and opening fans for checking of mechanical defect after dismentlling of fan, carried out repair/over hauling including removing dust and grease, and cleaning of internal mechanical parts of fan with kerosene oil, checking of alignment of shaft, oiling and greasing, checking of worn out bearing and other defective parts, winding, condenser etc and re-assembling, and connecting/refixing of fans in its original position by providing new GI nut bolt, lock washer and lock/split pin complete all as specified and directed by Engr-in-charge. NOTE: (i) Rewinding and replacement of defective parts etc shall be measured and paid seperately
Supply only the following spares suitable for ceiling fan/Exhaust fans/Wall mounting fan as per OEMs specifications, complete to be incorcorporated against BOQ Srl item No.62.00 to 67.00 only, if required.
(a) Supply only chrome Steel Ball Bearing, size 6201/6202 suitable for ceiling fans 1200 mm/1400 mm/ 1500 mm sweep as per OEMs specifications, complete.
(b) Chrome Steel Ball Bearing No 6202 Make : SKF/NBC/FAG
(c) Chrome Steel Ball Bearing No 6203 Make : SKF/NBC/FAG
(d) Chrome Steel Ball Bearing No 6204 Make : SKF/NBC/FAG
Supply only,Capacitors for electric fan motors, 2.5 mfd, 220 V conforming to IS:1709 Make Havells /UNIVERSAL / EPCOS or as per OEMs specifications, complete.)
Supply only, Capacitors for electric fan motors, Condenser 4.0 mfd Make Havells /UNIVERSAL/EPCOS or as per OEMs specifications, complete.)
Taking down carefully ceiling fan 1200 mm sweep, dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per direction of Engr-in-Charge, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spares for replacement will be deemed to be included in Quoated rates except bearing and capacitor.
Taking down carefully ceiling fan 1400 mm sweep, dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per direction of Engr-in-Charge, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spares for replacement will be deemed to be included in Quoated rates except bearing and capacitor.
M&L for Rewinding of Exhaust fan of 280/300 mm any make any model , 1400 rpm including taking down ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per direction of Engr-in-Charge, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spares for replacement will be deemed to be included in Quoated rates except bearing and capacitor.
M&L for Rewinding of Exhaust fan of 380 mm any make any model , 1400 rpm including taking down ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per direction of Engr-in-Charge, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spares for replacement will be deemed to be included in Quoated rates except bearing and capacitor.
M&L for Rewinding of Exhaust fan of 450 mm any make any model , 1400 rpm including taking down ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per direction of Engr-in-Charge, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spares for replacement will be deemed to be included in Quoated rates except bearing and capacitor.
M&L for Rewinding of Wall mounting fan of 300 to 400 mm sweep any make any model including taking down ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per direction of Engr-in-Charge, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spares for replacement will be deemed to be included in Quoated rates except bearing and capacitor.
Taking down existing old unserviceable light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , white powder coated CRCA housing with LEDs, seam less front frame with flat white high transmission acrlyic cover, classic design with glare free soft illumination, cool white, having lumen efficacy not less than 100 Lumen/ watt including making electric connection from source with PVC sheathed copper conductor wire and fixing light in celing by all providing all arrangements complete all as specified and directed .Make : Crompton /Philips/ Havells/ Wipro/Century/Bajaj
Supply and Fix in repairs, Modular Switch, one way, 6 Amps, 1 Module, complete all as specified and directed.
Supply and Fix in repairs, Modular Switch, one way, 16 Amps, 1 Module, complete all as specified and directed.
Supply and Fix in repairs, Modular Bell Push, 6 Amps, 1 Module, complete all as specified and directed.
S&F in repair modular socket 6A/16A 2/3 Pin combined -2 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings complete all as specified and directed.
S&F in repair modular switch socket combination 16A , 6 Pin combined -3 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings including complete all as specified and directed.
Supply and Fix in repairs, Modular Fan step regulator, 100W - 2 module,complete all as specified and directed.
Supply and Fix in repairs, Modular Fan step regulator, 100W - 1 module,complete all as specified and directed.
Supply and fixing in repairs wall mounted bed side study lamp aluminium body, 2W LED type warm white including LED driver with on /off button switch ,flexible pipe with lamp head 360 degree rotating type, 220 Volts as per sample complete all as specified and directed by Engr- in- charge.
S & F bracket made of GI light grade pipe 1.2 Mtr long of size 32 mm bore bend to shape as per site requirment fixed to pole with 40 x 5 MM -02 Nos, size clamps bolts, Nuts, washers incuding painting two coats of aluminium paint over a coat of primer all as specified and directed
Note :- (i) For item to be replaced under repair (day to day complaint) contactors trade man should report to E/M complaint cell daily and take complaint from concren JE E/M and after attending complaint he should give feedback and return the complaint slip to concern JE E/M in the evening at 17.30 Hrs on same day. (ii) Tradesman deployed for work should wear proper uniform with full shirt and full Pant. Colour code will be decided by EIC. (iii) For any minor repair required in wiring or their is any fault in circuit where the item under repair is to be replaced, contractor has to identify and recitified the fault without any extra cost. (iv) Contractor must ensure a stock of 25% of total qty as catered in CA or 25% of balance qty of the item as catered in CA (during currency of contract) at the MES provided store. If the contractor not provided said above recovery shall be made as per Terms and Condition of the contract as specified in particular specification. However no ‘Advance on Account’ against this provision as material laying at site shall be admissible.
(v) All LED lights/ flood lights shall be properly connected with earth dolly provided with fittings and earth connection. (vi) All LED lights have replacement warranty of 3 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receiving of 3 year replacement warranty certificate (vii) The LED lights will replaced by the contractor free of cost in the case of manufacturing defects and defects covered in standard warranty policy. (viii) The contractor shall submit the surge protection certificate and type test certificate LM 79, LM 80 for luminaries. (ix) All LED fitting shall be identified by printing or fixing sticker duly mentioned the CA number and date of completion. (x) For any change in product or change in catalogue No. etc due to technological up gradation, letter has to be obtained from the lighting company on their letter head signed by an official of National level. (xi) All T&P required at site for installation of light on Bldg/ hanger or at any location shall be arranged by contractor.
Rate quoated above all items here in before inclusive provision as under :Making arrangement for establishment of centralized complaint centre in the existing building as under :- (a) Infrastructure required in Complaint cell i.e. Computer, printer, telephone, furniture, stationary, transport and other necessary items/materials to establish a complaint centre able to receive and manage complaints from the users by all means ie Manual complaint mechanism, Telephonic complaints mechanism, SMS complaint Mechanism and e-mail complaint mechanism, online complaint mechanism and to maintain a consolidated list of complaints and its redressal mode indicating all its relevant data as directed by Engineer-in-Charge.
(b) Provision and maintenance of all tools, plants, equipment and safety gear required for tradesmen under this contract (c) Provision of communication facilities to supervisor and tradesmen. (d) Monitoring and management of complaints report from generation to execution of complaint including pending complaints. (e) Updating status of lodged complaints before change of eight hour shift. (f) Provision of motorized conveyance for deployment to all tradesmen under this contract. (g) Basic inputs to be noted from the complainants will be locality, Building No, Qtr No, Name and Rank of complaint and exact nature of complaint and mobile No/ telephone or based on inputs provided in the complaint redressal sofware. (h) MES may provide software for generation of complaints. However operation entry, printout and releated activities wrt complaint registry and redressal will be the resposibiity of the contractor. On lodging the complaint, the Complaint No will be assigned for reference . Accordingly a corresponding complaint slip shall be generated by the system with all relevant info. Complaint slip should be printed in triplicate and to be handed over immediately to Supervisor who shall detail appropriate tradesmen for repair with required materials/store. One copy of complaint shall be retained in complaint centre and two copies with tradesmen.
SENCO
SUDHA ENTERPRISES
I.S.ENTERPRISE
M/S C C CONSTRUCTION
SHARMA ENTERPRISES
M/S Jamuna Traders
M/s Santosh Industrial Corporation
Guru Charan Mahata
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .