Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹46.0 L+₹1.0 L (2.24%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹46.6 L+₹1.6 L (3.53%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹49.4 L+₹4.5 L (9.93%)Rejected-Finance | L4 | Rejected-Finance 4TH LOWEST | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected |
Tender Value
₹42.5 L
EMD Value
₹83,000
Closing Date
10 Oct 2022, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
CONSTRUCTION OF DEDICATED WATER PIPE LINE FROM RSHIKULYA RIVER TO GOPALPUR MILITARY STATION UNDER GE I GOS
2022_MES_552942_1
8000/25/22-23/0924/E8
Open Tender
Civil Works
Item Rate
180 days
GOPALPUR-ON-SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹83,000
Yes
10 Nov 2022
19 Sept 2022
12 Oct 2022
19 Sept 2022
10 Oct 2022
3 Oct 2022
Amount
Excavation in trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable/Pole/Stays etc getting out in Soft/Loose Soil complete all as specified and directed.
Excavation in trenches, not exc. 1.50 Metre wide and exc. 1.50 Metre depth but not exc. 3.00 Metre in depth, for Foundation of Poles/ Stays, etc. and getting out in Soft/ Loose Soil, complete all as specified and directed.
Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and directed.
Removing Surplus soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and directed.
M & L clean dry river sand in trenches/ducts for cushioning to cable, 8 cm in depth before laying the cable and 15 cm in depth after laying the cable complete all as specified and directed. Note : Punned thick ness of sand shall be measyred and paid.
M & L Cement Concrete PCC 1:4:8 (using 40 mm graded stone aggregate), type D2 as concrete in foundation of Poles and filling and mass concrete etc, including formwork (as if required), complete all as specified and directed.
M & L Cement Concrete PCC 1:3:6 (using 20 mm graded stone aggregate) type C2 as concrete in foundation of Poles and filling and mass concrete etc, including formwork (as if required), complete all as specified and directed.
M & L Cement Concrete PCC 1:2:4 (using 20 mm graded stone aggregate) type B2 as in coping of pole, for stays etc including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and directed.
M&L for prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l2mm x 279mm at bottom,class 10 complete all as specified and directed.
Supplying and laying unreinforced precast cement concrete cable covers, Class LV, Type- 1, Flat, size 250 mm x 150 mm x 40 mm in trenches for cable protection, embossed with "LT 1100 VOLTS ELECTRIC" on the top surface complete all as specified and directed.
Supply and fixing GI Pipe light grade with all fittings for passing of cables fixed to pole / wall / laid under floor or roads including all fixing accessories complete for protection of cable of following sizes complete all as specified and directed. (a) 100 mm bore
(b) 80 mm bore
(c) 50 MM bore
S & F Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 (using 20 mm graded stone aggregrate ) of size 900 x 300x 100 mm thick with DANGER / 440 VOLTS, LT CABLE /MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work ( as required / ordered at site) complete all as specified and directed.
M & L for RS Joist pole galvanized of size150 mm x150 mm of 12 meter long with MS base plate 6mm thick and of size 300 x 300 welded to bottom of pole, fixing of cross arms, black & yellow colour at lower portion of exposed pole starting from plinth block band of 1200 mm height (4 Nos each Strip of 150 mm width), painting pole No by the black paint by stenciled letters/ figures of 8 cm height complete all as specified and directed. Note:- Earthwork, Cement Concrete, cross arms etc. will be measured and paid under approprite Items.
S & F pin type, polymer/ percelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 Volts grade complete all as specified and directed.
S & F Disc type insulator, polymer/porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, two in series for tension with tension clamps for conductors assembly, working pressure 11000 volts complete all as specified and directed. .
S & F Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) with permissible Sags and providing Jumper etc, fixing on 12 Mtr Electric Poles and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening etc, complete all as specified and directed. Note: Cost of Binding Wire is deemed to be included in the quoted Unit Rate.
M & L for galvanised steel wire 3.15 to 4 mm dia to be stringed as guarding to road crossing under the over head HT lines complete all as specified and directed.
S & F for Anti climbing spikes type fabricated out of MS flat of 50mm x 6mm in two parts with 14 Nos 230 mm long 12 mm dia spikes sharpened edge and including nut,bolts & washers and welding made to shape to suit the cross section of pole including two coat of first grade aluminium paint over a coat of red oxide primer complete all as specified and directed.
S & F for Galvanized Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed complete all as specified and directed.
M & L Stay Assembly complete with Accessories as show in Electrical Plate No. 1 of MES Schedule Part-I, diameter of Stay Rod 20 mm, size of Plate 230 x 230 x 6 mm complete all as specified and directed. Note: Earthwork, Cement Concrete, Mild Steel Stay Clamps with Bolts, Nuts, Stay Strand, Loop Insulator etc. will be measured and paid under approprite Items.
M&L stay stand of size 7/4.0 mm to keep the pole in true vertical position complete all as specified and directed.
S & F Loop Type Insulator Vitreous White, Brown or Green, large size with overall dimensions 90 mm x140 mm, clearance of hole 25.50 mm dia, complete all as specified and directed.
M & L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size complete all as specified and directed.
Supply,laying, testing and commissionnig of UG HT cables, 11000 volts grade, 3 core x 95 sqmm (Earthed), XLPE insulated and PVC shealhed, steel wire armoured, with multi stranded aluminum conductor, heavy duty conforming to latest relevant IS, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes complete all as specified and as directed. (a) 3.5 core x 300 Sqmm (from transformer to Main LT Panel)
(b) 3.5 core x 240 Sqmm (from Main LT Panel to Pump house Panel)
(c) 3.5 core x 120 Sqmm (from Main LT Panel to APFC Panel)
(d) 3.5 core x 70 Sqmm (from transformer to main LT Panel)
(e) 3.5 core x 50 Sqmm (from main LT panel to pump house panel & APFC panel)
S&F cable jointing kit for 11 kV grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE (E) armoured, aluminium conductor cable of size 95 sq mm complete all as specified and directed.
Supplying, installing, fixing, commissioning and testing of Air break gang operated triple pole switch out door type of capacity 200 Amps AC mechanically operated mounted on polymer based insulators and steel frame with operating mechanism worked from ground level complete with locking arrangements incl pad locks with key complete suitable for 11KV, HT, 50 Hz complete all as specified and directed.
Supplying, installing, fixing, commissioning and testing of polymer based Drop-out fuse set (set of 3 nos) 200 Amp AC, mounted on insulators with steel frame with Expulsion fuse carriers and fuse element Upto 25 Amp complete suitable for 11KV, HT, 50 Hz complete all as specified and directed.
S&F Lightening arrestor HT 11 KV, non linear resistor type conforming to IS 3070 (part-1) 1993 complete, line discharge class-3, nominal discharge current 65 KA (peak), 12 KV rated system, voltage peak value high current implus of 4/10 micro Sec wave shape 100 KA (peak) assembly suitable for 11 KV, long duration descharge class-II with insulation level 28/ 75 KV and mounted on hot dip galvanized steel structure including all clamps, nuts, bolts and washers and connecting to earth with 4 mm dia GI wire complete all as specified and directed.
Supply, install, test and commissioning step down transformer, outdoor type, and conforming to IS 1180:2014, level -3, plinth mounted, HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz, delta/ star connected, vector group DYN -11 double copper wound, ONAN, manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5 %, continuous rating of capacity 250 KVA including bushing on HT end cable box on LT side. The Transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil IS 335 ISI marked filtered & dehydrated oil etc, complete all as specified and directed and comprising of the following accessories :- Note:- Transfomer shall be mounted on platform/plinth. (a) Primary HV side suitable for OH conductor(consisting of 3 Nos porcelain HT bushings with brass/gun metal bushing rods complete with nuts and washers). (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No cable gland suitable for reception of outgoing LT armoured cables of suitable size. (c) Oil conservator tank with filter type, drain valve and oil level gauge. (d) Dehydrating breather with first fill of dehydrating agent. (e) Thermometer pocket on tank cover. (f) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device. (g) Rating plate with terminal markings. (h) Two earthing terminals on tank/tank cover to facilitate fixing of 32x6m GI eath strip. (j) Oil Level gauge. (k) Oil drain and filter valves. (l) Oil filler hole with cap/plug with connections complete. (m) Lifting lugs.
(n) Air relief valve plug. (o) Four plan solid cast steel detachable rollers. (p) First fill of fresh oil conforming to relvant IS and tested upto 50 KV dielectric strength upto top of core. (q) Extra bushing for neutal outside the LT cable box for providing independent earthing for neutral. (r) Provision of 2 Nos danger boards 250 x 200mm size made out of 1.6 mm thick MS plate, vitreous enameled white, with letters, figures of vltage and conventional skull and bones in signal red colour, one at HT side and other on LT side. (s) Any other fittings/accessories so as to confirm the whole transformer to IS-1180 Part-I:2014. (t) Construction of Plinth of size 2.0mx 2.0mx1.5m for transformer, using 100 mm thick PCC 1:4:8 type D-2 as in lean concrete, flyash brick masonry in CM 1:6, the top of the plinth shall consist of 100 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) over 75 mm thick PCC 1:4:8 type D-2 over compacted moorum filling, 10 mm thick rendering in CM 1:4 on brick surface with and including 25 cm thick stone aggregates of size 12.5 mm all around upto and including 1.5 m from the edge of the plinth including the RCC Gate and fencing with angle iron post in lieu of RCC post complete all as specified and directed.
Supply, install, test and commissioning step down transformer, outdoor type, and conforming to IS 1180:2014, level -3, plinth mounted, HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz, delta/ star connected, vector group DYN -11 double copper wound, ONAN, manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5 %, continuous rating of capacity 100 KVA including bushing on HT end cable box on LT side. The Transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil IS 335 ISI marked filtered & dehydrated oil etc, complete all as specified and directed and comprising of the following accessories :- Note:- Transfomer shall be mounted on platform/plinth. (a) Primary HV side suitable for OH conductor(consisting of 3 Nos porcelain HT bushings with brass/gun metal bushing rods complete with nuts and washers). (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No cable gland suitable for reception of outgoing LT armoured cables of suitable size. (c) Oil conservator tank with filter type, drain valve and oil level gauge. (d) Dehydrating breather with first fill of dehydrating agent. (e) Thermometer pocket on tank cover. (f) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device. (g) Rating plate with terminal markings. (h) Two earthing terminals on tank/tank cover to facilitate fixing of 32x6m GI eath strip. (j) Oil Level gauge. (k) Oil drain and filter valves. (l) Oil filler hole with cap/plug with connections complete. (m) Lifting lugs.
(n) Air relief valve plug. (o) Four plan solid cast steel detachable rollers. (p) First fill of fresh oil conforming to relvant IS and tested upto 50 KV dielectric strength upto top of core. (q) Extra bushing for neutal outside the LT cable box for providing independent earthing for neutral. (r) Provision of 2 Nos danger boards 250 x 200mm size made out of 1.6 mm thick MS plate, vitreous enameled white, with letters, figures of vltage and conventional skull and bones in signal red colour, one at HT side and other on LT side. (s) Any other fittings/accessories so as to confirm the whole transformer to IS-1180 Part-I:2014. (t) Construction of Plinth of size 2.0mx 2.0mx1.5m for transformer, using 100 mm thick PCC 1:4:8 type D-2 as in lean concrete, flyash brick masonry in CM 1:6, the top of the plinth shall consist of 100 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) over 75 mm thick PCC 1:4:8 type D-2 over compacted moorum filling, 10 mm thick rendering in CM 1:4 on brick surface with and including 25 cm thick stone aggregates of size 12.5 mm all around upto and including 1.5 m from the edge of the plinth including the RCC Gate and fencing with angle iron post in lieu of RCC post complete all as specified, directed by the Engineer-in-charge and as shown on TD drawing No CEPZ/98/TD/6, Sheet No 2/2.
OUTGOING: (a) MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 315 Amps including all fixing accessories with both ends spreader links -01 No (for Pump house panel) (b) MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 160 Amps including all fixing accessories with both ends spreader links -01 No (for APFC panel) (c) MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 63 Amps including all fixing accessories with both ends spreader links -01 No (for spare) (d) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
OUTGOING: (a) MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 100 Amps including all fixing accessories with both ends spreader links -01 No (for Pump house panel) . (b) MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 63 Amps including all fixing accessories with both ends spreader links -02 No (for APFC panel & spare) (d) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
M&L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strip of size 32 x 6 mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel drawn through 40 mm dia light grade GI pipe as shown in electrical plate no 3 of SSR part I of 2009 including necessary excavation and earth work GI pipe 20mm dia medium grade for watering PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to panel board/Gen Set as indicated including testing complete all as specified and directed. Note:- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x 3 mm galvanised iron strip complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep, getting out watering and removing surplus soil to a distance n.exc 50m and making good surface complete all as specified and directed.
M & L for loose filling with aggregate of size 40 mm graded of 20 cm thickness around at 2 pole HT structure complete all as specified and directed.
M& L for Brickwork with straight or curved on plan with subclass ‘B’ bricks, exc 6 m mean radius built in CM 1:6 complete all as specified and directed.
M & L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement water proofing compound complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc. 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm, watering and removing surplus soil to a distance not exc. 50 metre and making good surfaces in soft / loose soil, complete all as specified and directed.
M&L for plain Cement Concrete 1:3:6, Type C-2 of grade using 40mm graded stone aggregate in foundations, filling and mass concrete, etc. for embedding fencing posts, complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire complete all as specified and directed.
Supply only for Chain link MS galvanisd fencing, any size or type complete all as specified and directed.
M& L for Mild steel gate with framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work, portions framed and hung gates, including pintle hinges, stops, hand-made sliding bolts etc as conforming to Fe.290, Gde-E-165 complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth not other wise described and applying two coats of synthatic enamel paint over one coat of red oxide primer complete all as specified and directed.
Supply and providing sand cushioning with dry clean sand of 5 cm below the paver block complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block ISI marked, any shape and size of 60 mm thickness, M-35 Grade laid with grey cement & pigment complete all as specified and directed.
M&L for PCC 1:2:4, type B1 using 20 mm graded stone aggaregate in kerbs/ coping/ bed plates and like including weathering slightly rounded or chamfered complete with necessary use and waste to form work complete all as specified and directed.
M&L for 100 mm thick PCC 1:4:8, type D2 using 40 mm graded stone aggaregate as in subbase complete all as specified and directed.
M/S SPECTRUM INFRASTRUCTURE DEVELOPMENT PVT LTD
M/s Bapujee Builders and Traders
chauhan syndicate
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .