Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹24.2 L+₹79,300 (3.39%)Rejected-Finance A 103 VEERA GARDEN AMBEDKAR NAGAR ALWAR 301001 RAJ | ALWAR | RAJASTHAN | 301001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹24.6 L+₹1.2 L (4.96%)Rejected-Finance KATTI GHATI SHIV COLONY ALWAR ALWAR RAJASTHAN 301001 | ALWAR | RAJASTHAN | 301001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹25.0 L+₹1.6 L (6.90%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹25.5 L+₹2.1 L (8.83%)Rejected-Finance 503 LAJPAT NAGAR ALWAR RAJ 301001 | ALWAR | RAJASTHAN | 301001 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Alwar
Alwar
REPAIR/MAINT OF INTERNAL ELECTRIC SUPPLY AND OTHER MISC WKS AT CITY AREA ALWAR
2025_MES_709552_1
8409/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Alwar
As per NIT
6 documents required · 6 mandatory
₹500
GE Alwar
₹60,000
Yes
2 Aug 2025
22 May 2025
21 Jun 2025
22 May 2025
19 Jun 2025
5 Jun 2025
22 May 2025 - 4 Jun 2025
Amount
Rectifying the defects in LED/ fluroscent tube light fittings/wall security light fitting/flood light fittings/CFL fittings/Building security lights any type/capacity/any shape/position and at any height by tightening loose connections and rectifying defects and made serviceable including testing complete all as directed.
Opening switch mounting plate at normal height upto 1.5 mtr, rectifying the defects in fittings and fixtures such as switches, bell push, fan regulator, sockets etc by tightening loose connections, refixing switch plate and testing complete all as directed. NOTE for Item 1.00 & 2.00: The unit rate quoted shall be deemed to be included the elements of labour only for rectifying and making the fitting and fixtures functional. If replacement of parts/items is required to make the fittings functional, the cost for labour and material for the same will be measured and paid for under relevant items of this schedule hereinafter and in such cases the above items will not be measured and paid for.
Taking down carefully copper/Aluminium point wiring of light/fan/socket/power point and including existing/old conduits / PVC casing caping and making good disturbed surfaces of walls/ ceilings complete all as specified & directed.
M&L for point wiring with Two single core, PVC insulated ,unsheathed FRLS, multistranded copper conductor cable/wire of size 1.5 sqmm,1100 Volts grade along with one single core PVC insulated, unsheathed, FRLS with multistranded copper conductor cable/wire of size 1.5 sqmm 1100 volts grade as continuous earth wire, green in colour confirming to IS-694/1990 connected from fittings to common earth dolly in & including S&F PVC casing & caping/in concealed conduit of suitable size as directed with its accessories and also including S&F wooden switch boards fixed on wall and 3mm thick phenolic laminated sheet top cover for mounting of switches ,sockets, regulators etc. all as specified and directed by Eng-In Charge. Note : The quoted rates are included for cutting and chasing in walls, including making good to disturbed surfaces of concealed wiring.
One light point controlled by one, one way switch in casing/caping.
One light point controlled by one, one way switch in concealed PVC conduit.
One fan point controlled by one switch and regulator in casing/caping.
One fan point controlled by one switch and regulator in concealed PVC conduit.
One exhaust fan point controlled by one switch in casing/caping.
One exhaust fan point controlled by one switch in concealed PVC conduit.
One bell/buzzer point controlled by one bell push in casing/caping.
One bell/buzzer point controlled by one bell push in concealed PVC conduit.
One light point controlled by two, two way switches in casing/caping.
One light point controlled by two, two way switches in concealed PVC conduit.
One 3 pin socket outlet 5 Amps controlled by one switch 5 Amps on same board.
One 3 pin socket outlet 5 Amps controlled by one switch 5 Amps on independent board in casing/caping.
One 3 pin socket outlet 5 Amps controlled by one switch 5 Amps on independent board in concealed PVC conduit.
All as per item No. 4.00 here-in-before but for one 3 pin 15 Amps socket outlet controlled by one 15 Amps switch on independent board with 2.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 volts grade including 2.50 sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 volts grade as continous earth wire in green colour confirming to IS-694/1990 in PVC casing/caping.
All as per item No 4.00 but in concealed PVC conduit.
All as per item No.4.00 here-in-before but for one power point on independent board with 4.00 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 volts grade including 4.00 sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 volts grade as continous earth wire in green colour confirming to IS-694/1990 in PVC casing/caping.
All as per item No 7.00 but in concealed PVC conduit.
S&F switch piano flush type single pole one way 5 Amps 230 Volts .
S&F switch piano flush type single pole two way 5 Amps 230 Volts .
S&F switch piano flush type single pole one way 15 Amps 230 Volts .
S&F socket outlet for 2 & 3 pin 5 Amps flush type 230 Volt.
S&F socket outlet 2 in 1, 3 pin 5 and 15Amps flush type 230V.
S&F bell push flush type 5 Amps 230 Volt.
S&F bell Ding Dong Music type AC 230 volts single pole.
S&F lamp holder PVC/Polycarbonate type with back plate suitable for angle fittings.
S&F ceiling rose surface bakelite 65/30 mm three terminals.
S&F fan regulator electronic stepped up type piano socket type flush type and connecting up, ISI marked 120 Watts, 230 Volts.
S&F switch piano flush type single pole one way 5/6 Amps 230 Volts Modular type.
S&F switch piano flush type single pole one way 15/16 Amps 230Volts Modular type .
S&F socket outlet for 2 & 3 pin 5 Amps flush type 230 Volt Modular type.
S&F socket outlet 2 in 1, 3 pin 5 and 15 Amps flush type 230 V Modular type.
S&F PVC Modular white cover plate with base frame,2 module.
S&F PVC Modular white cover plate with base frame plate 3 module.
S&F PVC Modular white cover plate with base frame plate 4 module.
S&F PVC Modular white cover plate with base frame plate 6 module.
S&F PVC Modular white cover plate with base frame plate 8 module.
S&F fan regulator electronic stepped up type piano socket type flush type and connecting up ,ISI marked 120 Watts, 230 Volts,modular type, 2 module.
S&F in repair decorative ultra slim liner LED lighting fixture with extended polycarbonate 20 Watt with LED tube and connecting up with and including white coloured round three core ,PVC insulated ,sheathed copper conductor cable of required size and length from ceiling rose to fitting and as directed .
S&F in repair decorative ultra slim square box profile liner LED lighting fixture with extended polycorbonate ,environmental friendly ,energy efficient all including LED tube 9 watt,6000K to 6500K of Model ELITE LED PRIDE and connecting up with and including white coloured flat/round twin core PVC insulated, PVC sheathed copper conductor cable of required size and length, from light fitting to ceiling rose specified & directed.
Refixing of existing LED light fitting of any type and any size including necessary fixing accessory and white coloured round three core, PVC insulated, sheathed copper cable of required size and length from ceiling rose to fitting complete with all standard fitting .
S&F sheet metal enclosure double door type suitable for fixing MCB's, TPN 4 way, 415 Volts and including taking down old U/S DB ,TPN,4 way complete all as specified & directed.
S&F sheet metal enclosure double door type suitable for fixing MCB's, TPN 8 way, 415 Volts and including taking down old U/S DB ,TPN, 4/8 way complete all as specified & directed.
S&F sheet metal enclosure double door type suitable for fixing MCB's, SPN with 200 Amps rated bus bar,8 way, 230 Volts and including taking down old U/S DB ,SPN,8 way complete all as specified & directed.
S&F sheet metal enclosure double door type suitable for fixing MCB's, SPN with 200 Amps rated bus bar,4 way, 240 Volts and including taking down old U/S DB ,SPN 4way complete all as specified & directed.
S&F sheet metal enclosure single door type suitable for fixing MCB's, SPN without busbar 2 way, 230 Volts and including taking down old U/S DB ,SPN 2way complete all a specified & directed.
S&F MCB 32 Amp, single pole & neutral, 230 Volt & including taking down old U/S MCB complete all a specified & directed.
S&F MCB 6 to 32 Amp, single pole 230 Volt & including taking down old U/S MCB complete all a specified & directed.
S&F MCB 32 to 63 Amp, triple pole & neutral, 415 Volt & including taking down old U/S MCB complete all as specified & directed.
S&F 2nd class H/W rectangular block open recessed of size 45mm x30mm X 5 cm depth fixed with suitable screws & PVC rawl plug (4 Nos) for DB complete all as specified and directed.
S&F 2nd class H/W rectangular block open recessed of size 30mm x25mm X 5 cm depth fixed with suitable screws & PVC rawl plug (4 Nos) for DB comlpete all as specified and directed.
Supply,installing and testing in repair out door wheather proof bus bar chamber of size 60cmx40cmx40cm made out of 3.15mm MS sheet having one side openable hinged door shutter with locking arrangement &provn of two Nos 60cm long 40x40x6mm angle iron legs welded and 4 Nos Aluminium bus bar of 200 Amp rating and incoming MCCB 63 Amps adjustable thermal magnetic release type complete errected on ground with necessary PCC 1;3;6 type C-2 foundation complete bus bar chamber painted with two coats of approved enamel paints over one coat of primer including making cable connection with necessary gland ,lugs/thimbles complete all as specified and directed.
S&F sub main wiring in and including PVC conduit with PVC flexible copper conductor unsheathed multistranded two single core cable of size 6 Sqmm and coninuous earth with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 sqmm of green colour confirming to IS-694/1990 including taking down existing unserviceable sub main wiring (Two runs of cable with one run of earth wire shell be measured as one length) incl taking down old submain wiring complete all as specified & directed.
S&F sub main wiring in and including PVC conduit with PVC flexible copper conductor unsheathed multistranded two single core cable of size 4 Sqmm and coninuous earth with PVC flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm of green colour confirming to IS-694/1990 including taking down existing unserviceable sub main wiring (Two runs of cable with one run of earth wire shell be measured as one length) incl taking down old submain wiring complete all as specified & directed.
S&F sub main wiring in and including PVC conduit with PVC flexible copper conductor unsheathed multistranded four run single core cable of size 6 Sqmm and coninuous earth with PVC flexible cable copper conductor unsheathed multistranded two run single core of size 6 sqmm of green colour confirming to IS-694/1990 including taking down existing unserviceable sub main wiring (Four runs of cable with two run of earth wire shell be measured as one length) incl taking down old submain wiring complete all as specified & directed.
S&F sub main wiring in and including PVC conduit with PVC flexible copper conductor unsheathed multistranded four run single core cable of size 10 Sqmm and coninuous earth with PVC flexible cable copper conductor unsheathed multistranded two run single core of size 6 sqmm of green colour confirming to IS-694/1990 including taking down existing unserviceable sub main wiring (Four runs of cable with two run of earth wire shell be measured as one length) incl taking down old submain wiring complete all as specified & directed.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with 01 No. single pole MCB 20 Amps & including taking down old U/S enclosure complete all as specified & directed .
S&F recess 36/40 watt ultra slim edge 2x2 feet lit panel in aluminium casing recess mounted square fixture in white finish suitable for low ceiling height ,3in1,3K,4K,6K with & including LED prewired & connecting up & dismantling of old U/S recess mounted light.
S&F MCCB 4 Pole ,100 Amps rating rupturing capacity 25 KA ,415 volts grade AC,50 HZ magnetic fixed type and making connections including disconnecting & taking down old U/S ,MCCB complete ,all as specified and directed.
S&F MCCB 4 Pole ,63 Amps rating rupturing capacity 16 KA ,415 volts grade AC,50 HZ magnetic fixed type and making connections including disconnecting & taking down old U/S ,MCCB complete ,all as specified and directed.
Disconnecting electric connections and taking down existing electric meter from wooden board ,and S&F new wooden board of size and Reconnecting ,Refixing existing meter to the location as specified & directed.
S&F On load Changeover switch front operated 100 Amp ,AC ,3 Phase 4-pole 415 volts, including taking down old U/S changeover switch.
S&F On load Changeover switch front operated 250 Amp ,AC ,3 Phase 4-pole 415 volts, including taking down old U/S changeover switch.
S&F switch piano flush type single pole ,one way ,5 Amp 230 volts ,fixed in repairs all including taking down old UNSV switch any type and connecting up complete all as specified & directed.
S&F switch piano flush type single pole ,two way ,5 Amp 230 volts ,fixed in repairs all including taking down old UNSV switch any type and connecting up complete all as specified & directed.
S&F switch piano flush type single pole ,one way ,15 Amp 230 volts ,fixed in repairs all including taking down old UNSV switch any type and connecting up complete all as specified & directed.
S&F switch bell push type single pole ,5 Amp 230 volts ,fixed in repairs all including taking down old UNSV switch any type and connecting up complete all as specified & directed.
S&F socket outlet for 2&3 pin,5 Amp flush type 230 Volts ,fixed in repairs all including taking down old UNSV socket any type and connecting up complete all as specified & directed.
S&F socket outlet for 2 in 3 pin 15 Amp flush type 230 Volts ,fixed in repairs all including taking down old UNSV socket any type and connecting up complete all as specified & directed.
S&F electric bell Ding Dong type AC,230 Volts ,single pole ,fixed in repairs all including taking down old UNSV bell any type and connecting up.
S&F angular/batten lamp holder, polycarbonate body with back plate suitable for batten fitting ,fixed in repairsall including taking down old UNSV holder any type and connecting up complet all as specified & directed.
S&F electronic, stepped up & socket type fan regulator ,0-4 step of cap. 100 watt ,230 volts AC,fixed in repairs all including T/D old UNSV regulator any type and connecting up complete all as specified & directed.
S &F ceiling rose surface bakelite 65x50mm ,two or three terminals ,fixed in repairs all including taking down old UNSV switch any type and connecting up complete all as specified & directed.
S&F MCB 32 to 63 Amps ,SPN, 230 Volts fixed in repair all including taking down old UNSV MCB any type and connecting up.
S&F ,MCB 6 to 32 Amps ,SP,230 Volts fixed in repair all including taking down old UNSV MCB any type and connecting up.
S&F ,MCB 32 to 63 Amps ,TPN,415 Volts fixed in repair all including taking down old UNSV MCB any type and connecting up.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.30mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre,charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & directed & including taking down earth plate.
S&F sealed dry type battery Cap. 65 AH 12 volt type Make -Exide model Powersafe Plus No EP 65-12 & taking down old U/S battery all as specified and directed.
Servicing of UPS 10 KVA by blower in existing location ,open connection checking the IC and including replacement of U/S spare parts if any Mass Pad,control card,power card etc complete all as specified and directed by Engineer-in-Charge
Supply, laying, jointing and testing in repair XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified & directed. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply, laying, jointing and testing in repair XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified & directed. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply and Fixing in repair LED Bulb energy saving 10/11 W complete all as specified and directed.
Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 Sqm on plan and getting out in soft/loose soil.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified.
M&L for brick work with FLY ASH BRICKS(As Per IS-13757(1993) burnt clay fly ash building bricks), (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and complete all as specified & directed.
M&L for dry sand and punning for cushioning to under ground cable all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
M&L in reapir for GI pipe (Light grade) for protection of LT cable fixed to walls/ poles/road crossing including clamps complete of 40 mm bore as specified & directed.
S&F in repair PVC Rectangular box with 5A flush type 2 in 1 switch socket combination complete all as specified and directed.
S&F in repair PVC Rectangular box with 15A flush type 2 in 1 switch socket combination 240 V complete all as specified and directed.
S&F in replacement 3 pin 15 Amps Plug Top 250 Volts heavy duty complete all as specified and as directed.
S&F in replacement 3 pin 5 Amps Plug Top 250 Volts heavy duty complete all as specified and as directed.
S&F in repair LED light fitting 10 Watt 2 feet mirror light luminarire with poly carbonate cover complete with all acessories and driver including connections with with 3 core copper wire of suitable size complete all as specified and directed.
S&F in replacement of unserviceable 10 Sqmm aluminium service wire 2 core fixed to wall/ceiling using clamps of suitable size including removing the existing for replacement complete all as specified and as directed.
S&F in replacement of unserviceable 6 Sqmm aluminium service wire 2 core fixed to wall/ceiling using clamps of suitable size including removing the existing for replacement complete all as specified and as directed.
S&F in replacement of unserviceable 4 Sqmm aluminium service wire 2 core fixed to wall/ceiling using clamps of suitable size including removing the existing for replacement complete all as specified and as directed.
S&F in replacement of unserviceable 2.5 Sqmm aluminium service wire 2 core fixed to wall/ceiling using clamps of suitable size including removing the existing for replacement complete all as specified and as directed.
S&F in repair LED light fitting, 1X25 watt, complete with tuff net glass protection IP:66, fixed to walls with GI bracket made out of suitable size of light grade pipe 32 mm dia tubing upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of 25x3 mm MS flat iron with suitable bolt and nuts and testing etc complete all as specified and directed.
S&F in repair 3 watt metal and synthetic LED bedside flexible reading lamp. The lamp shall be of warn white/yellow light with dimensins 5.5cm x 5.5cm x 14.6cm with two year manufacturer warranty from their manufacturer/authorised dealer. Note : The quoted rate shall include the point wiring and wiring arrangments required for fixing of the lamp including labour rate adn other misc charges.
S&F in repair 20 Watt motion sensor batten (aluminium housing) for carridors based on auto dimming/ brightness option by motion sensor via in buildt sensor for efficient use of energy.
S&F in repair inverter LED batten 20 Watt (PC body) with opal diffuser, IP-20 and inbuilt battery backup with powerful lithium battery. LED batten shall have atleast four hours backup with minimum two years warranty from their manufacturer/authorised dealer. The batten shall have deep discharge protection, fast charging, offering cool day light for atleast four hours in off hours.
S&F in repair 20 Watt emergency LED inverter bulb B-22 capacity with inbuilt powerful lithium battery backup of atleast 4 hours and having minimum two years warranty from their manufacturer/authorised dealer. The lighting shall have deep discharge protection, fast charging, offering cool day light for atleast four hours in off hours.
S&F 10-12 Watt emergency LED inverter bulb B-22 capacity with inbuilt powerful lithium battery backup of atleast 4 hours and having minimum two years warranty from their manufacturer/authorised dealer. The lighting shall have deep discharge protection, fast charging, offering cool day light for atleast four hours in off hours.
S&F 8-9 Watt emergency LED inverter bulb B-22 capacity with inbuilt powerful lithium battery backup of atleast 4 hours and having minimum two years warranty from their manufacturer/authorised dealer. The lighting shall have deep discharge protection, fast charging, offering cool day light for atleast four hours in off hours.
All rounder base B22D 15W, 8W, 0.5W multi wattage adjustable light led bulb white and yellow in color.
Supply & fix in repair recess type, 36 watt LED panel light (600x600 mm) complete with fittings integrated electronic driver,energy efficient, 230 volts,co- related colour temperature (CCT) of 6500K, warm white/ cool white/natural white complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge.
Supply and fixing in replacement of unserviceable garden lights with LED landscape luminaires 10 Watts pressure die cast powder coated housing with PC diffuser,Efficient high output COB for garden, Pathway lightning, IP 66 protection complete all as specified and directed.
S&F in replacement of unserviceable 35W LED Post top made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP65 protection complete with all accessories suitable for connection of copper wires complete all as specified and directed.
Supply and fix in replacement Intelligent, flexible & smart outdoor lighting control unit for automatic switch ON at dusk automatic switching OFF at Dawn with Astronomical Time Switch, high voltage and low voltage protection, 3 Pole / 230V For 12 KW load equally distributed over 3 phases. Minimum IP54 Degre of Protection.
S&F in repair of 45watt Inverter LED Light with IR Sensor for automatic On-Off of street light and shall have inbuilt Li-on battery for 90mins power backup in case of power failure. Housing of fixture shall be presurre die cast and system efficacy >100LPW, CRI >70, CCT 5700K, PF>0.9, THD<15%.
Supply only in repair surge protector 10 kA with IP 65 protection, as per IS
Supply only in repair driver suitable for 45 watt LED with IP 65 protection, as per IS
Supply only in repair driver suitable for 60 watt LED with IP 65 protection, as per IS
Supply only in repair driver suitable for 90 watt LED with IP 65 protection, as per IS
Supply Installation Testing and Commissioning in replacement of Lithium based Solar LED Security light System with built in Battery and PV Panel and LED lamp in FRP/Aluminium body including taking down of old unserviceable light fitting of any size/capacity complete. System Comprises Followings”:- 1. PV Panel 30W Monocrystalline. 2. Lithium Cell for back up 15.4AH with inbuilt BMS. 3. High brightness W-LED lamp 16W, CRI>700, CCT6500K. 4. Microcontroller based charge controller cum driver with automatic dimming function, Dusk to Dawn Operation. 5. Working temperature: (-) 10°C to (+) 55°C. System should be supplied with adjustable MS clamp and 40mm dia arm suitable for pole/wall mounting complete with satisfaction of Engineer In Charge.
Hitesh Construction (BID ID -3321401)
M/s Yash Electrical and Maintenance (BID ID -3321121)
DEMROT ELECTRICAL WORKS (BID ID -3329731)
ALAKNANDA ENTERPRISES (BID ID -3321154)
Shiv Enterprises (BID ID -3319703)
M/S GUPTA ENTERPRISES (BID ID -3329756)
Deep Contractor (BID ID -3321425)
Choudhary Traders and Engineers (BID ID -3328720)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .