Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹46.4 LAccepted-AOC | ₹46.4 L Quoted ₹49.0 L | L-1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER |
| 2 | L-2₹51.3 L+₹2.3 L (4.63%)Rejected-Finance AT ROAD SANTIPUR GUWAHATI 781009 ASSAM | GUWAHATI | KAMRUP METRO | ASSAM | 781009 | ₹51.3 L+₹2.3 L (4.63%) | L-2 | Rejected-Finance BEING L2 BIDDER |
| 3 | L-3₹52.1 L+₹3.1 L (6.36%)Rejected-Finance | ₹52.1 L+₹3.1 L (6.36%) | L-3 | Rejected-Finance BEING L3 BIDDER |
| 4 | L-4₹53.9 L+₹4.9 L (10.1%)Rejected-Finance THIS INFORMATION IS NOT AVAILABLE IN THE PROVIDED DOCUMENT | KAMRUP METRO | ASSAM | 781005 | ₹53.9 L+₹4.9 L (10.1%) | L-4 | Rejected-Finance BEING L4 BIDDER |
| 5 | L-5₹57.5 L+₹8.5 L (17.3%)Rejected-Finance | ₹57.5 L+₹8.5 L (17.3%) | L-5 | Rejected-Finance BEING L5 BIDDER |
| Sl No | Description | Qty | Unit | KAKWANI BUILDERS L1 | BALEN DEWAN L2 | M/s KRISHNA CONSTRUCTIONS L5 | OM CONSTRUCTIONS L3 | G.K. TRADERS L6 | M/s Narzary Enterprise L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge. | 195 | CUM | 220 ₹42,900 | 275 ₹53,625 | 235 ₹45,825 | 185 ₹36,075 | 240 ₹46,800 | 157.5 ₹30,712.5 Lowest |
| 2.00 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm, including dipositing the surplus soil along the line of pipe/ cable in the form of heap, complete all as per specified and as directed by Engineer-in-charge. | 153 | CUM | 210 ₹32,130 | 275 ₹42,075 | 210 ₹32,130 | 195 ₹29,835 | 220 ₹33,660 | 131.25 ₹20,081.25 Lowest |
| 3.00 | M&L for laying 32mm dia (Outer) 3- layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply with all PP-R plain & brass threaded fittings laid in trenches including taking down the existing old unserviceable CI/GI/MS/PP-R pipe and testing, complete all as specified and as directed by Engineer-in-charge. | 60 | RM | 275 ₹16,500 | 275 ₹16,500 | 287 ₹17,220 | 265 ₹15,900 | 290 ₹17,400 | 162.75 ₹9,765 Lowest |
| 4.00 | All as per Item No. 03 here-in-above, but for 50mm dia (Outer) pipe, complete all as specified and as directed by Engineer-in-charge. | 100 | RM | 795 ₹79,500 | 700 ₹70,000 Lowest | 800 ₹80,000 | 758 ₹75,800 | 750 ₹75,000 | 778.05 ₹77,805 |
| 5.00 | All as per Item No. 03 here-in-above, but for 63mm dia (Outer) pipe, complete all as specified and as directed by Engineer-in-charge. | 100 | RM | 1,200 ₹1,20,000 | 1,040 ₹1,04,000 Lowest | 1,150 ₹1,15,000 | 1,050 ₹1,05,000 | 1,200 ₹1,20,000 | 1,104.6 ₹1,10,460 |
| 6.00 | All as per Item No. 03 here-in-above, but for 90mm dia (Outer) pipe, complete all as specified and as directed by Engineer-in-charge. | 60 | RM | 2,500 ₹1,50,000 | 2,150 ₹1,29,000 Lowest | 2,500 ₹1,50,000 | 2,250 ₹1,35,000 | 2,650 ₹1,59,000 | 2,261.7 ₹1,35,702 |
| 7.00 | All as per Item No. 03 here-in-above, but for 110mm dia (Outer) pipe, complete all as specified and as directed by Engineer-in-charge. | 60 | RM | 3,600 ₹2,16,000 | 3,200 ₹1,92,000 Lowest | 3,620 ₹2,17,200 | 3,500 ₹2,10,000 | 3,700 ₹2,22,000 | 3,413.55 ₹2,04,813 |
| 8.00 | S&F of 20mm dia galvanised steel tubes, 'medium grade', with all fitting; laid in trenches, including taking down the existing old unserviceable CI/GI/MS/PP-R pipe and testing, complete all as specified and as directed by Engineer-in-charge. | 20 | RM | 275 ₹5,500 | 245 ₹4,900 Lowest | 275 ₹5,500 | 255 ₹5,100 | 250 ₹5,000 | 266.7 ₹5,334 |
| 9.00 | All as per Item No. 08 here-in-above, but for 25mm dia GI pipe, complete all as specified and as directed by Engineer-in-charge. | 20 | RM | 385 ₹7,700 | 345 ₹6,900 Lowest | 400 ₹8,000 | 350 ₹7,000 | 350 ₹7,000 | 373.8 ₹7,476 |
| 10.00 | M&L for laying 25mm dia (Outer) 3- layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply with all PP-R plain & brass threaded fittings fixed to wall including taking down the existing old unserviceable CI/GI/MS/PP-R pipe and testing, complete all as specified and as directed by Engineer-in-charge. | 60 | RM | 175 ₹10,500 | 125 ₹7,500 Lowest | 175 ₹10,500 | 150 ₹9,000 | 160 ₹9,600 | 155.4 ₹9,324 |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
18 Jun 2025, 6:00 pmClosed
GE Rangia
GE Rangia C/O 99 APO Rangia
REPAIR TO EXTERNAL WATER SUPPLY PIPE LINE, PUMP SET, CLEANING OF OH TANKS AT HATTIGOR AND REPAIR TO DG SET, VOLTAGE STABILIZER AND CONNECTED WORKS AT TAMULPUR, DARRANGA AND HATTIGOR MIL STN UNDER GE RANGIA
2025_MES_711297_1
8913/RNG/E8
Open Tender
Pipes and Pipe related activities
Item Rate
270 days
Tamulpur, Darranga, Hattigor
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Rangia
₹91,000
Yes
2 Sept 2025
29 May 2025
20 Jun 2025
29 May 2025
18 Jun 2025
13 Jun 2025
29 May 2025 - 5 Jun 2025
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm, including dipositing the surplus soil along the line of pipe/ cable in the form of heap, complete all as per specified and as directed by Engineer-in-charge.
M&L for laying 32mm dia (Outer) 3- layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply with all PP-R plain & brass threaded fittings laid in trenches including taking down the existing old unserviceable CI/GI/MS/PP-R pipe and testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 03 here-in-above, but for 50mm dia (Outer) pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 03 here-in-above, but for 63mm dia (Outer) pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 03 here-in-above, but for 90mm dia (Outer) pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 03 here-in-above, but for 110mm dia (Outer) pipe, complete all as specified and as directed by Engineer-in-charge.
S&F of 20mm dia galvanised steel tubes, 'medium grade', with all fitting; laid in trenches, including taking down the existing old unserviceable CI/GI/MS/PP-R pipe and testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 08 here-in-above, but for 25mm dia GI pipe, complete all as specified and as directed by Engineer-in-charge.
M&L for laying 25mm dia (Outer) 3- layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply with all PP-R plain & brass threaded fittings fixed to wall including taking down the existing old unserviceable CI/GI/MS/PP-R pipe and testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 10 here-in-above, but for 32mm dia (Outer) pipe, complete all as specified and as directed by Engineer-in-charge.
S&F of 20mm dia galvanised steel tubes, 'medium grade', with all fitting; fixed to walls and ceilings or laid in floors, including taking down the existing old unserviceable CI/GI/MS/PP-R pipe and testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 12 here-in-above, but for 25mm dia GI pipe, complete all as specified and as directed by Engineer-in-charge.
M&L for DI fittings for DI pipe flange/ spigot and socket of size 100 mm to 350 mm bore such as bends(any type,radius and angle) tapers any type (straight, bend, increasing,decreasing or double socket etc) Tee pieces single branch, 'Y' junction, double branch, cross(all sockets or socket and spigot) collars caps and plugs complete all as specified and directed.
Supply ,fixing and testing of MS ERW pipe of nominal dia 100 mm inclduing fittings and laid in trenches complete as per IS 3589 (1981) having thickness 6.0mm including taking down the existing old unserviceable CI/GI/MS/PP-R pipe and testing, complete all as specified and as directed by Engineer-in-charge.(making of flanges, welding, tapering to desire shape, Rubber gasket all shall be deemend in the quoated rate)
S&F in-repair of 25mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 16 here-in-above, but for 32mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 16 here-in-above, but for 50mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 16 here-in-above, but for 63mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of straight plain brass ferrules of 20mm dia (or connecting screws) screwed both ends and fixed, complete all as specified and as directed by Engineer-in-charge.
Supply & Fixing, jointing and testing of cast iron sluice Valve ISI mark (PN-1.6) of size 150 mm bore (Internal Dia) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets including taking out old unserviceable sluice valves, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 21 here-in-above, but for 100mm bore (Internal Dia) CI Sluice valve having gun metal spindle, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 21 here-in-above, but for 80mm bore (Internal Dia) CI Sluice valve having gun metal spindle, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 20 mm bore (Internal Dia), gun metal gate valves with iron wheel head, screwed both ends for iron/ PP-R pipe, ISI Marked, as per IS: 778, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 24 here-in-above, but for 25mm bore (Internal Dia) gun metal gate valves, complete all as specified and as directed by Engineer-in-charge.
Supply & Fixing, jointing and testing of cast iron Non Return Valve (NRV) ISI mark (PN-1.6) of size 100 mm bore, without bypass arrangement, swing type, conforming to IS-5312, complete with nuts, bolts, washers and gaskets including taking out old unserviceable NRV, complete all as directed by Engineer-in-charge.
Supply and Fix CI butterfly valve 150 mm dia without lugs, lever operated CI disc, EPDM rubber lining including taking out old unserviceable one, complete all as directed by Engineer-in-charge.
Supply and Fix CI butterfly valve 100 mm dia without lugs, lever operated CI disc, EPDM rubber lining including taking out old unserviceable one, complete all as directed by Engineer-in-charge.
M&L for construction of Brick Masonry Valve Pit, of size 1200mm X 1200mm X 1200mm (Internal dimension), one Brick thick wall in cement mortar 1:4 on 150mm thick PCC 1:4:8, type D-2 (40mm graded aggregate) in Foundation, Rendering 15mm thick in CM 1:4 internally upto full depth and externally upto 150mm below GL and sbove wall, providing 3mm thick MS black Sheet Valve Pit Cover, welded with 40X5mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 40 x 40 x 6mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230 x 200 x 100 mm, applying two coats of Synthetic enamel Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed to Steel Surfaces including necessary Earth Work in Soft/Loose Soil and demolition of old unserviceable Valve Pit, complete all as directed by Engineer-in-charge.
All as per Item No. 29 here-in-above, but for Brick Masonry Valve Pit, of size 900mm X 900mm X 900mm (Internal dimension), complete all as specified and as directed by Engineer-in-charge.
S&F in repair fully automatic star delta starter 30 HP in sheet metal encloser type MN with single phase protection feature, AC 3 Phase 415 Volt 50 Hz, complete all as specified and diredted by Engineer-in-charge. Make Havells/Standard/L&T/Indoasian
S&F in repair fully automatic star delta starter 20 HP in sheet metal encloser type MU-G with single phase protection feature, AC 3 Phase 415 Volt 50 Hz, complete all as specified and diredted by Engineer-in-charge. Make Havells/Standard/L&T/Indoasian
S&F in repair of combined digital voltmeter and ammeter as per existing size suitable for motor starter/ APFC Panel, complete all as specified and diredted by Engineer-in-charge. Make Havells/Standard/L&T/Indoasian
S&F in-repair of pressure gauge 3'' dial 0-2.5 kg/cm² rating complete with nuts, bolts, washers and gaskets, complete all as directed by Engineer-in-charge.
S&F in-repair of route indicator made of cast iron, suitable for water supply pipe line with 35x35x4mm thick MS angle iron post of 1.0m long embedded in PCC 1:3:6 type C-1 (20mm graded aggregates) as in bed block of 150x150x300mm deep, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of FRP solution preparation cum settling tank with sludge deposition facility fitted with PVC agitator of capacity 100ltrs with lid, port hole, inlet and outlet drain connection, level gauge and fitted with 900 RPM motor for proper mixing of chemical solution facility including suitable size of connection pipes as per manufacturer's recommendation for inlet-outlet pipes, etc. including providing necessary connection to the end terminal, complete all as specified and as directed by Engineer-in-charge.
M&L for re-winding of 0.5/1.0 HP Chemical dosing motor after disconnecting motor from dosing drum, taking out brunt winding wire of field coil and re-winding of field coil with super enamelled copper wire of suitable size with necessary insulation materials and re-fixing motor on drum with new nut-bolts and necessary connection to the terminal, complete all as directed by Engineer-in-charge.
M&L for applying two coats of synthetic enamel paint (1st quality) by spray painting of existing colour on pump, motor, channel frame, inlet-outlet GI/ MS pipe line of pump house after necessary cleaning and preparation of surfaces, complete all as directed by Engineer-in-charge.
M&L for surface preparation for paint of inner surface of water tank sheet after removing all foreign particals from steel surfaces by srubbing the wall with iron scrubber and apply two coats of black bituminous paint over a coat of primer suitable for drinking purpose in pressed steel water tank on 40 feet staging on inner wall of tank, roof sheet, manhole cover, channels, tie rod etc complete all as specified and as directed by Engineer-in-charge. Note- Cost of scaffolding, T&P and any material required to complete the job as per the direction of Engineer -in-Charge shall be deemed to the quoted rate.
M&L for surface preparation for paint of Outer surface of water tank sheet after removing all foreign particals from steel surfaces by scrubbing the wall with iron scrubber and apply two coats of synthetic enamel paint over a coat of primer in pressed steel water tank on 40 feet staging on all outer wall sheet of tank, roof sheet, channels, trusses, coloumn and iron structure holding the tank, tie rod etc complete all as specified and as directed by Engineer-in-charge. Note- Cost of scaffolding, T&P and any material required to complete the job as per the direction of Engineer- in-Charge shall be deemed to the quoted rate.
M & L for writing the letters "PS TANK CAP 45000 Ltrs" and " SAVE WATER" on the tank having 40 feet staging with white synthetic paint on front side and "MES" on other side. Size of letter shall be 25-30 cm complete all as specified and directed.
M&L for complete servicing, greasing of the pump motor sets of capacity upto 30 HP by dismantling from the position,unscrewing nut bolt, bushes, cleaning, greasing and replacement of unsv bushes, gasket, gland packing/water seals, oil ring, nut bolts of suitable size including re-assembling the same in position and connect to the both end terminal circuit testing and commissioning complete all as directed. (Note:- 1. Arrangement of necessary T&P items required for dismantaling and reassembling pump motor set shall be deemend to be included in the quoted rate. 2. Cost of new bushes, gasket, gland packing nut bolts etc shall be deemened to be included in the quoated rate.)
M&L for dismantling centrifugal pump of capacity upto 30 HP from motor and inlet outlet GI pipes and taking out for workshop for repair of impeller,casing water seal, shaft etc complete all as specified and directed.
M&L for re-winding of capacity upto 30 HP induction motor disconnecting motor from pump, taking out burnt winding wire of field coil and re-winding of field coil with suitable size of super enameled copper winding wire with necessary insulation materials including change of Key for motor coupling, Gasket complete overhauling and re-fixing motor, pump on frame with new nuts bolts etc and necessary connection to the terminal complete all as directed.
M&L for re-winding of submersible motor of capacity uto 20 HP after lifting up of submersible pump set including column pipe from bore well, disconnecting motor from pump, taking out burnt winding wire of field coil and re-winding of field coil with suitable size of super enameled copper winding wire of same gauge with necessary insulation materials including complete overhauling and lowering of submersible set with column pipe in the borewell with new nuts bolts gasket etc and necessary connection to the terminal complete all as directed.
S&F in repair of ball bearing suitable for pump of capacity upto 30 HP as per existing model and make, complete all as specified and directed.
S&F in-repair of shaft stainless steel alongwith key and check nut suitable for induction motor of any type as per existing model and make, complete all as specified and directed.
S&F in-repair of PVC insulated three core sheathed submersible flat cable of size 10 Sqmm for submersible pumps with copper conductor 1100 Volts grade conforming to IS:694/1990 ISI all as specified and directed.
S&F in-repair of chlorine test kit with coloured ample complete with all testing fitments and OT solution in rexine finished box, coomplete all as specified and as directed by Engineer-in-charge.
S&F in-repair of pH test kit with coloured ample covered under phenol red (range 6.8 to 8.4) with necessary fitments and 100ml testing solution in rexine finished box, coomplete all as specified and as directed by Engineer-in-charge.
S&F in-repair of hardness test kit with necessary testing solution in rexine finished box, coomplete all as specified and as directed by Engineer-in-charge.
S&F in-repair of iron test kit with necessary testing solution in rexine finished box, coomplete all as specified and as directed by Engineer-in-charge.
S&F in-repair of pocket type electronics digital TDS meter, complete all as specified and as directed by Engineer-in-charge.
M&L for PCC 1:3:6 type C-2 (40mm graded stone aggregate) as in foundations, fillings and mass concrete with and including providing necessary fromwork, complete all as per specified and as directed by Engineer-in-charge.
M&L for Providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges including necessary formwork, complete all as specified and as directed by Engineer-in-charge.
Dismantling and lowering down of old rusted top plate/roof sheet made out of 3.15mm thick mild sheet from pressed steel water tank on 40 feet staging carefully without making any damage to other members after necessary unscrewing bolts, nuts, etc. complete all as specified and as directed by Engineer-in-charge.
Supply, errection, hoisting and fixing of mild steel top plate/roof sheet 3.15mm thick made to required shape and drilling necessary holes for fixing of bolts & nuts and fixed on existing pressed steel water tank on 40 feet staging including necessary wire mesh jaly as required complete all as specified and as directed by Engineer-in-charge.
Refixing of serviceable top plate obtained from serial item No. 56 after properly cleaning with the help of wire brush complete all as specified and as directed by Engineer-in-charge.
Dismantling and lowering down 5 mm thick pressed steel side plates of size 1.25m x 1.25m from pressed steel water tank on 40 feet staging, carefully without damage to other members after necessary unscrewing of bolts, nuts, washers etc including separating serviceable side plates and kept in safe custody for reuse in the same work complete all as specified and as directed by Engineer-in-charge.
Dismantling and lowering down 6 mm thick pressed steel side plates of size 1.25m x 1.25m from pressed steel water tank on 40 feet staging, carefully without damage to other members after necessary unscrewing of bolts, nuts, washers etc including separating serviceable side plates and kept in safe custody for reuse in the same work complete all as specified and as directed by Engineer-in-charge.
Supply, errection, hoisting and fixing of new pressed steel side plate of 1.25m x 1.25m and 5 mm thick, made to required shape and drilling necessary holes for fixing of bolts and nuts in existing pressed steel water tank on 40 feet staging complete all as specified and as directed by Engineer-in-charge.
Supply, errection, hoisting and fixing of new pressed steel side plate of 1.25m x 1.25m and 6 mm thick, made to required shape and drilling necessary holes for fixing of bolts and nuts in existing pressed steel water tank on 40 feet staging complete all as specified and as directed by Engineer-in-charge.
Fixing only old serviceable pressed steel side plate of size 1.25m x 1.25m obtained from serial item No. 59 here-in-before of 5 mm thickness with nuts, bolts and washers in existing pressed steel water tank after proper cleaning with the help of wire brush on 40 feet staging complete all as specified and as directed by Engineer-in-charge.
Fixing only old serviceable pressed steel side plate of size 1.25m x 1.25m obtained from serial item No. 60 here-in-before of 6 mm thickness with nuts, bolts and washers in existing pressed steel water tank after proper cleaning with the help of wire brush on 40 feet staging complete all as specified and as directed by Engineer-in-charge.
Dismantling and lowering down mild steel tie bar made out of angle iron size 65mm x 65mm x 6mm and 2.00 metre long each from pressed steel water tank on 40 feet staging without any damage to other members with necessary unscrewing of bolts, nuts and washers complete all as specified and as directed by Engineer-in-charge.
Supply, errection, hoisting and fixing mild steel tie bars made out of angle iron of size 65mmx65mmx6mm and 3.00 metre long Each and drilling necessary holes for fixing of bolts & nuts in existing pressed steel water tank on 40 feet staging complete all as specified and as directed by Engineer-in-charge.
Fixing only serviceable tie bars obtained from serial item No 97 above duly cleaned complete all as specified and as directed by Engineer-in-charge.
Supply and fixing mild steel machine made nut and bolt 16-20 mm dia and not exceeding 5 cm long nuts and bolts with washers for fixing of steel plates, tie bars, etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing mild steel machine made nut and bolt 11-15 mm dia and not exceeding 5 cm long nuts and bolts with washers for fixing of steel plates, tie bars, etc. complete all as specified and as directed by Engineer-in-charge.
M&L for fixing leak proof materials comprising of lead wire, glass wool and black putty in existing pressed steel tanks to ensure water tightness after taking out old existing jointing materials by burning with blow lamps and cleaning and jointing surface complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of water level indicator comprising of CI float oval type 250mm dia at centre, MS pulley of 150mm dia, mild steel indicators of suitable size permanently marked stranded stainless steel rope of 10mm dia and 03 m long including connection and accessories required for smooth functioning and testing on completion, complete all as specified and directed by Engineer-in-charge.
M&L for lifting up submersible pump set of capacity upto 30HP including column pipe from borewell and re-lowering the same after replacing damaged gasket, nut-bolts and proper maintenance of borewell and submiersiible pump set, complete all as specified and directed by Engineer-in-charge.
Comprehensive maintenance and general servicing, cleaning, Greasing, Minor repairs to Diesel Engine sets including oil pump, water pump, adjustment of tappets, minor repairs of self starter and dynamo, repair of radiator with cleaning, repair to generator control panel by replacement existing burnt out of copper wire including repair/ replacement of toggle switches and replacement of spares all gasket and joints etc for DG set of capacity 10 to 30 KVA to the entire satisfaction by the Engr-in-Charge. Note : Spare parts will be measured and paid separately under respective items.
All as per serial item No 73 above but for 40 to 75 KVA DG Set complete.
Repair/overhauling /Calibration of fuel injection pump and nozzle with holder assembly of diesel engine including providing new parts such as delivery valves. Elements, tapet gear, plungar , nozzle copper washes, leak off pipes, banzo bolts, service kit, governer repair etc in replacement of existing UNSV Parts including re-assembiling, setting , fixing and testing at site suitable of 10 KVA to 30 KVA DG set.
All as per serial item No 75 above but for 40 to 75 KVA DG Set
Repair / Replacement of safety devices complete unit for DG set (water temperature meter, Hour Meter, oil pressure meter, water temperature sensor, Low pressure sensor, vacuum indicator) (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) for following DG sets :-
(a) 10KVA to 30 KVA
(b) 40 KVA to 75 KVA
Supply and fix in repair of following spares parts against BOQ sl item 72 (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) for 10 to 30 KVA capacity DG Sets :-
(a) Diesel Filter element with clamp and nut-bolt
(b) Mobile Filter element with clamp and nut-bolt
(c) Air Filter element with clamp and nut-bolt
(d) Set of high pressure pipe
(e) Thermostat
(f) Cooling water pipe
(g) set of hoses
(h) set of hose clip
(j) Set of flexible fuel pipe
(k)Set of anti vibration rubber coupling bushes with stud bolts and nuts
(l) Head Gasket
(m) Head Gasket Set
(n) Fly wheel side oil seal
(o) Fly wheel ring gear
(p) STR Relay Board
(r) Controller board (Conservation Kit)
(s) Stop solenoid
(t) Temp Sensor switch
Supply and fix in repair of following spares parts against BOQ sl item 73 (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) for 40 to 75 KVA capacity DG set :-
(a) Diesel Filter element with clamp and nut-bolt
(b) Mobile Filter element with clamp and nut-bolt
(c) Air Filter element with clamp and nut-bolt
(d) Set of high pressure pipe
(e) Thermostat
(f) Cooling water pipe
(g) set of hoses
(h) set of hose clip
(j) Set of flexible fuel pipe
(k) Set of anti vibration rubber coupling bushes with stud bolts and nuts
(l) Head Gasket
(m) Head Gasket Set
(n) Fly wheel side oil seal
(o) Fly wheel ring gear
(p) STR Relay Board
(r) Controller board (Conservation Kit)
(s) Stop solenoid
(t) Temp Sensor
M&L for preparation of old painted body surface of 10 to 30 KVA DG set and applying two coat of synthetic enamel paint as per colour code to the body of DG set and alternator and red colour to the belt guard including writing MES/SM Nos complete all as specified and directed by Engineer-in-Charge. MAKE- Asian Paints/ Berger Paints/ Nerolac Paints/ Shalimar Paints
All as per serial item No 80 above but for 40 to 75 KVA capacity DG Set.
Supply and fix in repair V belt for any drive suitable for DG set capacity 10 to 160 KVA complete all as specified and as directed.
Repairs/replacement to exhaust manifold (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) by replacement of worn out silencer unit of required size and shape suitable for DG set 10 KVA to 30 KVA complete all as specified and directed.
All as per item 83 here in before but suitable for DG set capacity 40 KVA to 75 KVA complete.
Cleaning of fuel tank of any capacity by draining out diesel and cleaning internally with the help of cleaning agent and compressed air , drain out the sludge/foreign matter deposited inside the diesel tank of any capacity of DG set from 10 to 30 KVA capacity
All as per item 85 here in before but suitable for DG set capacity 40 KVA to 75 KVA complete.
Removing existing unserviceble battery and supplied and fixed new lead acid battery maintenance free 12 volts upto 180AH fully charged as required on site with matching capacity of Dg set complete all as directed. (Make- Exide/ Luminious/ as existing)
Taking out old unserviceable battery charger and supply and fix battery charger (MAKE- Exide/ Luminous/ as existing) suitable for charging lead acid battery 6/12volt boost and trickle charging mode, 230 volt single phase complet with charging lead connecting clip complete all as specified and as directed.
M&L for replacement of lubrication oil 20W40, (MAKE- Castrol/ Servo/ Shell) in DG sets of capacity 10 to 160 KVA all as specified and directed.
S&F in-repair of coolent for radiator of water cooled engines as per manufacturers recommendation complete as all directed.
Replacement and Repair of self starter (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) 12 volts for 10 to 30 KVA DG set by replacing the defective worn out parts such as armature, field coil, bendex pinion, clutch plate, solinoid switch and any other necessary parts including testing complete.
All as per serial item No 91 above but for 40 to 75 KVA capacity DG Set.
Taking out radiator assy and repair by cleaning washing flushing and removing blockage of chocked tubes including replacement of existing UNSV water tube soldering nuts bolts washers and making leakproof and testing at site of 10 to 30 KVA DG Set.
All as per serial item No 93 above but for 40 to 75 KVA capacity DG Set.
Taking out old unsv radiator assy and replacement with a new radiator of copper tube material suitable for DG set of capacity upto 75 KVA, complete all as specified and directed.
Replacement of battery copper leads 2 meter long of suitable size single core with copper thimble complete.
Replacement of battery terminals brass of any capacity battery complete.
Repair to alternater complete by dismantling and cutting winding, cleaning, polishing, welding work and re-winding with suitable size and gauge of copper enamelled winding wire complete greasing, replacement of carbon brush, varneshing etc and testing after repair of 10 to 30 KVA DG Set including testing after repair complete all as specified and directed.
All as per serial item No 98 above but for 40 to 75 KVA capacity DG Set complete.
Taking out Dynamo 12 V for complete repair including providing new parts such as armature, brushes, filed coil , bush bearings,cut out, bearing, pully nut, bolts & washer etc in replacement of exisitng UNSV Parts refixing and testing at site of 10 to 30 KVA DG Set.
All as per serial item No 100 above but for 40 to 100 KVA capacity DG Set.
Supply only distilled water for lead acid cell 12 Volt complete.
Supply and replacement of Automatic Voltage Regulator suitable for DG sets of Capacity 10 to 75 KVA.
M & L for repair to AC servo voltage stabilizer by removing burnt out entire copper winding from coils and rewinding of the same coil with super enameled copper wire of appropriate gauge as per original including providing insulation paper, cotton tape, varnishing heating,copper lugs,and nuts and bolts etc and reassembling and testing complete all as specified and directed of capacity 20 KVA to 500 KVA voltage stabilizer
M&L for topping up of transformer oil of dielectric strength more than 50KV in servo voltage stabilizer all as specified and directed.
Disconnecting AC supply,dismantling, taking down and opening Servo stabilizer having capacity 20 KVA to 500KVA. Servicing, repair/replacement unserviceable parts such as contact bush, mechanical tap moving system, filtration of oil, topup new oil, servo motor, carbon busher assembly with carbon and repair/maint/replacement of PC board, indicator, transformer etc and other minor parts found defective during repairing. Re-assembling the same after repairing and commissioning testing, complete all as per specified and as directed by Engineer-in-charge. NOTE :- Parts replaced of voltage stabilizer shall be measured and paid separetly under respective items. (MAKE of spare parts- Havells/ L&T/ Siemens/ as existing)
(a) Replacement of inducator of different colour
(b) Replacement of low cut switch of existing size & capacity
(c) Replacement of high cut switch of existing size & capacity
(d) Repair/replacement R C network suitable size & capacity or as per existing.
(e) Repair/replacement carbon set suitable size & type or as per existing.
(f) Repair/replacement carbon bush suitable size & type or as per existing.
(g) Repair/replacement/rewinding dimmer suitable size & capacity or as per existing.
(h) Repair/replacement/rewinding buckbook transformer suitable size & capacity or as per existing.
(j) Repair/replacement copper lugs of suitable size or as per existing size.
(k) Repair/replacement PCB (printed circuit board) of suitable size & capacity or as per existing.
(l) Repair/replacement PCB connector of suitable size & capacity or as per existing.
(m) Repair/replacement synchronize motor of suitable size & capacity or as per existing.
(n) Repair/replacement triger transformer of suitable size & capacity or as per existing.
(o) Repair/replacement of digital conductor of suitable size & capacity or as per existing.
(p) Repair/replacement digital volt meter.
Dismantling unserviceable turbo charger from DG set of capacity upto 160 KVA complete and supply and fix new turbo charger as per manufacturer's recommendataion all as specified and directed.
S&F in repair Single Phase Contactor Type MR high AC -1 rating all as specified and directed.
S&F in repair relay siutable fo upto 75 KVA DG set/ servo stabilizer all as specified and directed.
Supply and fix Emegency push button for upto 160 KVA DG set all as per manufacturer recommendation and directed by Engr-in-Charge.
M&L for Installation of LED Acrylic alphabet 3D designed glow sign display boards with wiring and led warm lighting for different location under GE Rangia all as specified and directed. (Note:- 1. Acrylic Sign Board IN CAPITAL LETTER (a) 'DARRANGA PUMP HOUSE NO.1'', (b) DARRANGA PUMP HOUSE NO.2, (c) DARRANGA PUMP HOUSE NO.3 (d) KALAKUCHI PUMP HOUSE NO.3 and name of other Pump Houses and Sub station of Tamulpur det and certain unit/stn HQ under GE Rangia as specified and directed by Engr-in-Charge. 2. Name of each installation will be measures as one job. 3. Necessary scafolding for installation of Acrylic sign board including MS post and MS sheet of thickness not less than 4 mm with suitable size will be included in the quoted rate. 4. Size of alphabet shall be not less 25 cm in length/ height all as specified and directed by Engr-in-charge.
Supply and fix in replacement on load change over switch AC-23 (side handle) with advance Neutral switch in steel sheet metal enclosure 4 pole By pass Switch and 415 volts conforming to IS/IEC -60947-3 compact design of capacity 63 Amps complete all as specified and directed. Make: L&T/Legrand / ABB / Siemens / Havells / Schnieder / HPL / Indo-Asia
Supply and fix in replacement on load change over switch AC-23 (side handle) with advance Neutral switch in steel sheet metal enclosure 4 pole By pass Switch and 415 volts conforming to IS/IEC -60947-3 compact design of capacity 100 Amps complete all as specified and directed. Make: L&T/Legrand / ABB / Siemens / Havells / Schnieder / HPL / Indo-Asia
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
M&L for boring holes horizontally under road without damaging the road surface with the help of GI tubing not exc. 80mm bore dia for passing of UG cable, complete all as specified and directed by Engineer-in-charge. NOTE: GI Pipe will be measured and paid separately.
S&F of Galvanised Iron Pipe 50mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed by Engineer-in-charge.
Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 50 Sqmm 3.5 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No. 121 here-in-above, but for cross-sectional area 16 Sqmm 4.0 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of MCCB 4 Pole, 415 Volts, 100 Amps, 50 Hz, conforming to IS/IEC 60898, with Thermal Magnetic release, overload, short circuit fault protection 3 phase, breaking capacity 16 KA, Ics=100% of Icu, with Spreader terminal of both ends, connecting and testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 123 here-in-above, but for 63 Amp capacity MCCB, breaking capacity 16 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of astronomical street light panel of capacity 12 Watt, 3 Phase, contactor rating 65A, TP, MCB rating 63 A TPN conforms to IS/IEC 60947-4-1 provided with protection degree IP 54 with FRLS internal wiring, complete all as specified and directed by Engr-in Charge. Make Havells, Model No. IHXTS0912A. Note :- PCC (1:3:6) foundation for mounting of panel should be 300 mm below the ground level and 450 mm above the ground. cost for fixing angle iron foot frame of size 50x50x5 mm having length 500 mm shall be included in the quoted rate.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth strip of 32x6mm mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 40mm bore( light grade) and watering pipe 20 mm bore GI pipe (medium grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down existing damaged one, complete all as specified & testing on completion. NOTE:- (i) Item includes the cost of 1.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr GI earth wire.
BALEN DEWAN (BID ID -3327832)
OM CONSTRUCTIONS (BID ID -3328175)
M/s Narzary Enterprise (BID ID -3328151)
M/s KRISHNA CONSTRUCTIONS (BID ID -3327959)
G.K. TRADERS (BID ID -3328224)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .