Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC | L1 | Accepted-AOC Being L-1 | |
| 2 | L2₹17.3 L+₹23,985 (1.40%)Rejected-Finance 29 IQBAL COLONY SONWAR SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹17.4 L+₹29,675 (1.74%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹18.0 L+₹86,625 (5.07%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹20.6 L+₹3.5 L (20.4%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
10 Sept 2022, 6:00 pmClosed
GE 864 EWS
GE 864 EWS, BB CANTT SRINAGAR
REPAIR/ REPLACEMENT MAINT OF EARTHING, BLDG SECURITY LIGHT, SUB MAIN WIRING ALONGWITH DBS OF VARIOUS LOCATIONS UNDER AGE E/M OF GE 864 EWS AT BB CANTT, SRINAGAR
2022_MES_525651_2
864/WS-18/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
GE 864 EWS, BB CANTT SRINAGAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹50,000
Yes
11 Oct 2022
20 Aug 2022
12 Sept 2022
20 Aug 2022
10 Sept 2022
27 Aug 2022
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, lamp holders, regulators, switch socket outlets, light fittings etc and making good disturbed surfaces of walls with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and directed.
M&L for point wiring with single runs PVC insulated FRLS grade, 1100V grade cable with multistranded copper conductor of size 1.5 Sqmm (Nominal area) (ISI Marked) drawn in and including PVC Casing capping of suitable size with all fittings and accessories including PVC flush box/ Metal flush box/ sunken box of suitable size and drawing continuous earth wire of PVC insulated FRLS grade, unsheathed stranded copper conductor of size 1.5 Sqmm (ISI Marked) terminated the box for one light point controlled by one, one way swich of point wiring including making good disturbed of wall completed all as specified and directed.
Supply and fix, Switch piano (ISI marked) Single pole 240 volts, flush type, one way 5Amps complete all as specified and directed.
S&F ceiling rose, 3 terminals PVC/ polycarbonate, isolated body complete all as specified and directed.
S&F in repair/ replacement of surface/Recess mounted LED luminaire with complete diffuser 34/ 36W, 2'x2', Flat Panel powder coated CRCA housing, heat sink complete all as specified and directed.
S&F in repair/ replacement of 10/13.5 Watt 6000K LED Bulk head luminaries with premium quality diffuserfor glare free light, etc complete with accessories complete all as specified and directed.
S&F in repair/ replacement of round/ square surface/ recess mounted LED downlighter panel with complete diffuser 15/18W complete all as specified directed.
S&F in repair/ replacement of round/ square surface/ recess mounted LED downlighter panel with complete diffuser 9/12W complete all as specified directed.
S&F in repair / replacement of LED security light of capacity 20 Watt 6000K flood light with IP 65 protection complete all as specified and directed.
S&F in repair /replacement of LED security light of capacity 35/40 Watt 6000K with IP 65 protection complete all as specified and directed.
S&F in repair/ replacement of VTPN distribution board iron clad, double door with IP-43 1K-09 protection suitable for 415 Volts 3 phase 50 C/s 4 way, MCCB as incommer and MCB as outgoing with appropriate size of copper bus bar and neutral link complete with one MCCB 4 pole 415 Volts 100 Amps rating with rupturing cap 16 KA and 12 Nos of MCB SP 63 Amps of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as specified and directed. Make: Cat Part No. 607913 of Legrand or technocommercially equivalent make of L&T / Schenider
S&F in repair MCB Distribution board, 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed.
S&F in repair MCB Distribution board, 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed.
S&F in repair MCCB four pole, 415 Volt, 100 Amps, 16 KA , fixed thermal & magnetic setting complete all as specified and directed.
S&F in repair /replacement of MCCB four pole, 415 Volt, 125 Amps, 16 kA, adjustable thermal & fixed magnetic setting complete all as specified and directed.
S&F in repair MCB SPN, 240 Volts, 40 to 63 Amps, 10 kA rupturing capacity, 'C' series complete all as specified and directed.
S&F in repair MCB SPN, 240 Volts, 32 Amps, 10 kA rupturing capacity, 'C' series complete all as specified and directed.
S&F in repair MCB SP, 240 Volt, 6-32 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed.
S&F in repair MCB SP, 240 Volt, 40 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed.
S&F in repair MCB SP, 240 Volt, 63 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed.
M&L for sub main wiring with two runs of 6.0 Sqmm FRLS grade (ISI marked) PVC insulated, multi stranded, unsheathed copper conductor and one run of, PVC insulated, multistranded FRLS grade (ISI marked) unsheathed copper conductor of size 6.0 Sqmm green colour as earth lead including PVC casing caping of suitable size and taking down old unservicable sub main wiring complete all as specified and directed.
M&L for Sub main wiring with two runs of 10 Sqmm FRLS grade, (ISI marked) PVC insulated, multi stranded, unsheathed, copper conductor and two runs of, PVC insulated multistranded FRLS, grade (ISI marked) unsheathed copper conductor of size 10.0 Sqmm green colour as earth lead including PVC casing capping of suitable size and taking down old unservicable submain wiring complete all as specified and directed.
M&L for Sub main wiring with four runs of 10 Sqmm FRLS grade, (ISI marked) PVC insulated, multi stranded, unsheathed, copper conductor and two runs of, PVC insulated multistranded FRLS, grade (ISI marked) unsheathed copper conductor of size 6.0 Sqmm green colour as earth lead including PVC casing capping of suitable size and taking down old unservicable submain wiring complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, with cover and handle for lifting of cover, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I.
S&F in replacement of Quartz tube of heat pikker 40 Cm complete all as specified and directed.
S&F in replacement of heating element of 750/1000 Watt for heat piller complete all as specified and directed.
S&F in replacement of heat resistance connector strip of cooper tube complete alll as specified and directed.
S&F in replacement of switch block flash set of three 15 Amps complete alll as specified and directed. Make : Gopi or Equivalent.
S&F in replacement of propeller fan with blade 100 mm complete all as specified and directed.
S&F in replacement of Heat resistance connection of copper complete all as specified and directed. Make : Gopi or Equivalent.
S&F in replacement of osillation motor AC 230 volts 90 degree cut complete with base complete all as specified and directed.
S&F in repair 3mm thick hylam brand IS-2036 marked laminated sheet cover complete all as specified and directed.
S&F 6.0 Sqmm 1100 Volts grade, heavy duty PVC insulated multistranded solid aluminium conductor cable and overall PVC sheathed in service connection including taking down old, complete all as specified and directed. Make :- Havells / Plaza / KEI / HPL / Paragon
S&F for 10.0 Sqmm 1100 Volts grade, heavy duty PVC insulated multistranded solid aluminium conductor cable and overall PVC sheathed in service connection including taking down old, complete all as specified and directed. Make :- Havells / Plaza / KEI / HPL / Paragon
M/S TAHIRA ENTERPRISES
M/S Tajamul Ah Buchh
ORISON ENTERPRISES
Alishan Builders
M/S SHIMAR STAR GLACIER
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .