Loading…
Loading…
Tender Value
₹6.9 Cr
EMD Value
₹4.9 L
Closing Date
21 Mar 2025, 11:00 amClosed
S&T work in connection with - Malda Division - Track Machine Sidings - 27 Nos
MLDT_SNT_24-25_26_OT
MLDT_SNT_24-25_26_OT
Open
Works - General
365 Days
Balrampur, Uttar Pradesh
₹0
₹4.9 L
27 Feb 2025
27 Feb 2025
A-Alteration in PI/EI
B-Point Machine
D-Track Circuit
E-Relay Rack, Cable termination Rack, Relays
F-Apparatus Case
G-MACL , Warning Board
J-Trenching & Cable Laying
K-Telecom Items
Item Breakup - A-Alteration in PI/EI
"Modificatio/Alteration (Electronic Interlocking) : Alteration Modificatio/Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines/TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU (Video Display Unit)/ LCP (Local Control Panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards/relays/wiring material/connectors/fuses/communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, interface Circuits, VDU/LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTOCAD, softcopy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied. i) Alteration involving modification in up to 10 routes."
ALTERATION IN EXISTING CONTROL CUM Numbers INDICATION PANEL AND NECESSARY CHANGES & UPGRADATION IN SOFTWARE FOR MAINTENANCE PANEL TO SUIT DESIGN ALTERATION AS PER RAILWAY'S REQUIREMENT WITH PREWIRED TAG BLOCKS, WIRES, MS ANGLE ETC. DEPICTING THE YARD LAYOUT WITH SIGNALS, POINTS, TRACK CIRCUITS, OPERATING/ EMERGENCY PUSH BUTTON, COUNTERS. THIS ITEM INCLUDES WIRING FROM DOMINO TO TAG BLOCK IN THE CONTOL CUM INDICATION PANEL AND TERMINATION OF INDOOR CABLES ON PANEL TAG BLOCKS. THIS INCLUDES SOLDERIG OF WIRES, ON DOMINOS AND TAG BLOCKS AND SUPPLY OF TAG BLOCK ANALYSIS AND SUPPLY OF NECESSARY SCAFFOLDINGS.
Supply of maintainer's furniture of Godrej Set make or superior and each set consist of (i) executive revolving bearing series low back- floating chair with normal arms cushioned chair-01 Nos. (ii) Executive table size 1650x900x728 mm with 3 drawers one side locker- 01 no.(iii) visitor chair seat & back cushion with high density foam with plastic PVC handle capsule type painted back 03 nos.
Supply of Office table with laminated top Numbers with three drawers on left hand side and one locker on the right-hand side. Olive brown with duplicate keys. Make: Godrej Model T-9 (136.5 cmX68cmX75cm) or Similar of reputed brand.
Supply of office chair made up of wood Numbers (Akashmoni/Segun/Sheesham) and as per the specifications mentioned in Annexure - I. Total 9881257.04
Item Breakup - B-Point Machine
Supply of Electric Point machine IRS type Numbers 220 mm throw, high thrust (AC immunity 160V AC), non-trailable to operate on 110V, DC complete with Lock and Detector slides, Cable Termination Box and clamp lock 60 Kg. confirming to IRS: S24/2002 & Assy. Drg. No. RDSO-S/11000 & For Motor IRS: S 37/82. (items to be procured through stores).
Supply of Point JB fitted with 18 nos. 1-way Numbers terminal block confirming to IRS-S-75/91 (AMD-2) OR LATEST, DRG. NO. SA-23741A with 3 no. of 40 mm bore G I PIPE 600 mm long as per DRG. NO. SGW/MGS/ PT4/91 fixed on hylum sheet with U channel (75x40x1500) mm for fixing ARA terminal to be procured from RDSO approved sources.
Supply of Ground Connection [BG] Threaded Numbers Type for IRS type Point Machine, as per CWM/Signal Workshop/Howrah/E.Rly drawing number, Sl.No., Description of Drawing & CWM/SW/HWH's Drawing No. mentioned below :- 1. Detector Rod (Far End) - BS/29/721 with ALT-1 Detector Rod (Near End)- BS/29/722 with ALT-1. 2. Lock Rod (Far End) - BS/29/723 with ALT-1, Lock Rod (Near End) - BS/29/724 with ALT-1. 3. Switch Extension Bracket - BS/29/725 with ALT-1. 4. Drive Rod - BS/29/726 with ALT-1 Drive Lug- BS/29/726 A with ALT- 1. 5. Sleeve- BS/29/726 B with ALT-1. 6. Lug- BS/29/726 C with ALT-1. 7. Pin- BS/29/726 D with ALT-1. 8. Sketch showing the Layout arrangement- BS/29/727 with ALT-1. Amdt. and alt. upto date if any. TURN OUT
Installation of electric point machines (IRS Numbers type 220 mm throw, high thrust/IRS type143 mm throw) on MS plate fixed on wooden/ concrete sleepers complete with fixing of junction boxes, ground connections including smithy works involved, insulation of MS plate on which the point machine is to be fixed from the gauge tie plate involving riveting/welding of angle cleats, installation of point JB, termination adjustment for operation of points by crank handle, painting and lettering as required including wiring, testing and commissioning.Note: MS plate/flat/angle /angle cleats, paints, bolts & nuts and washers of sizes as required for fixing the point machine shall be supplied by the contractor except point machine.
Installation, wiring and testing of electrical Numbers key transmitter for crank handle arrangement, siding control as per yard diagram, approved circuit diagram. Installation portion shall include supply of necessary angles, wooden shelf, nuts & bolts as required for the work. The ward no. Of key shall be advised by the site engineer. This includes supply of electrical key transmitter with key for crank handle interlocking arrangement siding control as per yard diagram, approved circuit diagram and specn.no. IRS-S-21/01(LATEST) AND IRS- S-23(LATEST),DRG.NO.SA-22601 (ADV)ALT.2. [key combination will be intimated by site engineer] Supply Portion MALDA DIVISION-S AND T/EASTERN RLY
Execution Portion (Details as per Sl No. 5 Numbers above)
Dismantling of point machine with ground Numbers connection including point JB.
Dismantling of existing point fittings, drilling Numbers of holes in stock rail/tongue rail/ gauge tie plate, re-rrangement and re-fixing of existing electrical detector and installation of IRS 24/2002 with latest Amdt. point machine on MS plate fixed on wooden/concrete sleepers complete with fixing of point JB ground connections including smithy job for welding &termination & wiring of point machine, adjustment and testing as per technical specification and dismantling of all new fittings excluding point machine and marking with paint for future and transportation up to railway's store. Total 5457163.00
Item Breakup - C-Signal Cable
Supply of Signalling Cable, Size: 12 Kilometre CoreX1.5 sq.mm, Armoured, confirming to RDSO specification No.: IRS:S- 63/2014(Rev.4.0) with latest amendments/version.
Supply of 1 x 16 Sqmm (Red/Black/Green) Metre multi strand copper power wire as per IS:694:2010 or latest, 126 conductor each dia 0.40mm +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.21 ohms/km and test parameters as per RDSO Specn.No.IRS:S- 76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge.
Supply of 1 x 10 Sqmm (Red/Black/Green) Metre multi strand copper power wire as per IS:694:2010 or latest, 140 conductor each dia 0.30mm +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.91 ohms/km and test parameters as per RDSO Specn.No.IRS:S- 76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge.
Supply of 1 x 25 Sqmm (Red/Black) multi Metre strand copper power wire as per IS:694:2010 or latest, 196 conductor each dia 0.40 mm +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 0.78 ohms/km and test parameters as per RDSO Specn.No.IRS:S- 76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge. Total 19778334.40
Item Breakup - D-Track Circuit
Installation commissioning of single rail dc track circuit Circuit (TRACK CIRCUIT BEYOND 200 MTRS.) as per approved track circuiting plan. The work includes track battery charging and installation, fixing of track bonding (double) with 8 SWG soft GI wire, laying of tail cables with track lead junction box, rail connector with galvanized iron wire, track jumpering (double) with supporting arrangement for holding as per track circuit plan. It also includes installation and wiring of track feed chargers, track relays, track circuit equipment's in the location box including fuses and ARA terminals required for the purpose as per DRG NO. SK/ 10/ 95 (NKG) including drilling of 9/32 hole on rails where required. Fixing of track lead junction boxes. Note: - battery charging solution to be supplied by the contractor & double jumpering to be provided.
Installation commissioning of single rail dc track circuit Circuit (SHORT LENGTH TRACK CIRCUIT UPTO 200 MTS.) as per approved track circuiting plan. The work includes track battery charging and installation, fixing of track bonding (double) with 8 SWG soft GI wire, laying of tail cables with track lead junction box, rail connector with galvanised iron wire, track jumpering(double) with supporting arrangement for holding as per track circuit plan. It also includes installation and wiring of track feed chargers, track relays, track circuit equipment's in the location box including fuses and ARA terminals required for the purpose as per DRG NO. SK/10/95(NKG) including drilling of 9/32 hole on rails where required. Fixing of track lead junction boxes. Note: - battery charging solution to be supplied by the contractor & double jumpering to be provided.
Supply of Track Lead Junction Box (TLJB) Numbers made from FRP material including brass bolts and hylum board sheet with terminals etc. The technical specifications are as follows:(a) TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W-212mm and H 90 mm and all the holes required for mounting on FRP stump (vertically two for each FRP angle) HDPE pipe , cable etc.(b) Each TLJB shall have two Bakelite terminal block fitted horizontally : each Bakelite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long. Along with each TLJB , nickel chrome plated brass links(two nos.0f adequate strength for vertical linking of the terminals to be supplied.(c) HDPE pipe of size 32/35mm , 380 mm long along with two nuts for fixing on the TLJB hole .(d) The FRP stump for mounting the TLJB to be made of one meter long 30mm X30mmX 4mm angle(2 nos.) and 300mm long 30mm X30mmX 4mm angle(1 no.) fixed at 50 mm from the bottom using galvanized nuts and bolts. The TLJB and the angles for stump should come along with holes on them for fixing using galvanized nuts and bolts of adequate strength to be supplied along with TLJB MALDA DIVISION-S AND T/EASTERN RLY
"Supply of uncharged Low Maintenance Numbers Lead Acid (LMLA) secondary cell, shelf mounting type conforming to RDSO Specn.No.IRS:S-88/2004 or latest with inter cell connectors, nuts and bolts etc. 2V, 80AH
"Charging of lead acid cell (Secondary cell) Numbers of various capacities as per Manufacturer's/Railway engineer's instruction. Acid and distilled water to be supplied by the contractor. Specific gravity acid should be approved type duly inspected by Consignee. This includes installation and commissioning of battery in circuit. Battery to be kept on wooden rack.. 2V, 80AH
Supply of Track feed Battery Charger as per Numbers RDSO Specn. No.IRS: S-89/2013 Ver.1.0 or latest. Charging Capacity Rating 10 Amps for Charging 80 AH Battery.
Erection, Fitting and Rail connection of Track Numbers Lead Junction Box on two supports (FRP stumps ) with contractor's fixing material .This will include drilling of holes for track lead/side connections on rail. The work shall be done as per instructions of Rly engineer at site.
Supply of Control card for evaluators of Numbers Multi Section DAC along with power supply card or Equivalent.
Supply of Input / Output card for Evaluators Numbers for ""detection Point"" or Equivalent.
"Supply of Input / Output card for Evaluators Numbers for relay driver and final track clearance relay or Equivalent. "
Supply of Double Rail contact assembly with Numbers track side EJB for MSDAC. Each set shall consist of track side Electronic unit, Double rail contact with cable and mounting accessories.
Supply of New Reset Box RB 259A for Numbers HASSDAC asper RDSO Specn. No. RDSO/SPN/177/2012 ver. 3 or latest. Make: CEL.
Supply of New Reset Box RB 259A for Numbers HASSDAC asper RDSO Specn. No. RDSO/SPN/177/2012 ver. 3 or latest. Make: G G Tronics.
"Dual Micro Controller Logic Card No.4 for Numbers HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3 or latest. " Total 19722680.00
Item Breakup - E-Relay Rack, Cable termination Rack, Relays
Installation of cable termination rack with Numbers scaffolding materials ladder for supporting outdoor cable; wire guide complete with other necessary hardware as per requirements of rly. & erection materials. Wires to be procured from RDSO's approved firm only. This includes supply of cable termination rack as per DRG.NO. S&T/C- 17/2001 OR latest with screw less disconnect type connectors ( W a g o / P h o e n i x / S i m i l a r ) , scaffolding materials, ladder for upporting outdoor cable, wire guide, NDT fuse complete with other necessary hardware as per requirements of railway & erection materials. Supply Portion
Execution Portion (Details as per Sl No. 1 Numbers above)
Installation and wiring of relay rack as per Numbers DRG.NO.S&T /C-20/ 2001 with modification vide CSTE/ER'S LETTER NO.SG.42 /9, DT. 15/3/2016. Supply and fixing of fuses with base, diodes; resistances; condensers, terminal strips / tag blocks, bus bars & other equipment's required for the approved system design complete with scaffolding materials & required hardware & erection materials to accommodate 100 relays (station wise quantity to be specified by the tenderer). PVC wire as per RDSO SPEC. IRS- S-76/89, AMD-2 or latest (for wiring of relay rack) shall be supplied by the contractor, duly inspected by RDSO. This includes supply of relay rack to accommodate 100 relays complete with fittings as per DRG.NO. S&T/ C-20/ 2001. Note: - this includes status of relay to be indicated through led indication at the top of relay rack and in this connection all the required materials to be supplied by the contractor. Rack to be fixed on rubber pad. Supply portion
Execution Portion (Details as per Sl No. 3 Numbers above)
Supply of Tag block 200 way/160 way with Numbers PVC covers as per (IRS: S-77/2006 (Rev.1) or latest & Drg.no.SA-24751 & 52. .Requirement of each type shall be specified by Engineer-in-charge. NOTE: In case ABB type relays proposed to be used with 100 way block then Two 100 way Tag Block will be consider as one 200 way Tag Block.
Termination of Outdoor Cables (Main Cables Per /tail cables) at both ends in location boxes, Conductor cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work. MALDA DIVISION-S AND T/EASTERN RLY
Carrying out relay alteration to the existing Per Relay relay wiring at relay rack/location box as per the approved circuit diagram. These work includes the releasing of existing unused wires and wiring the relays using 16/0.2 mm copper wire as per RDSO Spec. Wire to be procured from RDSO's approved source and inspection:by RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh] . Note:- wire to be procured from RDSO's approved source only. All required material like wire, soldering material, paint etc. To be supplied by the contractor for execution of the work Total 979405.00
Item Breakup - F-Apparatus Case
Supply of full size apparatus case (GKP Numbers type) (as per DRAWING NO. SW SK NO. 4/90 & & other applicable GKP SW Drawing).This includes supply of location box (GKP type) with 'E' type lock & key, fitted on location door on both side, E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S- 11500.
Casting, concreting and curing of concrete Numbers foundation, erection and installation of full size apparatus case (GKP type)/Stainless Steel (SS) Apparatus Case as per DRG.NO. S&T/C-6/98(NKG) w ith 'E' type lock on CC foundation. This includes cost of all materials required for fixing holding down bolts, casting, concreting. Note: - bolts, nuts and washers, bitumen compound to be supplied by contractor and bitumen compound to be used in between apparatus case and foundation as per site engineer.This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering.Note: - Location boxes to painted with anti-corrosive paints as per IS:- 9862-1981, one and half feet from the bottom, on all surfaces-both inside and outside.
Fixing by slotted angel, wirring of terminal Numbers strips, Hylam strip, Transformers, Relays, Fuses with base, Fixing of shelves for full size Apparatus case with termination & Earthing of cable/Apparatus case and wirring with lettering as required including supply of slotted angel, wires, ferrules for marking and miscllanious materials per location to be supplied by the contractor. (All materials except transformer, relays, terminal strips, Backelite strips and fuses with base and hard wood shelves to be supplied by the contractor). wires to be used for this purpose should be procured from RDSO's approved firm and to be inspected by RDSO.[Quantity to be specified by the contractor] NB:-Power cables to be terminated with proper lugs and required buss bar and other items to be supplied by the contractor. MALDA DIVISION-S AND T/EASTERN RLY
Supply of hard wood shelves thickness 25 Numbers mm for keeping equipment's and batteries in the location box (FULL or HALF GKP /other type) with suitable varnish and anti-termite chemicals fitted on angles with nuts & bolts. (i) 950 x 400 x 25 MM for full size location box .
Supply of Paper base hylam sheet 12 mm Sqm thick.
Strengthening of foundations of signals, Numbers Full/Half location boxes, by carrying out the earth work around the foundation, ramming of the earth, caring out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank. Total 1531579.75
Item Breakup - G-MACL , Warning Board
Supply of colour light signal post 4.6 mtrs. Numbers and ladder 4.5 mtrs. With bases for ladder and post as per RDSO SPEC. NO. IRS-S-6-81 and DRG. NO. SA-23153/ADV/AIT-1. All drawing should be as per latest.Note: - this includes signal post, base, ladder, ladder base, platform, rail guard & blanking off. Materials to be procured from approved list of firms for manufacturer & supply of mechanical signalling items.
"Supply of color light signal post 3.6 mtr and Numbers ladder 3.5 mtr with bases for ladder & post as per RDSO SPEC. NO. IRS: S-6-81 (or latest) and DRG. NO. SA-23150 (ADV), ALT-1 (OR LATEST). CLS base as per DRG. NO. S- 2011/M (OR LATEST). Note: - this includes signal post, base, ladder, ladder base, platform, rail guard & blanking off. Materials to be procured only from RDSO approved list of firms for manufacture & supply of mechanical signalling items. "
Casting, concreting & curing of foundation Numbers for Main signal including cost of all materials required for casting and concreting. All materials required for execution will be supplied by the contractor including cement, sand & stone chips as per DRG. NO. S&T/C-42(NKG). MALDA DIVISION-S AND T/EASTERN RLY
"Installation, erection and wiring of CLS unit, Numbers post, ladder & base LED unit including paying out of tail cable from location box and earthing of CLS (LED type). This includes supply of non - metallic (FRP) color light signal housing multi-unit type for Rly. Signalling suitable for RE Area 2 Aspect complete without lenses, lamps and signal transformer as per DRG. NO. SA 23001/A/M(ADV), ALT.8 and as per SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP material as RDSO SPEC NO. RDSO/SPN/ 151/1997 OR LATEST. All drawings should be as per latest. Materials to be procured from RDSO's approved firm only. Note: Signal unit should be compatible to 'LED' type. Note: installation, erection & wiring of signalling unit includes LED signal lighting unit including current regulator. This also includes protection of unit from rain water. Supply Portion
Execution Portion (Details as per SL No. 4 Numbers above)
Installation, erection and paying out of tail Numbers cable from location box and wiring of shunt signal, LED unit on the same post below the main signal as per technical specification. This includes supply of position light shunt signal unit without lenses, lamps, base, post and without signal transformer as per RDSO DRG NO. SA-23840/ADV/ALT-2. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note- Signal unit should be compatible to 'LED' type. Supply Portion
Execution Portion (Details as per SL No. 6 Numbers above)
"Supply of cast iron offset bracket for Main Numbers Signal with U clamps, nuts, washers complete DRG. NO.SA-23080/ADV/ALT-1. RDSO SPEC. NO. IRS-S-10/78. Inspection: consignee. Note : Offset bracket has to be connected wherever necessary as per site engineer. "
"Supply of offset bracket for position light Numbers shunt signal (90mm outside Dia.) post with U clamps, nuts, washers complete as per RDSO DRG. NO.SA23080/ADV/ALT-1 all drawings should be as per latest. "
"Casting, foundation for Shunt signal including cost of all materials required for casting and concreting. All materials required for execution will be supplied by the contractor, including holding down galvanized bolts & nuts with washers, cement, sand, stone chips, etc. As per DRG. NO SK/5/95/NKG. "
Installation, erection and paying out of tail Numbers cable from location box and wiring of shunt signal, LED unit as per technical specification. This includes supply of position light shunt signal unit (without lenses, lamps) with Base Post and without signal transformer as per RDSO DRG NO. SA-23840/ADV/ALT-2. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note- Signal unit should be compatible to 'LED' type. Supply Portion MALDA DIVISION-S AND T/EASTERN RLY
Execution Portion (Details as per SL No. 11 Numbers above)
Supply, Fabrication and Fixing of Retro Numbers reflective Nomenclature Board of size 254 mm x 358 mm made of 2mm thick aluminium sheet & high intensity prismatic (hip) grade retro reflective sheet (TYPE -IV) including fixing arrangement for fixing them on existing post per DRG. NO. S&T/SDAH/SK-1386 and as per standard practice.
Supply of various LED signals (Subsidiary Numbers Signal), 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn.No.RDSO/SPN/153/2011 (Rev.4.1) or latest. LED for Shunt Signal aspect
Casting, concreting and curing of foundation Numbers (1:3:6) and erection of SLB/BSLB/SB/WB/Stop board as per DRG. NO S&T/C@47"40@NKG) all materials required for the work including cement, rail post etc. To be supplied by the contractor. This includes supply of SLB/BSLB/SB/WB/ Stop board as per RDSO DRG NO. SA-2375 (ADV.) (WITH LATEST AMDT.) for SLB/BSLB and as per RDSO DRG NO. 7235/B ( WITH LATEST AMDT.) for SB/WB/Stop Board. Supply Portion
Execution Portion (Details as per SL No. 15 Numbers above)
Dismantling including dependent shunt signal, calling on signal if any, fitted on the same post along with signal post, signal unit, ci base without damaging any part. Total 1478228.00
Item Breakup - H-Earthing
Supply of basic material to construct unit Lot maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Necessary testing certificate of UL ,IEC to be produced. It consist of following: (a) Copper bonded steel electrode of 3.0 m long, 17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. © Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate. (minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable
Installation of Unit Maintenance Free Earth Set as supplied in above item.It includes: ( i ) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 micrones to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specs. No RDSO/ SPN/ 197 Ver .1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/ 001 or Latest MALDA DIVISION-S AND T/EASTERN RLY
Supply of earth electrode mild steel Numbers galvanized, light class, IS:1239(PART-I)- 1979.earth electrode pipe should be with 3 mm thick, 50 mm dia and perforated (staggered),5 mm dia holes, 2 nos per 305 mm length with clamp of MS FLAT (galvanised) of size 35 mm x 6 mm (SPEC.NO.226 STD). Earth pipe should include CI threaded cap. Materials to be procured and designed as per CSTE/ER'S DRG.NO.S&T-1/2007.
Supply of MS FLAT (SPEC. NO. 226 STD or Numbers latest) of size 35 mm x 6 mm with length 5 mtr with holes of 12 mm dia at both ends as per CSTE/ER'S DRG. NO. S&T-1/2007 (or latest).
Fixing of earth electrode including laying Numbers and installation of MS flat of size 35 mm x 6 mm with length 5 mtr or as per extant practice of Eastern Railway. As per CSTE/ER'S DRG. NO. S&T 1/2007 for apparatus cases, signal post & other equipment as per instruction of site engineer. Provision for fixing MS flat at apparatus cases/ signal post/other equipment should be made by the firm at site. Full threaded bolts of 10 mm dia and length 40 mm should be welded in the apparatus cases in such way that the MS flat at apparatus case end can be fixed from outside or from inside. Welding rrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. All hardware and other miscellaneous materials required for installation to be supplied by the contractor except earth electrodes and MS flat. Note:-all materials required to be arranged by the contractor except 2 core cable will be supplied by the railway.
Provision of cement concrete enclosure for Numbers earth electrodes as per DRG. NO. S&T/C- 36(NKG). This includes supply of all materials by the contractor Total 739790.00
Item Breakup - I-Relays
Q-Series LED ECR (Universal Type i.e.QECX- Numbers 61), 4F/4B complete with plug board(base plate), connectors, retaining clips etc and conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 ,Amdt.-1and RDSO Specn.No.IRS:S-34 & S-23 with amdt. upto date as applicable or latest.The interlocking code for this unit shall be "ABDHK".
"Contactor Unit (QBCA1 Type), 24 V DC, Numbers 2F(HD)/4B or 2F(HD)2F-4B complete with plug board (base plate), connectors, retaining clips etc. and conforming to BRS- 943 and RDSO Specn.No.IRS:S-34 & S-23 with amdt. upto date as applicable or latest. The interlocking code for this unit shall be ""BCEJK"" or ""DEHJX"". Total 587700.00 MALDA DIVISION-S AND T/EASTERN RLY
Item Breakup - J-Trenching & Cable Laying
Excavation of cable trench as per cable cum route plan, 1.2 Mtr. deep and of 0.3 Mtr. wide at bottom without brick as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1.2m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1.2m. Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4" of 1:2:4 concreting should be done, (b)Payment will be made as per actual work done on pro- rata basis, if required depth is not available at site & (c) if the depth of trench is not uniform in a span of 100 mtr. or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment.
Laying of S&T Cables of various cores/ pairs/ Metre quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on eachcable to give the cable number at each Gantry Post/hectometer post.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. (Here unit Metre means RM)
Digging of trench 1.2 Mtrs. deep from rail cum flange/ road level and 0.3 Mtrs wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, RDSO sketch No. SDO/CABLE LAYING/009 or latest and for Road Crossing, RDSO sketch No. SDO/CABLE LAYING/010 or latest are to be followed. MALDA DIVISION-S AND T/EASTERN RLY
Supply of Double Walled Corrugated (DWC) Numbers HDPE Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 50 mm outer dia, & 38 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring ) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified.
Laying of DWC HDPE duct in trench and its Metre protective work as per direction of site engineer.
Supply of Medium class GI pipes 100 mm Metre dia(4.5 mm thickness) as per IS 1239 ( Part 1 ) : 2004 or Latest with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends.
Laying & Fixing of Medium class GI pipes Metre 100 mm dia(4.5 mm thickness) as per IS 1239 ( Part 1 ) : 2004 with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work(if required) to protect the cables from sharp edges and sudden bends.
Supply of unskilled labour for the various Man-Days signalling gears patch work as per site requirement and under the guidance of Site Engineer. Total 4772642.00
Item Breakup - K-Telecom Items
Supply of SMPS based Battery Chargers as Numbers per RDSO Spec for Telecom use 48 Volts ,25 Amp in 2+1 configuration modules 25 Amp,with ultimate expandable capacity 50Amps , automatic switching between the m o d u l e as per RDSO spec. No. RDSO/SPN/TC/23/1999 version 4 or latest along with two potential free contacts, MALDA DIVISION-S AND T/EASTERN RLY
Installation of of SMPS based Battery Numbers Chargers Power distribution board along with MCBs of suitable ratings and wiring and commissioning of External alarm contacts through EMS . The work includes supply of battery rack , MCBs , battery cable and battery lugs and other accessories required for installation of power plant.
"Supply of Module for SMPS 25 Amps/48VDC Numbers suitable for SMPS base Battery Charger (only for existing Statcon Model No:-SMPS - STATCON 48-25A) as per RDSO spec. No. RDSO/SPN/TC/23/1999 version 4 or latest .
"Supply and installation of SMPS type Numbers battery charger 12 Volt 20 Amperes for VHF setinstalled at Station as per the specificationRDSO/SPN/TC/23/1999 (Ver-4) (Amdt.1) or latest.
Supply of 12V/ 7.5AH SMF Battery | EP7.5- Numbers 12 Battery Series Powersafe Plus Battery Rating 7.5 AH Battery Type: SMF, VRLA ( Sealed Maintenance Free )Nominal Voltage 12 Volts .Make: Exide or similar.
Supply of 25W VHF Radio complete set Numbers forvehicle mounting /Fixed location with built inlogic card to create Unique user ID ,facilitatingDTMF Selective /Group Dialling from the set tomake it compatible to work through Repeaters in VHF communication network including autoscanning facility. Refer technical specification fortechnical parameters. All VHF sets programmingof desired frequency must be done by the tenderer. Specification no.RDSO/SPN/TC/73/2008, Ver.-1.0 or latest.
Installation & Commissioning of VHFsystem Numbers complete with all accessories,programming of frequency and power supply .This work encompasses holistic installation andcommissioning of all ingredients all necessaryfor VHF system functioning in a station- (a) 25WVHF set with proper channel programming (b)Antenna over the self supported Mast (c) powersupply comprising of charger , battery withproper housing . Necessary channelprogramming is to be done by competent OEMEngineer. Necessary arrangements, cables forprogramming is to be provided by contractor.
S u p p l y & installation of LSZH Simplex Numbers armoured Fiber Optic Patch Cord SC - SC, 3 mtr long, make: EVEONET/Syrotech/Digisol/Molex/similar
Supply of Professional AC/DC clamp meter 3 Numbers ¾ digit, true RMS measurement, For Measurement of DC/AC currents up to 1000A, Voltage up to 600V,resistance up to 40 M and frequency up to 1 MHzwith set of leads & carrying case. Model - DCM 39Aor equivalent/ higher make Motwane / Stanlay/Fluke/Megger. Item to be supplied after successfuldemonstration and Approval of Railway. MALDA DIVISION-S AND T/EASTERN RLY
Supply of Digital Multimeter of Fluke 287 Numbers Industrial or Similar/ superior True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000VAC/DC, measure up to 10A, 20A for up to 30 second. Item to be supplied after successfuldemonstration and Approval of Railway.
"Supply of 3.5 digit Backlit LCD Hand Held Numbers True Rms ClampMeter, Make & Model : Metravi(DT-DT-725) or supirior. "
Supply of LAN tester UTP cable tester make Numbers : Prtuthvik Alext/ ULTIMA
Supply of Auto Range Digital Earth Numbers Resistance/GroundResistivity Tester with Time & Date, last Reading recordedwith time & Date. LCD 16X2Digit Display provided withRechargeable NI-MH Cell, withLow Battery indication complete with a set of 4Spikes, 4 Test Leads, Charging Leads & Carrying Case. Resistance/Ground Resistivity Range: 0-2000 Auto Range, Resolution: 0.01. (Accuracy :± 1.0%) . Make: ELECTRONS DEVICES , Model No. DETAutoor Similar.
S u p p l y & installation of of SFP Module Numbers 1Gbps single Mode single Fibre support 20 K m . Make:- DBC ,Rayteckor similar. Inspection: Consignee
"Supply of Optical Power Meter,type-B, as Numbers per TEC spec.GR/OPM-01/03 Feb. 2005 orlatest. "
Supply of Transmission Measuring Set/Kit Numbers along with all accessories as per RDSO Specn. No.IRS: TC- 43/87 or latest. Item to be supplied aftersuccessful demonstration and Approval of Railway.
Supply of Master Cable Fault locatorTest Set Set , Make: MRPC, Model No: ak_mrpc Master or Similar. I) Locate : a) Low Insulation fault. B) Short/Contact Fault c) Earth Fault II) Length range: 25 Km. III) Cable type:HT/LT/Telecom/Signal. Make: Radio Detection/similar, model: Riser Bond 3300/similar, "
Supply of Auto Range Digital Volt DC , Numbers Insulation Range :2/20/200/2000/20000/200000 Meg. , Resolution: 0.001 Meg.(Accuracy ± 1.0% + 3 Digitsupto 1000 Volts & ± 3% + 3Digit for higher Voltage).Make: ELECTRONS DEVICES ,Model No. DIT/M or Similar. Insulation Tester with Time,Date & Test Duration. LCD16X2 Digit Display providedwith Rechargeable NI-MH Cell,with Low Battery indication complete with TestLeads,Charging Leads &Carrying Case. Voltage Range : 100/250/500/1000 MALDA DIVISION-S AND T/EASTERN RLY
Supply maintenanceconsisting of the following item.1) Tool box forcable jointer 1 No.2) Split fire OP kit consistingof a) Universal handle, b) Burner 8 Nos, c) Necktubes 2 Nos, d) Gas hose pipe 2 mtrs, e)Spanner, f) Swivel type regulating valve.3) Gascylinder 2 Kg with Gas, 2 Nos.4) Cutting plair10" Taparia make 1 No.5) Cutter size 6" Tapariamake- 1 No.6) Nose plair 8" Tapariamake - 1No.7) Screw driver set of 6 Nos. Taparia make -1 No.8) Knife 12" - 1 No. No.9) Hacksaw frame -1 Nos.10) Hacksaw blades - 6 Nos.11) Hot chisel12" saw - 2 Nos.12) Adjustable spanner - 2Nos.13) Scissor 15" - 1 No.14) Tin cutter 15" - 1No.15) Ball pin hammer 2 lb - 1 No.16) Ball pihammer 1/2 lb - 1 No.17) File flat smooth - 1No.18) Triangle file smooth - 1 No.19) Steel measuring tape 3 mtrs - 1 No.20) Steelmeasuring tape 30 mtrs - 1 No.21) Solderingiron 65 W - 1 No.22) Soldering iron 25 W - 1No.23) Knife 8" - 1 No. 24) Knife 12"-01 No.
Supply of LAN Extender with high Numbers bandwidth, up to 30MBPS, Model: Mrotek Witelite 4W/similar Make:MROTEK/D- Link/Similar Total 3589825.75
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .