Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L1 | Accepted-AOC ACCEPTTED | |
| 2 | L2₹17.8 L+₹78,440 (4.62%)Rejected-AOC NEW HOSPITAL ROAD UDHAMPUR UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC OTHER THAN L1 | |
| 3 | L3₹19.2 L+₹2.3 L (13.3%)Rejected-AOC PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L3 | Rejected-AOC OTHER THAN L1 | |
| 4 | L4₹19.2 L+₹2.3 L (13.3%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN L1 | |
| 5 | L5₹24.1 L+₹7.2 L (42.1%)Rejected-AOC | L5 | Rejected-AOC OTHER THAN L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
30 Dec 2019, 6:00 pmClosed
SHUBHAM PRAKASH
GE (NORTH) UDHAMPUR
GE/U(N)-60/2019-20 REPAIR/REPLACEMENT OF SUB MAIN WIRING, MAIN DBS EARTHING INCLUDING MCB/MCCB TPN IN CERTAIN ACCN OF CH(NC), AMSD, MUKHERJEE ENCLAVE AND OLD MEDICAL COMPLEX UNDER GE (NORTH) UDHAMPUR
2019_MES_302613_1
GE/U(N)-60/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UDHAMPUR
CLASS E
7 documents required · 7 mandatory
₹500
GE (NORTH) UDHAMPUR
₹40,000
Yes
16 Jan 2020
2 Dec 2019
31 Dec 2019
2 Dec 2019
30 Dec 2019
14 Dec 2019
Amount
Sub main wiring with two run single core 4 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 25 mm dia PVC concealed conduit medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4.0 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc fixed in replacement, complete all as specified and directed by Engr-in-charge. Note: Two runs of 4sqmm and one run of 4.0 sqmm cable and one run of PVC conduit/ casing capping shall be measured as one RM
All as per item No. 1 herein before but with 6 sqmm pvc copper conductor cable through pvc conduit ISI marked with 6 sqmm copper conductor cable as earth contiunity conductor.
All as per item No. 1 herein before but with 10 sqmm pvc copper conductor cable through pvc conduit ISI marked with 10 sqmm copper conductor cable as earth contiunity conductor.
Sub main wiring with two run single core 4 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 25 mm dia PVC surface conduit medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc fixed in replacement, complete all as specified and directed by Engr-in-charge. Note: Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit/ casing capping shall be measured as one RM
All as per item No. 4 herein before but with 6 sqmm pvc copper conductor cable through pvc conduit ISI marked with 6 sqmm copper conductor cable as earth contiunity conductor.
All as per item No. 4 herein before but with 10 sqmm pvc copper conductor cable through pvc conduit ISI marked with 10 sqmm copper conductor cable as earth contiunity conductor.
Sheet metal enclosure distribution board VTPN 4 way 415 volt 100 Amp rated bus bar double door type with suitable for mounting MCCB for incomer and MCBs for outing without MCCB and MCB IP-43 protection fixed in repair, Complete all as directed by Engr-in-Charge. Make:-Legrand cat part No 507745/Indonasian cat part No 811893 or equivalant to Schneider/ Havells.
Sheet metal enclosure distribution board VTPN 6 way 415 volt 100 Amp rated bus bar double door type with suitable for mounting MCCB for incomer and MCBs for outing without MCCB and MCB IP-43 protection fixed in repair, Complete all as directed by Engr-in-Charge. Make:-Legrand cat part No 507746/Indoasian cat part No 811894 or equivalant in Schneider/ Havells.
Sheet metal enclosure distribution board VTPN 8 way 415 volt 100 Amp rated bus bar double door type with suitable for mounting MCCB for incomer and MCBs for outing without MCCB and MCB IP-43 protection fixed in repair, Complete all as directed by Engr-in-Charge. Make:-Legrand cat part No 507754/Indonasian cat part No 811895 or equivalant in Schneider/ Havells.
MCCB 4 pole, 415 volt Adjustable type100 Amps with breaking capacity 16 KA fixed in replacement, complete all as specified and directed by Engr-in-charge. Make:-Legrand or its equivalent in Indoasian/ Schneider/ Havells/C&S
MCCB 4 pole, 415 volt Adjustable160 Amps with breaking capacity 16 KA fixed in replacement, complete all as specified and directed by Engr-in-charge. Make:-Legrand or equivalent in Indoasian/Schneider/Havells/C&S
MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA fixed in replacement, complete all as specified and directed by Engr-in-charge. Make:-Legrand or its equivalent in Indoasian/Schneider/Havells/C&S
MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA fixed in replacement, complete all as specified and directed by Engr-in-charge. Make:-Legrand or its equivalent in Indoasian/Schneider/Havells/C&S
MCB TPN 63 Amp four pole 415V inludung all terminals fitting fixed in replacement, complete all as specified and directed by Engr-in-charge. Make:-Cat part no:408702 of Legrand or its equivalent in Havells/Schneider/Indoasian
LED garnet 18 W NR lamp,4 pin type, 6500K, as per sample fixed in replacement, complete all as specified and directed by Engr-in-charge. Make :Wipro Cat part no-D611865 or equivalent model of Havells/SYSKA/C&S
PVC Casing and capping of 25/12mm inclusive of all elbow,tees etc., fixed in replacement, complete all as specified and directed by Engr-in-charge.
Sheet metal enclosure double door single pole and neutral 240 Volts for DB's when MCBs to be used 8 ways with 200amps rated bus bar with IP-43 protection fixed in repair, complete all as specified and directed by Engr-in-charge Make:- Legrand cat pt No-507611or equivalent of make schneider/Siemens/Indoasian.
All as per item No. 17 herein before but 4way, complete all as specified and directed by Engr-in-charge.
All as per item No. 17 herein before but 12 way, complete all as specified and directed by Engr-in-charge.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one SPN MCB of 20 Amps 240 Volts capacity fixed in repair, complete all as specified and directed by Engr-in-charge.in-charge. Make :Legrand Product code no-607843 or equivalent in Schinder/ABB/C&S.
MCB SP 6 to 32 Amp, 240 volts, 50Hz, C series of breaking capacity 10 KA fixed in replacement, complete all as specified and directed by Engr-in-charge. Make :Legrand Product code no-408587/408590/408592/408593/408594 or equivalent in Schinder/Indoasian.
MCB SP 40 to 63 Amp, 240 volts, 50Hz, C series of breaking capacity 10 KA fixed in replacement, complete all as specified and directed by Engr-in-charge. Make :Legrand Product code no-408596/408597/408598 or equivalent in Schinder/ABB/Indoasian
MCB SPN 40 to 63Amps 'C' series 240V ,50Hz,10kA lighting and other domestic loads incl all termnials, fitting etc. fixed in repair, complete all as specified and directed by Engr-in-charge. Make: Legrand (DX-3) cat no- 408637, 408639 or equivalent of make schneider(Acti-9)/ Siemens(Betagard- 5SL4)/Indoasian.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of 4.00 mm dia GI or steel wire fixed in repair, complete all as specified and directed by Engr-in-charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, fixed in replacement, complete all as specified and directed by Engr-in-charge. Including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
MAHAJAN TRADING CO
DEV RAJ MAGOTRA
HIMALAYA ENTERPRISES
M/S Builders Indias
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .