Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.5 L+₹2.8 L (14.1%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹24.4 L+₹4.7 L (23.6%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹25.8 L+₹6.1 L (30.7%)Rejected-Finance 0 CIVIL LINES TETARI BAZAR TETARI BAZAR NAUGARH SIDDHARTHNAGAR UTTAR PRADESH 272207 | SIDDHARTH NAGAR | UTTAR PRADESH | 272207 | L4 | Rejected-Finance Being L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected not enlisted in cat a(ii) |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
22 May 2021, 6:00 pmClosed
Garrison Engineer (East) Allahabad
Stanley Road, Teliyarganj, Allahabad
Repair and maint of water supply installation, DG set submersible pump, STP and other allied works at Varanasi Cantt.
2021_MES_438188_1
8458/E8
Open Tender
Civil Works
Item Rate
270 days
Varansi
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Allahabad
₹50,000
Yes
30 Jun 2021
23 Apr 2021
28 May 2021
23 Apr 2021
22 May 2021
8 May 2021
23 Apr 2021 - 30 Apr 2021
Amount
Taking out non clog sewage submersible pump including electric motor 20 HP ,3 phase ,415 Volts after disconnecting all electrical , transporting to workshop & machanical connection including dismantling the motor and pump, cutting out the burnt/old/unservecible moulded winding and cleaning the slots with non greasy materials and replacing with moulded copper winding with 'F' class insulation and repair of non clog pump by replacing with and including unserviceable parts such as bearing, bush, impeller mechanical seal suitable for non clog type submersible pump and filling new cooling oil 5 ltrs, reassembling after repair and lowering in the sewage well, reinstalling and testing complete all as specified and directed.
Taking out non clog sewage submersible pump including electric motor 7.5 HP ,3 phase ,415 Volts after disconnecting all electrical , transporting to workshop & machanical connection including dismantling the motor and pump, cutting out the burnt/old/unservecible moulded winding and cleaning the slots with non greasy materials and replacing with moulded copper 'F' class insulation winding and repair of non clog pump by replacing with and including unserviceable parts such as bearing, bush, impeller mechanical seal suitable for non clog type submersible pump and filling new cooling oil 5 ltrs, reassembling after repair and lowering in the sewage well, reinstalling and testing complete all as specified and directed.
M&L for taking out Induction electric motor 7.5 HP ,3 phase ,415 Volts after disconnecting all electrical , transporting to workshop & machanical connection including dismantling the motor, cutting the burnt/old/unservecible winding and cleaning the slots with non greasy materials and replacing with super enamelled copper winding wire of existing guage including repalcement of unserviceable parts such as DE nad NDE bearing, fan blade and reassembling and refixing on the foundation and testing after making all electric connection complete all as specified and directed.
M&L for taking out Induction electric motor 20/25 HP ,3 phase ,415 Volts after disconnecting all electrical , transporting to workshop & machanical connection including dismantling the motor, cutting the burnt/old/unservecible winding and cleaning the slots with non greasy materials and replacing with super enamelled copper winding wire of existing guage including repalcement of unserviceable parts such as DE nad NDE bearing, fan blade and reassembling and refixing on the foundation and testing after making all electric connection complete all as specified and directed.
Taking out centrifugal pump suitable for 7.5/10 HP, 3 phase, 415 Volts after dismantling all the connection and transporting to workshop for repairing pump by replacing with and including unserveciable parts such as both end bearing, bush, impeller, gland packing & gland-I bolts, MS Coupling including love joy coupling (star coupling), water seal and gasket, studs etc and reinstalling in true alignment, making all elect and machenical and testing complete all as specified and directed.
M&L for multi stranded SS wire rope upto 8-10mm dia complete all as specified and directed.
Excavation in post holes (or similar holes) in soft/loose soil each not exceeding 0.5 cum, getting out, watering and making good surface in soft/loose soil complete all specified and directed.
M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in loose/sof soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for clean and dry sand (unwashed) in trenches around the cable for cushioning complete all as specified & directed. Note :- Sand cushioning 8cm before laying the cable and 15cm after laying the cable & punned down 18cm,and punned thickness shall be measured and paid complete all as specified and directed.
Supply and laying dry well burnt locally available brick sub class 'B' old size bricks laid flat with width equal to the length of whole bricks over cable as cable protection complete all as specified and directed.
M&L plain cement concrete 1:2:4, type B-2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete including sub base of under floors complete all as specified and directed.
M&L for plain cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in copings bed plates and the like including weathering, slightly rounded or chamfered angles etc. including necessary form work complete all as specified and directed.
S & F mild steel work as in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161 1979 grade St 240 complete all specified and directed.
Pre- painted galvanised aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with and including self tapping screws complete all as specified and directed.
Plain, Aluminium sheeting of thickness 0.71mm, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified and directed.
S&F cast Iron fittings Bends Tapers. Tee pieces (single & double branch) any type and angle/radius and straight connecting pieces but all ends flanged complete all as specified and directed.
S&F borewell cap suitable for 300mm dia casing pipe made out of MS flat Iron thickness not less than 6mm complete all as specified and directed.
S&F borewell clamp made out of MS flat Iron of thickness not less than 10mm suitable to hold 100 to 150mm dia pipe complete with nut bolt and washer complete all as specified and directed.
M&L for chain pully 3.0 ton capacity with hook and MS Chain of suitable size and length complete all as specified and directed.
Taking out mono block pump including electric motor 2/3.0 HP, 3 phase, 415 Volts after disconnecting the electric connection, transporting to workshop & dismantling the motor & cutting the burnt winding and cleaning the slots with non greasy materials and rewinding with super enameled copper wire (Gauge of copper is to match the existing size) with insulating material, varnishing complete reassembling after repair & reinstalling and making electrical and mechanical connections and testing complete all as specified and directed.
M&L for online chemical dosing pump single phase 230Volts 50 Hzs of cap 1.5 gln to 4.75 glns/hrs suitable for 70 mtr head range for water treatment with FRP tank 100 ltr cap, apoxy coated SS agitator shaft including motor , skid/tank mounted incl pump maint kit, level switch, flow controle valve, cotrole panel and accessories as directed by manufacturer complete all as specified and directed. Make: Fluid system/Pure Aqua/declibac or techno-commercial equivalent as approved by GE
S&F nylon braided heavy duty chlorine gas pipe 10-15mm dia with jublee clip complete all as specified and directed.
S&F modular vent valve chlorine gas pump adaptor model MVH-100 with vaccume tubing and fittings complete all as specified and directed. Make - Aqua/Hydro or techno-commercial equivalent model as approved by GE
Flexible connector manifold & pressurised gas acessories suitable for verical & horizontal manifold with yokes and adaptor of 16 ft length complete all as specified and directed. Make - Aqua/Hydro or techno-commercial equivalent model as approved by GE
S&F excellent reliable & chemical resistant solid machined constructed PVC Injection diffuser and main connetor for gas and liquid injection of size 20mm complete all as specified and directed. Make - Aqua/Hydro or techno-commercial equivalent model as approved by GE
S&F flex connector brass adapter 20mm dia male for chlorine gas complete all as specified and directed. Make - Aqua/Hydro or techno-commercial equivalent model as approved by GE
S&F chemical resistance 20mm MNPT threads universal inlet brass adapter 20mm dia male for chlorine gas complete all as specified and directed. Make - Aqua/Hydro or techno-commercial equivalent model as approved by GE
S&F manifold union 20mm dia NPT for vaccume chlorinator complete all as specified and directed. Make - Aqua/Hydro or techno-commercial equivalent model as approved by GE
S&F in repair fan belt SPB-2410 anti static oil & heat resistant suitable for Air compressor 600 M³/hr including connection complete all as specified and directed.
S&F in repair fan belt B-1465L LP/B56 anti static oil & heat resistant suitable for Air compressor 600 M³/hr including connection complete all as specified and directed.
S&F in repair pressure gauge (water) range 0-4.20 Kg/Sq.cm complete all as specified and directed. Make: AE/KG/Ramco/ Guru/Rajpriya or techno-commercial equivalent model as approved by GE
M&L for Plain or corrugated chequerred steel sheets, any thickness in available sizes, galvanised with grade of Zinc coating 350 including cutting and fixing as per required sizeas complete all as specified and directed.
M&L for taking out air compressor fo Cap 600 cum/hrs of Make Kirloskar and transporting to work for opening head and replacement of liner assembly, rings, gaskets, polishing and alignment of cam /pully drive shaft and replacement of groove key and fixing properly and testing for smooth and vibration free running complete all as specified and directed.
M&L for taking oul old unserviceable compressor oil and filling with new compressor oil upto the required level as recommended by manufacturer complete all as specified and directed.
M&L for excavation in loose/soft soil upto the depth not exc 1.0 mtr along the CI pipe line of dia 80 to 200mm dia between leaking area , burning out the leakage joints refixing the same with proper lead joint and lead wool including necessary returning filling and well ramming in layers n exc 25cm each complete all as specified and directed.
M&L for excavation along the CI/DI/GI pipe line upto 150mm dia between leaking area , and taking out old U/S MS clamp and supply & jointing properly with new clamp/fittings as required including nuts, bolts and rubber packing complete including necessary returning filling and well ramming in layers n exc 25cm each complete all as specified and directed.
M&L Desludging of existing underground sewage collecting sump of 12.0M dia and dept upto 10mtr & getting out sludge by means of sucking supper soucer machine/ and depositing to a distance exceeding 1.5km but n. exc 2km out side MD land at isolated plcaes and painting the internal/external surface of sump with two coats of apoxy cement base paint over a coat of primer including preparing all the surface before painting complete all as specified and directed. Note for Item No 40 to 46- All equipment required or directed by the Engr-in-Charge to clean the sumps shall be arranged by the contractor and rates deemed to be inclusive in the unit quoted rates.
M&L for pumping and desludging of existing sewage bioreactor semi underground sump of size 12mx10m x10m & getting out sludge through sucking supper soucer machine/ and depositing to a distance exceeding 1.5km but n. exc 2km out side MD land at isolated plcaes and painting the internal/external surface of sump with two coats of apoxy cement base paint including preparing all the surface before painting complete all as specified and directed.
M&L Desluding/cleaning of existing slude drying beds of size 5 x 5 m and depth 0.80 by any means ie manually or by mechanical appliances complete by removing the sludge /vegetation from disposing sludge at abandonend place from Cantt area and deposited the same where directed by Engineer-in-Charge including supply & spreading of river washed dry course red sand upto 150 mm thick on top layer of filter bed and painting the walls/channel with two coats of apoxy cement base paint over a coat of primer including preparing the all the surface complete all as specified and directed.
M&L for taking out MBBR media from tank and keeping aside for reuse after cleaning and desluding/dewatering of existing MBBR tank ( four partition) of sewage treatment plant (size 2.5x 2.5 m depth not exceeding 5.0 mtr) by any means ie mechanical appliances complete including working under foul condition and depositing or solid waste (silt) in any proportion and silted soil from the existing tank and removing the sludge to a distance not exceeding 2.0 Km in a sealed container out side of MOD land and painting the internal/external surface of sump with two coats of apoxy cement base paint including preparing all the surface before painting complete all as specified and directed. Note : Pumping out sludge water from Floculator tank by using Diesel engine operated pump and necessary diesel is to be arranged by Contractor & included in unit quoted rates.
M&L for Desluding/dewatering and cleaning with fresh water existing tube settler tank of sewage treatment plant (size 4.0 x 4.0 m and depth not exceeding 5.0 mtr) by any means painting the external and exposed surface of sump with two coats of apoxy cement base paint including preparing all the surface before painting complete all as specified and directed.
Desluding/dewatering and cleaning with fresh water existing chlorine contact tank of sewage treatment plant of size 3m x3mx 3m and painting the external and exposed surface of sump with two coats of apoxy cement base paint over a coat of primer including preparing all the surface before painting complete all as specified and directed. .
Disludging/dewatering of existing TWT tank of sewage treatment plant (Size 6.0mtr Dia and depth not exceeding 8 mtr) and painting the internal/external and exposed surface of sump with two coats of apoxy cement base including preparing all the surface before painting complete all as specified and directed.
Supply and filling aerobic attached growth non clogging randomly moving bed bio reactor MBBR media (fluidised aerobic bed) as per sample chemical resistent suitable for sewage treatment including removing deformed & worn out media complete all as specified & directed. Make - HPPIL/FONTUS or techno-commercial equivalent model as approved by GE
M&L for replacement of 40 mm bore cast iron butter fly valve, including material and labour for joints, replacement of rubber/ fibre joints gasket 2 Nos and nut, bolts , washers in repairs length as per existing butter fly valve complete all as specified and directed. Make:Sant/ Normax or techno-commercial equivalent model as approved by GE.
M&L for replacement of 80 mm bore cast iron butter fly valve, including material and labour for joints, replacement of rubber/ fibre joints gasket 2 Nos and nut, bolts , washers in repairs length as per existing butter fly valve complete all as specified and directed. Make: Sant/Normax or techno-commercial equivalent model as approved by GE.
M&L for preparation of old painted steel surfaces such as angel iron frame, sheets, water filters, pipelines, mild steel ladders, railing, Column pipes any size of STP of any width or girth and painting with one coat synthetic anamel paint (Total surface area 220 sqm approx) complete all as specified and directed.
S&F in repair 100 mm bore sluice valve heavy duty both ends flanged and drilled type nominal pressured rating PN-1, conformed to IS 780 of 1980 complete with cast iron body bonnet wedge stuffing box galvanished thrust plate, spindle made of high tensile stainless steel cast iron hand operated wheel with cap top nuts, bolts. washes wedge nut body seal ring and wedge facing run lead tin braise, compressed fibre bolts and nuts, gland packing of superior quality including 6mm thick rubber gasket joint complete all as specified and directed. MAKE: Upadhyay/ Kirloskar / BIR or techno-commercial equivalent model as approved by GE
S&F in repair 150 mm bore sluice valve heavy duty both ends flanged and drilled type nominal pressured rating PN-1, conformed to IS 780 of 1980 complete with cast iron body bonnet wedge stuffing box galvanished thrust plate, spindle made of high tensile stainless steel cast iron hand operated wheel with cap top nuts, bolts. washes wedge nut body seal ring and wedge facing run lead tin braise, compressed fibre bolts and nuts, gland packing of superior quality including 6mm thick rubber gasket joint complete all as specified and directed. MAKE: Upadhyay/ Kirloskar / BIR or techno-commercial equivalent model as approved by GE
M&L for demolistion of existing valve pit chamber and reconstruction with brick masonary built in cement mortar 1:6 using old size modular burnt brick wall not less that 230mm including coping with PCC 1:2:4 using 20mm graded stone agrregate and angle Iron frame 65x6mm and Opening shutter made out of not less than 4.15mm thick and lifting handle fixed properly with heavy duty MS hinges including plaster of internal and exposed surface using cement mortar 1:6 of internal dimensions 900mmx900mmx900mm complete all as specified and directed.
M&L for demolistion of existing valve pit chamber of internal dimention 1200mmx1200mmx1200mm and reconstruction with brick masonary built in cement mortar 1:4 using old size modular burnt brick wall not less that 230mm including PCC and coping type B2 ( 1:2:4 ) using 20mm graded stone agrregate and angle Iron frame 65x6mm and Opening shutter double door made out of not less than 4.15mm thick MS sheet with lifting handle fixed properly with heavy duty MS hinges and painting with two coat of synthic enamel paint over a coat of red oxide primer on all steel surfaces including 10mm plaster of internal and exposed surface using cement mortar 1:6 of internal dimensions 1200mm x 1200mm x 900mm complete all as specified and directed.
M&L for cable joint with and including jointing kit of submersible cable of size 10 Sqmm to 25 Sqmm 3 core by means of jointing material & making the leak proof jointing complete all as specified and directed.
S & F in replacement , connecting, testing and commissioning fully Automatic Star Delta Starter in sheet steel enclosure type MN 16F with single phase protection suitable for 25HP, 3 Phase, 415 volts, 50 HZ, having all standered accessories complete all as specified and directed. MAKE: Shneider/ L&T/ Legrand/ Standard or techno-commercial equivalent model as approved by GE
S & F in replacement, connecting, testing and commissioning fully Automatic Star Delta Starter in sheet steel enclosure type MN 16F with single phase protection suitable for 10HP, 3 Phase, 415 volts, 50 HZ, having all standered accessories complete all as specified and directed. MAKE: Shneider/ L&T/ Legrand/ Standard or techno-commercial equivalent model as approved by GE
S&F in repair submersible cable heavy duty PVC insulated and sheathed 16 sqmm size 3 core conductor flat fully water proof 1100 volt grade complete all as specified and directed.
S&F in repair submersible cable heavy duty PVC insulated and sheathed 25 sqmm size 3 core conductor flat fully water proof 1100 volt grade complete all as specified and directed.
S&F in repair submersible cable heavy duty PVC insulated and sheathed 10 sqmm size 3 core conductor flat fully water proof 1100 volt grade complete all as specified and directed.
S&F in repair, connect & test EDGE LED street light new generation energy saving & environmental friendly long life versatile pressure die- cast aluminium IP66 LED street light fitting 90 watts on existing street light pole including rusted brackets and 3 core PVC unsheathed copper wire fitting to existing junction box etc, complete all as specified and directed. Make : Bajaj Cat Part No: BRTFG75WLED or techno-commercial equivalent model in Philips/ Crompton/ Havells as approved by GE
S&F in repair, connect & test LED Flood light new generation energy saving & environmental friendly long life versatile pressure die- cast aluminium IP66 90 watts on existing street light pole/OHR including and PVC insulated 4 Sqmm 2 core Aluminium conductor service wire from junction box to fitting and making connection all as specified and directed Make : Cromptan/Havells/Philips or techno-commercial equivalent model as approved by GE.
S&F in replacement Gun-metal gate valve with iron wheel head, screwed both ends for iron pipe of size 20mm bore complete all as specified and directed.
S&F in repair for MCCB, 3 - pole, 415 volts, 200 Amps,breaking capacity 36KA, with thermal magnetic release including taking down old/ unserviceble MCCB complete all as specified and directed. Make - Legrand/ ABB / Shneider or techno-commercial equivalent model as approved by GE.
S&F for GI pipe 20 mm bore 'Light grade' ISI marked including fittings such as bends, tees, sockets etc fixed on wall/pole or laid in trenches under road crossing including taking down existing pipe complete all as specified and directed. NOTE : Excavation, earth work, cushioning & protection work shall be measured & paid separately.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 3.25 M deep below GL with top edge of plate not less than 1.5 M below GL) connected with GI strip 32 x 6mm as earthing lead by means of bolts, nuts, check nuts and washer besides brazing at all joints as shown on drawings and including excavation, earth work, 40mm bore GI pipe light grade ISI marked for protection of GI strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt, PCC 1:3:6, type C-1 chamber and mild steel angle iron frame 40 x 40 x 3 mm and 40 mm thick pre-cast RCC cover (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade ISI marked for watering all as shown in electrical plate No. 3 of SSR Part-I and connected to earth test point including testing including dismantling of old ineffective earthing complete all as specified and directed. (Note:- The rates quoted shall also deemed to include the cost of Earth test point and earth strip and protection pipe upto 7.5 meter beyond the earth plates electrode and the earth resistance of the whole system shall be as near as possible to 0 but shall not in any case exced two ohm.)
M&L for repairing of submersible motor of cap 40 HP ,3 phase ,415 Volts after disconnecting all electrical connection, and transporting the motor to workshop for rewinding with PVC insulated copper conductor ''F' class insulation of existing gauge including cleaning the each slot and providing the insulating material and replacement of bush/bearing and reassembiing after repair complete all as specified and directed
M&L for repairing of multi stage submersible pump (4 stage) suitable for 40 HP ,3 phase ,415 Volts after disconnecting all electrical connections and transporting to workshop for repair and replacement of SS bush/bearing, sleeves, brass/SS impellors, CI body bowls of existing size, thurst plate and reassembiing after repair and making all connection and testing for smooth function without any vibration complete all as specified and directed.
M&L for making all arrangement of tripot stand, chain pully, clamp etc and taking out MS coloumn pipe 100 to 150mm dia including 40 HP submersible pump and motor from borewell upto the depth of 150 mtr and dismantling the rubber gasket flanged joing at the invterval of every 3 mtr and keeping aside the column pipe for reuse and lowering the column pipes, alongwith pump motor including submersible cable duly tied with column pipe with PVC locking strip (min 2 strips at each column) in borewell after cleaning the pipes and making all rubber gasket joints including nuts/bolts/ rubber gasket of approved quality and making all electrical connection and testing complete all as specified and directed.
Supply and lay M S column Pipes heavy grade 3 mtr long flanged ends with all fittings fixed for lowering in bore bell of sizes 100mm bore complete all as specified and directed.
M&L for FASD motor starter prewired suitable for 40 HP, 3 phase, 415 Volts with suitable relay of 415 Volts, ML-4 contactors, electronic timer switch, single phase preventor, complete all as specified and directed. Make: L&T, Seimens/Schinder or techno-commercial equivalent model as approved by GE.
M&L for LED type phase indicator lamp (RYB) complete all as specified and directed.
M&L for three phase 415 Volts heavy duty power improvement capacitor bank 10 KVAr complete all as specified and directed. Make: L&T/Havells/ Apcos or techno-commercial equivalent model as approved by GE
Disconnecting and stopping of incoming and outgoing pipes by means of hessian cloth to avoid choking of distribution pipe lines, removing complete water from the over head tank, cleaning internal wall of tank by brooming and steel wire brush and removing completely settled dirt/sand/silt and flushing the complete tank through wash out pipes, cleaning and preparing all rising, delivery, wash out, over flow pipes and sluice valves of any size ,and painting with one coat synthetic enamel paint with different color code/shades as directed including preparing/scrapping and painting RCC OH tank external surface of tank with one coat of apoxy cement base paint including writing down date of cleaning, capacity of tank with syntheic enamel paint with suitable size letter as directed by engineer in charge, and senitising all the internal surfaces of tank by spreying bleaching powder (grade-I) solution with pressure gun machine in ratio 100 Kg/1000 ltrs before water filling the tank complete for 60,000 Gallon capacity (21 mtr staging) OH tank complete all as specified & directed.
All as per item No 75 above but for 50,000 Gallon capacity (21 mtr staging) OH tank complete all as specified & directed. Note for Ser Item No 75 & 76 (i) Necessary scaffolding/safety equipmnet required for painting of OH tank shall be provided by the contractor and rates deemed including unit quoted rate. (ii) All safety precausion shall be strictly adhered and damages if any shall be born by contractor during execution. Contractor will ensured that laboures appointed for painting of OH tank/ cleaning of sewage sumps will be life ensured. Unit quoted rate shall be deemed including for above aspects and not any claim entertained by the deptt at any stage.
M&L for repair to electronic digital water level indicator including replacement of SS wire rope and floating ball as reqired and all accessories suitable measuring height upto 10 mtrs and making all electricl connection and testing at site complete all as specified and directed.
Supply and laying or fixing or passing through pipe, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 4 core complete all as specified and directed.
Supply and laying or fixing or passing through pipe, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm 3.5 core complete all as specified and directed.
S&F in replacement of push button red/green, complete all as specified and directed. Make : Esbee or techno-commercial equivalent model as approved by GE
Supply and fix best quality gland packing 6 to 12 sq mm dia of make Champion to stop leaking in Pump Houses/sluive valve in field area complete all as specified and directed.
Material and labour for premium quality crush and kink resistance garden PVC flexible water pipe 20mm dia in 30 mtr roll complete all as specified and directed. Make - Fortune or techno-commercial equivalent model as approved by GE
M&L for cleaning of water supply, OHR tanks, valve pit chambers and sewage installations area and cutting grass and removing weeds/herbs from its roots and deposting where complete all as specified and directed.
Supply, Fix in repairs three phase 230 V DOL starter suitable for for 1.5/2 HP HP pumpset with overload and short circuit protection complete all as specified and directed. Make: Schneider / L&T or techno-commercial equivalent model as approved by GE.
Supply, Fix in repairs three phase 415 V DOL starter suitable for 5/7.5 HP pumpset with overload and short circuit protection complete all as specified and directed. Make: Schneider / L&T or techno-commercial equivalent model as approved by GE.
Supply, Fix and connect 3 Pole Power Contactor having AC3 Rating 80 Amps with 2 NO + 2 NC Auxilliary Contacts complete all as specified and directed. Make: Schneider / L&T or techno-commercial equivalent model as approved by GE, including taking down old unservieable.
S&F relay 3 phase 415 V MNF of range 29-42 suitable for 40 HP starter complete all as specified and directed.
Supply & Fix, Star coupling (R-150) , Heavy Duty, Styrene Butadiene Rubber suitable for coupling of 10/15 HP pump and motor, including taking down old unservieable.
Supply and fixing rubber packing cotton braided not less than 3.0 mm thick any size complete all as specified and directed.
M&L for heavy duty MS coupling suitable for 50mm dia shaft with key groove and including MS key of suitable size complete all as specified and directed.
Supply and fix lead pig grade-I and culkering/cocking run lead joint to stop leakages in any type/size of CI/DI pipe line complete all as specified and directed.
Supply and fix carbon steel nut bolts/washers/ foundation bolts of any size complete all as specified and directed. Make - TVS/Unbreako or techno-commercial equivalent model as approved by GE.
M&L for repair/servicing of 40 to 125 KVA diesel enginer generator set installed at pump house including repalcement of old unserviceable part as required and trasporting to workshop for any repair work complete all as specified and directed. Note - Spare part shall be measured and paid separately under respective item only.
Taking out old unserviceable self starter of DG Set 40 to 125 KVA of Make Kirloskar and trasporting to workshop for repairing of self starte including replacement of field coil/stator coil and rotor/bush as required and fixing testing after repair work complete all as specified and directed.
Supply and replace fuel pipe of required size as per site requirement complete all as specified and directed.
Taking out old unserviceable fuel pump of DG Set 40 to 125 KVA of Make Kirloskar and transporting to authorised workshop for calibration and replacement of 'O' ring and unsv parts as required and refixing and testing the same after repair work complete all as specified and directed.
M&L for drain out the fuel tank and taking out for cleaning/ servicing /welding and refixing duly painted with two coats of synthetic anamel paint on external surface after preparing complete all as specified and directed.
M&L for replacement of fuel filter primary/secondary of DG Set 40 to 125 KVA as required make/size complete all as specified and directed. Make : Kirloskar or techno-commercial equivalent model as approved by GE.
M&L for replacement of Oil filter of DG set 40 to 125 KVA as required make/size complete all as specified and directed. Make: Kirloskar or techno-commercial equivalent model as approved by GE.
Supply and replace exhaust manifold lether gasket as required for DG set 40 to 125 KVA complete all as specified and directed.
Supply and replace Engine oil 20W30 complete all as specified and directed. Make: Gulf oil or techno-commercial equivalent model as approved by GE.
Supply and replace coolent complete all as specified and directed. Make - Indian Oil or techno-commercial equivalent model as approved by GE.
M&L for taking out old unservice radiator assembly of DG set 40 to 125 KVA and transporting to authorised workshop for cleaning/de scaling and repair work of soldering/brazing as required including replacement of lid and gasket and refixing the same at site complete all as specified and directed.
Supply and replace air filter oil bath type suitable for 40 to 62.5 KVA DG Set complete all as specified and directed. Make - Kirloskar or techno-commercial equivalent model as approved by GE.
Supply and replace air filter paper impregrated type suitable for 40 to 125 KVA complete all as specified and directed. Make - Kirlosakar or techno-commercial equivalent model as approved by GE.
Supply and replace old unserviceable led acid batter of cap 12V, 100 AH complete all as specified and directed. Make : Exide or techno-commercial equivalent model as approved by GE.
S&F 10 Sqmm copper conductor battery lead with brass battery terminal and lug of size 450mm long complete all as specified and directed.
S&F Ignition switch as required complete all as specified and directed.
M&L opening the engine head and taking out the unserviceable block and liner assembly of DG set 40 to 62.5 KVA make Kirloskar and transporting to workshop/authorise dealer for replacement of piston block, rings and liner assembly including replacement of all gasket and testing commission complete all as specified and directed.
M&L opening the engine head and taking out the unserviceable block and liner assembly of DG set 15/20 KVA make Kirloskar and transporting to workshop/authorise dealer for replacement of piston block, rings and liner assembly including replacement of all gasket and testing commission complete all as specified and directed.
M&L for replacement of fuel filter primary/secondary of DG Set 15/20KVA as required make/size complete all as specified and directed. Make: Kirloskar oor techno-commercial equivalent model as approved by GE.
M&L for replacement of Oil filter of DG set 15/20 KVA as required make/size complete all as specified and directed. Make: Kirloskar or techno-commercial equivalent model as approved by GE.
S&F carbon brush set of DG set 15/20 KVA mae Kirloskar complete all as specified and directed.
M&L for taking out old unserviceable three phase 415V alternator 32 KW and transporting to the workshop for repair and rewinding with super enamelled copper conductor of exising guage and refixing the same and testing commission all as required at site.
M&L change over switch three phase 415 Volts 200A capacity front operating rotary handle inlcluding fixing and making all electrical connections with 10Sqmm single core copper conductor wire with proper lugs complete all as specified and directed.
S&F for high quality long lasting UV stablised corroson/ crack resistance with dimond/square 2-12mm hole shape, grean color weather proof polyproplene PVC coated mesh fencing including 2nd class teak wood batten frame duly tightened with wooden patti and nails and fixing on all top opening/air vent of over head reservoir of size not exceeding 2x1m at a height not exceeding 25 mtr to prevent entry of birds/dirty particles complete all as specified and directed
RVRconstructon
M/s Deeksha construction
PANDEY TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .