| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAdmitted-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | ₹2.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.7 Cr+₹5.0 L (1.90%)Admitted-Finance | ₹2.7 Cr+₹5.0 L (1.90%) | L2 | Admitted-Finance |
| 3 | L3₹2.8 Cr+₹19.4 L (7.37%)Admitted-Finance | ₹2.8 Cr+₹19.4 L (7.37%) | L3 | Admitted-Finance |
| 4 | L4₹2.9 Cr+₹30.2 L (11.5%)Admitted-Finance | ₹2.9 Cr+₹30.2 L (11.5%) | L4 | Admitted-Finance |
| 5 | L5₹3.0 Cr+₹39.0 L (14.8%)Admitted-Finance B 4 KALKA GARHI HANS PLAZA AMBEDKAR ROAD VILLAGE TOWN GHAZIABAD CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201001 INDIA | GHAZIABAD | UTTAR PRADESH | 201001 | ₹3.0 Cr+₹39.0 L (14.8%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | V.K.sam Engineering L1 | MEPF INFRA L6 | ESSENN Power Controls PVT LTD L3 | VISHAL TECHNOPOWER PVT. LTD. L5 | C R ELECTRICALS L2 | N.K.INDUSTRAL SERVICES L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling the existing old L.T cubicle
distribution board at TH Colony 11KV
Substation including unwanted cables
from the cable trench and reconnect the old
working in good condition cables and new
cables to new LT panel, Existing old street
light cables removed from the earth level to
junction box at street light post and keep
in the opening of pit and closing/refilling,
Damaged and unserviceable cables shall be
shifted and handed over to CH.P.A. RSA
yard. as per Schedule ‘A’. | 1 | No. | 29,400 ₹29,400 | 15,000 ₹15,000 Lowest | 20,000 ₹20,000 | 25,000 ₹25,000 | 30,000 ₹30,000 | 44,800 ₹44,800 |
| 2.00 | Dismantling the existing old L.T panels and Wall mounted boards from various Electrical rooms of No.4,9,10,18,DLB (West).CISF MESS, CH.P.A Hr. Sec. School and Corporation School same shall be shifted, loading, transporting, Unloading and handed over to RSA Yard as per Schedule ‘A’. | 8 | No. | 4,900 ₹39,200 | 1,000 ₹8,000 Lowest | 5,000 ₹40,000 | 5,000 ₹40,000 | 5,000 ₹40,000 | 8,400 ₹67,200 |
| 3.00 | Removing of existing damaged street light
foundation and newly strengthening of
foundation to M.S. street light posts by
using of M 20 concrete for 3 feet a
foundation measurement 450 mm X 450
mm in square shape in build to provide the
2 mtrs. suitable size HDPE hose for cable
entering. (foundation 1 feet below ground
level and 2 feet above the street light post). | 70 | No. | 5,880 ₹4,11,600 | 1,500 ₹1,05,000 Lowest | 3,500 ₹2,45,000 | 4,500 ₹3,15,000 | 6,000 ₹4,20,000 | 4,480 ₹3,13,600 |
| 4.00 | Dismantling the existing old and damaged
Feeder pillars at various location and same
shall be shifted, loading, Transporting,
Unloading and handed over to RSA Yard as
per Schedule ‘A’. | 16 | No. | 2,940 ₹47,040 | 2,000 ₹32,000 Lowest | 3,500 ₹56,000 | 2,500 ₹40,000 | 4,000 ₹64,000 | 5,376 ₹86,016 |
| 5.00 | Supply of 3½ Core x 300 Sq.mm.
XLPE, L.T, UG, Alu. armoured cable with
cable route marker from 11KV Sub-station
to Electrical switching rooms in various
locations as detailed in Schedule ‘A’. | 1,430 | Mtrs | 1,483 ₹21,20,690 | 1,639 ₹23,43,770 | 1,725 ₹24,66,750 | 1,610.51 ₹23,03,029.3 | 1,392 ₹19,90,560 Lowest | 1,624 ₹23,22,320 |
| 6.00 | Laying of 3½ Core x 300 Sq.mm.
XLPE, L.T, UG, Alu. armoured cable with
cable route marker from 11KV Sub-station
to Electrical switching rooms in various
locations as detailed in Schedule ‘A’. | 1,430 | Mtrs | 88 ₹1,25,840 | 100 ₹1,43,000 | 70 ₹1,00,100 Lowest | 130 ₹1,85,900 | 80 ₹1,14,400 | 168 ₹2,40,240 |
| 7.00 | Supply of 3½ Corex185 Sq.mm.
XLPE, L.T, UG, Alu. armoured cable with
cable route marker from 11 KV Substation
to Electrical switching rooms in various
location and Electrical switching room to
feeder pillar boxes in various locations as
detailed in Schedule ‘A’. | 4,650 | Mtrs | 960 ₹44,64,000 | 1,080 ₹50,22,000 | 1,110 ₹51,61,500 | 1,042.17 ₹48,46,104.45 | 901 ₹41,89,650 Lowest | 1,053 ₹48,96,450 |
| 8.00 | Laying of 3½ Corex185 Sq.mm.
XLPE, L.T, UG, Alu. armoured cable with
cable route marker from 11 KV Substation
to Electrical switching rooms in various
location and Electrical switching room to
feeder pillar boxes in various locations as
detailed in Schedule ‘A’. | 4,650 | Mtrs | 74 ₹3,44,100 | 80 ₹3,72,000 | 60 ₹2,79,000 Lowest | 110 ₹5,11,500 | 65 ₹3,02,250 | 134 ₹6,23,100 |
| 9.00 | Supply of 3½ Core x 50 Sq.mm. XLPE, L.T, UG, Alu. armoured cable from Electrical switching rooms and Feeder Pillar Boxes to Individual Residential Blocks in various location as detailed in Schedule ‘A’. | 6,650 | Mtrs | 299 ₹19,88,350 | 366 ₹24,33,900 | 330 ₹21,94,500 | 325.03 ₹21,61,450.83 | 281 ₹18,68,650 Lowest | 330 ₹21,94,500 |
| 10.00 | Laying of 3½ Core x 50 Sq.mm. XLPE, L.T, UG, Alu. armoured cable from Electrical switching rooms and Feeder Pillar Boxes to Individual Residential Blocks in various location as detailed in Schedule ‘A’. | 6,650 | Mtrs | 59 ₹3,92,350 | 60 ₹3,99,000 | 40 ₹2,66,000 Lowest | 55 ₹3,65,750 | 65 ₹4,32,250 | 90 ₹5,98,500 |
Tender Value
₹3.0 Cr
EMD Value
₹6.1 L
Closing Date
10 Feb 2026, 2:30 pmClosed
The Chief Mechanical Engineer
7th Floor Centenary Building No 1Rajaji Salai,Chennai 600 001
SUPPLY AND LAYING OF LT CABLES FROM 11 KV SUB STATION TO ELECTRICAL ROOMS ELECTRICAL ROOMS TO FEEDER PILLAR BOXES FEEDER PILLAR BOXES TO RESIDENTIAL BLOCKS AND ELECTRICAL ROOMS TO STREET LIGHT POSTS SUPPLY AND INSTALLATION OF LT PANEL AND FEEDER
2026_ChPT_893465_2
MEE/01/2026/Dy.CME(Works)
Open Tender
Electrical Works
Works
Chennai
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹6.1 L
Yes
5 May 2026
3 Feb 2026
11 Feb 2026
4 Feb 2026
10 Feb 2026
4 Feb 2026
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_942646.xls
BOQ • 0.36 MB
t.pdf
Tender Documents • 1.14 MB
cor.pdf
Additional Documents • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .