Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 LAccepted-AOC | L1 | Accepted-AOC Award of Contract | |
| 2 | L2₹41.2 L+₹1.3 L (3.16%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹41.3 L+₹1.3 L (3.31%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹41.7 L+₹1.7 L (4.32%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹41.9 L+₹1.9 L (4.69%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest |
| Sl No | Description | Qty | Unit | R. T. Saluji L4 | Maruti Abhiyantriki L2 | Ms. S.K. ASSOCIATES L6 | M/s. Sagar Traders L5 | KAMINS CARE L1 | BHAVIN INFRA L3 | vedant engineering enterprises L5 | M/s Renuka Enterprises L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Comprehensive Maintenance of D.G sets, periodical servicing including first hand repairs, consisting of normal repair such as tightening of nut bolts, greasing, checking/ replacing of battery terminals, levelling of distilled, water, cleaning of main battery charging alternator where ever exists, replacement of defective/ worn out spares such as diesel filters, rubbers hose pipe, fuel pipe and change of oil and cleaning of radiators etc.
Note :- (a) The maintenance cost of D. G set for month shall deemed to comprise of cost of labour employed for the purpose.
(b) All spares and oil replaced will be measured & paid under relevant items of Schedule 'A'.
(c) Fixing charges for the spares and oil etc, are deemed to be included in quoted rates. | - | - | - | - | - | - | - | - | - | - |
| 1.01 | (i) 320 KVA | 9 | Each job | 1,790 ₹16,110 | 1,500 ₹13,500 Lowest | 1,876 ₹16,884 | 1,870 ₹16,830 | 1,790 ₹16,110 | 1,815 ₹16,335 | 1,870 ₹16,830 | 1,850 ₹16,650 |
| 1.02 | (ii) 160 KVA | 9 | Each job | 1,550 ₹13,950 | 1,400 ₹12,600 Lowest | 1,576 ₹14,184 | 1,490 ₹13,410 | 1,490 ₹13,410 | 1,515 ₹13,635 | 1,490 ₹13,410 | 1,550 ₹13,950 |
| 1.03 | (iii) 100 KVA/110 KVA/125 KVA | 88 | Each job | 1,200 ₹1,05,600 | 1,100 ₹96,800 Lowest | 1,100 ₹96,800 Lowest | 1,145 ₹1,00,760 | 1,140 ₹1,00,320 | 1,115 ₹98,120 | 1,145 ₹1,00,760 | 1,100 ₹96,800 Lowest |
| 1.04 | (iv) 62.5 KVA/ 63 KVA | 63 | Each job | 1,050 ₹66,150 | 1,000 ₹63,000 | 1,076 ₹67,788 | 980 ₹61,740 Lowest | 990 ₹62,370 | 1,015 ₹63,945 | 980 ₹61,740 Lowest | 1,000 ₹63,000 |
| 1.05 | (v) 40 KVA | 63 | Each job | 800 ₹50,400 | 700 ₹44,100 Lowest | 746 ₹46,998 | 770 ₹48,510 | 745 ₹46,935 | 715 ₹45,045 | 770 ₹48,510 | 800 ₹50,400 |
| 1.06 | (vi) 25 KVA/ 20 KVA | 63 | Each job | 650 ₹40,950 | 650 ₹40,950 | 576 ₹36,288 | 645 ₹40,635 | 595 ₹37,485 | 575 ₹36,225 | 645 ₹40,635 | 550 ₹34,650 Lowest |
| 1.07 | (vii) 18.75 KVA/ 15 KVA | 54 | Each job | 550 ₹29,700 | 500 ₹27,000 Lowest | 550 ₹29,700 | 545 ₹29,430 | 500 ₹27,000 Lowest | 515 ₹27,810 | 545 ₹29,430 | 500 ₹27,000 Lowest |
| 1.08 | (viii) 7.5 KVA | 18 | Each job | 550 ₹9,900 | 500 ₹9,000 | 500 ₹9,000 | 570 ₹10,260 | 500 ₹9,000 | 515 ₹9,270 | 570 ₹10,260 | 450 ₹8,100 Lowest |
| 1.09 | (viii) 200 KVA | 9 | Each job | 1,600 ₹14,400 | 1,350 ₹12,150 Lowest | 1,476 ₹13,284 | 1,570 ₹14,130 | 1,500 ₹13,500 | 1,475 ₹13,275 | 1,570 ₹14,130 | 1,450 ₹13,050 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
24 Jul 2025, 6:00 pmClosed
Garrison Engineer (North) Ahilyanagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahilyanagar Fort Ahilyanagar 414 002
REPAIR/ MAINT OF DG SETS, VOLTAGE STABILIZER, CRANES, SERVICES OF INCINERATORS, WASHING MACHINES, AIR COMPRESSOR, LIGHTNING ARRESTERS, EARTHING IN ELECTRICAL INSTALLATION AND ALLIED ITEMS AT ACC AND S UNDER GE(N) AHILYANAGAR.
2025_MES_712823_2
8983/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
Garrison Engineer (North) Ahilyanagar
Class D Cat b(i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer (North) Ahilyanagar
₹90,000
Yes
15 Oct 2025
10 Jul 2025
26 Jul 2025
10 Jul 2025
24 Jul 2025
17 Jul 2025
Amount
Comprehensive Maintenance of D.G sets, periodical servicing including first hand repairs, consisting of normal repair such as tightening of nut bolts, greasing, checking/ replacing of battery terminals, levelling of distilled, water, cleaning of main battery charging alternator where ever exists, replacement of defective/ worn out spares such as diesel filters, rubbers hose pipe, fuel pipe and change of oil and cleaning of radiators etc. Note :- (a) The maintenance cost of D. G set for month shall deemed to comprise of cost of labour employed for the purpose. (b) All spares and oil replaced will be measured & paid under relevant items of Schedule 'A'. (c) Fixing charges for the spares and oil etc, are deemed to be included in quoted rates.
(ii) 160 KVA
(iii) 100 KVA/110 KVA/125 KVA
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA
(viii) 200 KVA
Taking down defective self-starter 12/24 Volt of D. G. set of capacity 100 KVA to 320 KVA D. G set installed at various installations & servicing / overhauling including replacing worn out part like solenoid, bearing, carbon brush, rewinding the starter motor winding etc. & refitting the same after repair for smooth functioning in all respect.
.-ditto- all as per Ser Item No 2 above but 15 KVA to 63 KVA
M&L for cleaning the fuel tank both internally & Externally by removing all the dust / sediments etc. including writing of tank capacity, Date of cleaning for followings.
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA
Supply and fix in replacement of Diesel fiiter with 'O' Ring suitable for following capacity of D. G. sets as per sample :-
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 10 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA
Supply and fix in replacement of Air filter element suitable for following capacity of D. G. sets as per sample :-
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 11 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
Supply and fix in replacement of oil filter element with 'O' Ring suitable following capacity of D.G. sets as per sample :-
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 10 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA
Supply & fix in repair in replacement of set of belts suitable for following capacity of D. G. sets as per existing at site. Note : Each set included dynamo belt, Fan belt and water pump belt.
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 10 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA
M & L for replacement of set of Rubber Hose for water & Air circuit complete suitable for D. G. sets of following Capacities:-
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 10 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA
Scrapping / cleaing the existing paint completely and painting with two coats of anti corrosion synthetic enamal paint with spray painting colour as to be followed) D. G. set (Internal & External), fuel tank etc. Note : Colour code as per existing colour including removing all stricker/rediam fixing new strickre as per existing
(ii) 160 KVA/200 KVA
(iii) 100 KVA/110 KVA/125 KVA (Total 10 Nos)
(iv) 62.5 KVA/ 63 KVA
(vi) 25 KVA/ 20 KVA
(vii) 18.75 KVA/ 15 KVA
(viii) 7.5 KVA
M & L for removing the fuel injection pump from D. G set capacity 100 to 320 KVA and carry out servicing & calibration from authorised service workshop including replacement of injectors, Nozzles etc. and refitting the same for smooth and efficient functioning all as directed by Engr-in-Charge.
.-ditt- all as per Ser Item No 11 above but for 40 to 63 KVA
.-ditt- all as per Ser Item No 11 above but for 7.5KVA to 25 KVA
M&L for replacement of stater switch of DG set of capacity 63 to 320 KVA complete all as speciifed and directed
M&L for repair to radiator by disconnecting the radiator from engine frame and servicing / cleaning with acid and brazing where required to stop leaking tubes/joints etc. cleaning fins and re-fixing the same for D.G. set given below.
(i) 100 KVA to 320 KVA
(ii) 40 KVA to 63 KVA
(iii) 7.5 KVA to 25 KVA
M & L for repair of turbo charge by replacing repair kit & fixing same on D. G set 40 KVA to 320 KVA
Taking down the defective water pump fram DG Set & replacement with new one for D. G. set of following capacities complete all as all directed by Engr-in-Charge.
(b) 200 KVA/160 KVA
(d) 40 KVA to 63 KVA
(e) 7.5 KVA to 25 KVA
M & L for replacement of Engine Oil, 15W-40 complete all as specified and dierected
M & L for replacement of Coolant for Engine
M & L for replacement of Electrolyte of suitable spigravity for lead Acid batterries
M & L for replacement in distil water for battery
M & L for replacement of fuel pipe steel braided with Benzo bolt & washer etc. of lenth 30 cm
M & L for replacement of fuel pipe steel braided with Benzo bolt & washer etc. of lenth 60 cm
M & L for replacement of fuel pipe steel braided with Benzo bolt & washer etc. of lenth 100 cm
Taking down the defective coupling at Exhaust mainfold end & Supply and fix new flexible coupling stainless steel as per sample.
Taking down the existing perished/damaged asbestos rope and supply & replace with new asbestos rope 10 mm thick on the exhaust pipe including covering with complete all as directed.
Supply & fix in replacement of automatic voltage regulator 100 to 125 KVA D. G. set complete all as specified and directed.
Supply & fix in replacement of automatic voltage regulator 160 to 200 KVA D. G. set complete all as specified and directed.
Supply & fix in replacement of automatic voltage requlator 320 KVA D. G. set complete all as specified and directed.
Supply & fix in replacement of automatic voltage regulator 20 to 63 KVA D. G. set complete all as specified and directed.
Supply battery leads set, PVC insulated multi stranded copper 70 sq mm of 1.25 meter long each duly fixed with brass clamps.
M & L for replacement of brans battery terminal suitable for lead acid, battery 12 v any AH
Supply & fixing in replacement digital ammeter 0 to 300 Amps
Supply & fixing in replacement digital Voltmeter 0 to 500 Amps
Supply & Fixing Engine Oil pressure gauge meter up to 7 kg complete all as specified and directed
Supply & Fixing in replacement of Engine water temp. meter complete all as specified and directed.
Supply and fix in repairs change over switch existing panel, wall or LT pole of any size and any type off load type, triple pole and neutral, 100 Amps, 415 V, 50 Hz side handle operated, including connecting and testing all as directed.
.-ditto- all as per ser item No 37 above but off load type, 125A side handle operated, including connected accssories complete all as specified and directed
.-ditto- all as per ser item No 38 above but off load type, 200A side handle operated.
M & L For welding / brazing of silencer pipe of of DG Set
M&L for replacement of Door Hinges of various capacity of DG Set complete all as specified and directed.
M&L for replacement of Door lock of various capacity of DG Set as per existing at site of any capacity of adg set
S&F in replacement of Contractor MNX 225 2 No + 2 NC ,3 pole power contractor current rating AC 3 :225 Amp,AC1 :300 Amp or as per existing at site of capacity of DG set 100 to 160 KVA
S&F in replacement of MCCB 250 Amps, three pole, 25 KA complete all asspecified and directed by Enge in charge
S&F in replacement of Indicator lamp of colour (red,yellow,green) of DG set panel of any capacvity of DG set including all connecting circuit.
Labour only for perodical maintenance, brake down on call repairs of EOT Crane 2 Ton long travel motor, cross travel motor, gear box, control panel etc. installed at Armoured Static Work Shop including dismaintling/ replacing the unserviceable spair parts at site complete all as specified and directed. Note:- Rate includes greesing, cleaning, oiling etc.
.-ditto- all as per ser Item No 46 above but 2.5 Tons.
.-ditto- all as per ser Item No 46 above but 3.5 Ton.
.-ditto- all as per ser Item No 46 above but 10 Tons.
.-ditto- all as per ser Item No 46 above but 25 Tons.
Note For Item No 47 to 50 (a) Maintenance of cranes required to be done in every month which includes cleaning, greasing, , oiling, which ever required, checking of all electrical connections and standard maintenance as recommended by manufacturer. (b) Spare Parts replaced, Oil, Lubricants (except Grease) required will be measured and paid separately. (c) Load test carried out in the presence of Engineer-in-Charge and users on every month after periodical maintenance (d) contractor should attend day to day complaint of crane regularly and maintenance shall be carried out accordingly for smooth functioning and the cost for the same shall be deemed to be included in the above quoted rates.
M&L in replacement of following spare parts suitable for EOT Crane of capacity of 2.0 ton to 25 Ton.
(a) Wheel with pin shaft
(b) Ball bearing (Bearing No-6207)
(c ) MS Gear for wheel
(d) Steel wire rope multi stranded 10mm, Make Usha Martin
(e ) PVC Coated & PVC Insulated copper conductor multistranded of size 10 sqmm 4 core
(f) HRC fuse link 32 amps as per site requirement
(g) Gear box Oil EP -230
(h) Brake Oil DOT4/3
(j) Brake Shoe of 150mm dia
(k) Magnetic Coil
(l) Limit switch 3 phase 415 volt 50 Hz as per site requirement
(m) Four Pole Contactor Ac Three phase 415volt Amps as per Site requirement
(n)copper Carbon brushes for clutch for microw movement of EOT Crane
(o) Current collector complete as per existing for EOT Crane of different capacity of EOT Crane
(p) crane slider ACSR dog conductor wire rope used as a bus bar
M&L for replacemnt of complete wiring of crane sliding panel and control panel using copper cable by using proper protective cover and necessary accessories of suitable size as per existing at site complete all as specified
M&L for taking down Gearbox assembly of 2 ton to 25 ton capacity of Crane for long travel mechanism, short travel mechanism, updown mechanism, refixing the same after over hauling completely by replacing Gear oil C-600, Gasket set, bushing etc all as directed. Note: Gear Oil is paid separately and gasket set, bushing etc include the quoted rates.
Taking down and Material and labour for rewinding of electric motor 2HP/415, 3HP/415volt and 5HP/415 volt by using SE Copper wire same gauge and same turns incl varnishing heating, balancing etc from short travel/ long travel mechanism and refixing the same by replacing bearing, varnishing etc all as directed by Engineer-in-Charge.
Taking down and Material for rewinding of electric motor 10HP/415 volt by using SE Copper wire same gauge and same turns incl varnishing heating, balancing etc from short travel/ long travel mechanism and refixing the same by replacing bearing, varnishing etc all as directed by Engineer-in-Charge.
M&L for repairing to long travel shaft by replacing pedstal bearing 06 Nos, including machining work replacing nut, bolts, washers all as directed by Engineer-in-Charge. Note:- Rate of Pedastal Bearing is included in quated rate.
M&L for repair to brake system completely by replacing brake shoe, rotor, brake liner, spring for long travel, short travel, updown mechanism all as directed by Engineer-in-charge. Note:- Break shoes is measured and Paid Separately
Repairs to guide wheel 4 Nos for long Travels by replacing gun metal filling, reboring and machine work with in tolerance limit all as specified and directed.
M&L for periodical maint of oil fired incinerator of Make : HAAT Model GD-3once in three month which includes the following works.
(a) Descalling of Gap between greads
(b) Descalling of combution Chamber
(c ) Descalling of arch chamber
(d) Descalling of stack arrester.
(e ) Overhauling burner nozzel blast tube pump, diffuser etc
(f) Cleaning of Diesel tank and fuel lines
Note:- (i) Rate Includes for painting on Diesel Tank and writing in White Paint Date of Cleaning and capacity. (ii) contractor should attend day day complaint of Incenarator regularly and maintenance shall be carried out accordingly for smooth functioning and the cost for the same shall be deemed to be included in the above quoted rates.(iii) Parts are measured and Paid separately.
Supply and fix in replacement of following Parts for Incenarator :-
(a) Ignition electrode, Cat Part No-HTT09/83
(b) Ignition Transformer 200-6000Volt, Cat Part No-HTT09/83
(c) Diffuser plate, Cat Part No-HTT06/83
(d) Solenoid Valve Cat Part No-VAL 0029/5
(e) Fuel Pump Assembly Cat Part No-HT001/9
(f) Fuel Suction Filter assembly, Cat Part No-HA2/3
(g) Combution Blower Cat No-HTT 11/83
(h) Solenoid coil for combution blower, Cat Part No-VA-0320/9
(j) Sequence Controller, Cat Part No-HTT 22/G3
M&L for periodical maint of washing machine and Dryer DER-30 and Dryer Thumbler once in three month which includes the following works.
(a) Descalling of drying chamber by descalling solution MAC
(b) Oiling , Greasing of bearing of moters and shaft
(c ) Laying and tighting of panel wiring with proper thimbles/ PVC Clampr.
(d) Overhauling of washing machine Chamber
Note:- (i) Rate Includes for writing in White Paint Date of Cleaning and capacity. (ii) contractor should attend day day complaint of Machine regularly and maintenance shall be carried out accordingly for smooth functioning and the cost for the same shall be deemed to be included in the above quoted rates.(iII) Parts are measured and Paid separately.
Supply and fix in repair of washing machine of following Parts :-
a) V Belt size A-69
b) HRC Fuse up to 32 Amps
d) Hose pipe for Drain 1.2 Mtr Length
e) Water Solinied Valve 1''
f) Conatctor 3 Phase 63 Amps for starter of main drive moter
g) Heating Contactor
j) Electric heater
k) Idler Shaft
l) sequence Controler
m) ignition Transformer
n) Air Filter Cum Regulator
O) Single Phase Prevainter
p) Drying Thumbler timer
q) Tension Spring
r) Breaking contactor
g) Display meter
h) Tub ball bearing washing machine
i) Motorised drain valve
M & L for rewinding of 3 Phase universal electric motor including varnishing of washing machine main drive 3 HP incl taking down and reinstalling at site incl connecting electric point and commissioning complete al as specified.
M & L for periodical maint of Voltage stabilizer/ UPS of capacity upto 125 KVA once in three month which includes the following works. (i) check SVS working in auto mode (ii) Check battery terminals and clean (iii) Check input and output connection (iv) check Battery voltage (v) Cech control card (vi) Check Driver card (vii) Check IGBT (viii) Check charger card
Supply and fix in repair voltage stabilizer/ups of following Parts :-
a) Control card for voltage stabilizer/ups as per existing at site of capacity 10/25 KVA
b) Control card for voltage stabilizer/ups as per existing at site of capacity 100/125 KVA
c) Driver card for stabilizer/ups as per existing at site
d) IGBT for stablizer
e) Charger card
M&L for Overhauling of voltage stabilizer complete by using spares part from OEM of capacity 125/ 100 KVA complete including dismtalling, removing the damagable/ unsv parts and reassembling, testing and commissioning the same complete all as specified and directed. Note : Spares parts will measured and paid by separately
a) S&F in replacement of Varic 40 Amps, single phase, 3 nos as per existing at site
b) S&F in replacement of Buck boost 100 Amps, single phase for charging 12/24V service battery
c) S&F in replacement of Motor 10 kg /cm AC synchronous servo motor, RPM 60. for construction of voltage as per existing at site
d) S&F in replacement of control card for 125/100 KVA voltage stabiliser or existing as per site
e) S&F in replacement of contractor for 100/125 KVA stabiliser of existing capacity
f) S&F in gear assembly for 100/125 KVA stabilizer as per existing at site
M&L for Overhauling of voltage stabilizer complete by using spares part from OEM of capacity 10/25 KVA complete including dismentalling, removing the damagable/ unsv parts and reassembling, testing and commissioning the same complete all as specified and directed. Note : Spares parts will measured and paid by separately
a) S&F in replacement of Varic 8/12 Amps, single phase, 3 nos as per existing at site
b) S&F in replacement of Buck boost 40 Amps, single phase for charging 12/24V service battery
c) S&F in replacement of Motor 3 kg /cm AC synchronous servo motor for construction of voltage as per existing at site
d) S&F in replacement of control card for 10/25 KVA voltage stabiliser or existing as per site
e) S&F in replacement of contractor for 10/25 KVA stabiliser of existing capacity
f) S&F in gear assembly for 10/25 KVA stabilizer as per existing at site
M&L for periodical maint of Air Compressor once in three month which includes the following works. (03 Nos of Air Compressor)
(a) Checking the compressed air pipe for leakage.
(b) Checking of V belt and repair and replacement.
(c) Oil, Greasing of bearing of moters and shaft
(d) Checking of pressure valve switch for automatic control of compressor.
(e) Checking of non return valve of compressor and if damage repair it.
f) Overhauling of compressor moter
(g) Tighting and cheking of panelwiring with proper thimble
(h) Painting of Air compressor with with synthetic enamel paint, one coat after cleaning scrubing the surfaces incl wrirting by paint the capacity, marking of fuel level indicator etc complete as directed by Engineer in charge.
Note:- (i) Rate Includes for writing in White Paint Date of Cleaning and capacity. (ii) Contractor should attend day to day complaint of Machine regularly and maintenance shall be carried out accordingly for smooth functioning and the cost for the same shall be deemed to be include in the above quoted rates.(iII) Parts are measured and Paid separately.
Supply and fix in repair following Parts for air compressor :-
a) V Belt suitable for Air compressor to motermain drive Pully
b) Compressed Air Pipe of 10mm Dia of Heavy Duty
c) Head Gas Ket
d) Piston Ring
e) Connecting Rod
f) Oil Seal
S&F DOL Starter of Air Compressor moter Main Drive 3 HP Incl taking down and reinstalling with new starter 415 volt 50 cycle current rating 8 Amps incl connecting to electric point and commissioning etc complete all as directed.
M&L for repair of AMF panel 160 KVA DG set by using following Parts :-
(a) AMF Controller
(b) Contactor 4 Pole 415 Volt 225 Amp, Make: L&T/Seimens
(c) Bty Charger 24 Volt 20 Amp
(d) Digital multifunctional meter for freq, Amp, Voltage, KWH
(f) Voltage Monitoring relay
M & L for periodical maint of car washing point once in three month which includes the following works. (03 Nos of car washer motor)
(a) Checking the motor in regular basis.
(b) winding of motor
Note:- (i) contractor should attend day to day complaint of Machine regularly and maintenance shall be carried out accordingly for smooth functioning and the cost for the same shall be deemed to be include in the above quoted rates.(iII) Parts are measured and Paid separately.
M&L for replacement of unserviceable battery 12 V, 88 AH with maintenance free battery 12 Volt initially charged. Make - Exide
M&L for replacement of unserviceable battery 12 V, 180 AH with maintenance free battery 12 Volt initially charged. Make - Exide
Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 63 Amps, with breaking capacity 16 KA , fixed type including spreaders and connecting accessories etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 100 Amps, with breaking capacity 25 KA, fixed type including spreaders of suitable size and connecting accessories etc complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to copper strip 20 x 3 mm, by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed. Note:- i) Cost of GI strip 20 x 3 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted. ii) Excavation and returning filling of Soil any type is deemed to be included in rates.
Shifting of DG set of any capacity from one place to another place within cantt area including dismantling of existing connection carefully and lifting ,transporting with the help of crane and necessary transport and reassembling at new place including,reconnection same including testing with complete connection complete all as specified and directed etc
Supply and fixing in replacement of Solenoid switch as per existing at site for DG set of capacity 63 KVA to 100 KVA with complete manufacture connection and necessary items required etc all as speified and directed .
Supply and fixing in replacement of Solenoid switch as per existing at site for DG set of capacity 125KVA to 320 KVA with complete manufacture connection and necessary items required etc all as speified and directed .
Supply and fixing in replacement of LLOP as per existing at site for DG set of capacity 63 KVA to 200 KVA with complete manufacture connection and necessary items required etc all as speified and directed .
M&L for Overhauling of DG set complete by using spares part from OEM of capacity 25/40 KVA complete including dismentalling, removing the damagable/ unsv parts and reassembling, testing and commissioning the same complete all as specified and directed. Note : Spares parts will measured and paid by separately
(a) S & F in replacement of Cylinder liner Assly complete all as specified and directed
( b) S & F in replacement of Pistion + Ring Assly complete all as specified and directed
(c) S&F in replacement of Set of Joints complete all as specified and directed
(d ) S&F replacement of Cylinder Head Gasket set of complete suitable for 25/40 KVA DG set complete all as specified and directed.
(e) M&L for Lub Oil Cooler complete all as specified and directed
(f) S&F in repalcement of Con Rod Bearing complete all as specified and directed
(g) S&F in replacement of Main Bearing set complete all as specified and directed.
(h) S&F in replacement of Lub oil pump complete all as specified and directed.
(i) S&F in replacement to Cam Bush set complete all as specified and directed.
(j) S&F in replacement to Cylinder Head Rep By Replacing inlet & Ex Valve complete all as specified and directed.
(k) S&F in replacement of Oil seal set complete all as specified and directed.
(l) S&F in repair/ replacement to Water pump Assly complete all as specified and directed
(m) S&F in replacement to Chamber Gasket complete all as specified and directed.
(n) S&F in replacement of Water pipe set all as specified and directed.
M & L for Overhauling of DG set complete by using spares part from OEM of capacity 63 KVA complete including dismantling, removing the damagable/ unsv parts and reassembling, testing and commissioning the same complete all as specified and directed. Note : Spares parts will measured and paid by separately
(a) S & F in replacement of Cylinder liner Assly complete all as specified and directed
(b) S&F in replacement of Pistion + Ring Assly complete all as specified and directed
(c) S&F in replacement of Set of Joints complete all as specified and direcetd.
(d ) S&F replacement of Cylinder Head Gasket set of complete suitable for 63 KVA DG set complete all as specified and directed.
(e) M&L for Lub Oil Cooler complete all as specified and directed
(f) S&F in repalcement of Con Rod Bearing complete all as specified and directed
(g) S&F in replacement of Main Bearing set complete all as specified and directed.
(h) S&F in replacement of Lub oil pump complete all as specified and directed.
(i) S&F in replacement to Cam Bush set complete all as specified and directed.
(j) S&F in replacement to Cylinder Head Rep By Replacing inlet & Ex Valve complete all as specified and directed.
(k) S&F in replacement of Oil seal set complete all as specified and directed.
(l) S&F in repair/ replacement to Water pump Assly complete all as specified and directed
(m) S&F in replacement to Chamber Gasket complete all as specified and directed.
(n) S&F in replacement of Water pipe set all as specified and directed.
M&L for Overhauling of DG set colplete from OEM of capacity 125 KVA complete including dismantling, removing the damagable/ unsv parts and reassembling, testing and commissioning the same complete all as specified and directed. Note : Spares parts paid and measured by separately
(a) S&F in replacement of Cylinder liner Assly complete all as specified and directed
(b) S&F in replacement of Pistion and Ring Assly complete all as specified and directed
(c) S&F in replacement of Set of Joints complete allas specified and direcetd
(d ) S&F replacement of Cylinder Head Gasket set of complete suitable for 125 KVA DG set complete all as specified and directed.
(e) M&L for Lub Oil Cooler complete all as specified and directed
(f) S&F in repalcement of Con Rod Bearing complete all as specified and directed
(g) S&F in replacement of Main Bearing set complete all as specified and directed.
(h) S&F in replacement of Lub oil pump complete all as specified and directed.
(i) S&F in replacement to Cam Bush set complete all as specified and directed.
(j) S&F in replacement to Cylinder Head Rep By Replacing inlet & Ex Valve complete all as specified and directed.
(k) S&F in replacement of Oil seal set complete all as specified and directed.
(l) S&F in repair/ replacement to Water pump Assly complete all as specified and directed
(m) S&F in replacement to Chamber Gasket complete all as specified and directed.
(n) S&F in replacement of Water pipe set all as specified and directed.
M&L for Overhauling of DG set colplete from OEM of capacity 160 KVA complete including dismantling, removing the damagable/unsv parts and reassembling, testing and commissioning the same complete all as specified and directed. Note : Spares parts paid and measured by separately
(a) S&F in replacement of Cylinder liner Assly complete all as specified and directed
(b) S&F in replacement of Pistion and Ring Assly complete all as specified and directed
(c) S&F in replacement of Set of Joints complete allas specified and direcetd
(d) S&F replacement of Cylinder Head Gasket set of complete suitable for 25/40 KVA DG set complete all as specified and directed.
(e) M&L for Lub Oil Cooler complete all as specified and directed
(f) S&F in repalcement of Con Rod Bearing complete all as specified and directed
(g) S&F in replacement of Main Bearing set complete all as specified and directed.
(h) S&F in replacement of Lub oil pump complete all as specified and directed.
(i) S&F in replacement to Cam Bush set complete all as specified and directed.
(j) S&F in replacement to Cylinder Head Rep By Replacing inlet & Ex Valve complete all as specified and directed.
(k) S&F in replacement of Oil seal set complete all as specified and directed.
(l) S&F in repair/ replacement to Water pump Assly complete all as specified and directed
(m) S&F in replacement to Chamber Gasket complete all as specified and directed.
(n) S&F in replacement of Water pipe set all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard dense soil etc complete all as specified and directed by Engineer-in-Charge
M & L for cement concrete type C2 (1:4:8)) using 20 mm graded stone aggregate in foundations, filling as mass concrete etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair 50 x 50 x 6 mm thick angle iron frame flat iron 40 x6 mm cut to length including drilling holes for fixing of nut and bolts to hold chain link fencing including painting with two coats of synthetic enamel paint over one coat of red oxide primer on all exposed surface complete all as specified and directed.
Supply and Fixing in repair of chain link fencing including line wires, any mesh, size dia 4 mm thick and steel wire mesh aperture 50 mm of standards, rails, straining bolts, etc.including provission of binding wire fixing 10 mm dia mild steel round bar to tighten chain link fencing including necessary hooking binding cutting etc complete all as specified and directed by Engineer-in-Charge
Supply and spreading in electrical outdoor installation yard, stone aggregate of size 20 mm Near DP structures after through cleaning, anti grass treatment etc all as specified and directed.
M & L for aluminium cable lugs of size upto 50 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point as directed. (Note-To be measured only, fixed at places other than with heat shrink joints) Make - Dowells or equivalent.
M & L for aluminium cable lugs of size upto 70, 95, 120, 150, 185, 240, 300 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point as directed. Make - Dowells or equivalent.
Supply and laying of bricks surrounding the stone aggregate at sub station including necessary excavation,returning and removing complete all as specified and directed.
M & L for reparing of Starter including rewinding of armature and replacement of field coil,commutator including carbun brush and overhauling complete all as specified and directed.
M&L for reparing of Alternator of existing capacity DG set including regulator, rectifier, rotor slip, rings and end bearing stator winding,drive end bearing and pully complete all as specifiedd and directed.
Repir/ Replacement of Alternator of capacity 320 KVA DG set by transporting to wksp and after repair fixing the same with proper alingment. Reapir work will carry following items complete all specified and directed.
a) Rewinding of Main Stater
b) Rewinding of Main Roter
c) Rewinding of Auxillary stater
c) Rewinding of Auxillary Roter
e) Bearing 2 Nos
Repir/ Replacement of Alternator of capacity 160 to 200 KVA DG set by transporting to wksp and after repair fixing the same with proper alingment. Reapir work will carry following items complete all specified and directed.
a) Rewinding of Main Stater
b) Rewinding of Main Roter
c) Rewinding of Auxillary stater
d) Rewinding of Auxillary Roter
e) Bearing 2 Nos
Repair/ Replacement of Alternator of capacity 63 to 100 KVA DG set by transporting to wksp and after repair fixing the same with proper alingment. Reapir work will carry following items complete all specified and directed.
a) Rewinding of Main Stater
b) Rewinding of Main Roter
c) Rewinding of Auxillary stater
d) Rewinding of Auxillary Roter
e) Bearing 2 Nos
M & L for fabrication of bus bar chamber of (size 500 x 500 x300 mm) suitable for 415 volts 3 phase 4 wire system , outdoor type, double door, provision space for one MCCB, with pedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 60 cm above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge Comprising of 4 nos. Aluminium bus bar 100 Amp for phases & 50 Amp for neutral mounted on DMC/ porcelain insulator support complete all as specified and directed.Note: All MCCB Shall be Thermal and Magnetic adjustable type as per IEC 6047-II
M & L for fabrication of bus bar chamber of (size 500 x 500 x300 mm) suitable for 415 volts 3 phase 4 wire system , outdoor type, double door, provision space for one MCCB, with pedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 60 cm above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge Comprising of 4 nos. Aluminium bus bar 200 Amp for phases & 50 Amp for neutral mounted on DMC/ porcelain insulator support complete all as specified and directed.Note: All MCCB Shall be Thermal and Magnetic adjustable type as per IEC 6047-II
Supply and fixing Air filter housing for DG set of capacity upto 100 kva including all fixing accessories and connected item complete all as specified and directed.
Supply and fixing Air filter housing for DG set of capacity upto 100 kva to 200 kva including all fixing accessories and connected item complete all as specified and directed.
Supply & Fixing and testing of LT cable 1100 volts grade, XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) ISI Marked with aluminium conductor suitable for earthed system of size 95 sq mm 3.5 core in trenches, on poles and in ducts complete all as specified and directed by Engr in charge. Note:- Excavation and Earthwork, Cable protection shall be measured and paid seprately under the relevent item of this BOQ.
Excavation in trenches nexc 1.5 mtr in depth and not exceeding 1.5 Mtr wide for laying of cable/pipe etc and getting out in any type of soil complete all as specified nad directed.
Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm thick each layer as in soil complete all as specified nad directed.
Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified nad directed.
Supply & laying of HDPE (DWC) pipe ISI mark of outer dia 63 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends etc complete all as specified and directed by Engineer-in-Charge. Make : Supreme / Infra / Astral/Prince/jain irrigation
Maruti Abhiyantriki (BID ID -3368243)
BHAVIN INFRA (BID ID -3369580)
R. T. Saluji (BID ID -3365344)
M/s. Sagar Traders (BID ID -3369208)
vedant engineering enterprises (BID ID -3369220)
Ms. S.K. ASSOCIATES (BID ID -3369037)
M/s Renuka Enterprises (BID ID -3368253)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .