Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 and most Reasonable | |
| 2 | L2₹9.0 L+₹99,120.60 (12.4%)Rejected-Finance H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹9.1 L+₹1.1 L (13.3%)Rejected-Finance | L3 | Rejected-Finance Being Not L1 | |
| 4 | L4₹9.2 L+₹1.2 L (15.3%)Rejected-Finance 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Being Not L1 | |
| 5 | L5₹9.5 L+₹1.5 L (18.3%)Rejected-Finance VPO BAILLY TEHSIL DALHOUSIE DISTT CHAMBA HP PIN 176303 | CHAMBA | HIMACHAL PRADESH | 176303 | L5 | Rejected-Finance Being Not L1 |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
15 Oct 2022, 6:00 pmClosed
AGE(I) DALHOUSIE
AGE(I) DALHOUSIE PIN-176305
CERTAIN REPAIR REPLACEMENT OF US SECURITY STREET LIGHT and MISC WORKS AT GEMINI TICCA AND BALOON AREA AT DALHOUSIE
2022_MES_552056_1
8897/2022-23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE(I) DALHOUSIE
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
AGE(I) DALHOUSIE
₹18,000
Yes
AGE(I) DALHOUSIE
16 Dec 2022
15 Sept 2022
17 Oct 2022
15 Sept 2022
15 Oct 2022
30 Sept 2022
15 Sept 2022 - 24 Sept 2022
24 Sept 2022
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m for laying cables, stays etc and getting out in hard dense soil all as specified.
Removal of surplus soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified
Material and labour for dry sand in trenches cushioning to under ground cable spreading, levelling hand punning complete all as specified and directed.Note- Punned down thickness will be measured for payment purpose.
M&L for bricks common burnt old size sub class `B' bricks laid dry for cable protection flat width wise complete all as specified and directed.
M&L and jointing testing and commisioning in replacement XLPE LT UG Cable insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade, laid in trenches / ducts / encased in GI pipe / fixed to pole/wall etc Make of LT UG Cable- Havells / KEI/ Polycab/Grandlay or equivalent and including taking down old unserviceable cables complete all as specified and directed of following sizes :-
Cross sectional area 3.5 core 95 Sqmm
Cross sectional area 4 core 35 Sqmm
Cross sectional area 4 core 10 Sqmm
Supply & lay GI tubing light grade 40 mm dia bore in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc all as specified and directed.
Cutting of road / hard standing upto a size not exceeding 20 cms in width and not exceeding 60 cms in depth for laying of LT UG cable protection pipe line making good the disturbed portion so as to match existing finishing or with PCC 1:2:4 type B1 complete all as specified and directed.
M&L for preparation of surfaces, scraping of old paint of steel surface of poles and applying two coats of aluminium paint of LT steel tubular pole 9 metre hight, Including fixing of reflection tape/reflection paint in altternate three coloured of width 6" on poles 1.5 to 1.8 metre above the ground level including writing pole number with black letter under yellow circle complete all as specified and directed. Note :- The reflection tape/reflection colour shall be as directed by Engr-in-charge.
Unbinding from insulators ACSR conductor any size of LT over head line for repairs, restretching of ACSR conductor to achieve proper sag and rewinding to the insulators using aluminium/GI wire all as required at site or directed. Note:- Distance between two poles irrespective of no of lengths of conductor shall be considered as a single span.
Cutting/ trimming of tree branches clearing 5 metres horizontal and 5 metres vertical distance from both sides of conductor including removing branches from site, complete all as specified & directed. Note:- (i) Clearing branches from both sides of conductor in between two consequtive poles shall be considered as one span irrespective of distance between poles. (ii) Cost of T&P required for cutting and removing branches shall be deemed to be included in rate quoted by bidder.
Outdoor type factory made bus bar chamber of size 0.75 x 0.45 x 0.40 metres depth made out of CRCA sheet 3.15mm thick with 4 No's aluminium bus bars of capacity 200 Amps,with colour code supported on insulators, internally prewired having locking arrangement, handle, provision of suitable hole at bottom for incoming and outgoing under ground cables, panel having angle iron frame made of 40 X 40 X 6 mm angle iron and 50 cms long legs made of 40 X 40 X 6 mm angle embedded upto 20 cms in PCC & 30 cms clear above ground complete including painting with two coats of powder coated paint over a coat of red oxide primer on exterior and interior faces, errection of Bus Bar chamber duly grouted in PCC M-15, type B0 using 12.5 mm graded crushed stone aggregate including earth work complete all as specified and directed.
Supply & fixing of Automatic Street Light Control Switch using Infrared Sensor based NATURE SWITCH for automatic switching of Street Lights. Nature Switch operation should be based on Natural Light Lux* level. Required Illuminance Level for Switching ON is ≤ 30 Lux and for Switching OFF ≥ 10 Lux. The Sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs.Three-Phase load of 8kW (Swadeep-02EC8kW3P) with 3 nos. Contactors, 3 nos. Incoming MCBs & 3 nos. Outgoing MCBs of 20-32 Amps each & Circuit wiring (Copper) of min.10 sq.mm The Sensor along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Enclosure conforming to IP54. The circuit should also have provision for Manual Operation (i.e. Sensor By-Pass option). complete all as specified and directed Make- CG/Philips or equivalent.
Supply and fixing in replacement of street light luminaire of HPSV with LED street light fitting consist of die cast body with heat resistant toughened glass having IP 65 protection level of 45/48 Watts complete all as specified and directed. Make- Havells part No. ENDURAPEARLNEOSL45WLED757PASYTOPC or Eqvt Make of Philips/CG/ Wipro/Bajaj/Halonix.
All as per item No 35 above but of of 70/72 Watts. Make- Havells part No. ENDURACITYLINERNEOSL70WLED757PASYBOTG or Eqvt Make of Philips/CG/ Wipro/Bajaj/Halonix.
Supply and Fixing in replacement with 1.0 sqmm 3 core PVC insulated and PVC round sheathed multistranded copper conductor flexible industrial cable 1100 V grade drawn through supply and fixing PVC conduit (junction box to street light fitting) in street light poles and Disconnection of street light fittings and refixing complete all as specified and directed.
S & F in replacement U/S GI Brackets with GI pipe medium grade 32 mm dia 1.5 mtr long with 02 nos clamp made out of MS flat iron 40 x 6 mm of suitable size fixed with bolts,nuts and washers including drilling holes and grouting with the same for fixing bolts complite as required duly painted with two coat of aluminum paint and fixing the existing street light fitting complete all as specified and directed. (Rate quoted by the contractor shll deemed to include for nuts and bolts).
M&L in replacement for Earthing complete with galvanised steel earth plate electrode 60 X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to and inclduing GI Strip 25X4 mm as earthing lead, by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No 5 of MES SSR Part I and testing on completion inclduing excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, and cover 6 mm thick in cement concrete (1:2:4) type B1, funnel with wire mesh, GI watering pipe 20mm dia medium grade and lugs complete all as specified and directed with earth resistance not more than 1.0 OHMS. Note- In case earth resistance more than 1.0 ohms, the contractor wiil re earthing at no extra cost.
M&L in replacement of FRP junction box of size 300 X 200 X 105 mm having 4 Nos aluminium bus bar of size 25X4 mm fixed on epoxy insulators with MCB SP 6 Amps,fixed on the pole with 02 Nos clamps,nut bolts etc.complete all as specified and directed. Make- Sintex or equivalent.
S&F in repairs for rigid non-metallic PVC conduit of 20 mm dia heavy duty along steel tubular swaged poles for wire from junction box to fittings fixed with 04 Nos MS clamps complete all as specified and directed.
Notes for Srl Item No. 1.00 to 21.00:-. GUARANTEE FOR LED LUMINARIES and others items : All LED luminaries and other items incorporated in the subject work shall be guarantee for a minimum period of 02 (Two) years from the date of issue of completion certificate. Any part / work found defective during these periods shall be replaced or rectified by the contractor at his own cost. Contractor shall also submit Manufacturer’s test certificate, Purchase Vouschers and Guarantee certificate of LED light fittings and other items mentioned.
M/s Shakti Electric Works
M/s. Rishav Sood
malghotra construction co
Havish Construction
m/S Varun Gupta
KEWAL SONS
M/S Ajay Kumar Mahajan
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .