Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC | L1 | Accepted-AOC Found 1st Lowest | |
| 2 | L2₹5.0 L+₹450 (0.09%)Rejected-AOC | L2 | Rejected-AOC Found 2nd Higher | |
| 3 | L3₹5.0 L+₹2,190 (0.44%)Rejected-AOC | L3 | Rejected-AOC Found 3rd Highest |
Tender Value
₹5 L
EMD Value
₹5,000
Closing Date
31 Jan 2022, 1:00 pmClosed
SUPERINTENDING ENGINEER, EDC, BANDA
Chilla Road, Indira Nagar, Banda
Repairing and Maintenance of damaged OCB/VCB/Relay, including replacement and wiring testing of damage parts under EUDD, Banda
2022_DVVNL_674232_1
EDCBNDA-45/2021-22
Open Tender
Electrical Works
Item Rate
180 days
BANDA
As per annexured
2 documents required · 2 mandatory
₹1,180
DVVNL
₹5,000
O/O SE, EDC, BANDA
21 Jan 2023
10 Jan 2022
31 Jan 2022
10 Jan 2022
31 Jan 2022
10 Jan 2022
27 Jan 2022
Amount
The work of REPAIRING & MAINTAINANCE OF DAMAGED OCB/VCB & RELAY ALSO, INCLUDING REPLACEMENT OF DAMAGE PARTS & WIRING TESTING OF OCB/VCB/RELAY installed at various 33/11 KV Sub-Stations under O&M Head Year 2021-22 under EUDD, BANDA, including arrangement, loading, unload, safely stocking/drugging of material by contractor use in during of replacement work, details of the work as given below :-
Testing of 33/11 KV Sub-Station, it includes primary injection, test of CT to test tripping of pannels on actual load.
Repairing of digital relay of 11 KV pannel, relay repairing includes - Cleaning of contacts, replacement of damage part of digital relay/ocb/vcb and testing. After repairing re-installation of relay/other parts and proper testing of protection (If relay/other parts found damage during testing).
Repairing of earth fault and over current relay of 11 KV panel relay repairing includes - cleaning of contacts, replacement of damage part of earth fault and over current relay and testing after repairing re-installation of relay and proper testing of protection (If relay found damage during testing).
To test & repairing electrical wiring of 11 KV pannels and to replace damaged amp. Meter and volt meter (If relay found damage during testing).
To repair damaged electrical tripping via inserting rated current at primary site of incoming and out going feeder of 33/11 KV Sub-Station and to test tripping through relay.
M.S. ENGINEERING WORKS
ASTHA ENGEENEARING WORKS
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Tendernotice_1.pdf
Tender Document • 1.47 MB
Openingdateextensioncorrigendum45-47New1.pdf
Tender Document • 0.16 MB
Openingdateextensioncorrigendum45-47New2.pdf
Tender Document • 0.16 MB
TENDER_FORM_045.pdf
Tender Document • 0.58 MB
Form-A.pdf
Tender Document • 0.16 MB
BOQ_1075267.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .