Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.0 L+₹1.1 L (13.0%)Rejected-Finance NAGAR PANCHAYAT PATHARDEVA DEORIA | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹10.5 L+₹1.6 L (18.0%)Rejected-Finance NOT FOUND | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹12.4 L+₹3.6 L (40.2%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
24 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) SIRSA
GE (AF) SIRSA-125055
CERTAIN REPAIR/MAINT OF E/M NATURE OF WORKS FOR INSTALLATIONS UNDER WSA AT AF STN SIRSA
2023_MES_605638_1
GE/SRA/T-34/2023-24
Open Tender
Miscellaneous Works
Item Rate
210 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) SIRSA
₹30,000
Yes
26 Sept 2023
26 Jun 2023
25 Jul 2023
26 Jun 2023
24 Jul 2023
10 Jul 2023
27 Jun 2023 - 1 Jul 2023
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L for Flameproof Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Metallic ERW Conduit 19/20 mm in size, medium grade, ISI marked and its Accessories with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed. NOTES :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring and making good shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage) (iii) All light points to be controlled from outside of the building.
M&L for Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable, drawn through and including Rigid Metallic ERW Conduit 19/20mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, Earth Continuity Cable connected to Common Earth dolly for ONE 6 PIN SOCKET 16 AMP ON INDEPENDENT BOARD, complete all as specified and as directed. (NOTES :- (i) Quoted rate shall be deemed to be inclusive of the cost of terminal box & laminate cover. (ii) Cost of cutting chases for concealed wiring and making good shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
-ditto- but using 4.0 sqmm FRLSH wire for both mains and earth wire in and including 19/20 mm Rigid Metallic ERW conduit complete
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in existing steel conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTE: Wiring shall be done in existing conduit. Quoted rate shall be excusive of the cost of conduit)
All as per item No. 06 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box in existing conduit).
All as per item No. 06 above but using 4.0 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 4.0 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box in existing conduit).
S&F Flame Proof Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable along with the Wiring drawn in ERW/GI CONDUIT including taking down existing sub main wiring complete all as specified and directed. (NOTE: Conduit shall be measured and paid separately)
S&F Flame Proof Sub-main Wiring with 2-Runs of 10.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable along with the Wiring drawn in ERW/GI CONDUIT including taking down existing sub main wiring complete all as specified and directed. (NOTE: Conduit shall be measured and paid separately)
S&F in repair ERW Conduit of size 25mm dia including Taking down/out Old Unserviceable Conduit in recess on wall, ISI marked, heavy duty with all Conduit Accessories and Making Good Surfaces to match the Exiting Treatment (as per Site requirement) , complete all as per specified and as directed. (NOTE: Quoted rate shall be deemed to include cost of cutting chases for concealed wiring and making good as per existing specifications. No claim in this regard shall be entertained at a later stage)
S&F in repair ERW in recess on wall Conduit of size 32mm dia, ISI marked, heavy duty with all Conduit Accessories and Making Good Surfaces to match the Exiting Treatment (as per Site requirement) including Taking down/out Old Unserviceable Conduit, complete all as per specified and as directed. (NOTE: Quoted rate shall be deemed to include cost of cutting chases for concealed wiring and making good as per existing specifications. No claim in this regard shall be entertained at a later stage)
S&F Flameproof Fan Regulator, Single Pole, 230 Volt, Electronic type and complete all as specified and as directed.
S&F Switch Flame Proof Rotary type with Termination Box in LM6, 16 Amp, Single Pole, 250 Volt , complete all as specified and as directed.
S&F Flame Proof, Weather Proof Switch Socket with Plug Combined in LM6, Termination Box in LM6, 16 Amp, 250 Volt, 2 Pin and Earth Plug, Fully Interlocked suitable for installation in hazardous as per IS-2147/62 Aluminium alloy/Cast Iron Neoprene Gasket Degree of Protection IP 65 and, complete all as specified and as directed.
S&F Flame Proof, Weather Proof Switch Socket with Plug Combined in LM6, Termination Box in LM6, 25 Amp, 415 Volt, TPN, 3 Pin and Earth Plug, Fully interlocked suitable for installation in hazardous as per IS-2147/ 62 Aluminium alloy/Cast Iron Neoprene Gasket Degree of Protection IP 65 and Certified CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked and complete all as specified and as directed.
S&F Flame Proof Weather Proof LED Tube Light Fitting 2x20 Watt (4 Feet) with product in Aluminium Die-cast Alloy LM6 complete with Construction of Gas Gr. IIA, IIB, Tested and Certified by CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked and Electrically Connecting up and , complete all as specified and as directed.
S&F in repair Flameproof LED Flood Light fitting, of 120 WATT capacity, in high pressure die cast LM6 aluminium housing, certified by CMRI Dhanbad, with lens and toughened glass cover with integrated constant current electronic driver complete all as specified and directed and complying with the following specifications:-. (a) minimum efficacy 120 lumen/watt (b) CRI not less than 80, (c) THD < 25% (d) Power factor not less than 0.95 (e) having in built short circuit and surge protection up to 5 kV (f) colour temperature not less than 5700 degree K (g) life not less than 50000 hours of operation (h) Weather protection grade: IP65 (NOTE: (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work.. (2) Wire for electric connection shall be measured and paid separately)
S&F in repair MCB Single Pole, 6 to 32 Amp, 240 Volt, AC, 'C' Series for fixing on MCB DB’s, 10 kA, 50 Hz including Connecting up and testing complete all as specified and directed
S&F in repair MCB Single Pole & Neutral, 32 Amp, 240 Volt, AC, 'C' Series for fixing on MCB DB’s, 10 kA, 50 Hz including Connecting up and testing complete all as specified and as directed.
S&F in repair Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed.
S&F in repair SPN DB, IP 43 protection, double door, 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed.
S&F in repair MCCB, 4 pole, 100 Amps, 16 kA, 415 Volts, AC, 50 Hz with and including adjustable thermal and magnetic setting, fixed in DB complete all as specified and directed.
S & F in repairs, installation, commissioning and testing Polycarbonate ASTA CPRI approved OEM made LT FEEDER PILLAR shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance, Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE OF DEGREE OF INGRESS PROTECTION IP65 IN ACCORDANCE WITH IEC 60529 and the share panel assembled by OEM, channel partner or sister concerned assembly will not be accepted. The ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The gasket should be internally embedded made of polyurethane. The panel should pass glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing]. LT Feeder Pillar size 90cm x 60cm x 17 cm,415 volts for outdoor use, with Copper TPN Bus Bar 40 x 10 mm ( 300 Amp ) Fixed on insulators on PVC / epoxy insulators, mounted on angle legs of size 25mm x 25mm x 5mm frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC(1:2:4) Type B-1 (using 20 mm graded stone aggregate) complete with suitable cable Glands/Grommets and including all provision of opening for incoming/outgoing cables and testing complete all as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm (up to 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
Supply, laying and installation of HDPE pipe of bore 40 mm size , PN-10 along with all fittings and fixed complete all as specified and as directed.
Supply, installation, testing and commissioning of maintenance free chemical earthing station using 17.2 mm dia, 3000 mm long high tensile low carbon steel circular rod, molecularly bonded with copper on outer surface (minimum copper bonding thickness of 250 microns) meeting the requirements of Underwriters Laboratories (UL) 467-2007 or latest, with 250 mm long copper strip of size 50 x 6 mm, exothermally welded on top of electrode complete including augering (boring) 100-125 mm dia hole as required for electrode in any type of soil and back filling with carbon based ground enhancing compound (GEC) compound (with minimum qty 75 Kg per electrode) conforming to IEEE/BS standards complete all as specified and directed. (NOTES :- 1) The acceptable earth resistance at earth bus bar/test point shall not be more than 01 Ohm. At certain locations, it may not be possible to achieve earth resistance of < 01 Ohm with one electrode/pit due to higher soil resistivity. In such cases, provision of loop earthing consisting of more than one earth electrode pits shall be done. The number of pits required shall be decided based on the resistivity of soil and resistance achieved for the earth pits already installed. The distance between two successive earth electrodes shall not be less than 3 metres. The procedure mentioned below for one earth pit shall be repeated for other earth pits. Additional earth electrode pits and loop conductor shall be measured and paid separately under respective items. 2) Bore dia of earthing should be minimum 200mm. 3) Cost of Ground Enhancing Compound is deemed to be included in the quoted rate.
S&F copper strip 20 mm X 3.15 mm with saddles and fixing screws etc, for roof conductors and down conductors above ground including provn of porcelain insulator @ 1.0 m spacing complete all as specified and directed. Note: Cost of Screws, Saddles, insulator, Nuts and Bolts, etc. will deemed to be included in the Quoted Unit Rate.
S&F Aluminium strip 25x3.15 mm with saddles and fixing screws for roof/earth conductor and down conductors above ground including provn of porcelain insulator @ 1.0 m spacing complete all as specified and directed. Note: Cost of Screws, Saddles, insulator, Nuts and Bolts, etc. will deemed to be included in the Quoted Unit Rate.
S&F galvanised iron tubing/pipe 40 mm bore (dia), light grade for strip protection, fixed on walls/floors/pole with suitable type of clamps, etc complete all as specified and as directed
M&L for replacement of test point terminal block made of gun metal or phosphorous bronze size 75x75x25mm, drilled and screwed including 3 No. 8 mm dia, 25 mm long hexagonal head screw, complete all as specified and as directed
S&F air termination single pointed copper rod 20 mm dia with brass base and 300 mm long with arrester clamp 16 mm made out of brass including provision of cement concrete 1:2:4 (20 mm graded aggregate stone) block 300 x 300 x 300 mm complete all as specified and as directed.
M&L Load Testing of flameproof/non flame proof EOT Crane up to 6 Ton, Load capacity to prove the satisfactory Operation of Electrical Controls, Motors, Gear Boxes, Protective Devices, system Interlocks and Mechanical components like Wire Rope, Weld Sections check/welding to existing Channel of the Crane in all Motions (LT CT Hoist in High Speed and Creep Speed) during Full Load and testing of Crane in Over Load at 100 + 25% in presence of Representative of AF Sirsa including all Consumables Items, complete all as specified and as directed by Engineer-in-Charge. NOTE :-(I) (a) Load Blocks in denomination of total tonnage of crane + 25% will required quantity shall be provided by the Contractor at his own Arrangement and Cost including shifting of these Blocks near to the Crane Load required for lower denomination for which Contractor has no Extra Claim. Cost of Transportation and Handling Charges are also deemed to be included in the Quoted Unit Rate. (b) Load Tests are to be carried out by the Contractor minimum ½ to 1.0 Hour duration though an Expert/Trained Technician in the relevant Field in presence of Department Representative and will record the Test. (c) Contractor will be responsible for Servicing of Crane before Load Testing. Cost of all Consumable Items will be deem to include in the Quoted Unit Rate including Brake Oil, Gear Oil and Grease etc. (d) Deflection Test of EOT Crane should be done by any expert agency or experienced technician. and permissible test result should be submitted by the contractor of each crane.
(e) Contractor will submit all the possible test certificate duly signed by user/AF authorities , provided by EOT crane expert /firm/company to the department after each Crane testing. (II) Existing Make of EOT Cranes are Rockwell/ Tib Udhyog or as per site available. (III) Contractor will change/top up Gear oil of cranes and hydraulic oil for thrusters during the repair of Cranes (IV) Contractor will do hot dip galvanization process to avoid metal to metal contact of some important parts like wheels, hook, rope drums etc. (V) Cost of all type tests/Gear oil/hydraulic oil/galvanization process, will be treated as EACH JOB only. and cost will be included in quoted rates by contractor
S&F in repair Contactor 3 Pole suitable for 5 to 24 Volt, DC 40 Amp, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Heavy duty Limit Switch with 2NO + 2NC, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Normally Closed/ Normally Open Switch, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Push Button in Yellow/Blue Colour, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair PVC insulated, sheathed, stranded Copper Conductor Cable of size 1.5 Sqmm, 12 Core, 1100 Volt grade, heavy duty, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Thermal Over Load Relay of setting range 32 Amp, 415 Volt, 50 Hz, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Transformer 3 Phase 50 VA (as approved as per existing one) having conversion capacity of 3 Phase 380 Volt, 400 Volt & 415 Volt to 110 Volt, 30 Volt, 24 Volt & 12 Volt, complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs Wire Rope maximum 15mm dia, multi-stranded of existing Shape and Size, properly fixed and tested complete all as specified and as directed by Engineer-in-Charge.
S&F in repair flameproof crane pulley, as per existing size and type complete, properly fixed and tested complete all as specified and as directed by Engineer-in-Charge.
M&L for Realignment of Crane Rail Track including removing of Rail and replacing the damaged and perished Rubber Padding wherever and replacing the worn out Bolts, Nuts and Washers including welding new Mild Steel Clamps wherever necessary and checking of Bends straightening and refixing the Rails including Provision of necessary Packing Shoes and ensure Proper Alignment including necessary Welding Works at Corners, etc., complete all as specified and as directed by Engineer-in-Charge.
M&L for painting to Panels HT/LT and HT feeder panels/Pillar Box any size installed at all AOR with two coats of super enamelled paints of approved colour with spray painting machine incl preparation of surface complete all as specified and directed.
Excavation in trenches (manually) not exc 1.5 m wide and not exceeding 1.5 m depth for foundation laying of cables etc and getting out in soft loose soil all as specified and directed. (NOTE:- Mechanical excavation shall not be allowed)
Returning filling including spreading levelling watering and well ramming in layers n.exc 25 cm in soil completed all as specified and directed.
Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point as in soil complete all as specified and directed.
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) up to 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
Supply & laying in Trenches Sub-class ‘B’ Bricks, kiln burnt, laid perpendicular to the cable for Cable Protection, complete all as specified and as directed.
Laying only old bricks (retrieved during taking out of cable) in trenches above sand cushioning for cable protection complete all as specified and as directed.
M&L for Fault detection UG Cable by using cable fault detector/locator vehicle mounted to a accuracy of 2 mtr for various location of any size and type up to 11 KV. NOTE- (i) After location the fault the rectification of the fault is the sole responsibility of the contractor (ii) The cable straight through joint/ end termination will be measured and paid separately in relevant items
Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole incl necessary aluminium thimbles, jointing and testing incl taking down/up unserviceable LT cable incl necessary disconnection for repair/ replacement etc (from cable duct/underground trench / pole), stacking properly (cable, pipe and bricks) complete of the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
50 Sqmm, 3.5 core
95 Sqmm, 3.5 core
120 Sqmm, 3.5 core
S&F heat shrinkable straight through Joints using suitable jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :-
25 sqmm to 50 sqmm, 3.5/4 core
70 sqmm to 120 sqmm, 3.5 core
Supply install test and commissioning of acoustic insulation of duct as shown on drawing with 25 mm resin bonded fibre glass, of 48 kg/cum density, covered with and 28 G Aluminium perforated sheet complete all as specified and directed.
Supply, install, testing and commissioning of thermal insulation of duct exposed to out side weather conditions with 15 mm thick closed cell chemically cross linked fire retardant polyethylene foam insulation of density 30 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C, covered with aluminium faced foil complete with application with rubber based adhesive Pidilite SR 505/998 and 50mm x 3 mm thick self adhesive tape on both longitudinal & transverse joints etc.
Repair /servicing and re-winding of centrifugal mono block type Hot water pump set capable of delivering 30 USGPM of water against 28.00 mtr head for 100% capacity, taking out pump set from WSA AC Plant to outside workshop by contractor under his own arrangement, opening of pumps sets, check winding, all type of related parts, repairing and re-fixing on site and testing complete all as specified and directed. (NOTE: Cost of re-winding and pump parts shall be deemed to be included in the quoted rates)
Repair /servicing and re-winding of centrifugal mono block type Hot water pump set capable of delivering 40 USGPM of water against 28.00 mtr head for 100% capacity, taking out pump set from WSA AC Plant to outside workshop by contractor under his own arrangement, opening of pumps sets, check winding, all type of related parts, repairing and re-fixing on site and testing complete all as specified and directed. (NOTE: Cost of re-winding and pump parts shall be deemed to be included in the quoted rates)
Repair /servicing of Electric Hot Water Generator of 40.0 KW complete with control panel and standard accessories for winter & Monsoon Re- Heating complete with controls i.e. thermostat and humidistat with control wiring for maintaining the RH as specified and directed (NOTE: Cost of all accessories required for servicing of Hot water Generator will be brought by contractor and no extra amount shall be paid to contractor on this account)
S&F in repair LED Board for AC Plant and WSA Substation of size 3.0x2.0x0.75 m with suitable embedded letters written as decided by Engr in charge including all kind for fitting/Angle iron/Structure/PCC Work and electrical connections required on site, fixed on wall complete all as specified and directed.
M/s Shree Bala Ji Construction Company
shiv shanker enterprises
BHATIA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .