Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC AT PO PHUSRO DIST BOKARO JHARKHAND 829104 | BOKARO | JHARKHAND | 829104 | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.2 L+₹20,000 (1.82%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹11.6 L+₹61,200 (5.56%)Rejected-Finance 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹16,300
Closing Date
3 Mar 2025, 9:00 amClosed
PE ENM
PE ENM, AKKOCP
Shifting of Substation transformer and structures , Installation of 02 nos Capacitor bank, A) 400 KVAR ,Make AB Power and B) 400 KVAR , Make Madhav including all required work in respect of AKKOCP,BnK Area
2025_CCL_329843_3
PE(EnM)/AKK OCP/e-tender/24-25/61
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
AKKOCP
Please refer Tender documents.
2 documents required · 2 mandatory
₹16,300
20 May 2025
21 Feb 2025
4 Mar 2025
22 Feb 2025
3 Mar 2025
22 Feb 2025
22 Feb 2025 - 3 Mar 2025
Amount
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Supplying and filling in plinth with Jamuna sand under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5.0 in foundation and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand).
Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 5.0 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
12mm cement plaster of mix 1:6 (1 cement : 6 fine sand).
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80 mm thick with zinc coating not less than 275 gm/ m²
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Flashing/Aprons (Upto 600mm)
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 65 mm dia. nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50mm to 80mm nominal bore.
Supply of earthing electrode system 78mm x3M with for chemical earth pit making ( The merger value of earth pit should not be greater than 01 at the time of installation) including excavation and refilling
Supply of high grade Ground Black Fill Compound (GBFC) Bag (approx. 25 kg each)
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe FRLS on earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
shifting pulling and installation of 400 KVAR capacitor bank on foundation
shifting pulling and installation of circuit breaker switch on foundation
Dismantling of GOAB switch
Fitting and fixing of GOAB switch
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supply and providing of terminal end connector.
Supply and installation of limit switch 110V operating.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required
Dismantling of steel structure approximetly weight 600 Kg
Erection of steel structure approximetly weight 600 Kg
shifting and installation of 33KV/440V, 300KVA sub station transformer
Total impact of GST for the purpose of CTC
M/S SHREE TIRUPATI TRADERS (BID ID -1134292)
M/s Kiran Electrical works (BID ID -1134277)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .