Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC PR CDA SC PUNE 01 THROUGH AO GE DEHU ROAD | L1 | Accepted-AOC Accepted as L1 | |
| 2 | L2₹31.2 L+₹1.6 L (5.44%)Rejected-Finance | L2 | Rejected-Finance Reject | |
| 3 | L3₹33.3 L+₹3.7 L (12.6%)Rejected-Finance | L3 | Rejected-Finance Reject |
Tender Value
₹28.3 L
EMD Value
₹56,600
Closing Date
13 May 2020, 6:00 pmClosed
GE DEHU ROAD, PUNE
GE DEHU ROAD, PUNE
PROVN OF COVERED SHED FOR PLANNER DRILLING CUTTING MACHINE FOR DEPOT WKSP SPECIAL REPAIRS FOR REPLACEMENT OLD MS VALLEY GUTTERS TO GALVANISED STEEL VALLEY GUTTERS OF SHED NO 50 1 SD SHED NO 58 3 SD SHED NO 4 SD COD UNDER AGE BR EAST AT GE DEHU ROAD
2020_MES_339543_1
8428
Open Tender
Civil Works
Item Rate
270 days
GE DEHU ROAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE DEHU ROAD, PUNE
₹56,600
Yes
9 Jun 2020
18 Apr 2020
20 May 2020
18 Apr 2020
13 May 2020
29 Apr 2020
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / Loose soil all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil all as specified and directed.
M & L for 150 mm thick Cement concrete Type D-2 1:4:8 ( 40 mm graded aggregates) in foundations, filling and mass concrete all as specified and directed.
M & L for Reinforced cement concrete (Design mix) M - 25 (20 mm Graded Aggregates) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and directed.
M&L for form work to sides of Concrete foundatins, footings, bases of columns,plinth beams for rough finished surfaces of concrete flat all as specified and directed.
M&L for RCC M 25 Design Mix using 20 mm graded aggregate in columns, pillars,piers, posts and struts etc all as specified and directed.
M&L for form work to sides of pillars, posts, struts, piesrs, columns and stanchions etc for rough finished surface of concrete flat all as specified and directed.
M & L for Pre-cast cement concrete block masonry Type - C1 1:3:6 (20 mm Graded aggregates) with solid blocks, exc. 10 cm in width and setting in CM 1:6 all as specified and directed.
M & L for Rendering 10 mm thick in CM 1:6 on fair faces of PCC block masonary or concrete surfaces to be finished even and smooth (without using extra lime cement) all as specified and directed.
M & L for Rendering 15 mm thick in CM 1:4 on other than fair faces of PCC block masonary or concrete surfaces to be finished even and smooth (without using extra lime cement) all as specified and directed.
S & F Steel rolling shutters thickness of laths 1.25 mm, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete:but gear operated type with bevel gear box and crank handle all as specified and directed.
S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars , dovetailed or welded all as specified and directed.
S & F, framed work such as grills, grating etc. with ends of bar shoulder and/or riveted, or forged into spikes, framed guard bar conforming to Fe-410-W (Gde E-250) quality A complete all as specified and as directed.
S & F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed.
S & F Sheet glass of thickness 3 mm , ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane all as specified and directed.
S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe 410 -W (Gde- E- 250) quality- A all as specified and directed.
M&L Steel reinforcement TMT bars 10mm dia and over, cut to length bent to to shape required including cranking, bending, hooking ends, binding with and incl mild steel wire annealed not less than 0.9 mm dia all as specified and directed.
All as per item No 17. above but 5 mm dia and over upto and including 10mm dia as in stirrupsall as specified and directed.
M & L for preparation of new plastered surface and apply two coat of distemper oil emulsion over a coat of priming plastered surfaces with alkali resistant priming paint all as specified and directed.
M & L for preparation of new plastered surface and apply two coat of cement base paint over a coat of Chalk whiting on plastered surfaces all as specified and directed.
M & L for preparation of new Surfaces of steel and iron any description, over 10cm in width or girth and apply two coats of synthetic enamel paint over a coat of red oxide all as specified and directed.
S & F Anodised aluminium snap grid (Size of grid 605 x 605mm) frame work for false ceiling all as specified including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting levelfixed to roof slabs by means ofceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
M & L for 12 mm thick Perforated particle board/ tiles for insula-tion and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with stapleson snap grid all as specified and directed.
S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe 410 -W (Gde- E- 250) quality- A all as specified and directed.
S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,but length of bolt exc 10cm and n exc 15cm long and diameter of neck 11 to 15 mm all as specified and directed.
S & F Pre-painted/colored galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
All as per item No. 26 above above but plain sheet fix in valley gutter / ridge complete all as specified and as directed.
M & L for 75 mm thick Cement Concrete Type C-2 1:3:6 (40 mm Graded aggregates) in Plinth protection all as specified and directed.
M & L for Providing cement concrete Type B-1 1:2:4 ( 20 mm Graded aggregates) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, all as specified and directed.
M & L fo Reinforced cement concrete (nominal mix) in Type B-1 1:2:4 ( 20 mm Graded aggregates) in chajja all as specified and directed.
M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as specified and directed.
M & L for Hardcore of broken stones or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed.
M & L for Cement Concrete Type D-2 1:4:8 ( 40 mm Graded Aggregates) in sub base for floors all as specified and directed.
M & L for Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in soft/Loose soil all as specified and directed.
Removing excavated material (Soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed.
M & L for Formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete flat all as specified and directed.
S & F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as specified and directed.
M & L for Glass dividing strips, 3 mm thick width of strip 22 mm.inserted in position, conform to design all as specified and directed.
Taking down / Dismantling Plain or corrugated steel sheeting any gauge, thickness, including nainital or similar pattern roof coverings etc all as specified and as directed.
S & F plain, galvanised, mild steel sheeting 0.63 mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 all as specified and directed.
S & F , Galvanised, corrugated mild steel sheeting 0.63 mm with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts in lieu of screw and washers, in roofs, walls etc. with grade of zinc coating 275 all as specified and directed.
S & F , of Fibre glass reinforced translucent corrugated sheeting 2mm thick with two corrugations side lap & fixed with L-type or J-type or cranked hook bolts in lieu of screw with coach screw and washer in roof, wall etc all as directed by Engr-in-Charge.
Fixing only Galvanised, corrugated mild steel sheeting 0.63 mm with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts in lieu of screw and washers, in roofs, walls etc. with grade of zinc coating 275 all as specified and directed.
M & L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 all as specified and directed.
S & F , for mild steel bolts purpose made with hexagonal or square head one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut exceeding 30cm long of dia of neck in mm exc 20 and not exc 25mm all as specified and directed.
E/M Portion
Supply, laying, jointing, testing and commisioning XLPE cable 1100 volts grade PVC insulated armoured & PVC sheathed with stranded aluminium conductor heavy duty ISI marked incl cable glands lugs bolts nuts washers etc to suit the cable size to be laid in trenches fixed along pole, LT pannel floor bore or through GI pipe laid under floors, Fixed, concealed in wall encased in GI pipe etc complete of following sizes including taking down old unserviceable over head conductors and insulators channels carefully as directeed by engineer in charge .
70 Sq mm x 3.5 core
16 Sqmm x 4 core
10 Sqmm x 4 Core
10 Sqmm x 2 core
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out soft / loose soil all as specified and directed.
Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25 cm all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of excavation all as specified and directed by Engineer -in-Charge.
M & L for HDPE DWC pipe ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection of the following outer dia :- Make:-Infra/Supreme/Prince
40 mm dia
80 mm dia
M & L for earthing with galvanised steel earth plate electrode 60cmx60cmx6.3mm burried directly in ground earth pit not less than 2.25 m deep below normal ground level with top edge of the plate vertically to depth of not less than 1.2m below ground level connected to and including GI strip of size 25 x 4 mm as earthing lead welded with earth electrode (excluding GI protection pipe) and connecting to equipments by means of earthing lead connecting to equipments by means of GI bolts & nuts etc. with provision of char-coal and salt etc. all as per electrical plate No. 3 of SSR Part I, 2009 including RCC cover and MS angle iron frame watering arrangement with GI pipe 20mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork and testing on completion etc complete all as specified and directed by Engr-in-Charge. Note: Rate quoted deemed to be including excavation by compressor M/C for Soft disintegrated rock to required depth.
Supply instal testing and commissioning of CPRI approved factory make Bus bar chamber indoor type pedelstal mounted dust proof, weather proof, vermin proof front side single door hinge type with locking arrangement rear side single door hinge type with locking arangement, sheet steel cubical type with slanting roof made out of 3mm thick CRCA sheet with powder coated finished suitable length and size. High conductivity 3 phase and neutral copper bus bar of 400 Amps capacity for one input and five outputs duly mounted on pre cast insulators including earth work excavation, PCC foundation necessary coping work, nuts and bolts and connecting electrically with suitable cable lug, cable glands etc complete all as specified and directed . Incoming :- 100 amp MCCB,4 pole,Breaking capacity 25 KA Outgoing :- 4 Bus bars (20X 5 mm) to give 6 output cable connections including nut & bolts,copper Lugs etc.
Supply and Fix Star delta Starter fully automatic in sheet steel enclosure suitable for 415 V AC for 15 HP Motor Make :- Cat part no SS96257 of L&T or Equivalent
Supply and Fix Star delta Starter fully automatic in sheet steel enclosure suitable for 415 V AC for 7.5 HP Motor Make :- Cat part no SS96254 of L&T or Equivalent
Supply and Fix DOL Starter for 2 HP Motor Make :- cat part no CS90319KOCO of L&T or Equivalent
Supply & fix MCCB 63 Amp, 3 pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : L&T /LEGREND/ ABB/Sncheider/Standard
M&L for point wiring with 1.5 sqmm multistranded copper conductor cable of PVC insulated and unsheahed type alongwith 1.5sqmm PVC insulated unsheathed single stranded copper conductor cable for continous earthing in & incl casing / caping or PVC Pipes & accessories having ISI marked surface type to be fixed with proper screws/(MS steel strips if required) including hard PVC boards of suitable sizes & making arrangement for fixing switches, sockets, switch socket combination, fan, regulator setc for Note:- Screws used for fixing PVC boards, casing & caping ceilling rose square blocks etc should be nickel cadmium screws:-
One light point controlled by one switch
One fan point controlled by one switch & regulators
One socket 5 pin 5 Amps flush type on independent board
One socket 5 pin 5 Amps flush type on same board
M&L for point wiring with 2.5 sqmm single core multistranded copper conductor cable of PVC insulated and unsheathed type alongwith 2.5sqmm PVC insulated unsheathed single core multistranded copper conductor cable for continous earthing in & incl PVC casing / caping or PVC Pipes & accessories having ISI marked surface type to be fixed with proper screws/ (MS steel strips if required) including hard PVC boards/Boxes of suitable sizes & making arrangement for fixing switches, sockets, switch socket combination, fan, regulator etc for. Note:-color coding to be followed as given R-Phase, B-Neutral & G- Earthing
S & F in repair submain wiring with cable insulated single core multistranded copper conductor cable 1100 volts 2x 2.5 sqmm drawn through & incl PVC casing caping / PVC conduit of suitable size alongwith 1.5 sqmm copper conductor cable for earth continuity. (Note : 2 runs of 2.5 sqmm cable, one run of 1.5 sqmm cable and one run of PVC casing capping will be measured as one RM).
S&F switch piano flush type single pole one way 5 Amps
S&F switch socket combination 2 in 1, 5 Amps flush type
S&F switch socket combination 2 in 1, 15 Amps flush type
S&F ceiling rose surface type 65 X 50mm, isolated body with 3 terminals to be fixed on PVC block
S&F regulator electronic step type for ceiling fans suitable for AC 230 volts 50 Hz 1200 / 1400mm sweep
MCB DB SPN sheet metal enclosure double door suitable for mounting MCB 240 volts with 200 Amps rated busbar 6 way
S&F MCB SP 240 volts 6-32 Amps
S&F isolator SPN 40 Amps 240 volts
Supply and fix in repair LED Fitting 18 Watts LED MODEL:LHEXBQP71NWO18 MAKE : Havells or Equivalent
S&F in repair LED Security Light fitting of 25 W, Die cast Aluminium extruded housing with reflector and enclosed with toughened glass IP 65 for 1Wx18 Nos LEDs and Driver all as specified & Directed. Make : ENDURAPEARLS25WLED757SASYTOPC of Havells or equivalent inPhilips/ Bajaj/ CG/Luker
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated.
H S TAKHI
M/S B.A. GAIKWAD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .