Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹83.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹92.2 L+₹8.6 L (10.2%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹98.5 L+₹14.9 L (17.8%)Rejected-AOC 17 A KRISHNA SQUARE II NEAR GURUDWARA AMRITSAR | AMRITSAR | AMRITSAR | PUNJAB | L3 | Rejected-AOC Other than Lowest Bidder |
Tender Value
Refer Docs
Closing Date
15 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) CHANDIGARH
HQ CWE (AF) CHANDIGARH PIN-160003
PROVN OF WORK SERVICES FOR RELOCATION OF MPR RADAR AND ROHINI RADAR AT AF STATION AMRITSAR
2022_MES_500787_1
CWE/AF CHD/ASR/T-30/2021-2022
Open Tender
Civil Works
Item Rate
270 days
Amritsar
As per NIT
8 documents required · 8 mandatory
₹1,000
AGE (I) (AF) Amritsar
Exempted
23 Mar 2022
11 Jan 2022
22 Feb 2022
11 Jan 2022
15 Feb 2022
1 Feb 2022
60 days
Amount
BUILDING WORK
Material and labour for plain cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete, complete all as specified and directed.
Material and labour for RCC Design Mix M-25 using 20 mm graded stone aggregate as in foundations, footing of columns, plinth beams, basement slabs and the like complete all as specified and directed.
Material and labour for RCC Design Mix M-25 using 20 mm graded stone aggregate as in columns, pillers, posts, struts, upto 7.5 metres height, complete all as specified and directed.
Material and labour for RCC Design Mix M-25 using 20 mm graded stone aggregate as in columns, pillers, posts, struts, above 7.5 metres height, complete all as specified and directed.
Material and labour for RCC Design Mix M-25 using 20 mm graded stone aggregate as in beams, cantilevers, lintels over 1.5 mtr span upto 7.5 metres height, complete all as specified and directed.
Material and labour for RCC Design Mix M-25 using 20 mm graded stone aggregate as in beams, cantilevers, lintels over 1.5 mtr span above 7.5 metres height,complete all as specified and directed.
Material and Labour for RCC Design Mix M-25 using 20 mm graded stone aggregates as in slabs supported on walls,beams and columns in floors, roofs,, landings, balconies, canopies, deck slab,shelves and the like at any height, complete all as specified and as directed.
Material and Labour for RCC Design Mix M-25 using 20 mm graded stone aggregates as in spiral stair case (including landing) at any height, complete all as specified and as directed.
Material and Labour for RCC Design Mix M-25 using 20 mm graded stone aggregates as in spiral stair case (including landing), above 7.5 metres height, complete all as specified and as directed.
Material and labour for Formwork to sides and soffits of roof beams, lintels, cantilever, shelves, splay between floor and beam etc., flat rough finished concrete surfaces, upto 7.5 metres height, complete all as specified and directed.
Material and labour for Formwork to sides and soffits of roof beams, lintels, cantilever, shelves, splay between floor and beam etc., flat rough finished concrete surfaces, above 7.5 metres height, complete all as specified and directed.
Material and labour for Formwork to soffits of suspended roof slab, floor slab, landing and similar work, flat rough finished concrete surfaces, complete all as specified and directed.
Material and labour for Formwork to soffits of suspended roof slab, floor slab, landing and similar work, flat rough finished concrete surfaces, above 7.5 metres height, complete all as specified and directed.
Material and labour for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, flat rough finished concrete surfaces, upto 7.5 metres height, complete all as specified and directed.
Material and labour for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, flat rough finished concrete surfaces, above 7.5 metres height, complete all as specified and directed.
Material and labour for Formwork to staircases with sloping or stepped soffits including risers and stringers (excluding landing), upto 7.5 metres height, complete all as specified and directed.
Material and labour for Formwork to staircases with sloping or stepped soffits including risers and stringers (excluding landing), above 7.5 metres height, complete all as specified and directed.
Material and labour for Formwork to concrete foundations, footings, bases of columns, raft & raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work, vertical or to batter, flat fair finished concrete surfaces complete all as specified and directed.
Material and Labour for TMT steel bars, 10 mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete, upto 7.5 metre height all as specified and as directed.
Material and Labour for TMT steel bars, 10 mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete, above 7.5 metre height, all as specified and as directed.
Mild steel TMT bars 8 mm dia and over upto 10 mm dia as in stirrups, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, upto 7.5 metre height, complete all as specified.
Mild steel TMT bars 8 mm dia and over upto 10 mm dia as in stirrups, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, above 7.5 metre height,complete all as specified.
Material and labour for rendering 15 mm thick in cement mortar (1:4), on brick/concrete surfaces, finished even fair at any height, complete all as specified and directed.
Material and labour for Cutting opening in cement concrete walls (any descript-ion) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc., complete all as specified and directed.
Material and labour for rendering 10mm thick in cement mortar (1:3), on ceiling, finished even smooth without using extra cement at any height, complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces of ceiling and applying two coats of 1st quality oil bound distemper (oil emulsion) over and including a coat of alkali resistant primer, complete all as specified and directed.
Material and labour for preparation of old surfaces on walls by wire brushes, brooming down and using sand paper and stopping of surfaces & leveling /edging the disturbed places /edges using necessary filling compound and applying 2 mm thick Birla/JK wall care putty to obtain smooth regular/even finish and applying two coats of oil bound distemper, complete all as specified and directed.
Material and labour for preparation of old surfaces of ceiling by wire brushes, brooming down and using sand paper and applying two coats of oil bound distemper, complete all as specified and directed.
Material and labour for preparation of new surfaces of wall/ceiling/ramp etc and applying two coats of Acrylic weather coat emulsion paint in disruptive/camouflaging parttern having percentage of Tri-colour as 73.56% of RGB Value (98, 108, 90) Hex Code (#626C5A), 22.33% of RGB Value (158, 157, 145) Hex Code (#9E9D91) and 4.11% of RGB Value (158, 157, 116) Hex code (#9E9D74) as per sample approved by AGE (I) for building of height upto 7.5 metre, over and including a coat of alkali resistance primer complete all as specified and directed. Note:- The rate quoted by contractor is deemed to include necessary scaffolding for painting upto required height.
Material and labour for preparation of new surfaces of wall/ceiling/ramp etc and applying two coats of Acrylic weather coat emulsion paint in disruptive/camouflaging parttern having percentage of Tri-colour as 73.56% of RGB Value (98, 108, 90) Hex Code (#626C5A), 22.33% of RGB Value (158, 157, 145) Hex Code (#9E9D91) and 4.11% of RGB Value (158, 157, 116) Hex code (#9E9D74) as per sample approved by AGE (I) for building of height above 7.5 metre, over and including a coat of alkali resistance primer complete all as specified and directed. Note:- The rate quoted by contractor is deemed to include necessary scaffolding for painting upto required height.
Material and labour for preparation of old surfaces of wall/ceiling/ramp etc and applying two coats of Acrylic weather coat emulsion paint in disruptive/camouflaging parttern having percentage of Tri-colour as 73.56% of RGB Value (98, 108, 90) Hex Code (#626C5A), 22.33% of RGB Value (158, 157, 145) Hex Code (#9E9D91) and 4.11% of RGB Value (158, 157, 116) Hex code (#9E9D74) as per sample approved by AGE (I) for building of height upto 7.5 metre, complete all as specified and directed. Note:- The rate quoted by contractor is deemed to include necessary scaffolding for painting upto required height.
Supply and Fixing Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and directed.
Supply and Fixing MS Plates Fe 410 -W (Gde- E- 250) quality- A, (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, complete all as specified and directed.
Supply and Fixing Joist, channel, angle, or tee sections, Fe 410 -W (Gde- E- 250) quality- B, fixed independently, without connecting plates, etc. (cut to ordinary engths i.e. within 20mm of the length indicated), complete all as specified and directed.
Supply and Fixing Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, complete all as specified and directed.
Supply and Fixing Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick, of any colour (as approved by GE), having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Material and labour for Mild steel bolts purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut exc 30cm long and dia of shank 12 to 20 mm, complete all as specified and directed.
Material and labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 cm but not exc 10 cm long and dia of shank 16 to 20 mm, complete all as specified and directed.
Material and labour for cutting holes in brick wall built in cement mortar for taking out/ inserting hold fasts , and making good disturbed portion in cement mortar (1:3) or cement concrete 1:2:4 type B-1 as required, depth of embedded portion of hold fasts measured from the face of the jamb into the wall exceeding half brick but not exceeding one brick thick , and removal of rubbish outside defence land complete all as specified and directed
Material and labour for brickwork with using subclass 'B' old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6), complete all as specified and directed.
Hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread, levelled in layers not exceeding 15 cm thick ,watered and rammed to a true surface, complete all as specified.
Material and labour for pavement quality concrete (PQC) as per design mix (as per IRC 44 specifications) using graded crushed stone aggregate, having minimum field flexural strength of 40 Kg/Sq cm in pavement, ( min cement content shall be 400 Kg / cum using OPC 43 gde) and super-plastisizer, if required, laid to level, gradient and camber, spread, paved, campacted & finished including belting & brooming complete all as specified and directed. Note:- (i) In the event of increase in cement content as per design mix formula, nothing extra shall be admissible and quoted rates are deemed to include for the same.
Material and labour for preparation of newly plastered surfaces of wall and applying two coats of cement based paint, complete all as specified and directed.
Supply and fixing Vitreous china wash hand basin, white, flat back, size 550mm x 400mm, including brackets and cutting for and pinning in ends of brackets, complete including CP brass waste coupling, PVC waste pipe, brackets, complete all as specified.
Supply and fixing pillar tap long neck, cast copper alloy, chromium plated, fancy type, with capstan head, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shank and fly nuts, screwed for iron pipe 15mm bore dia and fixed to WHB and connections to iron pipe, complete all as specified and directed.
Supply and fixing galvanized steel water tubes 15mm bore, medium grade, with all standard fittings such as bends, elbows, tees etc, concealed/on surface, fixed to walls and ceiling or laid in floors, including cutting chases and making good, complete all as specified and directed.
Supply and fixing galvanized steel water tubes 20 mm bore, medium grade, with all standard fittings such as bends, elbows, tees etc, concealed/on surface, fixed to walls and ceiling or laid in floors, including cutting chases and making good, complete all as specified and directed.
Material and labour for precast cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in manhole covers, chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including necessary formwork, complete all as specified and directed.
Supply and fixing galvanized steel water tubes 100 mm bore, medium grade, with all standard fittings such as bends, elbows, tees etc, concealed/on surface, fixed to walls and ceiling or laid in floors, including cutting chases and making good, complete all as specified and directed.
Supply and fixing stop valve, cast copper alloy, chromium plated, screwed down high pressure, screwed for iron pipe or for brass ferrule 15mm bore dia, complete all as specified and directed.
Supply and fixing/hoisting, rotational moulded polyethylene (HDPE) water storage tanks (cylindrical vertical with closed top), 500 litres capacity ‘triple layered’, hoisted and fixed in position including inlet, outlet and drain pipe with plug, complete all as specified and directed.
Supply and fixing 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or brass ferrule complete all as specified and directed.
Supply and fixing 20 mm bore Gun metal, globe or gate valve,with iron wheel head, screwed both ends for iron pipes complete as specified and directed.
Supply and fixing 110 mm dia bore PVC (SWR) pipes, single socketed, in any length, with rubber ring joints,laid in trenches or in floors, complete all as specified and directed.
Supply and fixing 110mm bore PVC (SWR) bends any radius, fixed to pipes with adhesive, complete all as specified and directed.
Supply and fixing grating doom PTMT 100 dia with waste holes (minimum weight 40 grams) , complete all as specified and directed.
Material and labour for 100 mm thick plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base of floors, complete all as specified and directed.
Supply and fixing Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240, complete all as specified and directed.
Supply and fixing Factory made box type steel window with pintol hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded, including provision of grill as per drawing and with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEAF/STD-184-2012 Sheets 1/3, 2/3 & 3/3.
Supply and fixing plain sheet glass 4 mm thick, ordinary quality, not exceeding 0.50 Sqm each pane, and glazing with oil putty and securing pins, complete all as specified and directed.
Material and labour, applying two coats of synthetic enamel paint on new steel surfaces over 10cm width or girth, including preparation of steel surface, complete all as specified and directed.
Taking down cement plaster of any description on brick walls or concrete surfaces etc, including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
Material and labour for cutting into existing manhole for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished and reforming benching as required, complete all as specified and directed.
Material and labour for cutting chases, pinning in, making good to facing where required and pointing in cement morter 1:3 to ends or edges of landings, steps, cills sunshades shelves, lintels etc, and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10 cm girth, complete all as specifird and directed.
ROAD PATH AND CULVERT WORKS
Rolling and consolidating formation surfaces in cutting with animal roller 8 to10 tonne roller including watering as necessary, filling in hollows and depressions and consolidating to the required level, gradient and camber complete all as specified.
Material and labour for 100 mm thick plain cement concrete 1:5:10 type E-2 using 40mm graded crushed stone aggregate as in sub base of floors, complete all as specified and directed.
Material and labour for 25 mm thick sand filling under floor incl watering and consolidation complete all as specified.
Material and labour for Factory Made machine pressed precast concrete interlocking paver block with grey cement and no pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade complete all as specified and directed.
Material and labour for Bricks, sub class B, laid on edge, in floors, old size bricks, jointed in cement mortar 1:6 and pointed in cement mortar 1:3 complete all as specified and directed.
Material and labour for cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in surface channels and drains, complete all as specified and directed by the Engineer-in-Charge.
Material and labour for flush pointing to brick walls or to bricks on edge in floors, surface channels, roofs, in cement mortar 1:3, complete all as specified and directed.
Material and labour for ready mixed concrete (RMC) pavement quality concrete (PQC) as per design mix (as per IRC 44 specifications) using graded crushed stone aggregate, having minimum field flexural strength of 40 Kg/Sq cm in pavement, ( min cement content shall be 400 Kg / cum using OPC 43 gde) and super-plastisizer, if required, laid to level, gradient and camber, spread, paved, campacted & finished including belting & brooming complete all as specified and directed. Note:- (i) In the event of increase in cement content as per design mix formula, nothing extra shall be admissible and quoted rates are deemed to include for the same. (iii) All expansion joints to be deducted and all dummy/construction joints to be considered for measurement purpose.
Material and labour for forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade ‘A’ for thickness of slab 150 mm, by using diamond cutter for cutting of joint, complete all as specified and directed.
Material and labour for forming contraction (dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound Grade ‘A’ for thickness of slab 150 mm, by using diamond cutter for cutting of joint, complete all as specified and directed.
Material and Labour for Reinforced concrete pipes, 300 mm bore, class NP- 3, laid and jointed complete with and including collars laid in trenches at any depth, jointing and testing complete, all as specified and directed.
Material and Labour for Plain cement concrete 1:3:6, type C-2, using 40 mm graded stone aggregates as in concrete bed to drain pipes laid to falls in trenches in any depth including complete encasing the pipes for 300 mm bore drain pipes after the pipes are laid and tested complete, all as specified and directed.
Material and Labour for laying 100 micron thick polythene sheet including side and end laps complete, all as specified and directed.
Demolition of cement concrete in ground floors and pavings exc 15 cm thickness (below or above ground level), comp[lete all as specified and as directed.
INTERNAL ELECRIFICATION WORKS
Material and labour for point wiring with single core multi stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed FRLS colour code cable of 1100volts grade drawn through and including non metalic rigid PVC conduit medium duty of suitable size with all standard fittings such as Tee junction, bends etc, concealed in wall/fixed on ceiling including M.S. sunken boxes of suitable size made of 1.6mm thick MS sheet duly painted with anticorrosive paint, for housing switches, fan regulators etc. with PVC cover sheet 3mm thick (Make : Hylam, Plaza, Havells, Kalinga) including 1.5Sqmm (nominal area) multi stranded copper conductor PVC insulated unsheathed FRLS colour code cable of 1100volts grade for earth continuity, as for one light/exhaust fan/bell point or fan point (through regulator), controlled by one switch, complete all as specified and directed. Note(s) : (i) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required. (ii) Switches and fan regulator etc., shall be measured and paid separately.
All as per item No 3.01 here-in-before but for 2/3 pin socket outlet 5 Amps multipurpose on same board with other switches.
All as per item No 3.01 here-in-before but for 3/5 pin socket outlet 5 Amps multipurpose on independent board.
Material and labour, point wiring complete with two single core multi stranded Copper conductor of size 2.5 Sqmm (nominal area) FRLS PVC insulated unsheathed 1100 volt grade colour code cable, drawn in and including non metalic rigid PVC conduit medium grade of suitable size including standard fittings such as Tee junction, bends etc, conduit concealed in wall & fixed on ceiling including M.S. sunken boxes of suitable size made out of 1.6 mm thick sheet duly painted with anticorrosive paint for housing switches, sockets etc, with PVC cover sheet 3mm thick (Make : Hylam, Plaza, Havells, Kalinga) including one 2.5Sqmm size (nominal area) multi stranded copper conductor FRLS PVC insulated unsheathed colour code cable for earth continuity, for one multi purpose socket outlet 6 pin, 15Amps & 5Amps on independent board, complete all as specified and directed. Note(s) : (i) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required. (ii) Switches etc. shall be measured and paid separately. Circuit wiring from distribution board to switch board shall be deemed included in the quoted rate of point wiring.
Supply and fixing switch piano, flush type, single pole, one way, 6Amp, 230volts, complete all as specified and directed.
Supply and fixing switch piano, flush type, single pole, one way, 16Amp, 230volts, complete all as specified and directed.
Supply and fixing socket outlet, flush type, 2 in 1, multi purpose, 5 pin, 6Amps, 230 volts, complete all as specified and directed.
Supply and fixing socket outlet, flush type, 2 in 1, multi purpose 6 pin, 6Amps & 16Amps, 230 volts, complete all as specified and directed.
Supply and fixing ceiling rose, surface bakelite, polycarbonate / PVC isolated body, 65mmx50mm, two to three terminals, (ISI marked), complete all as specified and directed.
Supply and fixing LED flood light fitting, pressure die cast aluminium compact high power, powder quoted, with heat resistant toughened glass, 120 watt, 230 V AC, outdoor type, with thermal management in multiple optics and equipped with IP-66 protection, with impact resistance of IK07, 10 KV built-in surge protection and corrosion resistant complete with driver and lamp, complete all as specified and directed.
Supply and fixing LED flood light fitting, pressure die cast aluminium compact high power, powder quoted, with heat resistant toughened glass, 100 watt, 230 V AC, outdoor type, with thermal management in multiple optics and equipped with IP-66 protection, with impact resistance of IK07, 10 KV built-in surge protection and corrosion resistant complete with driver and lamp, complete all as specified and directed.
Material and Labour for wiring for curcuit/submain alongwith earth wire in PVC conduit with 2x1.5 sq. mm conducter + 1x1.5 sq. mm earth wire, FR PVC insulated copper conductor, single core cable in surface/recessed as required, complete all as specified and directed.
Supply and fixing Rigid non-metalic PVC conduit inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, complete all as specified and directed.
REFRIGERATION AND AIR CONDITIONING WORKS
Supply, installation, testing and commissioning, High wall split type AC unit of capacity 1.5 TR star rating with EER 3.2, electic driven, single phase, indoor and outdoor unit, with cordless remote control and with in-built air ionizer and plasma filter for better indoor air quality, necessary suction and discharge copper pipelines from inner units superior quality for drainage of condensed water, including suitable stand for mounting outdoor unit as per manufacturer's instructions and electrical connections and electirc cable from inner to outer unit, complete all as speicfied and directed.
Supply and installation for automatic voltage stablizer of capacity 5 KVA. single phase 230 volt naturally air cooled indoor type and designed for input variation between 170 V to 250 V (Copper Winding) with output voltage stablized at 230 V with accuracy of + 2.5%, complete all as speicfied and directed.
Material and labour for Sub Main Wiring with two single core 4 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including non-metalic rigid PVC conduit, heavy duty of 25 mm dia, including standard fittings such as Tees, junction, bands etc., conduit concealed in wall & fixed on ceiling with suitable clamps with and including one run of continuous multi stranded copper conductor 4 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 4 Sqmm main cable + one run of 4 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre. (ii) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required.
Supply and fixing in replacement sheet metal enclosure, SPN, with a two pin socket and earth plug, with one MCB single pole, 240 Volts, 20 Amps, complete all as specified and directed.
EXTERNAL ELECTRIFICATION WORKS
Dismantling RCC foundation of existing lighting arrestor, including taking down all fittings and fixtures like G.I pole mast of up to 10 mtrs height, 50mm dia, adaptor with the ESE Air Terminal, supporting guy wires, lightning striker, Test link, Earth strip/wire etc and refixing the same at new location, including making new foundation of size 60cm x 60cm x 60cm in cement concrete 1:2:4 type B-1 and necessary earth work, complete all as specified and directed by Engineer-in-Charge.
Material and labour for providing earthing of advance chemical earthing system of Copper pipe Chemrode 3 mtrs long 50mm dia filled with highly conducting metallic compounds with the permanent sealings at both the ends. Top of the earth electrode shall be compressed to form an extended lead with 2 holes for connecting the strip/wire to the load. To ensure the moisture content and electrical conductivity, each earthing pit shall be provided with minimum 02 bags of 20 kgs chemical compound. An arrangement for connection of copper strip (25x3mm) to rod to be made with given Terminal point with SS Nut Bolts, provision of polymer chamber with cover, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil complete all as specified and as directed Make : JK CHEM RODE / LPI /Alltec/Akaltech. Note(s) :- The qouted rates shall deem to include the following:- (i) Pit cover chamber of polymer chamber with cover, including necessary excavation in any type of soil. (ii) Copper strip with necessary brazing and GI protection pipe upto a length of 7.5m, Length beyond 7.5m required at site shall be measured and paid separately (iii) Earth resistance shall be less than 1Ohm. In case the test results are not found below 1Ohm, complete earthing will be redone without any extra cost to Govt. (iv) For effective visibility identification and traceability of earth pit (EP) with corresponding earth of eqpt and bldg, markers in metal (Mild Steel) shall be provided. Earth test of earth pit shall be provided with a colour code. The direction regarding the size, shape and colour of the Mild steel identification board etc., shall be given by the Engineer-in-Charge. (v) All joints of strip are to be brazed on both sides (over lapping) except test point.
Supply and fixing single core PVC insulated copper cable 70 Sqmm in suitable PVC conduit including all necessary fixing arrangement. Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing copper earth strip of size 32x6 mm on wall and floor complete all as specified.
Supply and fixing porcelain supporting insulator as required at site, fixing on wall/roof for supporting the lightning arrester earthing strips, including Nut Bolts and Washers, complete all as specified and directed.
Material and labour for Brazing on Copper earth strip of size up to 32 mm x 6 mm on wall and floor or as per site requirement, including necessary cleaning of earth strip before applied brazing complete all as specified and directed.
Supply and fixing hot dipped galvanised/powder coated cable tray, ladder type 600 mm x 50 mm x 2.5 mm including all fittings and accessories, complete all as specified and directed.
Supply and fixing GI hot dipped powder coated coupler 100 mm height for GI hot dipped poweder coated ladder type cable tray of size 600 mm complete all as specified and directed.
Supply and fixing hot dipped galvanised/powder coated cable tray, perforated type 150 mm x 50 mm x1.6mm including all fittings and accessories complete all as specified and directed.
Supply and fixing hot dipped galvanised/powder coated cable tray, perforated type 300 mmx50 mmx2 mm including all fittings and accessories complete all as specified and directed.
Supply and fixing hot dipped galvanised/powder coated cable tray cover suitable for perforated type tray 150 mm x 50mm, including all fittings and accessories complete all as specified and directed.
Supply and fixing hot dipped galvanised/powder coated cable tray cover suitable for perforated type tray 300 mm x 50 mm including all fittings and accessories complete all as specified and directed.
Supply and fixing GI hot dipped powder coated coupler 25/30 mm height for GI hot dipped poweder coated perforated type cable tray of size 150 mm/300 mm, complete all as specified and directed.
Supply, laying (in replacement), jointing, testing and commissioning Low Tension (LT) XLPE insulated and armoured, heavy duty, electric power cable, cross sectional area 35 Sqmm 3.5 core aluminum conductor 1100 volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: Excavation & earthork, sand cushioning and bricks for protection of cable shall be measured and paid separately.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick after laying of cables (punned down to 180mm thick), in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Material and labour, locally available, sub class `B’ bricks (old size), laid flat and dry perpendicular to the direction of cable adjacent to each other, in trenches over the cable for protection, complete all as specified and directed.
Supply and laying / fixing , GI pipe light grade 40 mm bore for cable protection fixed to pole/wall or laid under floor/road/pavement,including MS clamps,nut,bolts etc, complete all as specified and directed.
Material and labour for vertical type MS sheet metal enclosure distribution boards, double door, factory made 3 phase 415 volts 4 way with 200 amps rating copper bus bar of suitable size and PVC insulated copper jumpers from the MCCB to the out going circuits (one incoming MCCB and 12 outgoing MCBs circuits) comprising of 3 phase 4 wire of suitable rating including MCCB 160 amps, 25 KA, TP 415 volts, 50 Hz= 01 No and 12 Nos MCBs 6-32 Amps, complete all as specified and directed.
Material and labour for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron strip of size 32 mmx6 mm thick (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20mm dia bore GI medium grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.
Supply and fixing/erecting in true vertical position, steel tubular pole, swaged, type 410-SP-31 (9.00 metres long), complete with cast iron base plate of size 300mmx300mm, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paint to portion embedded in PCC including painting the pole with alternate black and yellow paint strip band 30cm long 5 Nos with synthetic enameled paint and numbering of poles with paint, complete all as specified and directed. Note : Earth work and PCC shall be measured and paid separately.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, including GI bracket made out of 40 mm dia GI pipe medium grade 1.2 mtr bent to shape and fixing on walls/poles with MS clamps of suitable sizes complete complete all as specified and directed by Engineer-in-charge.
Supply and fixing single core PVC insulated copper cable 70 Sqmm in suitable PVC conduit including all necessary fixing arrangement. Complete all as specified and directed by Engineer-in-Charge.
Material and labour for mild steel as in framed work of doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing similar work conforming to Fe-290 Grade E-165, complete all as specified and directed.
Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75 mmx75 mm x25mm drilled and screwed including 3 Nos, 8 mm dia 25 mm long hexagonal head screw, complete all as specified and directed.
Supply and fixing outdoor type, factory made cable junction box dust, weather and vermin proof, IP-65 protection, with aluminium bus bar strip 25 mmx3 mm and MCB 6 Amps, 10KA, 'C' curve, MS strip of size 25 mmx4 mm, including MS clamps, bolts, Thimbles etc for fixing arrangement for each street light, including cable gland and locking arrangements, complete all as specified and directed.
Supply and fixing street light junction box, insulated, made of polycarbonate with glass fiber reinforced, with suitable bus bar-100 Amps and 20 Amps MCB, complete all as specified and directed, Make - Cat part No 2525 of Hensel or equivalent in Semen/GE Power.
EXTERNAL WATER SUPPLY
Supply and fixing Steel water tubes, galvanised, medium grade, ISI marked, 50 mm bore with and including all fittings and fixed complete to wall or laid in trenches complete all as specified and directed.
Supply and fixing Steel water tubes, galvanised, medium grade, ISI marked, 40 mm bore with and including all fittings and fixed complete to wall or laid in trenches complete all as specified and directed.
Supply and fixing Steel water tubes, galvanised, medium grade, ISI marked, 25 mm bore with and including all fittings and fixed complete to wall or laid in trenches complete all as specified and directed.
Supply and fixing Steel water tubes, galvanised, medium grade, ISI marked, 20 mm bore with and including all fittings and fixed complete to wall or laid in trenches complete all as specified and directed.
Supply and fixing Gun-metal globe or gate valves, half turn, screwed down, high pressure,heavy duty, ISI marked , with MS handle, screwed both ends for iron pipe or for unions of 50 mm bore dia, complete all as specified and directed.
Supply and fixing Gun-metal globe or gate valves, half turn, screwed down, high pressure,heavy duty, ISI marked , with MS handle, screwed both ends for iron pipe or for unions of 40 mm bore dia, complete all as specified and directed.
Supply and fixing Gun-metal globe or gate valves, half turn, screwed down, high pressure,heavy duty, ISI marked , with MS handle, screwed both ends for iron pipe or for unions of 25 mm bore dia, complete all as specified and directed.
Supply and fixing Gun-metal globe or gate valves, half turn, screwed down, high pressure,heavy duty, ISI marked , with MS handle, screwed both ends for iron pipe or for unions of 22 mm bore dia, complete all as specified and directed.
Material and Labour for drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 20 mm, including supply and fixing brass ferrule for branch connection, complete all as specified and directed.
Cutting existing steel tubing for alteration or addition 20 mm dia GI Pipe (each cut measured)
MISCELLANEOUS ITEMS PERTAINING TO BUILDING WORK, ROAD PATH AND CULVERT WORKS, INTERNAL ELECRIFICATION WORKS,REFERIGERATION AND AIRCONDITIONING WORKS, EXTERNAL ELECTRIFICATION WORKS, EXTERNAL WATER SUPPLY WORKS
Surface dressing in soft/loose soil not exceeding 15 Cm deep, getting out and removal of soil/rubbish etc not exceeding 50 metres complete all as specified and directed.
Rough excavation not exceeding 1.5 m deep and getting out in soft/loose soil, complete all as specified.
Surface excavation in soft/loose soil not exceeding 30 Cm deep and averaging 15 Cm and getting out complete, all as specified.
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.5 metre in depth; for foundations etc or for cesspits, manholes,not exceeding 10 Sqm on plan, trimming or for laying/taking out cables/pipes and foundations of poles, etc and getting out complete, all as specified.
Exacavation in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Material and labour for plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete, complete all as specified and directed.
Material and Labour for PCC (1:2:4) type B-1, using 20mm graded crushed stone aggregates, as in coping, roof kerb, hold fast blocks, mud stops, kneelers, apex stones, bed plates,benching, water trough etc including weathering, slightly rounded or chamfered angle and throating, including necessary form work, complete all as specified and directed.
Material and labour for plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete/ sub base, complete all as specified and directed.
Material and labour for brickwork in half brick thick wall using subclass 'B' old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:4), complete all as specified and directed.
Material and labour for 100 mm thick plain cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregates as in floor, finished the surface even & smooth using extra cement, including provision of necessary dummy joints, complete all as specified and directed.
Material and labour, applying two coats of synthetic enamel paint over and including a coat of red oxide primer, on new steel surfaces over 10cm width or girth, including preparation of steel surface, complete all as specified and directed.
Material and labour for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron wire 4mm dia (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20mm dia bore GI medium grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete including dismantling of existing earthing all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.
G M BUILDERS 36
MAAN ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .