Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC STATION ROAD P O UKHRA DIST BURDWAN PIN 713363 W B | UKHRA | BURDWAN | WEST BENGAL | 713363 | ₹3.8 L | L1 | Accepted-AOC TC recommendation |
| 2 | L2₹3.8 LRejected-Finance 59 R G S ROAD USHAGRAM DURGAMANDIR ASANSOL BARDHAMAN 713303 WEST BENGAL INDIA | ASANSOL | BARDHAMAN | WEST BENGAL | 713303 | ₹3.8 L | L2 | Rejected-Finance TC recommendation |
| 3 | Rejected-Technical BARDHAMAN BARDHAMAN 713363 WEST BENGAL INDIA | BARDHAMAN | BARDHAMAN | WEST BENGAL | 713363 | - | - | Rejected-Technical TC recommendation |
| Sl No | Description | Qty | Unit | ROY ENTERPRISE L2 | ANNAPURNA ENTERPRISE L1 |
|---|---|---|---|---|---|
| 1.00Work description | |||||
| 2.00 | Installation of NGR in GEC make 3.3KV/550V TSU along with repairing of Primary switch gear installed at 17/18Drift 21Level (Sl.No.D1123244) Introduction of restricted neutral system NGR with requiring spares | 1 | set | 75,000 ₹75,000 | 74,400 ₹74,400 |
| 3.00 | Supply and fixing of shunt trip coil assembly complete with trip coil etc. | 1 | set | 3,700 ₹3,700 | 3,650 ₹3,650 |
| 4.00 | Supply and fixing of Micro switch (Test-reset) | 2 | nos | 450 ₹900 | 400 ₹800 |
| 5.00 | 110Volt auxillary circuit wiring with 2.55qmm multistrand copper wire, lugs, ferrule etc. | 1 | ls | 6,800 ₹6,800 | 6,500 ₹6,500 |
| 6.00 | Unit portion cleaning and re-insulating with HT grade varnish etc. | 1 | ls | 3,500 ₹3,500 | 3,200 ₹3,200 |
| 7.00 | Repairing of closing and tripping mechanism | 1 | set | 12,700 ₹12,700 | 12,800 ₹12,800 |
| 8.00 | Labour charges for assembling, fitting, testing etc. | 1 | ls | 6,200 ₹6,200 | 6,000 ₹6,000 |
| 9.00 | Fabrication of M.S. Box | 1 | nos | 3,900 ₹3,900 | 4,000 ₹4,000 |
| 10.00 | B) Installation of NGR in GEC make 3154KVA 3.3KV/550Volt TKSU along with repairing c switch gear installed at 5Drift 17Rise (Sl.No. 371078/1) Introduction of restricted neutral system NGR with requiring spares | 1 | set | 75,000 ₹75,000 | 74,400 ₹74,400 |
Tender Value
₹3.8 L
EMD Value
₹4,800
Closing Date
13 Mar 2026, 6:00 pmClosed
General Manager Bankola Area
Office of The General Manager Bankola Area, PIN-713363
Installation, testing and commissioning of restricted neutral system NGR at Millennium Incline underground with necessary repairing of the switch gear under Shankarpur Colliery.
2026_ECL_355415_1
ECL/GM/BA/E TENDER/25-26/ENM/326 Dt 03.03.2026
Open Tender
Electrical and Maintenance Works
15 days
Shankarpur Colliery
Please refer to NIT document
5 documents required · 5 mandatory
₹4,800
10 Apr 2026
3 Mar 2026
14 Mar 2026
3 Mar 2026
13 Mar 2026
3 Mar 2026
3 Mar 2026 - 7 Mar 2026
Work description
Installation of NGR in GEC make 3.3KV/550V TSU along with repairing of Primary switch gear installed at 17/18Drift 21Level (Sl.No.D1123244) Introduction of restricted neutral system NGR with requiring spares
Supply and fixing of shunt trip coil assembly complete with trip coil etc.
Supply and fixing of Micro switch (Test-reset)
110Volt auxillary circuit wiring with 2.55qmm multistrand copper wire, lugs, ferrule etc.
Unit portion cleaning and re-insulating with HT grade varnish etc.
Repairing of closing and tripping mechanism
Labour charges for assembling, fitting, testing etc.
Fabrication of M.S. Box
B) Installation of NGR in GEC make 3154KVA 3.3KV/550Volt TKSU along with repairing c switch gear installed at 5Drift 17Rise (Sl.No. 371078/1) Introduction of restricted neutral system NGR with requiring spares
Supply and tixing of shunt trip coil assembly complete with trip coll etc.
110Volt auxiliary circuit wiring with 2.55qmm multistrand copper wire, lugs, ferrule etc.
Unit portion cleaning and re-insulating with HT grade varnish etc.
Repairing of closing and tripping mechanism
Labour charges for assembling, fitting, testing etc.
Fabrication of M.5. Box
( C)Installation of NGR in Andrewyule make 315KVA 3.3KV/550V TSU SL.No.TSU/M/03 Inst R 30Drift Introduction of restricted neutral system NGR with requiring spares
Supply and fixing of shunt trip coil assembly complete with trip coil etc.
Supply and fixing of Micro switch (Test-reset)
110Volt auxiliary circują wiring with 2.55qmm multistrand copper wire, fugs, ferrule etc..
Unit portion cleaning and re-insulating with HT grade varnish etc.
Labour charges for assembling, fitting, testing etc.
Fabrication of M.S. Box
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_368257.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.65 MB
Tendernotice_2.pdf
PDF • 1.04 MB
Tendernotice_3.pdf
PDF • 0.22 MB
BOQ_368257.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid