Loading…
Loading…
Tender ID
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
6 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
120 days
Expenditure
Capital (Works)
PSI WORK
2 conditions · 2 needing a document upload
1.Submission of audited balance sheets for the last five financial years to demonstrate the current soundness of the Bidders financial position. As a minimum criteria, Profit Before Tax (PBT) should be positive for two financial years out of last five financial years 2.construction turnover for the last three years should be 150% of the estimated value put to tender. 3.FIN-1 and FIN-2 to be submitted ( Click here to download Format)
1.(I)1 Specific Construction Experience : Execution as contractor, or subcontractor, at least One contract that has been successfully or is substantially completed within the last Seven years before the deadline for submission of the bids, and that is similar to the proposed work. The similar work here shall be that which includes at least any one of the quantities of key activities mentioned below: i.Installation, testing and charging of 25 KV and above PSI system charged at 2.2KV/25KV or above on railway track of minimum Value of (0.35V) (where V= Value of work requirement)through single contract. OR (II) Execution as contractor, or subcontractor, at least Two contracts, each that have been successfully or are substantially completed within the last Seven years before the deadline for the submission of the bids, and that are similar to the proposed work. Each similar work here shall be that which includes at least any one of the quantities of key activities mentioned below: i.Installation, testing and charging of 25 KV or above PSI system charged at 2.2KV/25KV or above on railway track of minimum value of (0.2V) (where V= Value of work requirement)through each contract. 2.Construction Experience in Key Activities : i. Installation, testing and charging of 25 KV or above PSI system charged at 2.2KV/25KV or above on railway track of minimum value of (0.6V/T) (where V= Value of work requirement and T is completion period in years) in one year . 3.Must have valid Electrical Contractor "A" Grade license from the appropriate authority,Exp 2(a)&2(b) to be submitted ( Click here to download Format)
2 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
EACH BIDDER SHOULD SUBMIT DETAILS/REFERENCES AS TO HOW THE ELIGIBILITY CRITERIA IS BEING MET BY THE BIDDER AGAINST EACH ITEM OF EQC. THIS SHOULD BE PREPARED AND SUBMITTED IN THE PERFORMA "EQC FORM NO.1" ENCLOSED IN SECTION 4.
Provision of SSP & PSI Modifications works at Railway Manufacturing Unit (RMU), Kazipet of Secunderabad Division, South Central Railway
RVNL-SC-RMU-KZJ-PSI-OT-28
RVNL-SC-RMU-KZJ-PSI-OT-28
Open
Works - General
6 Months
New Delhi, Delhi
₹0
₹3.2 L
6 Mar 2026
13 Feb 2026
28 Feb 2026
106 items across 10 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,83,625 | ||
| — | 1.00 | — | — | ||
| Supply and Erection of Terminal boards in control cubicles Supply | — | — | — | 13,015 | |
| — | 1.00 | — | — | ||
| Supply and Erection of Terminal boards in control cubicles Erection | — | — | — | 585 | |
| — | 1.00 | — | — | ||
| Supply and Erection of iron clad 240V AC and 110V D.C. board with fuse box in control cubicles Supply | — | — | — | 8,628 | |
| — | 1.00 | — | — | ||
| Supply and Erection of iron clad 240V AC and 110V D.C. board with fuse box in control cubicles Erection | — | — | — | 267 | |
| — | 1.00 | — | — | ||
| Supply, Erection, Testing and Commissioning of low maintenance Lead Acid Battery set 40 AH, 110 volts DC as per latest RDSO specifications including filling up of electrolyte and initial charging /discharging etc as required Supply | — | — | — | 87,606 | |
| — | 1.00 | — | — | ||
| Supply, Erection, Testing and Commissioning of low maintenance Lead Acid Battery set 40 AH, 110 volts DC as per latest RDSO specifications including filling up of electrolyte and initial charging /discharging etc as required Erection | — | — | — | 6,286 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ALLMANDATORYSBDBIDDOCUMENTS.pdf ALL MANDATORY SBD BID DOCUMENTS
ATTACHMENT
ALLMANDATORYSBDBIDDOCUMENTS.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .