Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 3 4 520 TO 526 FLAT NO 303 PRAGATHI PRIDE APARTMENT BARKATHPURA HYDERABAD 500027 | HYDERABAD | TELANGANA | 500027 | Admitted-Finance |
| 4 | Admitted-Finance H NO 13 186 1 B D L COLONY BADANG PET BALAPUR MDL HYDERABAD 500112 | HYDERABAD | TELANGANA | 500112 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹23 L
Closing Date
28 Sept 2022, 2:00 pmClosed
GDG Prasad Raju, Sc F, CCE
CCE (RnD) Estates South Chandrayangutta Hyderabad - 05
Special Repairs for Existing Buildings including Electrical, EOT Crane and Miscellaneous Works at Girola and Jagdalpur
2022_DRDO_710934_1
CCEESTS/ENQ/JPR/REPAIRS/ 38/2022-23
Limited
Civil Works
244 days
Girola, Jagdalpur
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
Yes
CCE (RnD) Estates South
₹23 L
Yes
13 Oct 2022
7 Sept 2022
29 Sept 2022
7 Sept 2022
28 Sept 2022
7 Sept 2022
Amount
SUBHEAD-I :REPAIRS TO TECHNICAL & NON TECHNICAL BUILDINGS
For Cracks & Seepages in Walls
Surface to be free from frost, surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish for application of waterproof coating prime the surface with water. Cut open of grooves (15 mm x 15 mm ) any voids and cracks to be filled up by means of “ V ” groove, using Renderoc CS for cracks less than 1.5 mm. Renderoc Sp 40 for cracks upto 15 mm cracks. Note : The methodology is to be followed as per manufacture specification or site conditions with respect to engineer
Drilling of holes and fixing of nozzles of 8/12mm dia (PVC) for carring out cement/Epoxy injection grouting and Fix and Close the nozzles with PVC/GI NRV Packers and Renderoc Plug including cost of labour, tools equipments etc complete as per the specification.
Carrying out cementitious pressure grouting with 40 psi pump using Cebex 100 @ 225gms mixed to 50 kg bag of cement including joints packing in the required consistency through the pre fixed PVC nozzles in the required dia holes, fixing of PVC nozzles with Renderoc Plug and final cutting the projected nozzles and sealing off the PVC nozzles after the injection operation is over with Renderoc plug, nonshrink rapid setting mortar compound, finishing, curing etc. as per manufacturers specification and as directed.
Providing and applying Fosroc Dekguard E 2000 water based primer + two coats of acrylic, breathable, elastomeric, water based, anti-carbonation coating to all concrete members above ground. Coating must be applied to achieve total dry film thickness of not less than 200 microns and shall have Carbon dioxide diffusion resistance equivalent air layer thickness (DIN EN 1062-6) > 50 m; Carbon dioxide diffusion resistance equivalent air layer thickness (Taywood Method) = 240 m; Carbon dioxide diffusion resistance equivalent thickness of 30N concrete (Taywood Method) >500 mm; Carbon dioxide diffusion resistance co-efficient (DIN EN 1062-6) > 7.50 X 10^5; Elongation of cured film shall be (ASTM D 412) > 200%; Chloride Ion Penetration (ASTM C 1202-03) = Very Low (100 to 1000 Coulombs); Tear Resistance (ASTM D 624) = 12 N/mm; Static Crack spanning capability (ASTM C 836-Modified) = 2mm; UV Resistance (ASTM D 4587,Condition E Cycle 1 from ASTM G154) > 500 Hours; Reduction in Water Absorption (ASTM C642) > 82%; Adhesion (ASTM D 4541) > 1 N/mm2 and Solar Reflectove Index of 105 amd emissivity > 93% as per ASTM E 1980, etc, complete. Product used shall have CE marking and compliance according to Construction Products Directive 89/106/EEC (CPD)
Supply and erection of necessary Scaffolding including arrangemnt of necessary working platform inluding cost of material, tools and labour etc. complete.
For Cracks Seepages and for Water Retains in RCC
Supply and application of polyurethene based injection grout by M/S Fosroc chemicals Nitofill WS60 which produces a rapid setting foam in the presence of running water. When the flow of water is stopped the cracks are reinjected with Fosroc Nitofill UR63. The surface of the crack must be sealed and injection nipples bonded in place before Nitofill UR63 is injected using polyester resin grout Renderoc Plug. The PU grout should have a pot life of 20 minutes at 35°C and a velocity of 3 poise. Product used shall have CE marking and compliance according to Construction Products Directive 89/106/EEC (CPD), including cost of material, labour, tools etc as per the Spectification. Note : This product to be used for celing,soffit,slabs areas where it is having cracks.White leaching spots to be treated from bottom as identified at site.
For Strengthing of Existing RCC Structures
Supply and grouting of epoxy resin Conbextra EP10 in all the honey comb & cracked surfaces. Mixing and injection of grout using mechanical grouting pumps and with GI NRV packers for epoxy grouting. Note For Strengthing of Existing RCC structures
Cutting of Existing hooks, drilling upto a depth of 500mm and fixing the new anchorages of required shape and size, using Fosroc Nitomorar Plug a polyester resin grout including cost of labour, material, equipment etc. as per specification.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m : All Kinds of soils
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
SUBHEAD-I :EARTH WORK & EXCAVATION
Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge.
Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).
Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge.
20 mm cement plaster of mix including gatty of required dia pipe:1:6 (1 cement: 6 coarse sand).
Surface preparation the existing paint, surface contaminations, fungus and other micro organism growth shall be removed by mechanical means. All the cracks has to be cleaned properly & the same has to be filled with modified styrene butadiene rubber emulsion slurry by mixing 1 volume of Nitobond SBR to 1 volume of clean water to 3 volumes of fresh cement mixed with Fosroc Nitobond SBR Latex,as per manufacturers specification and as directed. Note : Hair line Cracks Surfaces.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and applying external weather shield paint of any approved brand as indicated in technical specifications document or any equivalent including surface preparation with base coat of primer and two coats of the painting etc complete at all heights and locations as per specifications and as directed by Engineer - in - Charge. Note : Camouflage type painting to be done for compound wall
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size of thickness upto 10mm and 300x300 mm of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete all as directed by Engineer - in - Charge.
Dismantling W.C. Pan/ wash basins/ uriner's pan of all sizes including all accessories disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
PLUMBING
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : a) W.C pan with ISI Marked white solid plastic seat and lid
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing toilet paper holder : C.P. brass
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. a) 15 mm nominal dia
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : a) Rectangular shape 1500x450 mm
Providing and fixing soap Dish Holder having length of 138mm, breath 102mm, height of 75mm with concealed fitting arrangements weighing not less than 106 gms
Providing and fixing liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia
Providing and fixing extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 75 gms
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing stop cock of approved quality and colour. Concealed stop cock, 15 mm nominal bore, 108 mm long, weighing not less than 108 gms
Providing and fixing Water Geyser of 15Liters of approved Quality and colour. (Elena Digital @ 15Liters Capacity of Jaguar or Equvalant)
Providing and fixing of two way bib cock with wall flange including 1.0mts long easy flex tube with end nuts and hook and health faucet all complete. Hook to be fixed with Cp brass with suitable counter sunk screws, all of approved make etc., cmplete two way bib cock model .
Providing and fixing TUMBLER HOLDER of approved quality and colour.
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
Providing and fixing Stainless Steel towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
FABRICATION
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to anypitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick flat
Providing and fixing bolts including nuts and washers upto 300mm in height complete.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
INTERNAL ELECTRIFICATION
Point Wiring for Light/ Fan/ exhaust fan/call bell point with single core 1100V grade 1.5 Sq.mm PVC insulated multistrand flexible , HRFR , Copper conductor wires , run in and including 25mm dia heavy gauge PVC conduits surface/recess , concealed in wall / ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends elbows and anodised GI Switch box with modular switch and the box covered with front plate including connections to Earth terminal.
One Light point controlled by one 6 A one way switch.
Two Light point controlled by one 6 A two way switch.
Two Light point controlled by one 6 A one way switch.
Exhaust fan point controlled by one 6 A one way switch.
Call bell point controlled by one 6 A bell push one way switch and buzzer
Wiring for Ceiling Fan point with single core 1100V grade 1.5 Sq.mm PVC insulated multistrand flexible , HRFR , Copper conductor wires , run in and including 25mm dia heavy gauge PVC conduits surface/recess , concealed in wall / ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends elbows and anodised GI Switch box with modular switch and the box covered with front plate including connections to Earth terminal.
Supply and fixing of 6A, 3Pin Socket outlet with 6A switch in Lighting switch boards. ( Dependant )
Supply and fixing of 6A, 3Pin Socket outlet with switch of 6A rating with wiring of 2 Runs of 2.5 Sqmm and 1 Run of 1.5 Sqmm FRLS, PVC insulated multistranded Copper conductor wires run in and including 25 mm Dia, 2 mm thick PVC conduit.(Independant).
Supply and Wiring with the following size 1100V grade PVC insulated multistrand FRLS Copper conductor wires in and including suitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories such as junction boxes, bends, elbows including end terminated with suitable lugs.
2 runs of 2.5 Sq.mm wires with 1run of 2.5 Sq.mm wire in and including 25 mm Dia PVC Conduit (For Lighting Circuit )
4 runs of 6 Sq.mm wires with 2 runS of 6 Sq.mm wires in and including 32 mm Dia PVC Conduit (For Lighting Sub Mains )
Supply and Installation of following type Fluorescent/ Compact fluorescent light fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall be supplied with lamps. The Catalogue Numbers refers to Philips Make.
22W LED Tube light fixture (Philips Cat No :BN 021C LED25S- PSU CDL SMART BRITE EXTRA LED with 2500Lm output or its Equivalent fixture )
Slim 12 W LED round surface mounted Luminaire (Philips Cat ref : Astra Surface 65K LED )
Slim 18 W LED round surface mounted Luminaire (Philips Cat ref : Astra Surface 65K LED )
72W LED Street Light Fixture (Philips Cat No : BRP410 LEDCW072 MR FG S1PSU GR OR Its Equivalent )
Supply and fixing Angle holder along with supply of 14W LED Lamp . (Philips Cat No : LED BULB 14W E27CDL or Its Equivalent)
Supply and Fixing of 1200 mm sweep white colour Ceiling fan with standard down rod ( 600mm length down rod in false ceiling areas ) and all accessories Electrical connections but excluding supply of Fan regulator as required etc.
Supply and Installation of 225 mm sweep Exhaust fans with Metallic blades and MS gravity louvers including all accessories / Installation materials required. ( Make : Havells/Crompton Flux Air )
Supply Installation Testing and commissioning of TPN MCB Double door Distribution boards dust and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB /ELCB as per specifications and required capacity Neutral bar and Earth terminal complete as required and installed in flush with wall including all fixing materials required. MCBs shall conform to IS: 8828 and ELCB /RCCB shall conform to IS : 12640
6 Way TPN MCB DB( Horizontal type Non flame Proof) with 40A, 4 pole MCB with 100mA ELCB as incomer and 18 nos 6-25 A SPMCBs as outgoings (LDBs).
POWER WIRING
Supply Installation Testing and commissioning of TPN MCB Double door Distribution boards dust and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB /ELCB as per specifications and required capacity Neutral bar and Earth terminal complete as required and installed in flush with wall including all fixing materials required. MCBs shall conform to IS: 8828 and ELCB /RCCB shall conform to IS : 12640
6 Way TPN MCB DB with 63A,4Pole MCB with 100mA ELCB as incomer and 18 nos 16-25A SPMCBs as outgoings (PDBs).
8 Way TPN MCB DB with 63A,4Pole MCB with 100mA ELCB as incomer and 24 nos 16-25A SPMCBs as outgoings (PDBs).
MODULAR POWER SOCKETS
Supply,erection,testing and commissioning of the following switch sockets with anodised G.I. Box, front plate and fixing screws etc
6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch.
Supply and fixing of modular single phase 6/16A , 6 PIN Socket with front plate and anodized GI Box including all fixing accessories. ( For Geyser )
Supply and fixing of modular type single phase 16A Switch with indicating lamp with front plate and anodized GI Box including all fixing accessories. ( Shall be provided in toilet switch board )
Supply and fixing of factory made 20A, 1Ph,230V Industrial type Metalclad plug and socket with plug top & 20A ,C Curve SPMCB in MS box including all fixing accessories
Supplying and fixing 32A ,415V ,TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 32A C Curve ,TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testing and commissionining etc complete as required.
Supply,Installation and commissioning of following storage type water heaters with suitable heating element fixed on walls/columns with necessary bracket including of all installation materials ,fixing inlet/out let water pipes interconnections as required.
25 Ltrs Capacity ( Make : Havells monza EC Cat No : GHWAMFSIV025 OR ITS EQUIVALENT )
50 Ltrs Capacity ( Make : Havells monza EC Cat No : GHWAMFSIV050 OR ITS EQUIVALENT )
wiring
Supply and Wiring with the following size 650V grade PVC insulated multistrand, FRLS Copper conductor wires in and including suitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories such as junction boxes, bends, elbows including end terminated with suitable lugs.
2runs of 4Sq.mm wires with 1run of 4 Sq.mm wire in and including 25mm dia PVC Conduit(For 16A Sockets )
2runs of 6Sq.mm wires with 1run of 6 Sq.mm wire in and including 25mm dia PVC Conduit(For 16A Sockets )
4runs of 6Sq.mm wires with 2run of 4 Sq.mm wire in and including 25mm dia PVC Conduit(For 16A Sockets )
4runs of 10Sq.mm wires with 2run of 6 Sq.mm wire in and including 25mm dia PVC Conduit(For 16A Sockets )
EARTHING
Providing and fixing of maintenance free earthing which consists of 40mm Dia ,standrad length (as per Equipment Supplier ) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancing compound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete.
Supply and laying of following size strips including all necessary inter connections with earth station and equipments.
50 X5 mm Hot dip GI strip
SUBHEAD-III :REPAIRS TO WATER TREATMENT PLANT
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc., for Internal work - Exposed on wall
32 mm dia nominal bore
25 mm dia nominal bore
20 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : :
20 mm nominal bore
25 mm nominal bore
Conducting Geological survey in the respective are and submission of detail report. Drilling and developing of 1no of 150mm dia Boar Well DTII method in any type of soil, conducting yeild test as per V-Notch method and submission of yeild report including filling of filter media clamps, MS Cover etc., complete.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia
Providing HDPE pipe PE-63 grade (12.5kg/sq.cm) of 63mm Odmm dia for borewell.
Supply, erection, testing and commissioning of 3cum at 200mm head submersible pump set 3 Phase-415V. 50Hz, 7.5HP, 8satge, 2000rpm as approved by engineer incharge at site.
Conduction field test by 'V' notch method and submission of bore reports.
Supply, erection, testing & commissioning of 4Sqmm 3core copper cable flat water proof inside bore well and laid over ground suitable for submersil pump along with PVC conduit where required all complete.
Supply, & laying of 3 core 10sq.mm armoured PVC under ground cable with end temination including excavation of soil with protection, back fillingetc. Complete as per ISI specifications.
Suppy, fixing, tesing and commissioning of suitable size MS weather proof enamel paint coated outdoor type box with locking arrangement for fixing item for star delta starter panel ( Bore well) this Box Including fixing the box in PCC pedestal all complete as approved and as specified.
Suppy, fixing, tesing and commissioning of following size medium grade G.I Pipe comfirming to IS 1239 part-1 including excavation, back filling etc., for connecting to the submersible
(a) 50mm dia
(b) 40mm dia
Supply and Fixing MS Clamps with nut and bolt of size 50mm X 450mm
Supply and Fixing,teasting MS casing 4mm thick 200mm dia, 750mm beow ground level and 250mm above ground level with MS cap complete.
Supply and Erection of 65mm dia Non-return valve.
Supply, erection, testing & commissioning of heavy grade ISI marked GM valve of size 50mm dia.
Supply, erection, testing & commissioning of heavy grade ISI marked GM valve of size 25mm dia.
SUBHEAD-IV :PROVISION OF MISCELLANEOUS ELECTRICAL WORKS
Repairing of 33KV Current Transformer with all required accessories including Filteration of Transformer oil and top up of 45Litres Transformer oil.The scope includes supply and installation of clamps ,nuts and bolts etc complete.
Supply,Installation,Testing and commissioning of out door type 11KV Potential Transformer with all required accessories and filteration of Transformer oil with top up of 35 Litres of Transformer oil.The scope includes supply and installation of clamps and nut and bolts etc complete.
Supply and repairing of 11KV Current Transformer with all required accessories and filteration of Transformer oil with top up of 35 Litres of Transformer oil.
Supply and servicing and changing of defective spare parts for on Load Tap Changers for 33/11KV , 3 MVA Transformer
Supply and installation of Vaccum Interrupter for 800A VCB ( Part No : VS 12031 )
Supply and Installation of Tripping coil for 800A VCB
Supply and Installation of Closing coil for 800A VCB
Supply and Installation of Indoor resin Cast Single phase Single pole insulated earthed type Potential Transformer. 11KV/110V / Root 3 to be installaed in 11 KV existing Siemens Panel Incomer Feeder.
Supply Installation Testing and commissioning of 33KV, 630A , SF6 Circuit breaker to be mounted on G.I Structure including supply and installation of G.I.Structure ,fixing hardware etc complete. The CB shall be supplied with motorised/mechanical spring charging mechanism,Closing and tripping coil of 110V ,Indication Lamps and also including Bus bar fixing clamps. The scope also includes removal and handing over of the existing 11KV MOCB to the Department.
Supply Installation Testing and commissioning of 11KV, 400A SF 6 Circuit breaker to be mounted on G.I Structure including supply and installation of G.I.Structure ,fixing hardware etc complete. The CB shall be supplied with motorised/mechanical spring charging mechanism,Closing and tripping coil of 110V ,Indication Lamps and also including Bus bar fixing clampThe scope also includes removal and handing over of the existing 11KV MOCB to the Department.
Supply of Nickel Cadmium pocket plate battery of type 20KBH 185 P consisting of 1.2V, 20 Cells of 185AH capacity along with MS Rack and standrad accessories.
Supply,Installation,Testing and commissioning of 230V ,50Hz input class 110V DC ,5KVA Output float cum battery charger with suitable maintenance free lead acid batteries -VRLA for 110V ,150AH with necessary metering for input and output and protection.
Supply ,Installation,Testing and commissioning of the following rating capacitor banks for existing APFC Panels in existing sub stations.The scope also includes checking the panel and control wiring etc complete.
a) 50KVAR
b) 20KVAR
c) 10KVAR
Supply and Installation of 250A, 430V MCCB 3 Pole ,25KA ,Electromagnetic Short circuit and over current and earth fault protection relay
Supply and Installation of 400A, 430V MCCB 3 Pole , 50 KA ,Electromagnetic Short circuit and over current and earth fault protection relay
Supply and servicing and changing of defective spare parts for on load Tap Changers for 11 KV/430V,2MVA Transformer
Supply and Servicing and changing of defective spare parts for LT Incoming breaker 800A,430V ACB , Make : L & T
Supply and Servicing and changing of defective spare parts for LT Incoming breaker 1600A,430V ACB , Make : L & T
Supply and servicing and changing of defective spare parts for 250KVA Outdoor Transformer.
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V , 4 wire Free Standing Floor mounted MV panel made out of 14 SWG MS sheet after seven tankprocess and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves.The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certificate only. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. Each panel is to be provided with minimum of two numbers of spare Cubicles.
MAIN M.V.PANEL ( FOR 250 KVA OUTDOOR T/F)
Incomer
800 A, 50KA, TPN MCCB, hould be supplied with S/C, E/F, O/C Protection.(70 - 100% Plug setting) – 1No
2A, control MCB - 3 Nos.
Outgoings :
The following MCCB, should be supplied with S/C, E/F, O/C Electromagnetic Protection.(70 - 100% Plug setting) – 1No
63A ,16KA TPN, MCCBs - 3 Nos
200A ,25KA TPN, MCCBs - 2 Nos
100A ,25KA TPN, MCCBs - 4 Nos
Bus Bar : 800 A TPN Alluminium Bus Bar-1 Set
Metering Incomer :
CT Operated Load Manager ( similar to EM-6400 ) - 1 No
LED phase indication lamps with toggle switch -1set
MAIN M.V.PANEL ( FOR 160 KVA OUTDOOR T/F)
Incomer
800 A, 50KA, TPN MCCB, hould be supplied with S/C, E/F, O/C Protection.(70 - 100% Plug setting) – 1No
2A, control MCB - 3 Nos.
Outgoings :
The following MCCB, should be supplied with S/C, E/F, O/C Electromagnetic Protection.(70 - 100% Plug setting) – 1No
630A ,50KA TPN, MCCBs - 1 Nos
200A ,25KA TPN, MCCBs - 1 Nos
100A ,25KA TPN, MCCBs - 1 Nos
Bus Bar : 800 A TPN Alluminium Bus Bar-1 Set
Metering Incomer :
CT Operated Load Manager ( similar to EM-6400 ) - 1 No
LED phase indication lamps with toggle switch -1set
Supply,Installation,Testing and commissioning of 11 KV 3 Ph ,LT 433V ,3Ph 4 wire with off load tap changing on HT side to vary secondary voltage with in limit all as per IS 1180 of capacity 160KVA copper wound winding initially filled with transformer oil of appropriate level.
Supply and fixing of Flame proof /weather proof 2 x 20W Surfcae mounted LED LightFixtures of 4 Feet Length.
Supply ,Installation of panel consisting of 10Nos of 400W MV Ballasts with necessary control wiring for roof lights.
Supply , testing and commissioning of 3C x 185 Sqmm 11KV grade XLPE insulated armoured aluminium conductor underground cable. The cable shall conform to IS 7098/ Part-II.
Providing maintenance free Earth station with consisiting of 40 mm dia pipe standrad length (as per equipment supplier ) electrode capsule ,filled with earth enhancing compound ,sealed at both ends and braze lead for connection at one end ,suitable for direct installation at site,at a depth of 2.5 mtrs.Each earth enhancement compound upto a depth of 2.0 mtrs around the electrode capsule. Brick chamber & CI Cover etc complete.
Supply and laying of following size earth strips including excavation and refilling of earth when laid in ground and with all fixing accessories when laid in trench with necessary interconnections with earth station and equipments.
a) 50 x 5 mm G.I.Strip
b) 25 x 5 mm G.I.Strip
Providing maintenance free Earth station with consisiting of 65 mm dia pipe standrad length (as per equipment supplier ) electrode capsule ,filled with earth enhancing compound ,sealed at both ends and braze lead for connection at one end ,suitable for direct installation at site,at a depth of 2.5 mtrs.Each earth enhancement compound upto a depth of 2.0 mtrs around the electrode capsule.Brick chamber & CI Cover etc complete.
Supply and laying of following size earth strips including excavation and refilling of earth when laid in ground and with all fixing accessories when laid in trench with necessary interconnections with earth station and equipments.
a) 25 x 5 mm Copper strip Laid in Ground
Supply and wiring with the following size 650V Grade FRLS insulated multistrand Copper conductor wires in & including suitable size heavy gauge FRLS PVC Conduit concealed in wall /ceiling including all accessories such as junction box,bends,elbow including all fixing accessories and also including end terminated with suitable copper lugs.
a) 2 Runs of 2 .5 Sqmm wires with 1 Run of 2.5 Sqmm in 25 mm Dia PVC Conduit ( For High Bay Fixtures )
b) 2 Runs of 4 Sqmm with 1 Run of 4 Sqmm in 25 mm Dia PVC Conduit( for 16A Sockets )
c) 2 Runs of 6 Sqmm with 1 Run of 6 Sqmm in 25 mm Dia PVC Conduit( for 16A Sockets )
d) 4 Runs of 10 Sqmm with 2 Run of 6 Sqmm in 25 mm Dia PVC Conduit( for 16A Sockets )
Supply and Installation of following Capacity MCBs / MCCBs
a ) 6A to 25A SP MCB , 10KA
b) 40A/63A TPN MCB ,10KA
c) 100A TPN MCCB , 25 KA , Electromagnetic S/c , o/c, E/f Protection relay.
LED FITTINGS
Supply and Installation of Surface mounted 34W LED , 4' Feeet Length Light fixture including fixing clamps.
Supply and Installation of BGHB 80W LED G IV
Supply and Installation of BGHB 100W LED G IV 1
Supply and Installation of BGHB 150W LED G IV 1
Supply and Installation of BGHB 200W LED G IV 1
Supply and Installation of 90/34W LED Lamp with fixture including supply of controlgear/Driver and lamp suitable for 11/9/3 mtr existing swaged MS Poles BRTFG90 W
MV CABLES
Supply, laying and commissioning of following size 1.1 KV grade XLPE insulated armoured aluminium conductor under ground cable ,in built up cable trench/already laid RCC Hume pipe or on Cable tray/through GI pipe with all installation materials.When the cable is to be laid in ground the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid ,providing protection with sand and bricks at sides and top and bottom ,Cable route markers at every 15 mtr interval and also at the turnings.The cable shall confirm to IS 7098Part I
3.5C x 185 Sqmm
Laid in Ground
Laid in Trench
3.5C x 150 Sqmm
Laid in Ground
Laid in Trench
3.5C x 120 Sqmm
Laid in Ground
Laid in Trench
3.5C x 95 Sqmm
Laid in Ground
Laid in Trench
3.5C x 50 Sqmm
Laid in Ground
Laid in Trench
3.5C x 35 Sqmm
Laid in Ground
Laid in Trench
4C x 16 Sqmm
Laid in Ground
Laid in Trench
4C x 10 Sqmm
Laid in Ground
Laid in Trench
Providing indoor ordinary end terminations for the cable specified above with compression type steel gland,lugs using crimping tool ,insulation tape ,identification tags etc including end termination.
3.5C x 185 Sqmm
3.5C x 150 Sqmm
3.5C x 120 Sqmm
3.5C x 95 Sqmm
3.5C x 50 Sqmm
3.5C x 35 Sqmm
4C x 16 Sqmm
4C x 10 Sqmm
SUBHEAD-V :SPECIAL REPAIRS OF EOT CRANES & DOORS
For Building 11A - Capacity 80MT
Supply of 3 C x 2.5 Sqmm FLP, Copper conductor flexible cable
Supply of 2 C x 2.5 Sqmm FLP, Copper conductor flexible cable
For Building 10 : Capacity 20MT
Dismantling existing wire rope and supply , Installation & Commissioning of new Hoist galvanised wire rope Suitable for 20MT EOT Crane
For Building MTB-2 : Capacity 100/20MT
Dismantling existing wire rope and supply , Installation & Commissioning of new Hoist galvanised wire rope suitable for 100/20MT EOT Crane
For Building 14a5 : Capacity 50MT
Dismantling existing gear box,Nutech: Make : Moderl 3510 HNP, Ratio 217:1 gear box ,Supply and installation and commissioning of new gear box for Long travel operation purpose.
For Building Centrifuge : Capacity 20/5 MT
Dismantling existing wire rope and supply ,Installation and commissioning of new galvanised wire rope suitable for 20/5MT EOT Crane
For Building 12 (H1) : Capacity 80 MT
Supply & Installation of Flame proof thruster brake of FLP transistor type Lm 2100,Kgs 46,415V AC C?S 50,HP : 1/6,3Phase Make : Electromag method.
For Building 15 : Capacity 5 MT
Supply and Installation of Siemens Thermal over load relay, Model : 3UA50 00 -0k (0.8-1.25 Amps)
For Building 15 : Capacity 5 MT
Supply and Installation of Siemens Thermal over load relay, Model : 3UA50 00 -1J (6-10 Amps)
For Building 15 : Capacity 100/20 MT
Supply and Laying ,Testing and commissioning of of 12C x 1.5 Sqmm Flame proof flexible copper conductor cable The cable shall be laid on cable tray or shall be clamped to wall/ceiling.Make : Lapp Cable /Equivalent for remote pendant control.
For Building 8 & 6A : Capacity 80/20 MT & 20MT
Supply,Installation & Commssioning of Sinamics v20,3kw VVF Drives ( Siemens) for LT/CT Operation.
Supply and installation of siemens 3 pole 10Amps (10kA) MCBs for above drives installation purpose.
For Building 10 : Capacity 100/20 MT
Supply and Laying ,Testing and commissioning of of 12C x 1.5 Sqmm Flame proof flexible copper conductor cable The cable shall be laid on cable tray or shall be clamped to wall/ceiling.Make : Lapp Cable /Equivalent for remote pendant control.
Supply of transformer oil - IS 335 and top up/replacement in existing thruster brake motor for all cranes.
For Building 16D : Capacity 3MT
Supply and Laying, T&C of 3C x 2.5 Sqmm Flame proof flexible copper conductor cable.The cable shall be laid on cable tray or shall be clamped to wall/ceiling.Make : Lapp Cable /Equivalent for remote pendant control.
For Building 14A4 : Capacity 25MT
Supply and Laying,T&C of 3C x 2.5 Sqmm Flame proof flexible copper conductor cable. The cable shall be laid on cable tray or shall be clamped to wall/ceiling.Make : Lapp Cable /Equivalent for remote pendant control.
For Building 13,6A,8 &7B : Capacity 10,20 & 80/20MT
Replace/Modification of existing Hoist encoder FLP Junction Box ,Supply with new aluminium bush connectingcoupling ,Installation and commissioning etc.
For Building 29 : Capacity 30MT
Supply and Laying,T&C of 12C x 1.5 Sqmm Flame proof flexible copper conductor cable. The cable shall be laid on cable tray or shall be clamped to wall/ceiling.Make : Lapp Cable /Equivalent for remote pendant control.
For Building 1 : Capacity 10MT
Supply and Installation of 6 mm Zinc Galvanised Drag Chain of standrad make long Travel Fastening cable protection.
For Building NDT : Capacity 7.5MT
Replacement of burnt Semiconductor Fuses ,Siemens (SITOR) Rating : 20Amps , Model : 3NE1814-00
For Building 3 : Capacity 3MT
Replacement of existing 3 Ph 2 KWBrake motor for Hoist .Supply & commssioning of same suitable motor with FLP enclosure rated 5.52A,415V AC,1500 RPM for 2 speeds.
For Building 12 (H1) : Capacity 80MT
Supply and Laying,T&C of 3C x 2.5 Sqmm Flame proof flexible copper conductor cable. The cable shall be laid on cable tray or shall be clamped to wall/ceiling.Make : Lapp Cable /Equivalent for remote pendant control.
For Building 13 : Capacity 10MT
Supply and Laying,T&C of 16C x 1.5 Sqmm Flame proof flexible copper conductor cable. The cable shall be laid on cable tray or shall be clamped to wall/ceiling.Make : Lapp Cable /Equivalent for remote pendant control.
For Building 13 : Capacity 10MT
Supply and Laying,T&C of 3C x 2.5 Sqmm Flame proof flexible copper conductor cable. The cable shall be laid on cable tray or shall be clamped to wall/ceiling.Make : Lapp Cable /Equivalent for remote pendant control.
For Building MTB-II : Capacity 100/20 MT
Supply and Laying,T&C of 3C x 2.5 Sqmm Flame proof flexible copper conductor cable. The cable shall be laid on cable tray or shall be clamped to wall/ceiling.Make : Lapp Cable /Equivalent for remote pendant control.
Supply and Laying,T&C of 4C x 10 Sqmm Flame proof flexible copper conductor cable. The cable shall be laid on cable tray or shall be clamped to wall/ceiling.Make : Lapp Cable /Equivalent for remote pendant control.
Supply and Laying,T&C of 12C x 2.5 Sqmm Flame proof flexible copper conductor cable. The cable shall be laid on cable tray or shall be clamped to wall/ceiling.Make : Lapp Cable /Equivalent for remote pendant control.
Supply and Laying,T&C of 2C x 1.5 Sqmm Flame proof flexible copper conductor cable. The cable shall be laid on cable tray or shall be clamped to wall/ceiling.Make : Lapp Cable /Equivalent for remote pendant control.
For Building 12 (H3)
Supply and Laying,T&C of 4C x 4 Sqmm Flame proof flexible copper conductor cable. The cable shall be laid on cable tray or shall be clamped to wall/ceiling.Make : Lapp Cable /Equivalent for remote pendant control.
For Building 10,15,7B
Supply and Laying,T&C of 4C x 2.5 Sqmm Flame proof flexible copper conductor cable. The cable shall be laid on cable tray or shall be clamped to wall/ceiling.Make : Lapp Cable /Equivalent for remote pendant control.
Supply & Installation of Siemens Power contactor Model : 3TF31.1F,16Amp,415V AC (Coil Volt 230V AC )
DOORS
Repairs to be carrried out for Building 11 Back Doors as under:- a)Removing of Existing 11.2mt concrete and 40mm square rail square bars, Re algnment of square rails and concreting of motorised sliding Door -1no b)Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. c)Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. d)Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Building 13: Sliding Doors Supply & Installation of MS Wheels, Outer Dia 390 x 92mm width & Shaft Bore ID 60mm as per dimension of existing Sliding Door MS Wheel of 40mm rail -2nos
Building 9 (O2): Hydraulic Doors Supply, Repairing, Reinstalling and Making all Arrangement for dismantling of existing Hydraulic cylinder, inspect and replacement of defective parts like internal oil seals, fixing pin & repair etc complete as per instructions by enginner in charge ., Reinstallation the same all complete job.
Repairs to be carrried out for Building 15A : Sliding Door as under:- a)Removing of 13.5mt existing concrete and bottom guide pin track of top hung sliding sheet door and Re align the bottom guide track and concreting etc.,1nos b)Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineerin- charge. c)Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cementcontent as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. d)Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
SUBHEAD-VI :SPECIAL REPAIRS TO HVAC WORKS
Provision of replacement and repair of following defective parts of Water Cooled Scroll Chilling Machine of 120 TR Capacity of Make Dunham Bush. The spares / parts must be as per the specification / model no. / part no. provided. The item should be compatible with the corresponding machines.The work also includes pressure testing, vacuumization and dehydration of the refrigerant line, charging of refrigerant gas, re wiring & cabling of controllers and testing & commissioning of the same as per direction of engineer-in-charge.
The Scope also includes Service charges for replacement of the rotary screw compressor ,Flooded chiller (cooler) ,necessary welding and piping works,replacing loading and un loading of equipment ,charging the refrigerant and commissioning of the chiller etc complete.
Providing of Microprocessor for vertical screw Chiller along with necessary control wiring .Chiller Model No : WCDX75
Supply of Dunhambush make vertical rotary screw compressor Model : 1212-6W4 R-22 or Equivalent ( For 120TR Chiller Single Compresor )
Supply of shell & tube evaporator (Chiller /cooler ) Model : H011832A1 or Equivalent ( For 120TR Chiller )
Refrigerant R-22
Compressor Oil - suniso oil 4GS for the above compressor
Providing of Loading and unloading solenoid valve assembly set
SUBHEAD-VII :SPECIAL REPAIRS TO INTERNAL ROADS AND SECURITY WALL
Providing and applying tack coat using bitumen emulsion conforming to IS: 8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom as per specifications and as directed by engineer-in- charge. On bituminous surface @ 0.25kg/sqm
Providing and laying semi- dense Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compactionand density as per specification, complete and as per directions of Engineer-in-Charge. 25 mm compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, including the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
150 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
450 mm dia. R.C.C. pipe
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete
600 mm dia RCC pipes.
900 mm dia. R.C.C. pipe
1000 mm dia. R.C.C. pipe
SECURITY WALL
Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand)
Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) :Flush/ Ruled pointing
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, including the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
NIMMA NARAYAN ENGINEERS & CONTRACTORS
TRINETRA CONSTRUCTIONS
SAI CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid