Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | Admitted-Finance |
| 3 | Admitted-Finance NO 15 PULAVAR GOVINDAN STREET GANDHI NAGAR AVADI CHENNAI 600 054 | AVADI | CHENNAI | TAMIL NADU | 600054 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | Admitted-Finance |
Tender Value
₹10.0 L
EMD Value
₹20,000
Closing Date
21 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I RD AVADI
AGE I RD AVADI CHENNAI 600054
REPAIRS AND MAINTENANCE OF LT DISTRIBUTION NETWORK AND CONNECTED WORKS IN RESIDENTIAL AREA AT CVRDE AVADI
2022_MES_533730_4
8509/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
CVRDE
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹20,000
Yes
26 Oct 2022
30 Sept 2022
24 Oct 2022
30 Sept 2022
21 Oct 2022
7 Oct 2022
30 Sept 2022 - 7 Oct 2022
60 days
Amount
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5M depth in hard/dense soil for laying of cable, pipes etc and getting out including making good existing level of the surface all as specified and directed.
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25cms of soil complete all as specified and directed.
Removing the surplus excavated materisl/soil to a distance not exc 50Mtrs and depositing, where directed at a level not exceeding 2.5 Mtr above the starting point all as specified and directed.
Supply and spread sand for sand cushioning of cables in trenches all as specified in MES Schedule Part-I and all as directed. Note: Punned thickness only will be measured and paid.
Supply and lay in trenches, old size burnt sub class 'B' bricks as specified and all as directed.
Supply and lay GI tubing 80 mm bore, light grade, galvanised, ISI marked with all specials for cable protection on road crossing/floor etc duly sealed at both ends after drawing cable all as specified and directed.
Supply and lay GI tubing 50 mm bore, light grade, galvanised, ISI marked with all specials for cable protection on road crossing/floor etc duly sealed at both ends after drawing cable all as specified and directed.
Supply and lay GI tubing 40 mm bore, light grade, galvanised, ISI marked with all specials for cable protection on road crossing/floor etc duly sealed at both ends after drawing cable all as specified and directed.
M&L for taking down unserviceable cable of any type of size 16sqmm to 185 Sqmm from trench / duct / wall etc including taking down bricks for reuse and broken bricks removing from site complete all as specified and directed. Note: Excavation items shall be measured under relevant items.
Supply and fix or passing through pipe/wall/floor/trenches XLPE insulated PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with glanded aluminium conductor of size as follows :-
(a) 6 Sqmm 4 core
(j) 10 sq mm 2 core
(h) 16 sq mm 4 core
(g) 25 sq mm 4 core
(f) 35 sqmm 3.5 core
(e) 50 sqmm 3.5 core
(d) 70 sqmm 3.5 core
(d) 95 Sqmm 3.5 core
(c) 120 sqmm 3.5 core
(b) 150 Sqmm 3.Core
(a) 185 Sqmm 3.5 core
Cutting of road to a width of 30cm and depth not exceeding 90cm for laying of protection pipe / cable including returning and filling, spreading levelling, watering and well ramming in layers and making good with PCC 1:2:4 type B1 for top 100mm thick complete all as specified and directed.
M&L for attending any breakdown in LT UG cable by excavating, identifying core fault and carry out jointing work including straight through heat shrinkable type joint of cable size 6-16 Sqmm 4 core complete all as specified and as directed. Note: Excavation,return filling, removal & taking down of the cable shall be measured under relevant items.
All as per item No. 23 above but 3.5 Core 25-50 Sqmm all as specified and as directed.
All as per item No. 23 above but 3.5Core 70-120 Sqmm all as specified and as directed.
All as per item No. 23 above but 3.5Core 150-185 Sqmm all as specified and as directed.
Opening /disconnecting the electrical connection of defective/burnt out underground LT cable of any size any core from main DB/feeder pillar / LT panel/ L T O/H line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable ,providing required thimbles/connectors at cable end and reconnecting the cable in previous location with existing main DB/Feeder pillar/LT panel/O/H line etc all as directed. Note:- (I) the cost of required earth work ie excavation,returning filling, relaying of sand/bricks required brick work/plaster/concrete and redoing the required cement work to match the existing surface is deemed to be included in quoted rates and nothing extra should be paid on this account.(ii)Additional cable/ protection pipe required at site shall be measured and paid seperatly.
S&F in repair MCCB 3 Pole, 415 V, fixed thermal and magnetic type, 25 to 100A with breaking capacity 16 KA on existing LT Panel/Feeder pillar box include taking down complete all as specified and directed.
S&F in repair MCCB 3 Pole, 415 V, fixed thermal and magnetic type, 125Amps with breaking capacity 16 KA on existing LT Panel/Feeder pillar box complete all as specified and directed.
S&F in repair MCCB 4 Pole, 415 V, Adjustable thermal and magnetic type, 160Amps with breaking capacity 36 KA on existing LT Panel/Feeder pillar include taking down box complete all as specified and directed.
S&F in repair MCCB 4 Pole, 415 V, Adjustable thermal and magnetic type, 200 Amps with breaking capacity 36 KA on existing LT Panel/Feeder pillar include taking down complete all as specified and directed.
S&F in repair MCCB 4 Pole, 415 V, Adjustable thermal and magnetic type, 400 Amps with breaking capacity 36 KA on existing LT Panel/Feeder pillar box include taking down complete all as specified and directed.
S&F in Extended Rotary Handle suitable for MCCB any rating/make as per site requirement complete all as specified and directed.
S&F in repair suitable type heavy duty capacitor 5/6 KVAR 440V complete on existing APFC Panel and testing all as specified and directed
S&F in repair suitable type heavy duty capacitor 10/12 KVAR 440V complete on existing APFC Panel and testing all as specified and directed
S&F in repair suitable type heavy duty capacitor 12.5/15 KVAR 440V complete on existing APFC Panel and testing all as specified and directed
S&F in repair MCB TPN 63A 10KA breaking capacity, 'C' curve complete all as specified and directed.
S&F in repair change over switch manual type with sheet metal enclosure 200A rating TPN 415V complete all as specified and directed.
Laying only old bricks / PCC cover laying in trenches for cable protection complete all as specified and directed . Note : bricks / PCC cover retrived from excavation shall be reused.
M&L for taking down cable of any type of size of existing cable 16sqmm to 185Sqmm from trench / duct / wall etc including old bricks / PCC cover and re-routing in trench / Cable Tray / Floor / Wall including termination/ connection complete as specified and directed. Note: Excavation,sand items shall be measured under relevant items.
M&L for replacement of hinges/ Lock with key with necessary welding/sheet metal work as per site requirement for smooth closing /opening of existing LT Panel/Feeder pillar box complete all as specified and directed.
M & L for maintance of LT feeder pillar /LT panel board any type and size indoor/outdoor by disamandling opening and taking down of all incoming and outgoing cables,cutting burnt edge of the cable whatever is required ,providing thimble lugs and glands of suitable required for different size of cable including taking out loop of the cables, cleaning of bus bars by means of rubbing grinding etc and providing PVC sleeves of suitable rating on bus bars maintaing colour code (RYB & N) including replacement of bolts nuts & wanshers and reconnecting the all incoming and outgoing connections and testing of panles on full load all as specified and as directed.
M&L for preparation old painted surface, painted with 2coats of synthetic enamel paint over a red oxide primer on surfaces of LT Panel any size complete all as specified and directed.
S&F in spreader terminal suitable for MCCB any rating/make as per site requirement complete all as specified and directed.
Ashwarya Enterprises
rc enterprises
BKR Enterprises
D Subramani and Sons
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .