Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹35.9 L+₹4.3 L (13.7%)Rejected-Finance 21 9TH MAIN 4TH CROSS GOWDAKEHOLA BAGALAKUNTE NAGASANDRA POST BANGALORE 560073 | BENGALURU URBAN | KARNATAKA | 560073 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
₹32.8 L
EMD Value
₹65,700
Closing Date
5 Dec 2023, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT TO DAMAGED ROOF CHAJJA FACIA PROJECTION OF BUILDINGS LEAKAGE SEEPAGE TREATMENT PERIODICAL SERVICES SANITARY FITTINGS KITCHEN HARDWARE CUB BOARD AND OTHER MISC B R WORKS UNDER AGE B R EAST AT AFS JALAHALLI
2023_MES_625620_1
8840/E8
Open Tender
Civil Works
Item Rate
181 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT JALAHALLI PUBLIC FUND ACCOUNT
₹65,700
15 Dec 2023
3 Nov 2023
7 Dec 2023
3 Nov 2023
5 Dec 2023
16 Nov 2023
3 Nov 2023 - 9 Nov 2023
Amount
Use and waste of form work fair finished surfaces to sides and soffits of floor or roof beams, lintels, cantilevers etc all as specified and directed by Engineer-in-Charge.
M&L for Steel reinforcement TMT bars 10mm dia and over cut to length and bent to shape required including cranking, bending spirally for hoping for columns, hooking end and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips incl removal of old reinforcement all as specified and directed by Engineer-in-Charge.
M&L for Steel reinforcement TMT bars 6mm dia to 8mm dia cut to length and bent to shape required including cranking, bending spirally for hoping for columns, hooking end and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips incl removal of old reinforcement all as specified and directed by Engineer-in-Charge.
M&L for Reinforced Cement Concrete (Nominal Mix) 1:1½:3 Type A1 (using 20 mm graded granite stone aggregate) as in Slab/beam/columns supported on walls, beams and column in floors, balconies etc complete including demolition of reinforced cement concrete and finishing the surface with one coat of white wash all as specified and directed by Engineer-in-Charge.
M&L for Dismantling/ taking down old existing unserviceable cement plaster, loose/ unsound weaken cement concrete of any description and in any position from existing external / internal surface of RCC roof/ slab/ beams/ columns/ RCC facias for an average depth of 25mm (Approx height 7.5m from natural ground level) with power driven pneumatic flat/pointed chisel and removing the honeycombed area including all the corners and making a neat profile of the cavities, roughen the smooth surface , scrapping out/removing corrosion all loose/scale/rust etc form the visible reinforcement by applying rust remover such as Rust Off 100 of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Choksey Chemicals Pvt., M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermax Limited( as approved by GE) and cleaning the steel reinforcement properly all as manufactures and all as specified and directed by Engineer-in-Charge.
(a) Providing cement based angle fillet for 75mm X 75mm admixed with Sikacim, integral waterproofing liquid M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Choksey Chemicals Pvt., M/s BOSTIk India pvt limited, M/s STP Limited, (as approved by GE) @ 0.2% by weight of cement or as per manufacturer’s instructions over a coat of acrylic emulsion bonding agent such as per as Sika Latex in 1:1:3 ratio of Make M/s Sika India Pvt Ltd, or equivalent in M/S Fosrox chemicals, M/s Choksey Chemicals Pvt., M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd (as approved by GE) having specific gravity of 1.02 or as per manufacturer’s instructions with necessary surface preparation such as creating mechanical key like roughing the surface by scrabbing, grit blasting and cleaning the existing surface using high pressure water jet machine having pressure upto 500 bar pressure to remove the dirt, dust, loose particles , wax, efforencene and other contaminations from the surface of RCC columns/ beams/ slabs/ facia/ any brick/ stone surfaces etc all as manufactures and all as specified and directed by Engineer-in-Charge.
(b) Providing and applying FRIAZINC R, corrosion inhabiliting Active Zinc rich primer of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Choksey Chemicals Pvt., M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd (as approved by GE) along the exposed reinforcement surface property and allowed to dry.
(c)Providing and applying Hibond, Epoxy based Thixotropic bonding adhesive of Make of M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Choksey Chemicals Pvt., M/s BOSTIk India pvt limited, M/s STP Limited, ( as approved by GE) over the prepared concrete surface to get a good bonding between existing concrete surface and providing Sika Rep Microcrete 4 Fiber reinforced cementitious repair micro concrete of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s Choksey Chemicals Pvt., M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd ( as approved by GE) over Epoxy based bonding agent applied area before 6 Hrs etc including providing necessary proportions , bracing and runners to relieve the member from the load coming on it including scaffolding leak proof shuttering with working platform as required and as per design and pattern complete including preparing the surface to match with the existing surface all as specified and directed.
(d) Note : The work under (Item No. 5 to Item No. 8 of BOQ) shall be carried out through authorized and qualified applicators of the any following manufacturer only. MOU to be submitted before commencement of work. M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Choksey Chemicals Pvt., M/s STP Limited, M/s BOSTIk India pvt limited,M/s Thermax Limited
(i) A performance guarantee certificate for two years shall be submitted by the contractor to the GE on completion of work as specified.
(ii) The unit rate quoted for item No. 5 to 8 of BOQ is deemed to be included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protection to outside MD land Note: Periodicity of cutting of grass shall be before commencement of work and after completion of repairs.
M&L for Preparation of plastered or un plastered old surfaces of walls, Chajja, balcony, facia etc. by brooming down or steel wire brushing scrapping down, smoke shoots moulds, mass efforescent salt, treating oil and greasy spots ect and applying one coat of cement based paint complete all as specified and directed.
M&L for Preparation of old plastered or unplastered surface of ceiling brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spotsand applying one coat of white wash complete all as specified and directed.
M&L for Preparation of old decorated plastered or unplastered surface of wall, chajja, balcony, facia etc., brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applying one coat of white wash complete all as specified and directed.
M&L for Complete removal of existing treatment of any type/description such as distempering work, internal oil emulsion etc from internal surfaces of walls & ceiling with mechanical means/grinder, then applying one coat or more coat of Birla Putty on wall of internal surfaces of walls/ceilings as required for desired smoothness and levelling of surfaces by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving surface finish all as directed
M&L for Complete removal of existing treatment of any type/description such as distempering work, internal emulsion etc from internal surfaces of walls & ceiling with mechanical means/ grinder, then applying wall care putty on internal surfaces of walls/ceilings as required for desired smoothness and levelling of surfaces in two by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving apply Two coats of plastic emulsion all specificed and as directed. Notes : (i) The prepared surface after wall putty, the contractor will inform to the Engineer-in-Charge for site inspection before applying further surface finishes. Please note that the further surface finishes work will start only after approval of the prepared surface from the Engineer-in-Charge .
M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for 4mm plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass not exc 0.5 sqm each pane complete all as specified and directed.
M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for 4mm plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass exc 0.5 sqm each pane complete all as specified and directed.
M&L Nonskid Ceramic tiles 7-8 mm thick, area of each tiles exc 0.09 sqm not exceeding 0.16 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,15 mm thick in Cement Mortar 1:4 including taking down existing tile and removing rubbish off the premises complete all as specified and as directed.
M&L Ceramic wall tiles 7-8 mm thick designed , of size 300 x 450 mm in walls etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including rendering 10 mm thick in Cement Mortar 1:3 including taking down existing tile and removing rubbish off the premises complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, or concrete or ceilings etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises and leaving the work clear of any plastering and material and labour for Rendering 15 mm thick in two layers on brick or stone or concrete surfaces,first coat 10mm thick in cement mortar 1:4 and 2nd coat 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed. (a) Water proofing compound shall be measured and paid seperately.
Supply only integral water proofing compound complete all as specified and directed. Make ;- Dr. Fixit pidi proof and equivalent.
M&L preparation of newly plastered surfaces wall/ ceiling and applying three coats of white washing on ceiling/ walls surfaces complete all as specified and directed.
M&L applying two coats of cement based paint over and including one coat of primer, including preparation of newly plastered wall surfaces of any description, complete all as specified and as directed.
Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and taking out steel/plastic/cpvc water tubing and connections including cleaning for refixing 15 mm/20mm dia .
Supplying and fixing of 20mm outer dia Female Brass Threaded Adaptor (FTA/ FBTACPVC complete all as specified.
Supplying and fixing of 20mm outer dia CPVC brass elbow and all as specified.
S & F in repairs 15 mm dia stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of following sizes
S&F in repair angular stop valve 15 mm chromium plated concealed, fancy type screwed down high pressure screwed both ends for iron pipe for 15 mm bore.
S & F in repairs Bib taps fancy type chromium plated with crutch or butterfly handle screwed down screwed for galvanised iron pipe or for brass ferrule and fixed complete for 15 mm bore
S & F in repairs viterous china wash down water closet (Pedestral pattern) EWC white incl plastic water closet seat cover and mild steels chromium plated on aluminium hinging device and connecting to 'P' or 'S' incl connecting flush pipe with flushing rim all as specified
S & F in repair viterous china squatting pan 'Orissa pattern ' size 580 x 440mm white with integral foot rests incl connecting to 'P' or 'S' trap and to flush pipe antisyphonage pipe etc compete including provn of lime concerte bedding and making good to floor all as specified
S & F in repairs PVC low level flushing cistern 10 Ltr capacity including necessary brackets incl connecting flush pipe etc and making good the disturbed surfaces all as directed
S & F in repairs viterous china wash basin white flat back size 550 x 400 mm including brackets, waste coupling etc all as specified and directed
S & F in repairs PVC flexiable pipe (Connecter) 15 mm dia, 450/650 mm long with check nut and bolt with washer all as specified
S&F in repairs PVC waste pipe 32/40mm bore for WHB & Sink
Supply and fixing of in repairs plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls bore of pipe 75 mm with PVC clamps and saddles including taking down existing pipes including dismantling of cast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls bore of pipe 110 mm with PVC clamps and saddles including taking down existing pipes including dismantling of cast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings.
S & F PVC (SWR) bends of any radius with access door bore of pipe 75 mm
S & F PVC (SWR) bends of any radius with access door bore of pipe 110 mm
S & F PVC (SWR) junction single(single T) equal or unequal with access door bore of pipe 75 mm
S & F PVC (SWR) junction single(single T) equal or unequal with access door bore of pipe 110 mm
S & F 125/ 110 mm bore PVC (SWR) floor trap plain with grating incl jointing with solvent cement
M&L Vitrified Ceramic tiles 9-10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,15 mm thick in Cement Mortar 1:4 including taking down existing tile and removing rubbish off the premises complete all as specified and as directed.
M&L Vitrified Ceramic tiles 9-10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in skirting/dado. etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,10 mm thick in Cement Mortar 1:3 including taking down existing tile and removing rubbish off the premises complete all as specified and as directed.
Note for item No 45 & 46 : (a) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (b) The manufacturer's test certificate for tiles must be submitted for approval by the concerned authority.
M&L Water proofing treatment of existing roofs as per details given below after complete removal of existing water proofing treatment and expose of top surface of RCC slab of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with water and using wire brush including removing debris to outside the MOD land complete all as specified and as directed :-
(a) Dismantling existing cement concrete/ roof tiles on roof including removing debris to outside MOD land as directed.
(b) Bring upto the slope by providing PCC 1:2:4 type B1 using 20mm graded stone aggregates of average thickness of 50 mm.
(c) Rendering 10mm thick in CM 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound as per manufacturer’s instructions.
(d) Surface should be free from any loose paint, dust or grease. Remove all existing bitumen coatings completely by using intense wire brushing, high speed water jet & vacuum cleaner for thorough cleaning of the surface to avoid ‘Peeling off’ problems.
(e) All cracks at corner joints, channels and parapets should be properly treated. For filling cracks upto 3mm crack seal material of M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical to be used. Bigger cracks, damaged portions & hollow areas must be repaired with polymer modified cement mortar.
(f) Apply a coat of self priming smart care damp proof ultra (Code 5698) of M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical with 33% dilution with water using brush/roller on newly plastered surface after curing as per IS-456 and allow to dry for 4 to 6 hours (dilution & forced coverage requirement strictly as per manufacturer’s instructions).
(g) After the primed surface has dried, apply first coat of water proofing smart care damp proof ultra (Code 5698) of M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical using brush/roller on the same primed surface & allow to dry for 4 to 6 hours.
(h) Prepare for apply 2nd coat of water proofing smart care damp proof ultra (Code 5698) of M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical using brush/roller on the same surface. The temp to be maintained 25 to 35° C through out the all above application work.
(j) In case of severe dampness an additional coat of damp proof materials to be applied.
Note for item No 48 to 57 :- (i) The work shall be carried out through authorized and qualified applicators of the following manufacturers only. MOU to be submitted before commencement of work. Make : M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical
(ii) A performance guarantee certificate for 10 years shall be submitted by the contractor to the GE on completion of work as specified.
(iii) The unit quoted rate is deemed to include taking down of water pipeline, tanks, wires (etc) found on roof and refix at the original position after complete treatment of roof.
(iv) The unit quoted rate shall be inclusive of material, all labours, tools and plants including scaffolding required for working upto approx 7.5 mtr height from natural ground level.
(v) The unit rate quoted for item is deemed to include for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protection to outside MD land.
(vi) Adoption of necessary safety arrangement like safety belts, ropes, helmets, netting etc. which are required for safety of working labour at height exceeding 3 to 25 mtr height shall be mandatary and deemed to be included in the unit rate quoted.
M&L for Preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat oil bound distemper complete all as specified and as directed.
M&L for Preparation of old plastered surfaces of wall by using pressure washer, removal all dirt and dust and applying one coat of exterior emulsion weater proof paint complete all as specified and as directed. Note:-(i) Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account. (ii) Work will be carried out through authorised applicator/ agency of approved manufacturer by GE.
M&L for Preparation of old decorated surfaces of walls by using pressure washer, remove all dirt & dust ,applying one coat of wall care putty and then and applying two coats of premium oil bound distemper over one coat of primer as per manufauture instruction of required shade complete all as specified and directed by Engineer - in - Charge. Note:-(i) Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account.
M&L for Preparation of old painted wooden surface of any description and applying one coats of synthetic enamel paint using mechanical means, not otherwise described over 10 cm width or girth, complete all as specified and directed.
M&L for Preparation of old painted surfaces of steel and applying one coat of synthetic enamel paint using mechanical means over 10 cm width or girth, not other wise described complete all as specified and as directed.
Taking down steel shutters windows / ventilators area exc 1 Sqm nexc 2 sqm each including all fittings and all as specified and directed.
Taking down steel shutters windows / ventilators area nexc 1 sqm each including all fittings and all as specified and directed.
M&L for powder coated Anodised aluminium frame for doors, windows three track with skeleton window & glazed window , ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
M& L for 4.5mm thick Anodised aluminium grill with 50mm opening (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge
M&L for Anodised aluminium window and ventilator shutters, sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. and make shutter ready for receive wire cloth/glass complete all as specified
S&F stainless steel wire cloth of 0.36mm dia of wire and average width of aperture 1.40mm with staples or serviceable fillets complete as directed by EIC
Supply and fix 5mm thick figured glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane and all as specified and directed.
S&F Stainless steel peg set of 5 pegs, powder coated and fixed to wall surfaces with PVC plug and screw complete in repairs all as specified and directed .
S&F 25mm dia mild steel powder coated drapery rod cut to length required without joints in between and fixed at openings complete in repairs all as specified and directed.
S&F Mild steel powder coated brackets for holding the drapory rod and fixed to wall with MS screw complete in repairs all as specified and as directed.
S&F Mild steel powder coated fancy type brackets fixed at both the end of drapery rod of same colour and type of drapery rod complete in repairs all as specified and as directed
S&F Plate rack of size 65 cm x 96 cm made out of stainless steel fixed in repairs complete all as specified and as directed.
S&F Sinks with drainage board made of stainless steel lmm thick of kitchen or laboratory, with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm and bowl size 410mm x 330mm x 160mm in repairs complete all as specified and as directed. Make : M/s Diamond / Nirali / Amco / TATA.
S & F in repair of 12 mm thick ,7 ply, plywood ,grade BWR ,type BB fixed to wooden frame work in wall with nails including removal of old boards if any all as specified
S&F Stainless steel spring hinges of size of approved pattern and make suitable for base/wall unit of modular kitchen Including taking down the existing one complete (Make : BIR SS /Sleek/Blum/Hettich)
S&F Stainless steel handles of size 150 mm of approved pattern and make suitable for Base/Wall unit of modular kitchen Including taking down the existing one complete (Make : Spykar /Sleek/Blum/Hettich)
S&F Stainless steel plain basket of size 530 x 505 x 100mm Including taking down the existing one complete. Make : Butterfly /Nova Sleek/DWD GRASS
S&F Stainless steel thali basket of size 600x 500x 100mm Including taking down the existing one complete Make : Butterfly /Nova Sleek/DWD GRASS
S&F Decorative laminates of 0.90 mm thick type matt finish, colour and pattern as approved. Including taken down existing one complete all as specified and as directed by Engneer-in-Charge
S&F Stainless steel bottle basket of size 200x 508x 431mm including taking down complete all as specified and directed. Make : Butterfly /Nova Sleek/DWD GRASS
S&F Stainless steel cutlery basket of size 530 x 505 x 100 mm Including taking down the existing one complete Make : Butterfly /Nova Sleek/DWD GRASS
S&F Stainless steel telescopic slider of 500 mm of approved pattern and make suitable for drawer in base unit of modular kitchen including taking down the existing one complet
M&L in repairs granite 18 to 20mm thick (table rubbed and polished) in steps,Jamps, Pillars, Windows, cills, platforms and like CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigments to match with marble shade of Granite over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) all as specified and as directed. Note : (a) The Unit rate quoted is included for Demolition of Stone Slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar (b) The unit rate is deemed to be included for rounding to edges of stone slabs.
S& F of Door Seal (1.5" Width ) as required Gate Bottom Sealing Strip Draft Excluder Stopper with Aluminium Plate & Nylon Bristles for Weather Stripping, Air & Sound Blocking all as specified
Supplying & fixing for 7 feet 4 pipes pulley operatoed cloths drying system consisting of aluminium pipe of outer dia 22mm, inner dia 19.80mm, made up of detrin with rope guide mounted on channel pair of lemgth 24 feet (distance between two pipes is adjustable) locking system to hide rope knot, channel to be mounted or fixed with self taping screws provided in kit. Rope will be HDPE double core of 4mm dia fixing to ceiling as specified and directed by Engr-in-Charge and minimum weight of one pipe shall not be less than 0.20kg, minimum weight of rope shall not be less than 7700Gms/unit (for 04 pipes).
S & F in repairs pillar tap with capstan heads chromium palted screwed down high pressure with or without letter 'Hot' or 'Cold' with long screwed shanks and flynuts screwed for galvanised iron pipe and fixed complete for 15 mm bore
S& F in repairs for CP brass health faucet alongwith flexible pipe and stay complete of approved make all as specified and directed.
S&F in repairs coloured PVC toilet cabinet of size 355x455x90mm with looking mirror in replacement of existing looking mirror/wooden cabninet and repairing the disturbed surfaces to match with existing of approved make.
S & F in repairs wall mixture incl three joints to steel pipes of 15 mm bore and plugging & screwing to walls and making good the disturbed surfaces of walls to match with existing surfaces all as directed
S&F 300mm size, 5mm thick corner glass shelf with stainless steel brackets, stainless steel railing in bathroom and fixed to wall with brackets including removing the existing damaged fitting, complete all as specified and as directed.
M&L for repair to cracks and damaged existing surface of RCC roof slab/ RCC facial/RCC chajja upto double storey (Approx height 7.50 Mtr from the natural ground level) by structural strengthing using injection pressure grouting with Sikadur 52, low viscous epoxy grout of Make of M/S Sika India Pvt Ltd, or equivalent in M/S Fosrox chemicals, M/s Choksey Chemicals Pvt., M/S BOSTik India pvt limited, M/s STP Limited , M/s Thermax Ltd(as approved by GE),complete all as manufactures and all as specified and directed by Engineer- In - charge as under:-
Providing and drilling 10mm dia holes using pneumatic drill as per site condition but not exceeding 50cm c/c in zig-zag pattern for 75mm depth and fixing high pressure bear up Metal/Aluminum body injection packer along the holes and packing with Sika -4a ,quick setting waterproofing compound of Make M/s Sika India Pvt Ltd, or equivalent in M/s Fosrox chemicals, M/s Choksey Chemicals Pvt., M/S BOSTik India pvt limited, M/s STP Limited (as approved by GE).
Mixing base and hardner of Sikadur 52 , low viscous solvent free epoxy injection grout of Make M/S Sika India Pvt Ltd, or equivalent in M/S Fosrox chemicals, M/s Choksey Chemicals Pvt., M/S BOSTik India pvt limited, M/s STP Limited (as approved by GE), using slow speed electricity operated mixing paddle (200 – 300RPM) and injecting the same using electricity operated high pressure (upto 1000 Kg/SqCM) pump until refusal to adjacent complete as per manufacturers specification.
Cutting and flushing the nozzles and excess materials with a sharp scraper to take away sharp protrusions and to get a smooth and flat finish.
Note :- The work under (Item No. 100 to Item No. 103 of BOQ) shall be carried out through authorized and qualified applicators of the any following manufacturer only. MOU to be submitted before commencement of work.M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Choksey Chemicals Pvt., M/s STP Limited, M/s BOSTIk India pvt limited,M/s Thermax Ltd
(a) A performance guarantee certificate for two years shall be submitted by the contractor to the GE on completion of work as specified.
(b) The unit rate quoted for item No. 100 to 103 of BOQ is deemed to be included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protection to outside MD land Note: Periodicity of cutting of grass shall be before commencement of work and after completion of repairs.
SRI MAHALAKSHMI CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .