Tender Value
₹35.6 Cr
Closing Date
8 Aug 2026, 11:00 amClosed
Executive Engineer MHD SKIMS /JVC
SKIMS SOURA
HVAC System for College Lab Block/Library Block at SKIMS MCH Bemina(in Selected area)
2026_PWDJK_316729_1
MHD/SKIMS/JVC/15 of 2026-27 Dated. 18.07.2026
Open Tender
Machineries/ Mechanical Engg Items
Percentage
150 days
SKIMS MCH Bemina
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
Exempted
20 Jul 2026
18 Jul 2026
10 Aug 2026
18 Jul 2026
8 Aug 2026
18 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | AIR COOLED SCREW HEAT PUMP (REVERSIBLE TYPE) For Space Cooling and Heating | - | - | - | - |
| 2 | Supply, Installation, Testing, & Commissioning of AHRI certified Reversible Air Cooled Screw Heat Pump having Single/Multiple twin rotor screw compressors not less than 321kW actual capacity for heating and not less than 130 TR actual capacity for cooling at the parameter mentioned below.Rest of the specifications as per Annexure B of the E-NIT | 2 | No | 0.42 | ₹0.85 |
| 3 | Water Pumps Set Set with VFD & Microprocessor Panel, sensor, transformer, controller, star Delta Starters for primary and secondary pumps etc.
Supply, installation, testing and commissioning of End Suction Back pull out centrifugal pumps complete with motor, base frame, vibration isolators, drain valves and other accessories. Specifications as per Annexure B of the E-NIT. | - | - | - | - |
| 4 | Chilled Water Primary Pumps Set (2w + 1S) (with VFD & Microprocessor Panel, sensor, transformer, controller, star Delta Starters for primary and secondary pumps etc.) for Space heating / cooling
Water flow rate : 240-340 USGPM for Space heating / cooling
Head : 40 ft
RPM : 1450 | 3 | No | 0.29 | ₹0.87 |
| 5 | Secondary Hot water pumps (with VFD & Microprocessor Panel, sensor, transformer, controller, star Delta Starters for primary and secondary pumps etc.) for Space heating / cooling ( (2w + 1S)
Water flow rate :240-340 USGPM for Space cooling
Head : 115ft
RPMP :1450 | 3 | No | 0.29 | ₹0.87 |
| 6 | CHILLED WATER PIPES AND VALVES | - | - | - | - |
| 7 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of Hot / chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing felts trip(as per IS:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.
Specifications as per Annexure B of the e-NIT. | - | - | - | - |
| 8 | 150mm dia (75mm insulation) | 200 | Mtr | - | - |
| 9 | 125mm dia.(50 mm insulation) | 60 | Mtr | - | - |
| 10 | INUSLATED VALVE | - | - | - | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.27 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.09 MB
BOQ_1034735.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .