Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 CrAccepted-AOC | ₹2.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.1 CrRejected-AOC | ₹2.1 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹2.2 CrRejected-AOC 302 VISHAL NAGAR PH 2 BATHINDA | BATHINDA | BATHINDA | PUNJAB | ₹2.2 Cr | L3 | Rejected-AOC L3 |
| 4 | L4₹2.3 CrRejected-AOC 180 STREET NO 10 HARPAL NAGAR NEAR TRIVENI MANDIR BHATTI ROAD BATHINDA | BATHINDA | PUNJAB | 151001 | ₹2.3 Cr | L4 | Rejected-AOC L4 |
| 5 | L5₹79,354Rejected-Finance LUDHIANA | ₹79,354 | L5 | Rejected-Finance due to wrong Boq Fill |
| Sl No | Description | Qty | Unit | SITA RAM CONTRACTOR L4 | MITTAL CONSTRUCTION COMPANY L5 | Deepak Kumar Beetan L2 | Bamrah Infrastructure Pvt Ltd L3 | R S BUILDERS L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00Excavation by mechanical means (JCB or Hydraulic Excavator) in trenches for pipe line with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade , cutting joint holes, refilling consolidation ,watering including the cost of dewatering of rainwater , diversion for traffic, night signals providing and fixing and caution boards, crossing over trenches for access to houses, watching fencing etc and removal of surplus soil outside/inside the town involving lead upto 15 mtr. Complete in all respect. | ||||||||
| 2.00Earthwork upto 1.50 mtr. Depth | ||||||||
| 3.00 | For ordinary soil having gravel upto 40% | 1 | cum. | 12,200 ₹2,11,91,400 | 12,900 ₹2,24,07,300 | 11,500 ₹1,99,75,500 | 12,013.13 ₹2,08,66,806.81 | 101 ₹101 |
| 4.00Providing, laying, fixing and testing M.S. pipe lines as per IS-3589 and specials such as tees, bends, sockets, elbows etc. in trenches in the ground including cutting, threading and testing etc. complete as per PWD Specifications. | ||||||||
| 5.00 | 450 mm i/d 6 mm thickness with Epoxy | 1 | Mtr. | 7,000 ₹21,000 | 2,500 ₹7,500 | 3,000 ₹9,000 | 3,553 ₹10,659 | 14,251 ₹14,251 |
| 6.00Providing, laying, fixing and testing M.S. pipe lines as per IS-3589 and specials such as tees, bends, sockets, elbows etc. in trenches in the ground including cutting, threading and testing etc. complete as per PWD Specifications. | ||||||||
| 7.00 | 200mm internal diametre (thickness 6.00 mm) | 1 | Nos. | - | - | - | - | 3,100 ₹3,100 |
| 8.00Providing and fixing CI Double Air valve ISI marked as per IS-14845 including jointing cost of nuts and bolts and rubber insertion all carriage complete as per PWD Specifications | ||||||||
| 9.00 | CI Double air valve screwed sized 200 mm | 1 | Each | 80 ₹2,71,840 | 75 ₹2,54,850 | 150 ₹5,09,700 | 120 ₹4,07,760 | 51,151 ₹51,151 |
| 10.00Providing and fixing flange on one end of MS pipe complete in all respect as per design, PWD specifications and as per instructions of Engineer in charge | ||||||||
Updated dates
Tender Value
₹2.7 Cr
EMD Value
₹5.5 L
Closing Date
2 Feb 2026, 12:00 pmClosed
KANDI CANAL STAGE-2 DIVISION, WRD, PUNJAB,HSP
EXN, KANDI CANAL STAGE-2 DIVISION, WRD, PUNJAB,HSP
Estimate for the construction of Rising Main-2 of Kathgarh Lift Irrigation Scheme Stage-2 off-taking from Burji 38810 Right side of BDC Main Canal
2026_WR_157015_1
22
Open Tender
Pipe Laying Works
180 days
Hoshiarpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
₹5.5 L
Yes
KANDI CANAL STAGE-2 DIVISION, WRD, PUNJAB,HSP
13 Feb 2026
1 Jan 2026
2 Feb 2026
1 Jan 2026
2 Feb 2026
1 Jan 2026
19 Jan 2026
Excavation by mechanical means (JCB or Hydraulic Excavator) in trenches for pipe line with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade , cutting joint holes, refilling consolidation ,watering including the cost of dewatering of rainwater , diversion for traffic, night signals providing and fixing and caution boards, crossing over trenches for access to houses, watching fencing etc and removal of surplus soil outside/inside the town involving lead upto 15 mtr. Complete in all respect.
Earthwork upto 1.50 mtr. Depth
For ordinary soil having gravel upto 40%
450 mm i/d 6 mm thickness with Epoxy
Providing, laying, fixing and testing M.S. pipe lines as per IS-3589 and specials such as tees, bends, sockets, elbows etc. in trenches in the ground including cutting, threading and testing etc. complete as per PWD Specifications.
200mm internal diametre (thickness 6.00 mm)
Providing and fixing CI Double Air valve ISI marked as per IS-14845 including jointing cost of nuts and bolts and rubber insertion all carriage complete as per PWD Specifications
CI Double air valve screwed sized 200 mm
Providing and fixing flange on one end of MS pipe complete in all respect as per design, PWD specifications and as per instructions of Engineer in charge
Cement concrete 1:3:6 Mixing by MANUAL means using concrete mixer volumetric type
Ordinary Kilometer Stone for Plan Roads Reinforced cement concrete M-15 grade ordinary kilometer stone of standard design as per IRC 8 1980 fixing in position including painting and printing etc. complete as per technical clause 804 of MORT&H specifications
ANY OTHER ITEM
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.90 MB
BOQ_318311.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid