Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.0 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹53.5 L+₹49,407.17 (0.93%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical 213 1 JANAKPURI BEHIND AVADH PLAZA BAREILLY 243122 | BAREILLY | BAREILLY | UTTAR PRADESH | 243122 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M/S SURYA ELECTRICALS L2 | KHAN ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | ST Pole 09 Mtr. Long | 110 | Nos. | 4,100 ₹8,142 Lowest | 15,500 ₹20,650 |
| 2.00 | ST Pole 11 Mtr. Long | 198 | Nos. | 22,800 ₹30,208 | 19,800 ₹25,560 Lowest |
| 3.00 | PCC Pole 8.5 Mtr. Long | 175 | Nos. | 2,950 ₹6,785 | 3,600 ₹6,608 Lowest |
| 4.00 | Stud Pole STP 09 Mtr. Long with stud clamp | 1 | Nos. | 4,100 ₹8,142 Lowest | 18,000 ₹21,251.8 |
| 5.00 | Stone Pad (300x300x75 mm) | 433 | Nos. | 70 ₹94.4 Lowest | 50 ₹295 |
| 6.00 | Top channel (125x65x2240mm) | 16 | Nos. | 2,100 ₹2,505.14 | 2,000 ₹2,371.8 Lowest |
| 7.00 | Dropper channel (100x50x2028mm) | 34 | Nos. | 1,700 ₹2,033.14 | 1,500 ₹2,006 Lowest |
| 8.00 | V-Type Steel cross arm with clamp | 125 | Nos. | 1,400 ₹1,679.14 | 1,000 ₹1,416 Lowest |
| 9.00 | 11 KV Pin insulator with pin complete | 438 | Nos. | 190 ₹240.13 Lowest | 200 ₹472 |
| 10.00 | 11 KV Disc insulator with fitting | 207 | Nos. | 455 ₹552.83 | 200 ₹472 Lowest |
Tender Value
₹4.5 Cr
EMD Value
₹4.5 L
Closing Date
31 Mar 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC-II ALIGARH
ALIGARH
EDC2A-48/2022-23
2023_DVVNL_785196_2
EDC2A-48/2022-23
Open Tender
Electrical Works
Turn-key
90 days
KHAIR
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
DVVNL AGRA WEBSITE
₹4.5 L
1 Apr 2023
26 Mar 2023
31 Mar 2023
26 Mar 2023
31 Mar 2023
26 Mar 2023
Amount
ST Pole 09 Mtr. Long
ST Pole 11 Mtr. Long
PCC Pole 8.5 Mtr. Long
Stud Pole STP 09 Mtr. Long with stud clamp
Stone Pad (300x300x75 mm)
Top channel (125x65x2240mm)
Dropper channel (100x50x2028mm)
V-Type Steel cross arm with clamp
11 KV Pin insulator with pin complete
11 KV Disc insulator with fitting
M.S. T-off channel with clamp B&N (100x50x1300mm)
Base angle for Transformer
F-Bracket for fitting top channel
Holding Clamp for TPMO & Fuse Set with bolt nut
Holding Clamp for Transformer
Danger Board with clamp N&B
Stay Complete
Earthing Complete
TPMO Complete
Distribution Box with clamp
ABC 3x120 + 1x95 + 1x16 Sq.mm.
P.G. Clamp
End Clamp
Eye Hook with clamp for PCC Pole with N&B
Pearsing connector
Bolt, Nut & Washers
11/0.4 KV 63 KVA Transformer
11/0.4 KV 100 KVA Transformer
11/0.4 KV 250 KVA Transformer
11/0.4 KV 400 KVA Transformer
10 MVA 33/11 KV Power Transformer with accessories
LT XLPE Cable AL. 1x400 Sq.mm.
LT XLPE Cable AL. 1 x 240 Sq.mm.
LT Cable Size 3.5x150 Sq.mm.
Cable Al. 3x300 Sq.mm. XLPE Cable 11 KV
11 KV Cable Jointing Kit indoor Size 3x300 Sq.mm
11 KV Cable Jointing Kit Outdoor Size 3x300 Sq.mm
33 KV Fuse Set
11 KV Fuse Set
Phase wire ACSR Weasel Conductor
Phase wire ACSR Rabbit Conductor
33 KV Control pannel
33 KV CT 200/100/1A
Control Cable (Copper) 4x2.5 mm Sq.
Control Cable (Copper) 2x2.5 mm Sq.
5 MVA 33/11KV Power Transformer with accessories
33KV Bus Isolator
Structure for 33 kV Isolator with Plinth & foundation
33KV Lightning Arrestor
Structure for 33 kV Lightning Arrester (3 nos.) with Plinth & foundation
33 KV VCB with CT 200/100/1A alongwith structure complete with plinth & foundation
33kV Control panel for Double T/F without differential relay
11 KV VCB Switchgears with Incoming CTR 400/200/5-5A, 350MVA
11 KV VCB Switchgears with Outgoing CTR 200/100/5-5A, 250 MVA
11 KV Bus Coupler 350 MVA
33KV Post Insulator
Structure for 33 kV Post Insulator (3 nos.) with Plinth & foundation
33KV Fuse Set
Structure for 33 kV Fuse set (3 nos.) with Plinth & foundation
11 KV 3 Core Al. XLPE Insulated 3x300 mm sq. Cable
11 KV 3 Core Al. XLPE Insulated 3x120 mm sq. Cable
Control Cable (Copper) 4x2.5 mm sq.
Control Cable (Copper) 2x2.5 mm sq.
90 lbs Rail pieces for transformer 44.64 Kg/M
Transformer bus complete with structure
Body and neutral earthing of following Transformers installed by digging of pit up to water level depth (approx. 100’) and then inserting 1-1/4" dia G.I. pipe of "B" grade, conforming to the requirement of IS specification and then connecting the top of the inserted pipe and transformer body through GI strip of size 50x6 mm with the help of nut and bolt or through gas welding, as per direction of supervising engineer including the cost of arrangement of all material, labourer, T&P, carrier etc. required for proper completion of work.
11/0.4 KV 400 KVA Transformer
11/0.4 KV 250 KVA Transformer
10 MVA Power Transformer
Power Transformer Plinth of size 3.46x4.46 Mtr.having 0.5 Mtr. below ground level and 0.4 Mtr. above ground level.
Indoor/outdoor earthing of equipments in control room
Outdoor equipment earth mat
Chemical Pipe earthing as additional earthing (for T/F, LA, CT & PT) with GI Strip (50x6 mm)
11KV XLPE Cable (3x300 Sq.mm.) Heat Shrinkable Jointing kit boxes mounted with switchgears and transformers.
11KV XLPE Cable (3x120 sq.mm.) Heat Shrinkable Jointing kit boxes mounted with switchgear Indoor.
11KV XLPE Cable (3x120 sq.mm.) Heat Shrinkable Jointing kit Outdoor
24 Volt Battery & Battery Charger Set
Complete chemical earthing of following capacity Distribution Transormer by digging pits 6” dia upto 3 mtr. deep including chemical filled pipe in between (pipe-in-pipe) ISI mark B Grade & connecting with G.I strip of size 50mm X 6mm with neutral/body of 11/0.4 KV distribution transformer to above pipe-in-pipe (PIP) and filling of chemical crystalline conductive mixture containing highly conductive material around the (pipe-in-pipe) up to 3 Mtr. including making of chamber at the top of the earthing. Other details are as below:- 1. Earth pipe material – mild steel, Galvanized. 2-Main Electrode diameter – 42.4mm. 3-Auxiliary Electrode pipe, Diameter – 76mm. 4-Wall Thickness of main Electrode: - 2.6mm. 5-Wall thickness of auxiliary hole: - 3.2mm. 6- Length of earthing electrode (PIP):- 3 Meter.
11/0.4 KV 100 KVA Transformer
11/0.4 KV 63 KVA Transformer
33 KV VCB
Chemical Pipe earthing for power transformer as additional earthing (for T/F, CT & PT) with GI Strip (50x6 mm)
Structure for 33 KV Circuit Breaker with concreating
Construction of following Transformer of Plinth of size 5’x5x4’ above ground level and one ft. below the ground level of 9”. After excavation of 4” earth, brick ballast shall be provided and rammering will be done properly after that a retaining wall of 9” width by first class brick in ratio 1:4 of cement and sand shall be made. The earth shall be filled up to one ft. below the top of the plinth. After this brick ballast shall be provided up to 6” from the earth level and proper rammering shall be done. One No. jall of 12 mm M.S. tor shall be fixed in the hollow of plinth and one ft. thick RCC in ratio of cement, sand and stone ballast shall be laid on the top of the Plinth. The 12 mm thick plastering shall be done all around the plinth in 1:4 ratio of cement and sand. The contractor shall be responsible to complete the work as per direction of Supervising Engineer. It including the cost of all material, labour T&P, carrier etc. required for proper completion of work.
11/0.4 KV 400 KVA Transformer
11/0.4 KV 250 KVA Transformer
10 MVA Power Transformer Plinth of size 3.46x4.46 Mtr. Having 0.5 Mtr. Below ground level and 0.4 Mtr. Above ground level.
FABRICATION & ERECTION OF FENCING AND CONSTRUCTION OF RETAINING WALL AROUND FOLLOWING CAPACITY T/F The complete 11/0.4 KV Substation shall be provided with two meter height fencing and retaining wall around the substation. One No. Gate with proper locking arrangement for entry of personnel shall also be provided. The fencing shall be made of 50x25 mm x10 SWG rectangular welded mesh of wire mesh in length. Wire mesh shall be fixed on panels made of 50x50x6 mm M.S. Angle. The wire mesh on panels will be supported by 25x3 mm M.S. flat on all the bracings diagonally and 50x6 M.S. Flat horizontally at the center of the panel. The panel will be joined by bolts & nuts of appropriate size with each other and on the main support on corners including supply of all material, labour, carrier and T & P etc. required for proper completion of work. The painting of complete fencing shall also be done with one coat of red oxide primer and two coat of synthetic green paint. For construction of retaining wall around the fencing, excavation of earth shall be done in foundation in ordinary soil including disposal of surplus earth at some suitable distance. The dimension of excavation shall be 1m wide, 0.45 m deep and suitable length as per wire mesh. After excavation of earth a cement concreted pad shall be laid in foundation. Concreting shall be done with Ist class brick ballast, coarse sand and cement in proportion of 8:4:1. First class brickwork shall also be done in foundation and super structure in 1:6 Cement and coarse sand including necessary cutting and moulding of bricks in foundation depth of wall 0.30 m, thickness of wall 0.35 m & superstructure brick work thickness of wall 0.23 m & depths 0.30 m including supply of all material, labour, carrier and T & P etc. required for proper completion of work.
11/0.4 KV 400 KVA Transformer
11/0.4 KV 250 KVA Transformer
11/0.4 KV 100 KVA Transformer
Demounting & carriage of following capacity transformer due to overloaded including the work of its loading & unloading, dragging etc. and also including the cost of labour and T&P etc. required for proper completion of work.
11/0.4 KV 100 KVA Transformer
11/0.4 KV 250 KVA Transformer
05 MVA 33/11 KV Power Transformer with accessories
Dismantling and removal of existing conductor/cable/GI Wire from the various area preparing their coils and then stacking in the respective JE’s (Store) as per direction of Supervising Engineer. It includes the work of cartage, cost of labour, T&P carrier etc. required for proper completion of work.
AB Cable (3x95+1x16 Sq.mm.)
ACSR Weasel Conductor
Concreating of Pole
Concreating of Stay
Safe carriage of Old line material viz. Conductor, G.I. Earth wire, ABC conductor, Cross Arm, Angle, Channel, Insulators, Clamps & other line material from any other place or from site of work to the work of its loading & unloading at the respective ends including the cost of labour, T&P and carrier etc. required for proper completion of work.
Guarding of 11 KV line by laying two nos. GI wire parallel and fixing of lacings (tilli) at a distance at 2-3 Mtr. as per RESPO manual and also including the cost of arragement of labour, T & P etc. required for proper completion of work.
Dismanteling of old damaged 33 KV VCBs (800 A 750 MVA) after opening its 11 KV cable connection removing earthing bus bar CTs and taking it out side switch yard. the work of cartage, cost of labour, T&P carrier etc. required for proper completion of work.
Tree cutting Choping work at inside substation
Plinth and Foundation Of 33 KV VCB
Laying of 11 KV XLPE cable UG includnig cost of sand and bricks by open tranch Method
Painting of indoor equipments
Painting of S/s structure
M/S SURYA ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .