Public Works Department
Rajesh T
Providing Electrical Improvements, Electrical Repairs to Power Supply Arrangement to HVAC System at Karnataka Bhavan 1 Annexe Building Kautilya Marg Chanakyapuri New Delhi.
PWD/2023-24/EL/WORK_INDENT4876
PWD/2023-24/EL/WORK_INDENT4876
Open
Electrical
Two Tender Document System(Two Cover)
PWD Electrical Division Office Bengaluru
6 documents required · 6 mandatory
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
The tenderer as a Prime Contractor having valid Class-1 & above Electrical License issued by Electrical Inspectorate Govt. of Karnataka and should have suitable technical, financial & managerial capabilities
3.2To qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2018-19 to 2022-23 c) executed in any financial year, the following minimum quantities of work: 1. Supplying & fixing of VRF Air Conditioner Systems -1 No 2. Supply & Laying of Circuit wiring-2408 Mtrs (List of quantities to be uploaded by the Tenderer).
The Tenderer shall give details of Works in Hand (Present Contract Commitment)
3.6Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under/ Assessed available tender capacity - (AxNx2.5-B) Where, A-Maximum value of construction works executed in any one year during the last five years (updated 2022-23 price level) taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. 0.25 Years (03 Months) B - Value, at 2022-23 price level, of existing commitments and on-going works to be completed during the next. 0.25 Years (03 Months) (period of completion of the works for which Tenders are invited) Note: The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.
3.2To qualify for award of this contract, each tenderer in its name should have in the last Five years i.e. 2018-19 to 2022-23. b) Satisfactorily completed (at least 50% of the contract value), as prime contractor, at least one similar work i.e., Providing Electrical Repairs & Improvements Works of value not less than Rs 21.20 Lakhs in a single work
The Bidders shall deposit E.M.D of Rs. 85,000/- through any e-payment mode.
3.2To qualify for award of this contract, each Tenderer in its name should have in the last five year period i.e. from 2018-19 to 2022-23. a) achieved in at least two financial years a minimum financial turnover (in all classes of Electrical engineering works only) of i.e.Rs. 43.00 Lakhs during last five years
3.3Each Tenderer should further demonstrate: (b) liquid assets and /or availability of credit facilities of not less than Rs.12.71 Lakhs (For Particular work only) (Credit lines/ letter of credit/ certificates from banks for meeting the fund requirement etc. (usually the equivalent of the estimated cash flow for three months in the peak construction period).
₹1,060
₹85,000
1 Jan 2024
1 Jan 2024
11 Jan 2024
5 Jan 2024
Estimate forProviding Electrical Improvements, Electrical Repairs to Power Supply Arrangement to HVAC System at Karnataka Bhavan 1 Annexe Building Kautilya Marg Chanakyapuri New Delhi.
Supplying of power- control copper conductor cable with XLP insulated with Glavanised unarmoured cable PVC tape with extruded PVC type ST2 sheathed, 650-1100V grade as per IS 7098(part 1) 1988 of Poly...
2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specifie...
2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specifie...
2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specifie...
2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specifie...
2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specifie...
5.14 Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection...
5.38 Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. 2021-22-PWD-Electrical-Uni SR-Item code-5.38
---- Items of work are i...
5.27 Supplying, fixing and wiring rotary selector switch suitable for Ammeter 2021-22-PWD-Electrical-Uni SR-Item code- 5.27
---- Items of work are including cost and conveyance of all materials, labo...
5.28 Supplying, fixing and wiring rotary selector switch suitable for Voltmeter 2021-22-PWD-Electrical-Uni SR-Item code- 5.28
---- Items of work are including cost and conveyance of all materials, la...
5.29 Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter 2021-22-PWD-Electrical-Uni SR-Item code- 5.29
---- Items of work are including cost and conveyance of all materials, labour charg...
5.47 Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting. 2021-22-PWD-Electrical-Uni SR-Item co...
5.17 Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking...
5.17 Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking...
Supply & filling of First Charge of Refrigeration gas R410 Green Gas and Oil with necessary Refrigerant Kit including Nitrogen gas for Pressure & leak testing. (AR) SE ltr no-2302 dt-12.08.2022 SL No(...
Supply Wireless Kit for remote operation of indoor units. (AR) SE ltr no-2323 dt-17.08.2022 SL No(5) ---- Items of work are including cost and conveyance of all materials, labour charges for all items...
Lifting, Shifting, installation, testing & commissioning of VRF Outdoor units with proper rubber pad and vaccumizing the pipe with pressure. (AR) SE ltr no-2323 dt-17.08.2022 SL No(3) ---- Items of wo...
Dismantling existing VRF AC-PAC units along with Piping & Shifting to Ground Floor. (AR) SE ltr no-2302 dt-12.08.2022 SL No(14) ---- Items of work are including cost and conveyance of all materials, l...
Supply of Refrigerant Y Joint Required for distribution of refrigerant in copper piping etc complete as per indoor & outdoor Units specifications. (AR) SE ltr no-2323 dt-17.08.2022 SL No(6) ---- Items...
Supply Installation Testing & Commissioning of Hi-Wall type indoor unit comprising the following - DX cooling coil made of copper tubes and aluminum fins, 10 micron prefilters, DIDW centrifugal fan wi...
Supply Installation Testing & Commissioning of Hi wall type indoor unit comprising the following - DX cooling coil made of copper tubes and aluminum fins, 10 micron prefilters, DIDW centrifugal fan wi...
Supply Installation Testing & Commissioning of Hi-wall type indoor unit comprising the following - DX cooling coil made of copper tubes and aluminum fins, 10 micron prefilters, DIDW centrifugal fan wi...
Supply of Variable refrigerant flow modular type air-conditioning system suitable for Cooling by 2nos of inverter compressor with 3 rows coil & Inverter PC Board with film capacitors. complete. outdoo...
Supply & Fixing of PPE (Polypropylene) drain piping - 25 mm dia (AR) SE ltr no-2323 dt-17.08.2022 SL No(17) ---- Items of work are including cost and conveyance of all materials, labour charges for al...
Supply & Fixing of Imported copper refrigerant piping (with 14 Gauge thickness) insulated with nitrile rubber insulation of 19 mm and 13 mm thickness. All piping shall be supported with GI holding cla...
Supply & Fixing of Imported copper refrigerant piping (with 14 Gauge thickness) insulated with nitrile rubber insulation of 19 mm and 13 mm thickness. All piping shall be supported with GI holding cla...
Supply & Fixing Imported copper refrigerant piping (with 14 Gauge thickness) insulated with nitrile rubber insulation of 19 mm and 13 mm thickness. All piping shall be supported with GI holding clamps...
Supply & Fixing Imported copper refrigerant piping (with 14 Gauge thickness) insulated with nitrile rubber insulation of 19 mm and 13 mm thickness. All piping shall be supported with GI holding clamps...
Supply Imported copper refrigerant piping (with 14 Gauge thickness) insulated with nitrile rubber insulation of 19 mm and 13 mm thickness. All piping shall be supported with GI holding clamps, hangers...
Supply & Fixing Imported copper refrigerant piping (with 14 Gauge thickness) insulated with nitrile rubber insulation of 19 mm and 13 mm thickness. All piping shall be supported with GI holding clamps...
Supply & Fixing Imported copper refrigerant piping (with 14 Gauge thickness) insulated with nitrile rubber insulation of 19 mm and 13 mm thickness. All piping shall be supported with GI holding clamps...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
government notification bc loc letter to be issued by the bank (1)(1).pdf
Others - LOC Format • 1.73 MB
KPPP kw-2 bid_ 4876 CALL-1.doc
Tender Document • 1.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .