Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39 L+₹75,000 (1.96%)Rejected-Finance V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹40.9 L+₹2.6 L (6.93%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹41.8 L+₹3.5 L (9.20%)Rejected-Finance S 5 POST OFFICE BUILDING BATWARA SRINAGAR | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L4 | Rejected-Finance Not being L1 |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
20 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS
PROVN OF AUTOMATIC VOLTAGE REGULATOR AVR FOR HAWS GULMARG UNDER GE 969 EWS
2023_MES_620124_1
CWEK-44/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 969 EWS
Class D Categories b ii
6 documents required · 6 mandatory
₹500
GE 969 EWS
₹77,000
HQ 133 WORKS ENGRS
28 Dec 2023
22 Sept 2023
28 Oct 2023
22 Sept 2023
20 Oct 2023
7 Oct 2023
22 Sept 2023 - 29 Sept 2023
30 Sept 2023
Amount
Supply, installation, testing and commisioning of copper wound HT, AVR suitable for outdoor installation of capacity 1500 KVA, suitable for HV input voltage range of 6 KV to 11 KV, HV output voltage 11 KV (+ or -) 1% with the following all standard fittings. such as silica gel breather, temperature gauge, Bucholz relay, WTI & OTI trip & alarm including by pass connections with all control cables of appropriate rating technical specifications of HT AVR. (Make: Electric Field Company/ ICON ENGINEERS PVT LTD/Indian Transformers and Electricals Pvt Ltd, Gurgaon/Powerware (SAI Electricals)
(a) Ratings Rating KVA : 1500 KVA, Number of phases & Frequency : 3 Ph 50 Hz, Type of cooling ONAN, Rated Voltage : 11 KV, Input Voltage Range : 6 KV to 12 KV, Input Current Range : 145A to 72 A, Output Voltage : 11 KV +1%, Output Current : 78.73A, Correction Rate: KV/Second : 50V/Sec, Duty Cycle : 100% Continuous Load, Type of Load : Indicative and Reactive, Guaranteed Over-all efficiency : 95%, Winding : Electrolytic grade copper purity 99.08% Impedence 1.95%, IMPEDANCE : 1.95%, (b) EFFICIENCY: AT FULL LOAD & 1.0 P.F & 75 deg C : 95%, (c) TEMPERATURE RISE: Oil by thermometer Degree C : 45, Winding by Resistance Degree C : 55, (d) INSULATION WITHSTAND 28 KV for 1 Minute, (e) SYSTEM NEUTRAL : Effectively Earthed / Resonant, Non effectively Earthed / Isolated : Isolated AVR,
(l) TERMINATION ARRANGEMENT : H.V. SIDE (CABLE BOX), Auxiliary L.V. (Cable box), Disconnecting Chambers for HT, Conservator with oil filling hole with cap & drain plug with extension of pipe, Detachable radiator with shut off valve, Oil level gauge with 3 position, Filter valve 25mmsize, Air release valve, Rating & terminal marking plate, Weather proof Marshaling box with connection for above auxiliary protection with Lamp holder with Switch, (m) Miscellaneous : Test Required : Routine Test, All routine test as per IS : 2026, Oil Pressure & Vacuum with stand test : 7 PSI, Colour shade : D.A.Gary,
(n) GENERAL ARRANGEMENT: The unit consists of following :- (i) Stepdown Transformer- Double wound Delta/Star connected. (ii) ‘ON’ Load Voltage Regulator, Auto wound Delta connected. (iii) Buck-Boost Transformer, Double wound, open/open connected, (iv) Automatic control gear consisting of :- One Electronic Voltage Relay, One Reversing Stepsyn type geared motor unit, Two limit switches in order to avoid overrunning highest and lowest positions, chain drive, coupling device and all electrical connection. (v) First filling of oil,
(P) GENERAL FEATURES: I) HAND CONTROL: Hand wheel will be located on the front of the Regulator tank at convenient operative height, II) MOTOR CONTROL:Raise / Lower push button control by means of small single phase reversible geared motor of permanent capacitor type will be provided. Limit switches will be fitted to restrict the travel at extreme positions. With this arrangement, it would also be possible to provide remote control to the Regulating Unit. The reversible geared motor would be of ‘Step-Syn’ type, III) AUTOMATIC CONTROL: For automatic correction of fluctuating supply voltage, we shall provide Electronic Relay which in its simpliest form, senses the Output Voltage and provide signal to the driving motor for necessary correction, IV) High Altitude : High Altitude operations to be taken in consideration while designing of Automatic Voltage Regulator, V) Operating Temperature :- Minus 23 degree centigrade in winters and 35 degree centigrade in summers complete all as specified and directed by Engr-in- Charge.
Electromech Engineers
M/S KULBIR SINGH SODHI AND CO
ALCO ENGINEERSPVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .