Loading…
Loading…
Tender Value
₹30 L
EMD Value
₹22,500
Closing Date
27 Apr 2026, 5:30 pmClosed
MR SE DURG 3 KUSUM DEWANGAN
CE,DURG
ORDINARY MAINTENACE WORK RESIDENTIAL & NON RESIDENTIAL BUILDING AT HEAD QUARTER SECTION 01 BEMETARA UNDER SUB DIVISON BEMETARA
188502
NIT NO. 03/Durg(Bemetara)/2026
RESTRICTED TENDER
WORKS
CE
Required Past Technical Experience: As Per NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
5 documents required · 5 mandatory
Public Works Department (PWD)
WORKS
MR SE DURG 3 KUSUM DEWANGAN
RESTRICTED TENDER
PERCENTAGE
A B C D
CE,DURG
DURG,CIRCLE
DIVISION BEMETARA
120
No
1
7137000
12012023
188502
27 Apr, 2026 5:30:38 PM IST
30 Apr, 2026 11:00:00 AM IST
8 Apr, 2026 5:30:24 PM IST
01042026
NIT NO. 03/Durg(Bemetara)/2026
ORDINARY MAINTENACE WORK RESIDENTIAL & NON RESIDENTIAL BUILDING AT HEAD QUARTER SECTION 01 BEMETARA UNDER SUB DIVISON BEMETARA
22500.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
3000000.00
2
29 Apr, 2026 5:30:02 PM IST
3000000
AS PER NIT
AS PER NIT
As Per NIT
0.00 INR
04
19d 4h 0m
4910520230005 ,4910520230006 ,4910520230007
5 documents required · 5 mandatory
₹0
₹22,500
8 Apr 2026
8 Apr 2026
30 Apr 2026
8 Apr 2026
27 Apr 2026
8 Apr 2026
29 Apr 2026
NIT SCHEDULE FOR ORDINARY MAINTENACE WORK RESIDENTIAL & NON RESIDENTIAL BUILDING (JUDICIARY RESIDENTIAL COLONY SINGHOURI, JAIL BUILDING, PG COLLAGE, GAD COLONY GUNARBORD & RTO OFFICE BUILDING BEMETARA) UNDER SUB DIVISON BEMETARA
S.N. Depar SOR Year ITEM PARTICULARS OF ITEMS QUANTITY UNIT RATE AMOUNT
1 PWD Buidling 2015 1.1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.In all types of soils. Cum. 185
2 PWD Buidling 2015 19.17.1 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore 30 Each 284
3 PWD Buidling 2015 Filling from available excavated stuff (Excluding rock) in trenches, plinth,sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M. Cum. 65
4 PWD Buidling 2015 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc.complete. 80 Cum. 371
5 PWD Buidling 2015 8.159 Providing and fixing IS: 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc complete. 35 Each 1053
6 PWD Buidling 2015 7.5.4 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand) Cum. 3263
7 PWD Buidling 2015 7.11.2 Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level:Cement Mortar 1:4 (1 cement : 4 coarse sand) Sqm 382
PWD Buidling 2015 7.11.1 Cement Mortar 1:3 (1 cement : 3 coarse sand) 55.89 Sqm 394
8 PWD Buidling 2015 12.65.1 Providing & laying 60mm thick precast interlocking concrete blocks of approved size (approx 305 sqcm) and shape/ pattern, over 40 mm thick average complete coarse sand bed with joints of 3mm thick filled by fine sand including leveling with surface vibrator, temping and sweeping etc. complete of minimum compressive strength of 250 kg/sq.cm Plain/ normal coloured precast interlock concrete block 80 Sqm 436
9 PWD Buidling 2015 16.26 Dismantling doors chowkhats with shutters (steel or wood) including architrave, hold fast etc. complete and stacking within 50 metres lead. 20 Each 100
10 PWD Buidling 2015 2.1.1 Providing and fixing form work including centring, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for:Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level. Sqm 139
11 PWD Buidling 2015 Taking out door shutters (steel or wood) including stacking within 50 metres lead. 20 Each 46.5
12 PWD Buidling 2015 Taking out window shutters (steel or wood) including stacking within 50 metres lead. 20 Each 33.5
13 PWD Buidling 2015 16.3.3 Demolishing brick masonry including arches, stacking of serviceable material disposal of unserviceable material within 50 metres lead. 30.54 Cum. 263
14 PWD Buidling 2015 16.1 Dismantling rammed moorum and boulders or rammed moorum and silt in foundation or under floor including all lead and lifts. 110 Cum. 279
15 PWD Buidling 2015 Dismantling terrazzo or mosaic or glazed vitreous or patent cement or tiled flooring or dado skirting of any thickness without sub base. 250.13 Sqm 22.5
16 PWD Buidling 2015 Dismantling lime/ cement plaster or skirting at any height raking out joints and cleaning the surface for plaster including disposal of rubbish within 50 metres lead. 260.67 Sqm 11
17 PWD Buidling 2015 16.42 Demolishing R.C.C. work including stacking of steel bars and disposal of unserviceable material within 50 metre lead. 20 Cum. 768
18 PWD Buidling 2015 16.51.1 Dismantling C.I. or asbestos rain water pipes with fittings & clamps including stacking the material within 50 metre lead 75 mm to 100mm dia pipe 45 Meter 16.5
PWD Buidling 2015 16.51.2 150 mm dia pipe. 45 Meter 20
19 PWD Buidling 2015 3.1.3 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size). Cum.
20 PWD Buidling 2015 3.1.2 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size). Cum. 2659
21 PWD Buidling 2015 3.2.1 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). Cum. 4163
22 PWD Buidling 2015 3.1.4 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size). Cum. 3552
23 PWD Buidling 2015 3.12.1 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:Thermo-Mechanically treated bars FE 415 Kg 54.5
24 PWD Buidling 2015 18.25.1 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.32 mm dia 183 Each 68.5
25 PWD Buidling 2015 4.13.1 Grading roof for water proofing treatment with: Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size) Cum. 3817
26 PWD Buidling 2015 18.13.1 Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete:Flat back half stall urinal of size 460x380x250mm 15 Each 1776
27 PWD Buidling 2015 2.1.13 Providing and fixing form work including centring, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for Weather shade, chhajja, Cornices and mouldings 106.6 Sqm 294
28 PWD Buidling 2015 18.77. 1.2 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.Tee/ Tee with door/ Bend 45°/ Bend 90° 110 mm 33 Each 154
29 PWD Buidling 2015 Supplying and stacking sludge at site including royalty, loading, unloading and carriage upto 5 km (sludge measured in stacks will be reduced by 8% for payment). 16 Cum. 248
30 PWD Buidling 2015 Providing and fixing plain asbestos cement sheet 6 mm thick in partition including fixing to frames with necessary screws etc. complete with 50x12mm teak wood beadings (frames to be paid separately). 30 Sqm 562
31 PWD Buidling 2015 8.77.1 Providing and fixing antique/ SS finished brass butt hinges with antique/ SS polished MS screw complete:125x85x5.50mm (Heavy Type) 30 Each 256
32 PWD Buidling 2015 8.79.1 Providing and fixing antique/ SS finished brass sliding door bolt with necessary bolts, nuts and antique/ SS polished MS screw complete: 300x16mm 40 Each 496
PWD Buidling 2015 8.79.2 250 x 16mm 50 Each 489
33 PWD Buidling 2015 8.100.1 Providing and fixing M.S. bright finished or black enameled door latch with necessary iron screws: 300x20x6mm 60 Each 53.5
PWD Buidling 2015 8.100.2 250x20x6mm 100 Each 50.5
34 PWD Buidling 2015 8.102.1 Providing and fixing M.S. bright finished or black enameled Tower bolts (Barrel type) with necessary iron screws: 250 mm 139 Each 34.5
PWD Buidling 2015 8.102.2 200 mm 118 Each 29
35 PWD Buidling 2015 8.103.1 Providing and fixing M.S. bright finished or black enameled handles with necessary iron screws:125 mm 147 Each 51
PWD Buidling 2015 8.103.2 100 mm 210 Each 45.5
36 PWD Buidling 2015 8.104.3 Providing and fixing M.S. bright finished or black enameled hooks and eyes with necessary iron screws:200 mm 103 Each 13
37 PWD Buidling 2015 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer. 18 Sqm 3330
38 PWD Buidling 2015 9.16.2 Providing and fixing M.S. frames of doors, windows, ventilators and cupboards joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Angle-iron frames 125.125 Kg 73.5
39 PWD Buidling 2015 9.6.2 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. Kg 68
40 PWD Buidling 2015 9.42.2 Providing and fixing in position welded steel wire fabric to concrete/ wooden/ angle iron posts including securing and screwing with G.I. tying wire, G.I. staples, G.I.U-nails or steel pins etc., complete Aperture 50x25mm 60 Sqm 569
41 PWD Buidling 2015 9.43.1 Providing and fixing in position chain linked steel wire fabric made of 4 mm dia G.I. wire of required width in mesh to concrete/ wooden/ angle iron posts including securing and screwing with 2mm dia G.I. wire, G.I.staples, G.I.U-nails or steel pins etc., complete.Aperture 50x50mm Sqm 331
42 PWD Buidling 2015 Structural steel work in single section including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer. 370.94 Kg 61.5
43 PWD Buidling 2015 9.47.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately:For fixed portion Kg 331
44 PWD Buidling 2015 9.46 Extra for powder coating (minimum 50 micron) on steel sections instead of red oxide zinc chromate primer Kg 24.5
45 PWD Buidling 2015 9.47.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately:For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately). Kg 338
46 PWD Buidling 2015 9.51.2 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4 mm thickness Sqm 708
47 PWD Buidling 2015 10.1.2 Providing corrugated G.I. sheet roofing including vertical/ curved surfaces fixed with galvanized iron, J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with\ white lead including painting with primer and paint on overlapping of sheets complete excluding the cost of purlins rafters and trusses. (Zinc coating not less than 272 gms/sqm)1.00 mm thick sheet (weight 8.60 kg/m2) 35 Sqm 810
PWD Buidling 2015 10.1.3 0.63 mm thick sheet (weight 5.70 kg/m2) 65 Sqm 678
48 PWD Buidling 2015 10.25.2 Providing and fixing corrugated fibre glass sheet roofing in any shade/ colour fixed with G.I. ‘J’ hooks, bolts, nuts and washers etc. complete but excluding cost of purlins, rafters, trusses etc. with:2.00mm thick fibre glass sheet Sqm 610
49 PWD Buidling 2015 10.26.2 Providing and fixing plain fibre glass sheet roofing in any shade/ colour fixed with G.I. ‘J’ hooks, bolts, nuts and washers etc. complete but excluding cost of purlins, rafters, trusses etc. with: 2.00mm thick fibre glass sheet Sqm 563
50 PWD Buidling 2015 8.151 Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge. Met. 346
PWD Buidling 2015
51 PWD Buidling 2015 8.149.1 Providing and fixing factory made PVC door shutters of specified thickness made of styles and rails of a UPVC hollow section of specified size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws.24 mm thick door shutters with styles and rails of size 59x24 mm Sqm 2399
52 PWD Buidling 2015 11.1.2 Providing and making 6mm thick cement plaster of mix: In Cement mortar 1:4 (1 cement : 4 fine sand) 120.2 Sqm 87
53 PWD Buidling 2015 11.2.4 Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand) 250.98 Sqm 91.5
PWD Buidling 2015 11.2.3 In Cement Mortar 1:5 (1 cement : 5 fine sand) 175.62 Sqm 96.5
54 PWD Buidling 2015 11.3.4 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand) 239.4 Sqm 107
55 PWD Buidling 2015 Neat Cement punning. Sqm 33
56 PWD Buidling 2015 12.3.2 Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement.50 mm thick 134.4 Sqm 254
PWD Buidling 2015 40 mm thick Sqm 222
57 PWD Buidling 2015 12.7.1 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size upto 200x300mm 135.15 Sqm 587
PWD Buidling 2015 12.7.2 Size above 200x300mm 110.01 Sqm 646
58 PWD Buidling 2015 12.9.1 Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.Size 300x300mm 107.05 Sqm 692
PWD Buidling 2015 12.9.2 Size above 300x300mm Sqm 728
59 PWD Buidling 2015 9.13 Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer. Kg 75
60 PWD Buidling 2015 12.39.5 15mm thick Marble stone slab in, tread & risers of steps, skirting, dado, walls and pillars on 12mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) and jointed with grey cement slurry including matching pigment, rubbing and polishing etc. complete. (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 M) Udaipur green marble 5.9 Sqm 1576
61 PWD Buidling 2015 12.38.5 15mm thick Marble stone slab flooring over 18mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including grinding rubbing and polishing etc.complete. (Area of slab should be 0.50 sqm and above)Udaipur green marble 17.34 Sqm 1497
62 PWD Buidling 2015 25 mm thick KOTA stone slab flooring over 20mm (Average) thick base of cement mortar 1:4 laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing etc. complete (Area of slab to be over 0.20 sqm and upto 0.50 sqm) Sqm 897
63 PWD Buidling 2015 Providing and fixing un-polished 45mm to 50mm thick RAJIM SAND STONE in floors laid on sand bed of average thickness 50mm and pointing with cement mortar 1:3 (1 cement : 3 coarse sand) including finishing complete. Sqm 280
64 PWD Buidling 2015 18.4.1 Providing and fixing vitreous china water closet (European type W.C.pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :White pedestal type 12 Each 2882
65 PWD Buidling 2015 17.1.1 Repairs to plaster in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls with cement mortar 1:4 (1 cement : 4 fine sand) complete including disposal of rubbish to the dumping ground within 50metres lead : Thickness upto 15mm Sqm 132
66 PWD Buidling 2015 18.7.1 Providing and fixing 10 litre capacity P.V.C. low level flushing cistern conforming to IS : 7231, with all fittings and fixtures complete.White 12 Each 729
67 PWD Buidling 2015 17.12.1 Renewing glass panes, with putty and nails wherever necessary: Float glass panes of thickness 4 mm 42.45 Sqm 524
68 PWD Buidling 2015 18.1.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ),100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Long pattern W.C. pan of size 580 mm 12 Each 2459
PWD Buidling 2015 18.1.3 White Orissa pattern W.C. pan of size 580x440 mm 10 Each 2899
69 PWD Buidling 2015 18.15 Providing and fixing one piece construction white vitreous china squatting plate urinal with an integral rim longitudinal flushing pipe,standard size G.I. flush pipe for back and front flush, C.P. brass coupling complete including cutting and making good the walls and floors etc. wherever required : 18 Each 2014
70 PWD Buidling 2015 Providing and fixing stainless steel AISI-304(18/8) wash basin with C.I.brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : 6 No 3876
71 PWD Buidling 2015 18.17.1 Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required :White Size 550x450 mm 22 Each 1430
72 PWD Buidling 2015 18.76.1 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete.75 mm dia pipe. 120 Met. 182
PWD Buidling 2015 18.76.2 110 mm dia pipe. 110 Met. 267
73 PWD Buidling 2015 18.77. 1.1 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.Tee/ Tee with door/ Bend 45°/ Bend 90°75 mm 30 Each 113
PWD Buidling 2015 18.77.1.2 110 mm 35 Each 154
PWD Buidling 2015 18.77.1.3 150 mm 40 Each 273
PWD Buidling 2015 18.77.2.1 Double "Y" with or without door 75 mm 20 Each 129
PWD Buidling 2015 18.77.2.2 110 mm 25 Each 224
PWD Buidling 2015 18.77.3.1 Vent covel 75 mm 28 Each 34
PWD Buidling 2015 18.77.3.2 110 mm 30 Each 44
PWD Buidling 2015 18.77.4.1 Access door cap 75 mm 35 Each 49.5
PWD Buidling 2015 18.77.4.2 110 mm 40 Each 59
PWD Buidling 2015 18.77.5 "P" trap 110mmx110mm long 20 Each 227
PWD Buidling 2015 18.77.6 Nahani trap 110x75mm 18 Each 90.5
PWD Buidling 2015 18.77.7 Multi floor trap 110 16 Each 122
PWD Buidling 2015 18.77.8 Plain reducing Tee 110x75mm 15 Each 129
74 PWD Buidling 2015 18.78.1 Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.75 mm 83 Each 57
PWD Buidling 2015 18.78.2 110 mm 53 Each 61
75 PWD Buidling 2015 18.79.1 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with paint of any colour over a coat of primer (of approved quality) for new work :100 mm diameter pipe 79.38 Met. 24.5
PWD Buidling 2015 18.79.2 75 mm diameter pipe 88.2 Met. 19
76 PWD Buidling 2015 19.4.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.15 mm nominal outer dia .Pipes. Met. 110
PWD Buidling 2015 19.4.2 20 mm nominal outer dia .Pipes. 58.8 Met. 151
PWD Buidling 2015 19.4.3 25 mm nominal outer dia .Pipes. 41.16 Met. 199
77 PWD Buidling 2015 19.8.1 Providing and fixing concealed in wall G.I. pipes medium class complete with G.I. fittings and clamps, including painting with anti corrosive bitumastic paint, cutting chases, making good the walls etc. and testing of joints complete:15 mm dia nominal bore 120 Met. 188
PWD Buidling 2015 19.8.2 20 mm dia nominal bore 125 Met. 221
PWD Buidling 2015 19.8.3 25 mm dia nominal bore 155 Met. 297
78 PWD Buidling 2015 19.9.1 Providing and laying in trenches G.I. pipes medium class complete with G.I. fittings including excavation of trenches, refilling the same and testing of joints complete:15 mm dia. nominal bore 150 Met. 131
PWD Buidling 2015 19.9.2 20 mm dia. nominal bore 110 Met. 159
79 PWD Buidling 2015 19.11.1 Providing and fixing G.I. Union in G.I. pipe (New work) including cutting and threading the pipe and making long screws etc. complete:15 mm nominal bore 59 Each 85
PWD Buidling 2015 19.11.2 20 mm nominal bore 59 Each 98
PWD Buidling 2015 19.11.3 25 mm nominal bore 24 Each 117
80 PWD Buidling 2015 19.12.1 Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :15 mm nominal bore. 60 Each 186
PWD Buidling 2015 19.12.2 20 mm nominal bore. 24 Each 199
PWD Buidling 2015 19.12.3 25 mm nominal bore. 24 Each 218
81 PWD Buidling 2015 19.13.1 Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality: Bib cock (250 grams) 30 Each 185
PWD Buidling 2015 19.13.2 Bib cock (350 grams) 20 Each 237
PWD Buidling 2015 19.13.3 Stop cock (350 grams) 25 Each 237
82 PWD Buidling 2015 19.14.1 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Bib cock (400 grams) 20 Each 382
PWD Buidling 2015 19.14.2 Long nose bib cock (500 grams) 10 Each 455
PWD Buidling 2015 19.14.3 Long body bib cock (500 grams) 30 Each 426
PWD Buidling 2015 19.14.4 Piller Cock (400 grams) 22 Each 398
PWD Buidling 2015 19.14.5 Two way bib cock (800 grams) 18 Each 708
PWD Buidling 2015 19.14.6 Stop cock (concealed) (600 grams) 15 Each 494
PWD Buidling 2015 19.14.7 Angle valve for basin mixer and geyser points (450 grams) 10 Each 382
PWD Buidling 2015 19.14.8 Basin mixer pillar tap with spout (1000 grams) 8 Each 1248
PWD Buidling 2015 19.14.9 Kitchen sink mixer with cast swivel spout (1000 grams) 9 Each 1248
PWD Buidling 2015 19.14.10 Wall mixer with elegant knob (1400 grams) 7 Each 1787
PWD Buidling 2015 19.14.11 Hand shower set with flexible extension pipe 10 Each 754
PWD Buidling 2015 19.14.12 Bottle trap set with extension pipes 8 Each 473
PWD Buidling 2015 19.14.13 Toilet paper holder 9 Each 248
PWD Buidling 2015 19.14.14 Soap dish plate 8 Each 163
PWD Buidling 2015 19.14.15 Shower rose (revolving type) (150mm) 7 Each 269
PWD Buidling 2015 19.14.16 Towel rail (600mm long x 20mm dia) 5 Each 338
PWD Buidling 2015 19.14.17 Towel ring (150 mm dia) 4 Each 254
PWD Buidling 2015 19.14.18 Wall mixer (telephonic type) with crutch arrangement for hand shower (1400gms) 10 Each 1764
PWD Buidling 2015 19.14.19 Health foscet (hand jet) with flexible connection pipe (for WC) 10 Set 774
PWD Buidling 2015 19.14.20 CP brass water jet to be fixed in seat cover of WC with flexible connection pipe 8 Set 577
PWD Buidling 2015 19.15 Providing and fixing stainless steel drain jali of approved make/quality. 30 Each 51
PWD Buidling 2015 19.16.1 Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end): 25 mm nominal bore 21 Each 436
PWD Buidling 2015 19.16.2 32 mm nominal bore 23 Each 510
83 PWD Buidling 2015 Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) withhinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : 8 Each 754
84 PWD Buidling 2015 19.42 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 7000 Liter 7.3
85 PWD Buidling 2015 19.18.1 Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) : 25 mm nominal bore 12 Each 413
86 PWD Buidling 2015 19.51 Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation oundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 13 Each 4356
87 PWD Buidling 2015 20.1.2 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :100 mm diameter 130 Met. 262
88 PWD Buidling 2015 1.6.1 Extra for every additional lift of 1.5 m or part thereof All types of soils Cum. 26.5
89 PWD Buidling 2015 7.5.4+ 7.6 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand) Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: Cum. 3384
90 PWD Buidling 2015 Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brickmasonry. 150 Sqm 62.5
91 PWD Buidling 2015 2.1.2 Providing and fixing form work including centring, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for Wall of any thickness including attached pilasters, buttresses etc. in super structure. 152.88 Sqm 228
PWD Buidling 2015 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape Sqm 297
PWD Buidling 2015 2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ) Sqm 235
PWD Buidling 2015 2.1.8 Beams, lintels, cantilevers & walls 171.43 Sqm 202
92 PWD Buidling 2015 8.12.2 Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.35 mm. thick (single leaf) Sqm 2005
93 PWD Buidling 2015 Providing and fixing in position doors, windows and ventilators frames made of cold rolled pressed steel sheet framed profiles made from commercial M.S. Sheets conforming to I.S. 513 of 1973 and as per general specifications of I.S 4351 including hinges jamb, lock jamb, steel butt hinges, base tie, joints mitred and welded with 10cm long legs of size 15x3mm M.S. flat, embedded in cement concrete blocks 15x10x10cm size of grade M-10 or rawl plugs and screws or with fixing clips or with bolts and nuts including neatly compacted filling M-10 cement concrete in 219.4 Mtr. 474
94 PWD Buidling 2015 Providing and fixing at all height false ceiling consisting of frame work "W" / "U" / "L" sections made of G.I. sheet with zinc coating of grade 120 consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.55mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all
95 PWD Buidling 2015 screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed including providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part-I all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. 88.14 Sqm 658
Sub Engineer Sub Divisional Officer PWS (B&R) Sub Dn. Bemetara Executive Engineer PWD (B&R) Division Bemetara
NIT SCHEDULE FOR FOR ORDINARY MAINTENACE WORK RESIDENTIAL & NON RESIDENTIAL BUILDING AT HEAD QUARTER SECTION 01 BEMETARA UNDER SUB DIVISON BEMETARA
PAC RS : 30 LACS
S.N. Depar SOR Year ITEM PARTICULARS OF ITEMS QUANTITY UNIT RATE AMOUNT
1 PWD Buidling 2015 1.1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.In all types of soils. Cum. 185
2 PWD Buidling 2015 19.17.1 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore 30 Each 284
3 PWD Buidling 2015 Filling from available excavated stuff (Excluding rock) in trenches, plinth,sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M. Cum. 65
4 PWD Buidling 2015 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc.complete. 80 Cum. 371
5 PWD Buidling 2015 8.159 Providing and fixing IS: 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc complete. 35 Each 1053
6 PWD Buidling 2015 7.5.4 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand) Cum. 3263
7 PWD Buidling 2015 7.11.2 Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level:Cement Mortar 1:4 (1 cement : 4 coarse sand) Sqm 382
PWD Buidling 2015 7.11.1 Cement Mortar 1:3 (1 cement : 3 coarse sand) 55.89 Sqm 394
8 PWD Buidling 2015 12.65.1 Providing & laying 60mm thick precast interlocking concrete blocks of approved size (approx 305 sqcm) and shape/ pattern, over 40 mm thick average complete coarse sand bed with joints of 3mm thick filled by fine sand including leveling with surface vibrator, temping and sweeping etc. complete of minimum compressive strength of 250 kg/sq.cm Plain/ normal coloured precast interlock concrete block 80 Sqm 436
9 PWD Buidling 2015 16.26 Dismantling doors chowkhats with shutters (steel or wood) including architrave, hold fast etc. complete and stacking within 50 metres lead. 20 Each 100
10 PWD Buidling 2015 2.1.1 Providing and fixing form work including centring, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for:Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level. Sqm 139
11 PWD Buidling 2015 Taking out door shutters (steel or wood) including stacking within 50 metres lead. 20 Each 46.5
12 PWD Buidling 2015 Taking out window shutters (steel or wood) including stacking within 50 metres lead. 20 Each 33.5
13 PWD Buidling 2015 16.3.3 Demolishing brick masonry including arches, stacking of serviceable material disposal of unserviceable material within 50 metres lead. 30.54 Cum. 263
14 PWD Buidling 2015 16.1 Dismantling rammed moorum and boulders or rammed moorum and silt in foundation or under floor including all lead and lifts. 110 Cum. 279
15 PWD Buidling 2015 Dismantling terrazzo or mosaic or glazed vitreous or patent cement or tiled flooring or dado skirting of any thickness without sub base. 250.13 Sqm 22.5
16 PWD Buidling 2015 Dismantling lime/ cement plaster or skirting at any height raking out joints and cleaning the surface for plaster including disposal of rubbish within 50 metres lead. 260.67 Sqm 11
17 PWD Buidling 2015 16.42 Demolishing R.C.C. work including stacking of steel bars and disposal of unserviceable material within 50 metre lead. 20 Cum. 768
18 PWD Buidling 2015 16.51.1 Dismantling C.I. or asbestos rain water pipes with fittings & clamps including stacking the material within 50 metre lead 75 mm to 100mm dia pipe 45 Meter 16.5
PWD Buidling 2015 16.51.2 150 mm dia pipe. 45 Meter 20
19 PWD Buidling 2015 3.1.3 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size). Cum. 2409
20 PWD Buidling 2015 3.1.2 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size). Cum. 2659
21 PWD Buidling 2015 3.2.1 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). Cum. 4163
22 PWD Buidling 2015 3.1.4 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size). Cum. 3552
23 PWD Buidling 2015 3.12.1 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:Thermo-Mechanically treated bars FE 415 Kg 54.5
24 PWD Buidling 2015 18.25.1 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.32 mm dia 183 Each 68.5
25 PWD Buidling 2015 4.13.1 Grading roof for water proofing treatment with: Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size) Cum. 3817
26 PWD Buidling 2015 18.13.1 Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete:Flat back half stall urinal of size 460x380x250mm 15 Each 1776
27 PWD Buidling 2015 2.1.13 Providing and fixing form work including centring, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for Weather shade, chhajja, Cornices and mouldings 106.6 Sqm 294
28 PWD Buidling 2015 18.77. 1.2 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.Tee/ Tee with door/ Bend 45°/ Bend 90° 110 mm 33 Each 154
29 PWD Buidling 2015 Supplying and stacking sludge at site including royalty, loading, unloading and carriage upto 5 km (sludge measured in stacks will be reduced by 8% for payment). 16 Cum. 248
30 PWD Buidling 2015 Providing and fixing plain asbestos cement sheet 6 mm thick in partition including fixing to frames with necessary screws etc. complete with 50x12mm teak wood beadings (frames to be paid separately). 30 Sqm 562
31 PWD Buidling 2015 8.77.1 Providing and fixing antique/ SS finished brass butt hinges with antique/ SS polished MS screw complete:125x85x5.50mm (Heavy Type) 30 Each 256
32 PWD Buidling 2015 8.79.1 Providing and fixing antique/ SS finished brass sliding door bolt with necessary bolts, nuts and antique/ SS polished MS screw complete: 300x16mm 40 Each 496
PWD Buidling 2015 8.79.2 250 x 16mm 50 Each 489
33 PWD Buidling 2015 8.100.1 Providing and fixing M.S. bright finished or black enameled door latch with necessary iron screws: 300x20x6mm 60 Each 53.5
PWD Buidling 2015 8.100.2 250x20x6mm 100 Each 50.5
34 PWD Buidling 2015 8.102.1 Providing and fixing M.S. bright finished or black enameled Tower bolts (Barrel type) with necessary iron screws: 250 mm 139 Each 34.5
PWD Buidling 2015 8.102.2 200 mm 118 Each 29
35 PWD Buidling 2015 8.103.1 Providing and fixing M.S. bright finished or black enameled handles with necessary iron screws:125 mm 147 Each 51
PWD Buidling 2015 8.103.2 100 mm 210 Each 45.5
36 PWD Buidling 2015 8.104.3 Providing and fixing M.S. bright finished or black enameled hooks and eyes with necessary iron screws:200 mm 103 Each 13
37 PWD Buidling 2015 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer. 18 Sqm 3330
38 PWD Buidling 2015 9.16.2 Providing and fixing M.S. frames of doors, windows, ventilators and cupboards joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Angle-iron frames 125.125 Kg 73.5
39 PWD Buidling 2015 9.6.2 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. Kg 68
40 PWD Buidling 2015 9.42.2 Providing and fixing in position welded steel wire fabric to concrete/ wooden/ angle iron posts including securing and screwing with G.I. tying wire, G.I. staples, G.I.U-nails or steel pins etc., complete Aperture 50x25mm 60 Sqm 569
41 PWD Buidling 2015 9.43.1 Providing and fixing in position chain linked steel wire fabric made of 4 mm dia G.I. wire of required width in mesh to concrete/ wooden/ angle iron posts including securing and screwing with 2mm dia G.I. wire, G.I.staples, G.I.U-nails or steel pins etc., complete.Aperture 50x50mm Sqm 331
42 PWD Buidling 2015 Structural steel work in single section including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer. 370.94 Kg 61.5
43 PWD Buidling 2015 9.47.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately:For fixed portion Kg 331
44 PWD Buidling 2015 9.46 Extra for powder coating (minimum 50 micron) on steel sections instead of red oxide zinc chromate primer Kg 24.5
45 PWD Buidling 2015 9.47.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately:For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately). Kg 338
46 PWD Buidling 2015 9.51.2 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness Sqm 708
47 PWD Buidling 2015 10.1.2 Providing corrugated G.I. sheet roofing including vertical/ curved surfaces fixed with galvanized iron, J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with\ white lead including painting with primer and paint on overlapping of sheets complete excluding the cost of purlins rafters and trusses. (Zinc coating not less than 272 gms/sqm) 0.80 mm thick sheet (weight 7.03 kg/m2) 35 Sqm 810
PWD Buidling 2015 10.1.3 0.63 mm thick sheet (weight 5.70 kg/m2) 65 Sqm 678
48 PWD Buidling 2015 10.25.2 Providing and fixing corrugated fibre glass sheet roofing in any shade/ colour fixed with G.I. ‘J’ hooks, bolts, nuts and washers etc. complete but excluding cost of purlins, rafters, trusses etc. with:2.00mm thick fibre glass sheet Sqm 610
49 PWD Buidling 2015 10.26.2 Providing and fixing plain fibre glass sheet roofing in any shade/ colour fixed with G.I. ‘J’ hooks, bolts, nuts and washers etc. complete but excluding cost of purlins, rafters, trusses etc. with: 2.00mm thick fibre glass sheet Sqm 563
50 PWD Buidling 2015 8.151 Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge. Met. 346
PWD Buidling 2015
51 PWD Buidling 2015 8.149.1 Providing and fixing factory made PVC door shutters of specified thickness made of styles and rails of a UPVC hollow section of specified size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws.24 mm thick door shutters with styles and rails of size 59x24 mm Sqm 2399
52 PWD Buidling 2015 11.1.2 Providing and making 6mm thick cement plaster of mix: In Cement mortar 1:4 (1 cement : 4 fine sand) 120.2 Sqm 87
53 PWD Buidling 2015 11.2.4 Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand) 250.98 Sqm 91.5
PWD Buidling 2015 11.2.3 In Cement Mortar 1:5 (1 cement : 5 fine sand) 175.62 Sqm 96.5
54 PWD Buidling 2015 11.3.4 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand) 239.4 Sqm 107
55 PWD Buidling 2015 Neat Cement punning. Sqm 33
56 PWD Buidling 2015 12.3.2 Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement.50 mm thick 134.4 Sqm 254
PWD Buidling 2015 40 mm thick Sqm 222
57 PWD Buidling 2015 12.7.1 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size upto 200x300mm 135.15 Sqm 587
PWD Buidling 2015 12.7.2 Size above 200x300mm 110.01 Sqm 646
58 PWD Buidling 2015 12.9.1 Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.Size 300x300mm 107.05 Sqm 692
PWD Buidling 2015 12.9.2 Size above 300x300mm Sqm 728
59 PWD Buidling 2015 9.13 Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer. Kg 75
60 PWD Buidling 2015 12.39.5 15mm thick Marble stone slab in, tread & risers of steps, skirting, dado, walls and pillars on 12mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) and jointed with grey cement slurry including matching pigment, rubbing and polishing etc. complete. (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 M) Udaipur green marble 5.9 Sqm 1576
61 PWD Buidling 2015 12.38.5 15mm thick Marble stone slab flooring over 18mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including grinding rubbing and polishing etc.complete. (Area of slab should be 0.50 sqm and above)Udaipur green marble 17.34 Sqm 1497
62 PWD Buidling 2015 25 mm thick KOTA stone slab flooring over 20mm (Average) thick base of cement mortar 1:4 laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing etc. complete (Area of slab to be over 0.20 sqm and upto 0.50 sqm) Sqm 897
63 PWD Buidling 2015 Providing and fixing un-polished 45mm to 50mm thick RAJIM SAND STONE in floors laid on sand bed of average thickness 50mm and pointing with cement mortar 1:3 (1 cement : 3 coarse sand) including finishing complete. Sqm 280
64 PWD Buidling 2015 18.4.1 Providing and fixing vitreous china water closet (European type W.C.pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :White pedestal type 12 Each 2882
65 PWD Buidling 2015 17.1.1 Repairs to plaster in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls with cement mortar 1:4 (1 cement : 4 fine sand) complete including disposal of rubbish to the dumping ground within 50metres lead : Thickness upto 15mm Sqm 132
66 PWD Buidling 2015 18.7.1 Providing and fixing 10 litre capacity P.V.C. low level flushing cistern conforming to IS : 7231, with all fittings and fixtures complete.White 12 Each 729
67 PWD Buidling 2015 17.12.1 Renewing glass panes, with putty and nails wherever necessary: Float glass panes of thickness 4 mm 42.45 Sqm 524
68 PWD Buidling 2015 18.1.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ),100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Long pattern W.C. pan of size 580 mm 12 Each 2459
PWD Buidling 2015 18.1.3 White Orissa pattern W.C. pan of size 580x440 mm 10 Each 2899
69 PWD Buidling 2015 18.15 Providing and fixing one piece construction white vitreous china squatting plate urinal with an integral rim longitudinal flushing pipe,standard size G.I. flush pipe for back and front flush, C.P. brass coupling complete including cutting and making good the walls and floors etc. wherever required : 18 Each 2014
70 PWD Buidling 2015 Providing and fixing stainless steel AISI-304(18/8) wash basin with C.I.brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : 6 No 3876
71 PWD Buidling 2015 18.17.1 Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required :White Size 550x450 mm 22 Each 1430
72 PWD Buidling 2015 18.76.1 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete.75 mm dia pipe. 120 Met. 182
PWD Buidling 2015 18.76.2 110 mm dia pipe. 110 Met. 267
73 PWD Buidling 2015 18.77. 1.1 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.Tee/ Tee with door/ Bend 45°/ Bend 90°75 mm 30 Each 113
PWD Buidling 2015 18.77.1.2 110 mm 35 Each 154
PWD Buidling 2015 18.77.1.3 150 mm 40 Each 273
PWD Buidling 2015 18.77.2.1 Double "Y" with or without door 75 mm 20 Each 129
PWD Buidling 2015 18.77.2.2 110 mm 25 Each 224
PWD Buidling 2015 18.77.3.1 Vent covel 75 mm 28 Each 34
PWD Buidling 2015 18.77.3.2 110 mm 30 Each 44
PWD Buidling 2015 18.77.4.1 Access door cap 75 mm 35 Each 49.5
PWD Buidling 2015 18.77.4.2 110 mm 40 Each 59
PWD Buidling 2015 18.77.5 "P" trap 110mmx110mm long 20 Each 227
PWD Buidling 2015 18.77.6 Nahani trap 110x75mm 18 Each 90.5
PWD Buidling 2015 18.77.7 Multi floor trap 110 16 Each 122
PWD Buidling 2015 18.77.8 Plain reducing Tee 110x75mm 15 Each 129
74 PWD Buidling 2015 18.78.1 Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.75 mm 83 Each 57
PWD Buidling 2015 18.78.2 110 mm 53 Each 61
75 PWD Buidling 2015 18.79.1 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with paint of any colour over a coat of primer (of approved quality) for new work :100 mm diameter pipe 79.38 Met. 24.5
PWD Buidling 2015 18.79.2 75 mm diameter pipe 88.2 Met. 19
76 PWD Buidling 2015 19.4.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.15 mm nominal outer dia .Pipes. Met. 110
PWD Buidling 2015 19.4.2 20 mm nominal outer dia .Pipes. 58.8 Met. 151
PWD Buidling 2015 19.4.3 25 mm nominal outer dia .Pipes. 41.16 Met. 199
77 PWD Buidling 2015 19.8.1 Providing and fixing concealed in wall G.I. pipes medium class complete with G.I. fittings and clamps, including painting with anti corrosive bitumastic paint, cutting chases, making good the walls etc. and testing of joints complete:15 mm dia nominal bore 120 Met. 188
PWD Buidling 2015 19.8.2 20 mm dia nominal bore 125 Met. 221
PWD Buidling 2015 19.8.3 25 mm dia nominal bore 155 Met. 297
78 PWD Buidling 2015 19.9.1 Providing and laying in trenches G.I. pipes medium class complete with G.I. fittings including excavation of trenches, refilling the same and testing of joints complete:15 mm dia. nominal bore 150 Met. 131
PWD Buidling 2015 19.9.2 20 mm dia. nominal bore 110 Met. 159
79 PWD Buidling 2015 19.11.1 Providing and fixing G.I. Union in G.I. pipe (New work) including cutting and threading the pipe and making long screws etc. complete:15 mm nominal bore 59 Each 85
PWD Buidling 2015 19.11.2 20 mm nominal bore 59 Each 98
PWD Buidling 2015 19.11.3 25 mm nominal bore 24 Each 117
80 PWD Buidling 2015 19.12.1 Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :15 mm nominal bore. 60 Each 186
PWD Buidling 2015 19.12.2 20 mm nominal bore. 24 Each 199
PWD Buidling 2015 19.12.3 25 mm nominal bore. 24 Each 218
81 PWD Buidling 2015 19.13.1 Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality: Bib cock (250 grams) 30 Each 185
PWD Buidling 2015 19.13.2 Bib cock (350 grams) 20 Each 237
PWD Buidling 2015 19.13.3 Stop cock (350 grams) 25 Each 237
82 PWD Buidling 2015 19.14.1 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Bib cock (400 grams) 20 Each 382
PWD Buidling 2015 19.14.2 Long nose bib cock (500 grams) 10 Each 455
PWD Buidling 2015 19.14.3 Long body bib cock (500 grams) 30 Each 426
PWD Buidling 2015 19.14.4 Piller Cock (400 grams) 22 Each 398
PWD Buidling 2015 19.14.5 Two way bib cock (800 grams) 18 Each 708
PWD Buidling 2015 19.14.6 Stop cock (concealed) (600 grams) 15 Each 494
PWD Buidling 2015 19.14.7 Angle valve for basin mixer and geyser points (450 grams) 10 Each 382
PWD Buidling 2015 19.14.8 Basin mixer pillar tap with spout (1000 grams) 8 Each 1248
PWD Buidling 2015 19.14.9 Kitchen sink mixer with cast swivel spout (1000 grams) 9 Each 1248
PWD Buidling 2015 19.14.10 Wall mixer with elegant knob (1400 grams) 7 Each 1787
PWD Buidling 2015 19.14.11 Hand shower set with flexible extension pipe 10 Each 754
PWD Buidling 2015 19.14.12 Bottle trap set with extension pipes 8 Each 473
PWD Buidling 2015 19.14.13 Toilet paper holder 9 Each 248
PWD Buidling 2015 19.14.14 Soap dish plate 8 Each 163
PWD Buidling 2015 19.14.15 Shower rose (revolving type) (150mm) 7 Each 269
PWD Buidling 2015 19.14.16 Towel rail (600mm long x 20mm dia) 5 Each 338
PWD Buidling 2015 19.14.17 Towel ring (150 mm dia) 4 Each 254
PWD Buidling 2015 19.14.18 Wall mixer (telephonic type) with crutch arrangement for hand shower (1400gms) 10 Each 1764
PWD Buidling 2015 19.14.19 Health foscet (hand jet) with flexible connection pipe (for WC) 10 Set 774
PWD Buidling 2015 19.14.20 CP brass water jet to be fixed in seat cover of WC with flexible connection pipe 8 Set 577
PWD Buidling 2015 19.15 Providing and fixing stainless steel drain jali of approved make/quality. 30 Each 51
PWD Buidling 2015 19.16.1 Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end): 25 mm nominal bore 21 Each 436
PWD Buidling 2015 19.16.2 32 mm nominal bore 23 Each 510
83 PWD Buidling 2015 Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) withhinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : 8 Each 754
84 PWD Buidling 2015 19.42 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 7000 Liter 7.3
85 PWD Buidling 2015 19.18.1 Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) : 25 mm nominal bore 12 Each 413
86 PWD Buidling 2015 19.51 Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation oundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 13 Each 4356
87 PWD Buidling 2015 20.1.2 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :100 mm diameter 130 Met. 262
88 PWD Buidling 2015 1.6.1 Extra for every additional lift of 1.5 m or part thereof All types of soils Cum. 26.5
89 PWD Buidling 2015 7.5.4+ 7.6 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand) Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: Cum. 3384
90 PWD Buidling 2015 Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brickmasonry. 150 Sqm 62.5
91 PWD Buidling 2015 2.1.2 Providing and fixing form work including centring, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for Wall of any thickness including attached pilasters, buttresses etc. in super structure. 152.88 Sqm 228
PWD Buidling 2015 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape Sqm 297
PWD Buidling 2015 2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ) Sqm 235
PWD Buidling 2015 2.1.8 Beams, lintels, cantilevers & walls 171.43 Sqm 202
92 PWD Buidling 2015 8.12.2 Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.35 mm. thick (single leaf) Sqm 2005
93 PWD Buidling 2015 Providing and fixing in position doors, windows and ventilators frames made of cold rolled pressed steel sheet framed profiles made from commercial M.S. Sheets conforming to I.S. 513 of 1973 and as per general specifications of I.S 4351 including hinges jamb, lock jamb, steel butt hinges, base tie, joints mitred and welded with 10cm long legs of size 15x3mm M.S. flat, embedded in cement concrete blocks 15x10x10cm size of grade M-10 or rawl plugs and screws or with fixing clips or with bolts and nuts including neatly compacted filling M-10 cement concrete in 219.4 Mtr. 474
94 PWD Buidling 2015 Providing and fixing at all height false ceiling consisting of frame work "W" / "U" / "L" sections made of G.I. sheet with zinc coating of grade 120 consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.55mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all
95 PWD Buidling 2015 screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed including providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part-I all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. 88.14 Sqm 658
Sub Engineer Sub Divisional Officer PWS (B&R) Sub Dn. Bemetara Executive Engineer PWD (B&R) Division Bemetara
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.13 MB
7655863263562208957_188502_Affidavit.docx
NIT • 0.01 MB
3394044244071697241_188502_BID-CAPACITY-2.docx
NIT • 0.03 MB
3272015946564334597_188502_English Notice Less than 1 Crore.docx
NIT • 0.03 MB
1495237696845279425_188502_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
6229139392019706111_188502_Latest A_ 2.doc
NIT • 0.16 MB
2036344686785053208_188502_Latest NIT APPENDIX 2.doc
NIT • 0.32 MB
6003048630321664646_188502_NIT OM PAC 30.xls
BOQ • 0.13 MB
Download all tender documents and submit your bid