Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹41.2 L+₹1.3 L (3.18%)Rejected-Finance JAISALMER RAJASTHAN 345001 INDIA UDYAM RJ 18 0001538 | JAISALMER | RAJASTHAN | 345001 | L2 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
13 Sept 2021, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Improvement to viewers gallery, composite panel, signage boards, floors, communications centre, common room, common towers and associated work at Chandan at AF Stn Jaisalmer
2021_MES_469309_1
8763/GE/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
GE (AF) Jaisalmer
As per tender docuements
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹83,000
Yes
21 Sept 2021
19 Aug 2021
15 Sept 2021
19 Aug 2021
13 Sept 2021
30 Aug 2021
21 Aug 2021 - 25 Aug 2021
Amount
Excavating in post holes (or similar holes) each not exceeding 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exceeding 50m and making good surface in hard/ dense soil complete all as specified.
Demolition of plain cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and directed.
25mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in flooring to receive tile flooring complete all as specified and directed.
PCC (1:3:6) Type C-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
Precast cement concrete (1:3:6), type C-1 (using 20mm graded stone aggregate) as solid block masonary exceeding 10cm and set in cement and sand mortar (1:6), including demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, precast concrete articles etc complete all as specified and directed.
PCC (1:4:8) Type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base of flooring finishing cement concrete surface fair and even complete all as specified and directed.
10mm thick, coloured industrial non skid endura parking tiles size 300x300mm, high strength over and including 15mm thick screed bed in cement and sand mortar 1:6 and including dismantling floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed
Vitrified ceramic tiles 10mm thick (square/ rectangular), light shade double charged, polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15mm thick screed bed in cement and sand mortar 1:6 and including dismantling floor, hearth or wall tiling including cement mortar bedding complete all as specified
Vitrified ceramic tiles 10mm thick (square /rectangular), light shade double charged, polished, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick screed bed in cement & sand mortar 1:4 and including dismantling floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed
Anodized aluminium snap grid frame work for false ceiling as per manufacturer's instructions with hangers from RCC soffit/steel trusses with 6mm dia GI rod (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long with including exposed metal frame ceiling with calcium silicate 8mm thick board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600x600mm grid including taking down/dismentling of false ceiling boards complete all as specified and directed.
Plain/froasted toughened glass door size 1.20m x 2.10m and 12mm thick including stainless steel door handle 300mm long decorative type including all necessary connected fittings and fixtures for door complete all as specified and directed.
Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty, with & including replacement of floor tiles if any broken during repair work and making good surfaces matching to the existing surfaces complete all as directed.
Plain/froasted toughened glass door 12mm thick with aluminium frame and fixed at site in aluminium snap beading fittings for glass complete all as specified and directed.
Froasted glass film over toughned glass with air force logo design as approved complete all as specified and directed
Powder coating standard anodised aluminium extruded sections as in frames for chowkats, doors, windows shutters with style and rails or for fixed glazed partitions wall frame made to shape required fixed with 150mm long screw and rawl plug with one or more rebates including necessary joining cleats, glazing clips, rubber neoprene packing for fixing, anodised aluminium snap beading screws etc complete all as specified and directed.
Anodised aluminium sections for door shutters (aluminium sections weighing 0.55 Kg/m) including necessary joining cleats, glazing clips, rubber neoprene packing, handle 02 Nos in each door shutter, 04 Nos hinges each shutter, anodised aluminium snap beading, screws etc complete all as specified and directed.
Anodized aluminium sections as in window and ventilator shutters, side hung type without sash bars (aluminium sections weighing 0.55 kg/m) including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (01 Nos each shutter), extruded anodised aluminium alloy with galvanised mild steel hinge pin, 100mm long (03 Nos each shutter), extruded anodised handle of suitable type (01 No. each shutter) etc. complete all as specified and as directed.
150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
200mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
Extruded aluminium alloy handle, fabricated type, anodised 150mm size complete all as specified and directed.
Mortice lock brass, vertical type, size 100mm 4 lever complete all as specified and directed.
Aluminium door closer hydraulically (extruded section body), universal type for door shutters upto 700 in width and weight not more than 35 Kg complete all as specified and directed.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in door, overall length of cover plate 140mm as in repair complete all as specified and directed.
Butt hinges, medium weight, cold rolled mild steel 100mm complete all as specified and directed.
PVC connection suitable for 15mm bore with PTMT nuts of 600mm length and including taking down old unserviceable complete all as specified and directed.
Galvanized steel water tubing medium grade of 15mm bore with & including all fittings fixed to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 15mm bore, complete all as specified and directed.
Galvanized steel water tubing medium grade of 20mm bore with & including all fittings fixed to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 20mm bore, complete all as specified and directed.
Taking up or down steel water tubing and connecting including cleaning and refixing for 15mm bore old steel water tubing and connection in new or old position including all new fittings and fixtures (wall, ceiling, floor etc) complete all as specified and directed.
Taking up or down steel water tubing and connecting including cleaning and refixing for 20mm bore old steel water tubing and connection in new or old position including all new fittings and fixtures (wall, ceiling, floor etc) complete all as specified and directed.
Stainless steel Curtain rod/rail 25mm dia (in lengths as directed) including matching two globe type brackets fixed at both ends with screws on walls/beam complete all as specified and directed.
Rotational moulded polyethylene water storage tanks 500 Litre capacity double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including taking down existing water storage tank complete all as specified and directed.
Bib taps 15mm bore, fency type, long body, cast copper alloy with crutch or butterfly handle, chromium plated, screwed down, high pressure, fixed as in repair complete all as specified and directed. Make : Jaquar, Cat Part No. CON-107 KN or equivalent.
Angle stop valves, 15mm bore fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed as in repair complete all as specified and directed. Make : Jaquar, Cat Part No. CON-053 KN or equivalent.
CP pillar taps 15mm bore, fency type, long body, cast copper alloy with capstain heads, chromium plated, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with longed screwed shanks and fly nut screwed for iron pipe fixed as in repair complete all as specified and directed.
Brass chromium plated towel rack 600 long (24" inch), fixed in position with steel screws, fixed as in repair complete all as specified and directed. Make : Jaquar, Cat Part No. AQN-7781A or equivalent.
Cast copper alloy, chromium plated a recessed toilet paper holder, fixed in position with steel screws, fixed as in repair complete all as specified and directed. Make : Jaquar, Cat Part No. AKB-35751 or equivalent.
Soap dish, fixed in position with steel screws, fixed as in repair complete all as specified and directed. Make : Jaquar, Cat Part No. AQN-7731 or equivalent.
Hand jet health faucet 15mm bore with all connected fittings, fixed as in repair complete all as specified and directed.
CP corner with all connected fittings, fixed as in repair complete all as specified and directed.
CP Grating 150mm size (minimum weight 100gm) fixed as in repair complete all as specified and directed.
Vitreous china wash down water closet pan (padestal pattern) with and including waste fitting, waste pipe, flushing cistern and seat cover etc. fixed as in repair complete all as specified and directed. Make : Cera "CAMPBELL" Cat Part No. 3141, 2399, 3441 or Hindware clipper Cat Part No. 92073, 92126 with cistern (complete set and fitting) Cat Part No. 92126, 92106 or equivalent.
Vitreous china bowl urinal flat back size 465x355x265mm, white coloured, with grating and union for discharge pipe and fixed as in repair complete all as specified and directed. Make : Hindware Flat back Large, Cat Part No. 60002 or Cera or equivalent.
Urinal spreader of CP for fixing with 15mm dia pipe (minimum weight 60gms) fixed as in repair complete all as specified and directed. Make(Cera/Hindware/Jaguar).
Coloured wash hand basin with built up counter "CAESER" fixed as in repair complete all as specified and directed. Make : Cera, Cat Part No. 1026, 2426 or Hindware, Cat Part No. 91048 or Hindware Tarrot Cat Part No. 91037 or equivalent.
Taking down top cover of rolling shutter gear operated type with lever gear box and crank handle and re-fixing the same in position after necessary repair such as cleaning, greasing, replacement of rusted nuts and bolts with required welding grinding and making good any damage to the existing shutters to area of shutter exc 10 sqm but not exc 30 sqm each complete all as specified and directed.
Gear operated type with lever gear box and crank handle with 1.25mm thick laths including top cover, anchoring rod, hasp and staple and one shop coat of primer and erected in position including taking down existing unserviceable rolling shutter complete all as specified and directed.
Ball bearing suitable size for rolling shutters for smooth functioning and removal of steel spring from site including taking down existing unserviceable complete all as specified and directed
Mild steel GI 40mm bore pipe, medium grade for rolling shutter for smooth functioning of old rolling shutter including taking down old unserviceable complete all as specified and directed.
Mild steel GI 50mm bore pipe, medium grade for rolling shutter for smooth functioning of old rolling shutter including taking down old unserviceable complete all as specified and directed.
Steel spring of suitable size for old rolling shutter and including smooth functioning including taking down old unserviceable complete all as specified and directed.
Prepariation of newly steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of old painted steel surfaces over 10cm in width or girth as in steel gate, swan neck fencing posts over perimeter compound wall, gates hangers, steel door etc and applying one coat of synthetic enamel paint with appropriated arrangements complete all as specified and directed.
Rolling shutters top cover fabricated to required shape and size made of 1mm thick (20 gauge) mild steel sheet including necessary fixtures and fastening with one shop coat of red oxide primer of length upto 3.00m including taking down old unserviceable complete all as specified and directed.
Rolling shutters top cover fabricated to required shape and size made of 1mm thick (20 gauge) mild steel sheet including necessary fixtures and fastening with one shop coat of red oxide primer of length exceeding 3.00m but not exceeding 5.00m including taking down old unserviceable as existing complete all as specified and directed.
Re-fixing of loose/broken flat iron side clamps of rolling shutter to any type of wall pillar etc. with and including flat iron, necessary welding work with stainless steel fasteners complete all as specifie and directed.
Gear box assembly for rolling shutter including rod, required nuts, bolts, cleats, crank handle etc. complete of standard make and fixed in position including one coat of primer including removal of old gear box assembly and other accessories including taking down old unserviceable complete all as specified and directed.
Granite slab/ tiles 20mm thick black as in floors/treads etc, set & jointed with neat cement slurry over and including 15mm thick screed bed in cement mortar (1:6) and pointed with white cement with admixture of pigment to match with shade of Granite stone including cutting, grinding and polishing (mirror polish i.e. full granite polish as per local trade practice) complete all as specified and as directed.
Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete all as specified and as directed.
Ceiling board to the ceiling grid by silicone sealant of 500gm pack complete all as specified and directed.
Ceiling board to the ceiling grid by araldite of 500gm pack complete all as specified and directed.
Plywood, 9mm thick, grade BWR, type BB, (ISI marked) fixed with screws, nut, bolts to timber or metal frame work, frequency of fixing of plywood as per operational requirement complete all as specified and directed.
Flex glow sign air force monogram including sticking / paste by pressure application of rubber cement on slant surface in three or more pieces including care to match the photo of monogram without andy depression including 03 nos monogram of required size same as per sample kept in Chandan complete all as specified and directed.
Second class hard wood plain fillets, square, rectangular or triangular in section, clean sawn, se-cured with nail or brads of section exceeding 13 sqcm but not exceeding 25 sqcm and fixed to wall with rewal plag and suitable steeel screws complete all as specified and directed
Prepariation of concrete/stone slant surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint of approved colour and letter writing 60cm wide complete all as specified and directed.
Acrylic sheet/composite panel 8mm thick fixed to aluminium/ steel / wood frame with screws including dismentling/taking down old unserviceable complete all as specified and directed.
Acrylic sheet 8mm thick of any shape and size upto 1.00 sqm fixed to existing aluminium/ steel / acrylic/ wooden frame with screws and appropriate fittings & fixtures with flex glow sign airforce monogram including required taxt as sample kept in Chandan including sticking / paste by pressure application including care to match the photo of monogram without any depression / undulation 6 nos of monogram complete all as specified and directed.
Writing of letters, dashes and directional arrows etc made with 8mm thick acrylic sheet and size of each letter /arrows / dash shall be approx 0.60m high and 0.45m width fixed to existing aluminium / steel / acrylic / wooden frame with screw and appropriate fitting and fixtures with flux glox computerised (light) cut of high intensity of letters such as ex-VAYU SHAKTI 2022 or same as per sample kept in Chandan including sticking / paste by pressure application including on acrylic sheet care to match the photo of monogram without any depression / undulation comptete all as specified and directed.
VAYU SHAKTI Emblem having 4mm thick PVC sheet dia 60cm with flux glow sign including brackets of flat iron 20mmx3mm for electric pole approx 100 to 150mm dia comptete all as specified and directed.
Double legged informatory sign board of size (1.20m x 1.20m) fixed on single frame, both side and meeting back to back on the stainless steel 50mm square pipe. The board are of high intensity grade reto-reflective sheeting of AVERY DENNISOX made out of 2mm thick alcoband sheet/aluminium composite panel sheet confirming to IS-736, colour as approved and stainless steel square pipe of size 45x45x3.65mm or round pipe 50mm dia of thickness 3.65mm with nut and bolt. The lettering will be computerised cut to high intensity grade white sheeting (AVERY DENNISOX) and mechanically fixed on board over verticle post 50mm stainless square pipe, 3.65 mm thick 2.00 to 3.00m long having 2 Nos flat iron strip of strip 40x5 mm, 0.30mm long on bottom and fixed with PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) for fixing of post complete all as specified and directed.
Acrylic sheet 8mm thick of any shape & size fixed to existing aluminium / steel / acrylic / wooden frame with screws and appropriate fittings and fixtures with flex sign Air Force monogram including required text as sample kept in Chandan including sticking / paste complete all as specified and directed.
Dismantling mild steel work of any description as in covers to cable ducts, rafters, purlins etc complete all as specified and directed.
Rolled mild steel as in Joist, channel, tube, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated with Fe-290 (Gde-E-165) complete all as specified and directed.
Mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, wind ties also screwing with bolts, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, necessary welding etc. complete all as specified and as directed.
Rolled mild steel work as in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including necessary welding etc. conforming to Gde E-250 (Fe 410) quality 'A' complete all as specified and as directed.
Mild steel screw bolts 11mm to 15mm dia of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exce 5cm but not exce 10cm long complete all as specified and as directed.
Wind ties for including securing bolts, including all necessary drilling, bolting or riveting, and similar work conforming to Gde E-310 (Fe-410) complete all as specified and directed.
Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and including dismantling asbestos cement, plain or corrugated steel/fiber sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Solar control film 25 micron reflective type (gareware sun control or equivalent) complete all as specified and directed
2nd class hard wood of 40mm thick for boarding in floors planed one side, with butt joints and fixed with nails, nut & bolts complete all as specified and directed.
10mm thick plaster in cement and mortar (1:6) on fair faces of brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
15mm thick plaster in cement and mortar (1:4) on fair face of brick work or concrete surfaces of wall, finished even and fair without using extra cement complete all as specified and directed.
Preparation newly plastered surfaces or unplastered surfase of walls and applying two coats of oil emulsion distemper complete all as specified and directed.
Preparation of newly plastered or unplastered of wall surfaces and applying two coats of cement base paint of approved tint complete all as specified and directed.
Taking down chowkhats or frame (without taking of shutters from the frames), area not exceeding 1.5 Sqm each complete all as specified.
Taking down chowkhats or frame with shutters (without taking off shutters from the frames), area exceeding 1.50sqm but not exceeding 4.00sqm each complete all as specified and directed.
Taking down shutters any description area exceeding 1.00 sqm each but not exceeding 2.00 sqm each complete all as specified and directed.
110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls in repair complete all as specified and directed.
110mm bore PVC (SWR) bend any radius provided fixed as in repair complete all as specified and directed.
PVC stack clamps, including bolts and nuts and securing ends of stays with rubber ring joints to wall or roof for 110mm dia PVC (SWR) pipe complete all as specified and directed.
Point wiring for one light point controlled by one way switch with 1.50 sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade including 1.50 sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated & including suitable size module boxes for housing of modular switches, sockets, regulators including taking down old unserviceable point wiring complete all as specified & directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/Anchor/Formica including machine screws and washer etc for fixing switches sockets etc including 1.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed.
All as per serial item No. 93.00 here-in-before but for one fan point controlled by one switch and regulator complete all as specified and directed.
All as per serial item No. 93.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on same board complete all as specified and directed.
All as per serial item No. 93.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on independent board complete all as specified and directed.
All as per serial item No. 93.00 here-in-before but for One 3 pin 5 amps socket outlet independent but below the switch board of light points in the same vertical plane complete all as specified and directed.
Point wiring for one 3 Pin, 5/6 Amps socket outlet controlled by one 5/6 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated & including suitable size module boxes for housing of modular switches, sockets, regulators including taking down old unserviceable point wiring complete all as specified and directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/Anchor/Formica including machine screws and washer etc for fixing switches sockets etc including 2.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed.
Modular switch 6 Amps, 250 Volt, AC, one way, one module (ISI Marked) fixed as in repair complete all as specified and directed.
Modular switch 20 Amps, 250 Volt, Single Pole, AC, one way with indicator one module (ISI Marked) fixed as in repair complete all as specified and directed.
Modular Socket shuttered, 6 Amps, 250 volts, 2/3 Pin combined, Single Pole, universal India two module (ISI Marked) fixed as in repair complete all as specified and directed.
Modular Socket shuttered, 6/16 Amps, 250 volts, 3 Pin combined, Single Pole, two module (ISI Marked) fixed as in repair complete all as specified and directed.
Modular Fan Regulator, step type, 120 Watt, 2 module, 250 volts grade, (ISI Marked) fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 1/2 Module fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 3 Module fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 4 Module fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 6 Module fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 8 Module fixed as in repair complete all as specified and directed.
Modular Metal flush mounting box of 12/16 Module fixed as in repair complete all as specified and directed.
White colour modular blanking plate, one module blank fixed as in repair complete all as specified and directed.
White colour plates with frame for modular switch of 1 module fixed as in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 2 module fixed as in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 3 module fixed in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 4 module fixed in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 6 module fixed in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 8 module fixed as in repair complete all as specified and as directed.
White colour plates with frame for modular switch of 2 x 6 module fixed as in repair complete all as specified and as directed.
Ceiling rose surface bakelite with two or three terminal PVC/Polycarbonate, isolated body (ISI Marked), 240 volts fixed as in repair complete all as specified and directed.
Stepped type electronic fan regulator, flush type and connecting up, 100 watt, 240 volt (ISI marked) complete all as specified and directed.
LED Panel 36 watt with 2ft x 2 ft slim panel 595X595mm with super bright recess mounting LED Slim ceiling light with white powder coated extruded aluminium housing and highly efficient light smoothing optics to deliver superior illumination including LED driver and fixing in recess ceiling suitable size of aluminium strip size as required for fixing of LED fitting complete with all accessories prewired fixed on ceiling and connecting up complete with 3 core flexible cable of size 23/0.0076 including taking down old unserviceable fittings complete all as specified and directed.
Sub main wiring with 6.00 sqmm, Single Core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 volts grade conforming to IS 694 including 6.00 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit including taking down old unserviceable submain wiring complete all as specified. Note : Two run of 6.00 sqmm cable and one run of 6.00 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
Sub main wiring with 4.00 sqmm, Single Core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 volts grade conforming to IS 694 including 4.00 Sqmm Single Core PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit including taking down old unserviceable submain wiring complete all as specified. Note : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
MCB, SP, 6 to 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles including disconnecting & taking down old unserviceable MCB, complete, all as specified & directed.
MCB, SPN, 40 to 63 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete, all as specified & directed.
MCB, TPN, 40 to 100 Amps rating, with over load and short circuit protection 'B' curve and rupturing capacity 10 kA, 415 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete all as specified & directed.
MCB Protected Socket (Modular AC Box, Metal clad box) Two Module, Single Pole, 20 Amps, repturing capacity 10 kA and neutral enclosure in sheet steel with a two pin and earth plug and socket including taking down old unserviceable complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB SPN 8 ways and neutral 240 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Single Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable DB complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB TPN 4 ways and neutral 415 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable DB complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No. 3 of SSR Part-I and connection to main switch board/Test point/ panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exceeding 50 metre, charcoal and salt in alternate layer 15cm thick all around the earth plate electrode, Mild Steel Funnel with wire mesh, 20mm bore, GI pipe medium grade, 1.50 metre long for watering and 15mm bore, GI pipe light grade, 7.50 metre long for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:2:4) type B-1, using 20mm graded stone aggregate with angle iron 40x40x5mm frame 60mm thick RCC cover with 6mm steel bars 100mm centre to centre both ways etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : (i) PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) If earth resistance of earthing is not found satisfactory it will be redone by the contractor on his risk and cost.
Supply, installation and testing electric water heater, storage type, steel body with copper inner tank and heating element upto 2 KW, capacity 25 litre BEE 5 star rated complete with all assessories such as safety valve, thermostate, NRV, PVC connection pieces etc omplete all as specified and directed.
M/s Ramesh & Company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .