| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr Quoted ₹1.3 Cr | L1 | Accepted-AOC Qualified |
| 2 | L2₹1.3 Cr+₹4.0 L (3.14%)Rejected-Finance | ₹1.3 Cr+₹4.0 L (3.14%) | L2 | Rejected-Finance High Amount Quoted |
| 3 | L3₹1.3 Cr+₹4.6 L (3.62%)Rejected-Finance | ₹1.3 Cr+₹4.6 L (3.62%) | L3 | Rejected-Finance High Amount Quoted |
| 4 | L4₹1.4 Cr+₹8.0 L (6.27%)Rejected-Finance JHARIA BENIGANJ HARDOI | BENIGANJ | HARDOI | UTTAR PRADESH | ₹1.4 Cr+₹8.0 L (6.27%) | L4 | Rejected-Finance High Amount Quoted |
Tender Value
₹1.6 Cr
EMD Value
₹8.0 L
Closing Date
25 Jul 2023, 2:30 pmClosed
Excutive Engineer
GDA Office, Taramandal, Gorakhpur.
Please refer Tender documents
2023_GORDA_820203_1
12/GDA/2023-24/04072023
Open Limited
Electrical Works
Item Rate
90 days
Taramandal
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,950
₹8.0 L
8 Aug 2023
13 Jul 2023
25 Jul 2023
13 Jul 2023
25 Jul 2023
13 Jul 2023
13 Jul 2023 - 25 Jul 2023
Amount
S/F of Double pole structure of S.P.-55 S.T. pole 11.00mtr. Long complete with all accassories including 2 no. Channal with paint, grouting &making plinth above 20cm G.L. in 1:3:6 C.C. with excavation and back filling etc. complete in all respect.P.S.R.
Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 2000mm, outer Dia 50mm inner Dia 25mm, terminal Dia 12mm, outer Gi Pipe of 16 swg and inner Gi Pipe 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM having anti corrosive & conductive property eith 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I strip, upto switch board (from apron to switch board, the cost of G.I.strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housong. Make: As Approved in U.P. P.W.D., & C.P.R.I Certified.SOR-2018/ 725 (A)
S/F of danger board with clamp and bolt fabricated from 10gauge MS sheet etc compelete as per I.E rules F/F of number plate with clamp & bolt including numbering with paint etc complete as per E/I. rule.PSR
Earthing of O/H/ line pole with 2.5 mt. long 20 mm dia G.I. rod including the cost of 7/16 S.W.G. G.I. earth wire labour & T&P etc. required for proper completion of work as per dorection of E/I.PSR
S/F of cable root marker CC make complete in all respect as per direction E/I. PSR
S/F of 6 inch dia GI pipe complete in all respect as per direction of E/I. PSR
S/Painting of pole with 2 coat of "Al" paint over one coat of red oxide including cleaning of dust vermin & making good complete in all respect. As per direction of E/I.PSR
Supply and laying of 3 core standered aluminium conductor 240 sqmm XLPE (cross linked polyethylene) insulated PVC bedded galvanised flat steel strip armoured cable confirming to I>S. 7098(part-2 with latest amendments) 11000 volts grade complete in all respects the armouring of the cable shall be property connected with the earth conductor by clamps with brick sand etc. make asper UPPCL approved (make Polycab & havells).PSR
(o) (ii) 240sqmmx3 core (Approved Rate)
S/F of outdoor type cable end termination jointing kit suitable for XLPE cable etc all complete. PSR
(i) 240 sq mm. (outdoor)
(ii) 240 sq mm. (intdoor)
S/F of 11KV, RMU- 11KV, 630A, 21KA for 3 Sec, SF6 Gas Insulated and Non-Extensible, Outdoor Ring Main Unit with 2 Nos Manully operated load break, 1 Nos. Manully operated vacuum circuit breakers.Configuration (CVVV) Four Way (C-01 Incoming, 03-V Outgoing) (MAKE)ABB/Senider/siemens/Heavels (With Plinth)
Laying of 33/11 KV XLPE cable 300/240 sqmm sqmm throught HDD Method sd per Resspo Norms.(550-170) = 380. (UPPCL)
Dismentling of rail / S.T. pole including removing of channel disc insulator, pin insulator,light etc complete in all respect as per direction of E/I. PSR
Dismentling of ACSR condutor complete in all respect.
Cartage of old materials from site to uppcl store including loading /unloading. PSR
S/F of 11 KV 240 sqmm XLPE insulated straight through joint kit heat srink M-seal/ Raychem make complete in all respect as per direction of E/I. (8746.00+3540.00) = 15982.00 (UPPCL)
Dismentling of doble pole Structure ST pole.
Excavation in foundaction for cabile trunch work size 1000x800mm (Average) for electrical trench M-25 RCC. including cable hanger & RCC tranch cover Or into the plinth and remuval and disposal surples earth as directed by the Engineer incharge with in a leed of 30m from foudaction trenches as per diraction of the E/I. and etc complect work. (Approved Rate as pae disign)
M/S SWATANTRAVEER
Dharmendra Kumar Srivastava
M/s Anil kumar singh
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Restricted Tender
This is a Open Limited tender. Documents are accessible only to bidders authorized by the issuing authority on the government portal.
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .