Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | ₹1.6 Cr Quoted ₹1.7 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹2.0 Cr+₹32.4 L (19.4%)Rejected-Finance OFFICE NO 2 GROUND FLOOR CO OP HSG SOCIETY SBS ROAD COLABA MARKET MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹2.0 Cr+₹32.4 L (19.4%) | L2 | Rejected-Finance Other than being lowest |
| 3 | L3₹2.1 Cr+₹42.2 L (25.2%)Rejected-Finance | ₹2.1 Cr+₹42.2 L (25.2%) | L3 | Rejected-Finance Other than being lowest |
| 4 | L4₹2.1 Cr+₹42.6 L (25.5%)Rejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | ₹2.1 Cr+₹42.6 L (25.5%) | L4 | Rejected-Finance Other than being lowest |
| 5 | L5₹2.2 Cr+₹51.1 L (30.5%)Rejected-Finance ROOM NO 206 PART III GANESH MURTI NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹2.2 Cr+₹51.1 L (30.5%) | L5 | Rejected-Finance Other than being lowest |
Tender Value
₹2.3 Cr
EMD Value
₹3.0 L
Closing Date
8 Apr 2024, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
SPECIAL REPAIR TO BUILDING NO P37 INCS BUILDING AT OLD NAVY NAGAR UNDER GE NW NAVY NAGAR COLABA MUMBAI
2024_MES_641041_1
8180/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
270 days
GE (NW) Navy Nagar
Asper Tender Documents
7 documents required · 7 mandatory
₹2,000
Yes
GE (NW) Navy Nagar
₹3.0 L
Yes
10 May 2024
6 Feb 2024
10 Apr 2024
6 Feb 2024
8 Apr 2024
27 Mar 2024
6 Feb 2024 - 22 Feb 2024
Amount
Material & Labour for drilling and fixing Rohibb teflon in RCC members, including drilling holes of 12 mm dia , 50 to 100 mm deep holes in structural member at the interval of 500mm c/c in staggered manner or as directed by Engr In Charge in RCC structural element. Work shall be carried out as under :- (a) Cleaning of holes - cleaning the holes by air blower prior to fixing nozzles (b) Fixing of nozzles - Insert 12 mm dia Rohibb teflon nozzle into cleaned holes. External end of nozzles to be machine to recieve outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for 12 hrs (c) cutting of nozzles - Cut the nozzle by chisel after completion of grouting without damaging structural element complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Material & Labour for injecting of site cement slurry grout in the ration 1:2 ( 1- Cement 2- Water ) including supper plasticiser (Super com -100) 250 ml/50 kg. Mixing shall be done mechanical mixer continously stirring machnically to keep cement particle in suspention .Injection of approved/specified grout by means of pump at a pressure of 0.5 Kg /cm sq etc complete till the grout mix flows out out from the nozzle indicating complete filling of grout in the holes drilled (for repai r to wall and slab) complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Material & Labour for injecting viscosity MONOPOL (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzle refused to accept the grout, including mixing of material component ( part A & B) in the required qty as per manufactures instruction by weight batching. Grouting maintain the presssure at exit (0.5 to 1 1.kg/cm2) by monitering pressure guage at exit . Grout at material through prefixed nozzle in the structural element @ 100 ml per nozzle. Repeat the process for all nozzle (Columns and beam) complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Material & Labour for chipping, removing carefully concrete work by low impact hammer, breaker without damaging the structure and cleaning and disposal of debris out side the premises etc complete as directed by Engr-in-charge. Hard concrete should not be removed by force complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Material & Labour for Building up the profile of structrual members by using latex B2 modified air cured mortar system in damaged areas (1 part cement 3 part sand with 10% epoxy latex based bond by wt of cement - 0.5 w/c ratio) in upto 40mm thickness including leveling profiling etc. It should be built up each layer not exceeding 20mm thickness with epoxy latex based bond coat before every layer Complete all as specified and directed by Engr-In- Charge.(upto 06 storey ht of bldg) (Note : Rate includes the rate of bond coat. No separate payment will be paid for bond coat).
Material & Labour for carry out application of BI Polar migratory corrosion inhabitor EPCO KP _ 100 Protectssil CIT/Ferogard 903 on concrete surface (this inhabitor shall have migratory kind of property which permit the material to migrate to a vertural extend of 100 mm , through pores of concrete inhabbting the corroser and depassivating the elctro chemical reaction it should have property to attack anode as well as cathode which is purely alkaline in nature (Ph 9.5) so it has no carcinogen activities with concrete complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Material & Labour for cleaning existing reinforcement with wire/rotary wire brush, making the surface free from loose material dirt etc, complete applying two coats of alkaline rust converting primer (i.e. rust remover) FEOVERT conforming to ASTM-B-117, on the rebars including cleaning the reinforcement , wire brushing to remove loose rust spalls with time interval 6 hrs between the coats and applying protective coating (IPNET - RB complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Material & Labour for providing and applying two coats of anti-rust protective coating in the form of Acrylic Polymer mixed with Cement in 1:1.5 proportion (1 part polymer and 1.5 parts Cement) on rebars after cleaning of rust scales as per manufacturers instruction (measurement on the basis of exposed concrete area) complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Material & Labour for providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster or micro concreting conforming ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bonding between old concrete and new concrete complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Material & Labour for providing and applying jacketting around columns/beams with micro concrete (Molith-MC) M-40 including all lifts, shuttering , drilling holes and fixing shear anchor as per specification complete. (Note : (a) Reinforcement shall be measured and paid seprately. b) Rates quoted are deemed to include jacketing micro concrete (upto 06 storey ht of bldg)
Use and wase of formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Use and wase of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Material & Labour for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
All as per item No 13 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Providing and fixing MS/TS dowel pins/staple/shear pins including drilling holes in concrete and providing labour including polyster resin based grouting materials for grouting the pins sourced from manufacturer's, complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Material & Labour for replacement of steel reinforcement with TMT bars of appropriate size where 20 % of cross section is reduced including dismantling of rusted steel including application of rust convertor FEOVERT and applying protective coating IPNET - R B Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Taking down cement plaster of any discription including racking out joints hacking for key scrubbing down with water & removed debrises out MD land including necessary working platform (scaffoldings) and safety measures Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Material & Labour for Sand faced cement plaster 20 mm thick in two coats using factory manufactured pre mix/ready mix having minimum composition of C:S : 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechnIcal mixing with water in a metalic tray only to make good consistency as per the specification of the Manufacturer and guniting using compressor over exterior masonry and concrete surfaces with base coat of 15 mm thick and finishing coat of 5 mm thick ( finishing coat shall be mixed with MONOBOND @ 10% of weight of ready mix plaster ) including using richer mix for making corners, at all floors and level, including making grooves of existing size wherever required, including cleaning the surfaces, curing etc. including necessary working platform (scaffoldings) and safety measures Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Material and labour rendering 15mm thick in CM (1:6) on wall finished even and fair without using extra cement as in patches including necessary working platform (scaffoldings) and safety measures Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Material and labour for rendering 10mm thick in CM (1:3) on ceiling finished even and fair without using extra cement as in patches including necessary working platform (scaffoldings) and safety measures Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Material and labour for applying one coat of Rust remover and rust passivator on exposed reinforcement surfaces at any height all as specified and dirceted. Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
Supply only liquid water proofing compound MONOBOND Complete all as specified and as directed by Engr-in-Charge
Material and labour applying three coats of white wash on new surfaces including preparation of surfaces as in wall Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
-ditto- all as per item No 23 above but on old surface of wall including complete removal of existing surface complete all as specified and directed.
Material and labour for applying two coats of white wash on new surfaces including preparation of surfaces as in ceiling Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
-ditto- all as per item No 25 above but on old surface of ceiling including complete removal of existing surface complete all as specified and directed.
Material and labour for applying two coat of Acrylic emulsion on new surfaces including preparation of surface over one coat primer over 3mm thick wall care putty on wall Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
-ditto- all as per item No 27 above but on old surface of wall including complete removal of existing surface complete all as specified and directed.
Material and labour for preparation of new surfaces of walls, soffits and fascias of chajjas etc and applying two coats of rain coat over a coat of suitable primer as per manufacturers instructions including necessary working platform (scaffoldings) and safety measures Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg). Note - Covering of rain coat and primer shall be as per manufacturers instructions.
-ditto- all as per item No 29 above but on old surface including complete removal of existing surface and filling the cracks with cracks filling compound of DR Fixit complete all as specified and directed.
Material and labour for applying two coats of synthetic enamel paint including preparation of old wooden surfaces over 10cm width/girth complete all as specified and as directed by Engr-in-Charge (upto 06 storey height of bldg).
Material & Labour for preparaing of old steel surfaces of any description and applying one coats of synthetic enamel paint Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Removing demolished materials outside MD land to a distance exc 5 Km but n exc 15 Km. Complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material & Labour for 20-25mm machine cut kota stone slab single piece length as in in riser, steps, skirting, dado, window cill and pillar laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishing including rubbing and mirror polishing (Note : Kota stone single pice of Cill will be fixed in two steps) Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Rounding to edges of stone slabs one edge,such as in steps,cooking plateform,and other similar situations Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material & Labour for Non Skid ceramic coloured tiles 7 to 8 mm thick area of each tile exc 0.18 Sqm but n.exc 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 20 mm thick in CM 1:4 for laying floor finishing Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material & Labour for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete including Screed bed or bedding layer of mortar 20 mm thick in CM 1:4 for laying floor finishing Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material & Labour for Non Skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) exc 0.11 Sqm but n.exc 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishesin Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material & Labour for Glazed colour ceramic tiles in vertical surfaces 300 x450 x 6 to 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick in CM 1:4 backing coat to tiles/stone Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material and labour for 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platform and like laid over and including 20mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with admixture of pigment to match the shade of marble slab including grinding and polishing complete complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material and labour for Granite slabs 18-20 mm thick Granite (of any type) work (table rubbed and polished) on wall surface laid over and including 15 mm thick backing coat in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including grinding and polishing Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing in repair for 25 mm curtain rod fancy type anodised aluminium alloy with fancy brackets and knobs complete all as specified and directed.
Taking down chowkhats or frames but with shutters (without taking off shutters from the frames) not exc 1.5 sqm each Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Taking down chowkats with shutter (without taking shutter from the frame) exc 1.5 sqm each but not exc 4 Sqm each Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing powder coated anodiesd alumunium frame/track or shutters for windows, ventilators etc with one or more reabetes incl joining cleat for fixing etc. fixed or sliding type/louvered window or ventilator without sash bar,aluminium including necessary joining cleats glazing clips rubber packing,anodised aluminium snap beadding screws locking arrangements etc. including necessary working platform (scaffoldings) and safety measures Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Ditto All as per item No 47.00 above but (upto 06 storey ht of bldg).
Supply & fixing for aluminium grill with suitable aluminium anodised frame section of F section of size 23.4x15.3x4 mm thick manufactured by M/S Deco grill pattern DG-102(7.50 mm dia and aparture 50 mm ) Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply & fixing for Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples or wooden/ Aluminium beadding all as directed.
Supply & fixing in repair Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples or wooden/ Aluminium beadding all as directed.
Supply and fixing 4 mm thick figured glass pin headed type and glazing with aluminium and neoprene beads in sqr not exc 0.50 sqm in each pane Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing 4 mm thick plain sheet ordinary qualityand glazing with aluminium and neoprene beads in sqr not exc 0.50 sqm in each pane Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 90 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp?ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed by Engr-In- Charge.
Supply and fixing Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges shall be paid separately)
Material and labour for 2nd class hard wood (SAL) plain, solid straight chowkats and frames, wrought framed, rebated on the solied, rounded or chemfored, put together with glue pinned at joints. Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material and labour for 30mm thick Flush shutters, solid core construction, with particle board core both face is covered with decorative face veneer with lipping/frame to match. Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material and labour for 2nd class hard wood 35mm thick factory made plain framed, panelled shutters (two panels) with lock rail and panel of 9mm BWP commercial or 12mm veneered particle board with commercial veneer on both faces the size of rail and stile as per IS 1003 (Part-I) kiln seasoned and chemically pressured treated complete all as specified and directed by Engr-In- Charge.
Material and labour for 2nd class hardwood 30mm thick skeleton shutters, open rebated and prepared to receive wire mesh edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing mesh etc, sizes of members of shutters as specified in SSR complete all as specified and directed by Engr-In- Charge.
Material and labour for 2nd class hard wood plain filetting square wrought fixed with screws etc of cross section area exceeding 13 sqcm and not exc 25 Sqcm Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material and labour for cutting holes in brick / stone walls in cement mortar exc half & n.exc. one brick depth of embedded portion of hold fast complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material and labour for PCC (1:3:6) type C-1 (20mm graded agg) for fixing of hold fast complete all as specified and directed by Engr-In- Charge.
Material and labour for applying two coats of synthetic enamel paint over primer including preparation of new wooden surfaces over 10cm width/girth Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing in repair 300 mm long mild steel ordinary rat tail rod patterns springs including roller and roller plate Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing 100mm size stainless steel butt hinges.
Supply and fixing 100 mm long aluminium anodised barrel tower bolts of extruded section.
Supply and fixing 150 mm long aluminium anodised barrel tower bolts of extruded section.
Supply and fixing 100mm size extruded aluminium alloy handles, fabricated type anodised.
Supply and fixing 150mm size extruded aluminium alloy handles, fabricated type anodised.
Supply and fixing for 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Supply and fixing in repairs Floor door stoppers of aluminium alloy body and tongue anodised with hard drawn steel spring fixed in floors of overall length of cover plate 150 mm complete all as specified.
Demolition of cement or lime Concrete (unreinforced) of any description and in any position not otherwise specifically provided for incl china mosaic & WC Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material and labour for roughening the surfaces of old cement concrete floor by picking, cleaning and washing down with water to remove dust etc. rendering 15 mm thick in CM 1:3 mixed with water proofing compound and applying two coats of hot bitumen 85/25 grade @ 1.70 Kg/Sqm over vertical sides of sunken floors. (Note : WPC shall be measured and paid seperately)
Material and labour for cement concrete 1:7:12 using 40mm graded stone aggregate in sunken floor 150mm thick complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material and labour in repairs Cast iron nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) 100 mm dia Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Taking down Cast iron soil waste pipe (any size and patterns) mouldings all fittings heads, shoes, bends including necessary working platform (scaffoldings) and safety measurs Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing cast iron sand cast pipes in any length with or without cement mortar laid on walls of 100 mm bore including necessary working platform (scaffoldings) and safety measure Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing cast iron sand cast pipes in any length with or without cement mortar laid on walls of 75 mm bore including necessary working platform (scaffoldings) and safety measurs Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing CI Bends (any radius), diminishing pieces or tapers (larger bore measured) with oval doors of 100 mm bore complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing CI Bends (any radius), diminishing pieces or tapers (larger bore measured) with oval doors of 75 mm bore complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing CI Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors of bore 100 mm Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing CI Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors of bore 100 mm Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing CI Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors of bore 75 mm Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) including necessary working platform (scaffoldings) and safety measurs Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing 160mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and fixed to walls including necessary working platform (scaffoldings) and safety measurs Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing PVC bends of 160mm bore with oval acess door Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to trap/drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc complete including making good to floor Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing in repair CP Jet with 600 mm long connection pipe fixed to water closet pedestal pattern complete all as spfd & directed fixed in repairs.
Supply and fixing in repairs PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets of 10 lit capacity Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing in repair Vitreous China wash basin, white, flat back, size 630x450mm counter sunk type exc taps, waste, chain and plug and porcelain stopper but including brackets Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing in repair 15 mm bore pillar taps, with capstan heads, chromium plated, Fancy and with 300mm long Swan neck type screwed down for pipe, high pressure ,complete all as specified and directed.
Supply and fixing in repairs PVC Connectors 15 mm size with PTMT nuts of length 600 mm complete all as specified.
Supply & Fix in repairs Vitreous China Full stall urinal complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material and labour for Urinal spreader of brass chromium plated suitable for fixing with 15 mm bore pipe complete all as specified.
Demolition of brickwork built in cement mortar including removal of unservicable bricks from MD land Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material and labour for brick work of sub class 'B' brick built in cement mortar 1:6 complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing in repairs brass chromiuim plated Tubular towel rails 20 mm dia D type 60 cm long between flanges complete all as specified.
Supply and fixing grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed by the Engr-in-charge
Material and labour for removal of existing water proofing treatment from the roof of any description, including demolition of PCC padding and plaster of any thickness and description and in any position cleaning with wire brushes and finally cleaning with water to remove dirt complete all as specified and directed by the Engr-in-charge (upto 06 storey ht of bldg)
Material and labour for Plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) mixed with MONOBOND as per manufactures instructions. Before laying concrete, surface shall be cleaned and a bond coat of slurry with cement to be applied. All cracks in slab to be openend in 'V' groove and filled with a Polymer Morter complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material and labour for 20mm thick rendering in CM 1:4 mixed with liquid water proofing compound MONOBOND @ 200ml per 50 Kg bag of cement on fair faces of brick or Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg)
M&L for providing water proofing treatment on roof including following : - (a) Applying bitumenous primer @ 0.50 litres per sqm over cleaned and dry roof surface including parapet (b) Material and labour for applying a coat of blown bitumen 85/25 grade @ 1.50 Kg per Sqm over priming coat . (c) Providing and laying 4mm thick APP modified polyester reinforced water proofing memberane with minimum weight of 3.5 Kg/Sqm , as specified. The APP membrane shall be laid using torch-on application with minimum 10 CM side overlap and 15 CM end overlap. The APP memberane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant. (d) Applying a coat of blown bitumen 85/25 grade @ 1.50 Kg per Sqm over priming coat over APP membrane. (e) Laying cement concrete tiles 25 cm x 25 cm x 20 mm thick with grey cement and pigment, laid over and including 20 mm thick screed bed in cement mortar 1:3 , set, jointed and pointed in neat cement slurry over polyoropylene/ polyster non oven geotextile fabric of 50 GSM. Note - (i) Irrespective of lap the net covered area shall only be measured and paid. ii) The laying of membrane shall be got done through an authorised applicator of manufacturer of the membrane.
Material and labour in repairs suspended false ceiling system using fully perforated 12mm thick micro tegular edged GRG ( Glass Fibre Reinforced Gypsum) tiles of size 595mm x 595mm of approved texture, design and pattern having moisture content less than 2% humidity resistance of 99%, NRC 0.50 to 0.75 as per IS: 8225: 1987 comprising of GI power coated main runner of dimension 39mm x 24mm x 0.80mm thick (thickness comprising of GI/0.4+pppcgs/0.3mm & weight of runner 1.35 Kgs for 3600mm length ) crosss tee of dimensions 29mm x 24mm x 0.80mm thick wall angle 22.2mm x 22.2mm x 0.65mm thick (thickness comprising of GI/0.3+pppcgs/0.3mm & weight of runner 0.70 Kgs for 3050mm length ) with and including 6mm thick HPSC(High pressure steam cured ) pre-primed, self embossed textured designed board, water resistant, termite resistant, fire resistant for insulation and accustic purpose to be placed in the grid sustem duly suspended with 6mm dia GI bars hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips (Wt 0.007 Kgs/Clip) hold down clips (Wt 0.0035Kg/Clip) including taking down u/s one complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings
Material and labour pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including making grooves of minimum 75 mm into brick walling and inserting the sheets into these grooves incl making good using CM 1:3 complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by the Engr-in- charge
Supply and fixing Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming. Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing mild steel Framed brackets of angles or tee with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles as necessary gusset plates, riveting etc conforming to Fe 410 or Fe 310-0 Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing rolled section as in main and cross beam, hip and jack rafters, purlins where connected to common rafter and running rails etc complete conforming to Fe-410- W(Gde?E-250) quality?B Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material and labour for stainless steel special alloy grade 304 pipes as in railing including required cutting, notching Argon welding, riding and drilling counter sunk holes and bending to required shape by mechanical means in factory as per site requirement without forming wrinkles and butting and polishing Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material and labour Steel work in tubular railing including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and fixing 10 mm dia 100 mm long dash through fasteners bolts fixed in concrete or brick work to hold brackets etc complete
Material & Labour for preparaing of new steel surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Dismantling stone slab including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
Material and labour for Machine pressed precast coloured glazed concrete interlocking paver block with grey cement & pigment, glossy finish (reflective type) any shape and size (as approved by GE) confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, as in pavements to required level & gradients, set, jointed with clean dry sand and sealing the ends using PCC 1:2:4 etc complete. Note- PCC and sand will be measured and paid separately.
Material and labour for Sand filling under floors or in foundation including watering and consolidation etc complete all as specified.
Supply and fixing 4mm dia GI wire of heigh yeild strength including necessary hooks to hold in walls plugs complete all as directed.
Taking down Shutters of any description n exc 1 Sqm each complete all as specified.
Taking down Shutters of any description exc 1 Sqm and n exc 2 Sqm each each complete all as specified.
Material and labour for 18-19mm thick Block boards, grade 1 quality, exterior grade, decorative type with decorative face veneer on both faces fixed with screws to timber frame-work including teak wood lipping, 6mm thick fixed with nails as in Cup board shutter and shelf complete all as specified and directed.
Material and labour for ATT at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material and labour for Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material and labour for ATT at junction between floor and wall using emulsion @ 0.50 litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Grubbing up and uprootinng of trees / plants from external walls of bldgs upto 12 storyed height pouring muratic acid for burning risidual roots in any. Racking out the dead roots from plants / concrete joints upto its penetrated portion and filling with PCC (1:2:4) 12.5 mm graded aggregate and finishing the surface with 15mm rendering in CM (1:4) including necessary hanging arrangement complete all as specified and as directed.
Demolition of reinforcement cement Concrete of any description and in any position not otherwise specifically provided for Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Material and labour for Reinforced cement concrete (nominal mix) 1:2:4 type B0 (using 12.5mm graded stone aggregate) for kitchen platform, Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like Complete all as specified and as directed by Engr-in-Charge (upto 06 storey ht of bldg).
Supply and Fixing steel water tubing, galvanised, Medium grade in short piece/ any length with all fittings such as nipple, union, socket, elbow, bends, fixed to wall in shafts upto 06 storey ht of bldg including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces including necessary scaffolding and safety measures complete all as specified and directed by Engineer-in-charge.
50 mm bore
40 mm bore
25 mm bore
15 mm bore
Supply and fix gun metal gate valves (ISI marked) 50 mm with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fix in replacement of gun metal gate valves (ISI marked) 15 mm with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fix in replacement of Stop valves (ISI marked) 15 mm bore, fancy type, chromium plated (concealed type) cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron/CPVC pipe or for unions and fixed complete all as specified and directed.
Supply and fix in replacement of Fancy type Bib taps Chromium plated 15 mm bore surface fixing, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
Supply & fixing PVC loft tank (LDPE) of capacity 275 ltrs, ISI marked, Company name embossing/Painting on tank with complete fitting including 03 Nos adopter with washer for inlet/outlet,over flow as per manufactureres instructions complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC profile suitable for 275 ltrs loft tank including fixing of aluminium channel around the profile complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections,ladders for over head tanks,base for supporting of loft tanks including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Supply and fix bronze pressure reducing valve suitable for 40 mm bore GI pipe with diaphram cover, spring clamps, cast iron body scatting and adjustable screws and stop valve of chromium plated carbon steel strainer, screw of stain less steel for domestic water supply, suitable for inlet pressure as per IS-7939, including GI pipe connection as required complete all as specified and directed.
Supply and fix Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete suitable for 15 mm dia pipe all as specified and directed.
Supply and fix in replacement of shower rose CP 125mm dia swivel type suitable for 15mm bore CPVC tubing complete all as specified and directed.
Supply and fix in replacement of air Shower arm 15 mm size, 195mm long with bend of 45 degree with flange of PTMT any colour (Minimum weight 40gms) complete all as specified and directed
Supply and fix in replacement of brass float valve (ISI marked) high pressure with polythelene float (flat) and fly nut complete screwed for GI pipe 15mm bore including necessary GI fittings such as elbow, reducer, nipple etc. complete all as specified and directed
Taking down old unserviceable GI tubing of sizes from 15/25/40/50 mm dia complete all as specified and directed
Taking down old unserviceable Gate valves/stop valves/Bib taps/PRV/Mixer/Shower rose/Shower arm of any size complete all as specified and directed
Taking down old Loft tank with profile complete all as specified and directed
Dismantling of old iron material complete all as specified and directed
Taking down copper/ aluminium point wiring ie. light, fan, socket or power/points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors, etc.
Material and labour for point wiring conforming to IS: 732:1989 with PVC insulated unsheathed single core multistranded copper conductor 1.5sqmm, 1100Volts grade cable, FRLS conforming to IS: 694: 1990, passing through and including PVC casing capping of suitable size including all accessories and provision of PVC modular boxes for mounting switches, switch socket, fan regulator etc, as directed by Engineer-in-Charge including one run of 1.5 sqmm size PVC insulated, unsheathed, multistranded FRLS copper conductor cable for continuous earth conductor and connecting to earth dolly for the following :- Note : Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm ii) (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green
One light/Exhaust/Ceiling fan point controlled by one switch.
One 3 pin switch socket combination 5 Amps on the same board with other switches.
One 3 pin switch socket combination 5 Amps, independent.
All as per item No. 146 here in before but with 2.5 Sqmm copper conductor with 2.5 Sqmm cable for earth conductor for one 3 pin 15 Amps socket outlet controlled by one switch. Separate circuit shall be drawn from MCB. No taping from light circuit.
Supply and fixing modular switch piano, 1 module, single pole one way 6 Amp.
Supply and fixing modular switch piano, 1 module, single pole one way 16 Amp.
Supply and fixing modular socket 2/5 pin, 2 module, 6A, ISI marked, 230 volts.
Supply and fixing Socket 6/16A, 6 pin, 2 module, ISI marked, 240 Volts, all as specified.
Supply and fixing modular stepped type fan regulator, 2 module, single pole one way. 230 volts ISI marked and connecting up complete.
Supply and fixing ceiling rose surface bakelite 65x50 mm with 3 terminals.
Supply and fixing modular PVC surface box 8 module for mounting of modular switches and blank plate.
All as per Item No- 154.00 above but of modular PVC surface box, 6 module.
All as per Item No- 154.00 above but of modular PVC surface box, 4 module.
All as per Item No- 154.00 above but of modular PVC surface box, 3 module.
All as per Item No- 154.00 above but of modular PVC surface box, 1/2 module.
Supply and fixing modular white cover plate with frame, 8 module.
Supply and fixing modular white cover plate with frame, 6 module.
Supply and fixing modular white cover plate with frame, 4 module.
Supply and fixing modular white cover plate with frame, 3 module.
Supply and fixing modular white cover plate with frame, 1 or 2 module.
Taking down unserviceable FTL and supply and fix Slim LED intigrated batten of 20Watt 4ft coolday light with powder coated CRCA decorative patti prewired complete with two Nos of PVC box of size 75x75x20mm for mounting light fittings including new ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x20mm complete.
All as per Item No 164.00 above but Slim LED integrated batten of 10 Watt 2ft complete.
Taking down old Main switches/MCB DB any way, any type complete all as specified and as directed.
Supply and fixing MCB DB SPN confirming to IP 43-IK 09 with acrylic door, 8 way complete with din rail, Neutral and Earthing bar complete and making good the disturbed surfaces.
Supply and fixing MCB SPN, 10 to 25Amp, 10KA, 230Volt. complete all as specified and as directed.
Supply and fixing MCB, single pole, upto 20Amp, 10KA, 230Volt. complete all as specified and as directed.
Material & labour for sub-main wiring conforming to IS: 732:1989 with 2 runs of 6 Sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded conforming to IS: 694:1990, drawn through and including heavy grade PVC conduit not less than 25 mm bore with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 6 Sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains connected with thimble including taking up/down old unserviciable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) 2 runs of 6 Sqmm cable, One run of 6 Sqmm earth cable and PVC conduit shall be measured and paid as one length only.
Taking out unserviceable ceiling fan and deposit to MES Store, supply and replacement with ceiling fan 230V, 50 Hz, AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as specified.
Supply and fixing in repairs Exhaust fan, 4 blade,steel body, heavy duty, double ball bearing, 230V, 50Hz,300mm sweep having power input 70WS speed 1440RPM, with protective bird guard including connection as required at site with flexible copper cable all as per specified and directed.
Taking down deterioted louvers from site and supplying and fix new louvers made out of 16SWG GI sheet with machine pressed cut for horizontal ventilation suitable for 300mm sweep exhaust fan complete all as specified and as directed by Engr-in-Charge.
Material and labour for earthing with galvanised steel earth plate electrode 600mm x 600mm x 6 mm burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth not less than 1.5 mtr below ground level connected to the connecting GI strip 32X6 mm and including GI pipe 40 mm dia light grade for protection to the extend of 7.5 mtr as earthing lead by means of GI nuts, bolts as per connecting to equipment with provn charcol and salt complete all as per electric plate No 3 of SSR Part-1 including PCC chamber with RCC cover watering arrangement with GI pipe 20 mm dia medium grade and MS funnel, including excavation and earth work and returning, filling in including ramming and removal of surplus soil and testing on completion complete.
Material and labour for sub-main wiring conforming to IS: 732:1989 with 2 runs of 2.5 Sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded conforming to IS: 694:1990, drawn through and including concealed heavy grade PVC conduit not less than 25 mm bore with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 2.5 Sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains connected with thimble including taking up/down old unserviciable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) 2 runs of 2.5 Sqmm cable, One run of 2.5 Sqmm earth cable and PVC conduit shall be measured and paid as one length only.
Supply and fixing junction box of size not less than 4x4 inch with connector encloser, 3 terminal/ PVC/ polycarbonate, isolated body including taking out old one.
Supply and fixing in repairs LED 45 Watts building street light in Aluminium PDC housing, toughened glass cover in IP66 protection with 3000 (k) including connecting light with three core copper wire from connector or ceiling rose.
Supply and fixing street light bracket bend to shape made as required of 25mm dia, GI pipe light grade fixed to pole/ Wall including Material and labour for fixing with the help of flat iron clamp with the help of nuts and bolts for fixing of street light fitting on the wall complete after taking out old U/S one all as specified and as directed.
Supply, Fixing, testing and commissioning of XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 Volts grade with ISI mark fixed on wall suitable size PVC/Steel clamps after taking down old unserviceable and removal of existing rusted/broken clamps as per directed by Engr-in-Charge.
16 sq mm, 4 core
25 sq mm, 3.5 core
Material and labour for snap on trunking system with cover, angles, bends and all accessories and fitting of size 50x80mm on wall Complete all as specified and directed .
Material and labour for DLP PVC trunking system with cover, angles, bends and all accessories and fitting of size 32x12.5mm on wall Complete all as specified and directed .
Material and labour for sheet metal enclosure for TPN DBs vertical 08 way with 01 Nos MCCB 63 Amps, 25 KA as incommer and 08 Nos SPN 32 Amps as outgoing when MCB to be used TPN 08 way, double door, IP-08, IK-09, 240V having Din rail, Neutral & Earthing bar complete all as specified and directed.
Taking down unserviceable light fitting fitting and Supply and fixing Recess mounting LED 2x2 feet slim luminare, white, 34/36 watt including all necessary fixing arrangement complete all as specified and as directed.
Supply and fixing Single pole and earth enclosure with a three pin and earth metal clad plug with socket complete with one Single pole 20 Amps MCB, 10 KA, 240 Volts. complete all as specified and as directed.
Supply, laying and commissioning, testing PVC sheathed unarmoured electric cable with copper conductor, 1100 volts grade of size 4 sqmm 3 core passing through pipes, fixed on walls complete including connecting properly by means of thimbles/bottle complete all as specified and as directed.
Supply and fixing in repair 100 mm dia ERW MS pipe heavy grade including MS fittings confirming IS-3589 (1981) and applying two coats of synthetic enamel paint over a coat of red oxide primer to pipe including welding, supporting brackets , core cutting as required at site including making good to the disturbed surfaces complete all as specified and directed.
Supply and fixing in repair 80 mm dia ERW MS pipe heavy grade including MS fittings confirming IS-3589 (1981) and applying two coats of synthetic enamel paint over a coat of red oxide primer to pipe including welding, supporting brackets as required at site complete all as specified and directed.
Supply and fixing in repair butterfly valve (ISI marked) 100mm size both ends including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed.
Supply and fixing in repair Non return valve (ISI marked) 100mm size both ends flayed with high tensile stainless steel spindle, I body including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed.
Supply and fixing in repair gun metal Two way fire brigade inlet conection with adaptor of size 80 mm dia X 63 mm dia complete all as specified and directed.
Supply and fixing in repair double headed outlet hydrant valve 100mm having 65mm outlet with lock pin wheel complete all as specified and directed.
Supply and fixing in repair single headed outlet hydrant valve 100mm having 65mm outlet with lock pin wheel complete all as specified and directed.
Supply and fixing in repair hose Reel drum with mounting base plate company made suitable for 30 mtrs X 20 mm dia rubber hose pipe complete all as specified and directed.
Supply and fixing in repair rubber hose pipe red in colour 30 mtr,20mm dia plain 2 ply rayon confirming IS-12585 braided high pressure complete including making connection and provision of brass nozzle with knob fixing with clamps at the end of the rubber hose pipe all as specified and directed.
Supply and fixing in repairs Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle complete all as specified and directed.
Material and labour in repair factory fabricated Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard fixed on wall suitable for keeping two Nos canvas fire hose with necessary nuts/bolts or welding to existing MS pipe by supporting angle complete all as specified & directed.
Supply & fix in repair canvas fire hose red in colour 63mm bore 15 m long confirming to IS 636-1988 having male/female brass coupling both end complete all as specified and directed.
Construction of brick masonary valve chamber in repair of size 1.2 x 1.2 x 1.2 M (internal dimension) (above GL 0.30 mtr) suitable for fixing of sluice valves, 15 cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hardcore of broken stone, 23cm thick brick walls built in cement and sand mortar 1:4, 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3, 15mm thick, finished even and smooth, without using extra cement, 8 mm thick plate cover on 50mm x 50mm x 6mm MS angle frame embeded in PCC 1:2:4 type B-1coping, having rectangular, hinged, opening of size 150 x 100mm with locking arrangements ,hold fasts, etc, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of debris outside MD land complete all as specified.
Supply and fixing in repair Cast Iron Air Valves (ISI marked) with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia. complete all as specified.
Supply and fixing in repairs gun metal gate valve (ISI marked) 25 mm with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified and directed.
Supply and installation in repair of water flow switch suitable for fire fighting system, pipe size 100 mm dia , operating pressure, withstand pressure as per manufacturer recommendations, including cutting, clamping, welding , control wiring , connecting and testing with all all accessories/items required at site and testing complete all as specified and directed.
Supply and installation in repairs Pressure gauge oil filled type with knob for testing 4" dial 0-14 kgs rating complete all as specified and directed
Supply and installation in repairs Pressure switch universal type including testing complete all as specified and directed.
Supply, install testing and commissioning of Booster pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988, Size (mm) Suction x delivery : 80 x65 mm With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 35mtr head, 900 LPM discharge including PCC foundation not less than 20 CM height, pump fixed on angle iron base frame from the manufacturer size and model with vibration pads, PVC insulated and sheathed three core cable of suitable size from starter to pump and Fibre sheet 2 mm thickness for shed not less than 4 sqm with angle iron as required at site for protection of pump from rain and water complete all as specified and directed. Note :- The item rate also includes PCC foundation, Fibre sheet, angle iron frames, Pump base frame, vibration pads, grouting of nut bolts and three core cable from starter to pump as required at site including testing.
Supply and fixing MCCBs 40 Amp 3 pole 415 volts, 16KA, 50 HZ including factory made SS enclosure fixed on wall and making connections complete all as specified and directed
Supply and fixing MCB double pole 16 Amps, 10 KA, 'C' series with factory made SS enclosure fixed on wall and making connections complete all as specified and directed.
Supply and fixing in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sqmm 4 core fixed on wall with steel saddles as approved by Engineer-in-Charge.
Supply and fix in repair Fire Alarm sounders / Sirens electronic type horizontal two stage continuous normal operation for at least 50 minutes with sound level 65 db to 120 db Measured at 1.5 m with sound output variation of + 5 db 1500m range complete all as specified and directed.
Material and labour for earthing complete with galvanized earth plate 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below normal ground level connecting with 25 x 4 mm GI strip by means of bolts nuts, check nuts and washers of galvanized iron all shown in electrical plate No 03 of SSR Part-I including necessary excavation earth work using PCC 1:2:4 for earthing pit and pit cover with handle of 8mm dia MS rod and connected to test point all as specified and directed. Note : (a) The item rate inclusive of fixing of earth continuity conductor from earth plate upto 7.5 mtr. (b) The item rate inclusive of provisioning necessary charcoal and salt upto the level of the earth plate in alternate layers.
Material and labour for earthing complete with galvanized earth plate 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below normal ground level connecting with 4 mm dia GI wire by means of bolts nuts, check nuts and washers of galvanized iron all shown in electrical plate No 03 of SSR Part-I including necessary excavation earth work using PCC 1:2:4 for earthing pit and pit cover with handle of 8mm dia MS rod and connected to test point all as specified and directed. Note : (a) The item rate inclusive of fixing of earth continuity conductor from earth plate upto 7.5 mtr. (b) The item rate inclusive of provisioning necessary charcoal and salt upto the level of the earth plate in alternate layers.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on FRP insulators or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x4 mm galvanised iron or steel strip complete all as specified and directed.
Supply and replacement, installation, testing & commissioning of addressable micro processor based 2 wire fault tolerant loop, required loop net workable type 2 loop (each loop accessing maximum 99 detectors and 99 modules) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault signal with address. The panel shall have rectifier, loop cards, LCD display unit to indicate Fire/Fault signal with address. The panel shall have a built in power supply and battery charger alongwith maintenance free SMF lead acid batteries as per manufacturers design with battery charger complete as required and as per specifications duly approved by EN 54 complete including making connections all as specified and directed by Engr-in-Charge.
Supply and fix in repair Addressable manual call point resettable type complete all as specified and directed
Supply and fixing in repair red colour PVC insulated PVC sheathed armoured copper conductor cable of size 2Core x 1.5 Sqmm including fixing on walls with saddles not more than 60 cm intervals complete all as specified and directed.
Supply and fixing in repair Addressable sounder range 900 dbl with strobe complete all as specified and directed
Supply and fixing in repair detectors Complying with and type certified to EN - 45 Addressable type optical multi Sensor detector heat and smoke combination Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specified and directed by the Engr-in-charge
Excavation in trenches not exceeding 1.5 mtr wide not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed by the Engr-in-charge
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil complete all as specified and directed by the Engr-in-charge
Removing excavated material exc 150 M but n.exc 500 M and depositing where directed complete all as specified and directed by the Engr-in-charge
Material and labour cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as, foundation and on road cutting hardstanding finishing even and smooth without using extra cement complete all as specified and directed by the Engr-in-charge
Cutting/demolition of cement concrete(un reinforced) /bitumen road n.exc 15 cm thickness (below or above ground level) and remove debris out side MD land complete all as specified and directed by the Engr-in-charge
Supply and laying in replacement of spigot and socket ductile iron water tubing 150 mm bore,class K-9, cement mortar lining on inner surface and one coat of bituminous paint over exposed surface ISI marked, IS No. 8329: 2000, including rubber joint of suitable size laid on roof/floor/trenches with proper alignment as per site requirement and carryout testing against leakage before filling the trenches etc complete all as specified and directed by the Engr-in-charge
Supply/Fixing in repair/replacement of steel water tubing, galvanised, Medium grade of size 80 mm with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary & capacity up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.Note (1)Work to be carried out in high rise buildings plain wall or in shafts or in terraces or inside the flats for cutting the existing GI pipe line and replace the same with new GI pipe in short piece or full length complete all as specified and directed by the Engr-in-charge
Supply and fixing in repair Gun-metal, globe or gate valves (ISI marked) 80 mm, with iron wheel head, screwed both ends for iron pipe and fixed complete with all fittings all as specified and directed
Material and labour for CI/DI specials conforming to IS - 1538 & 9523 , spigot /socket or flanged fitting I.e. bend, tee, collar, flanged/ socket /spigot, Tappers and tails pieces etc suitable for 80/100/150/200/250/300 mm bore pipes (joints and joining material shall be measured and paid seperately)
Construction of brick masonery valve chamber in repair of size 1.2 x 1.2 x 1.2 M (internal dimension) (above GL 0.30 mtr) suitable for fixing of sluice valves, 15cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hardcore of broken stone, 23cm thick brick walls built in cement and sand mortar 1:4, 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3, 15mm thick, finished even and smooth, without using extra cement, 10 mm thick plate cover on 50mm x 50mm x 6mm MS angle frame embeded in PCC 1:2:4 type B-1coping, having rectangular, hinged, opening of size 150 x 100mm with locking arrangements ,hold fasts, etc, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of debris outside MD land complete all as specified.
Supply and fixing SMC panel tank of capacity 12000 ltrs of suitable size, ISI marked in each panel , made up of top and bottom of hot pressed moulded UV stabilized panels and internal roof support of plastic with corner glass, manhole, sealant and nut and bolt of hot dip galvanised with external reinforcement of steel with anticorrosive paint and connection for inlet/ outlet and overflow of GI flanged type with air vent and water level indicator without glass of FRP including interconnection with GI pipes as per size directed and PCC platform minimum 60 cm height as per required design/ height and providing necessary c-channel base of size 100 x 50mm and glavanised ladder from roof to top of the tank suitable for placing of SMC panel tank complete all as specified and directed by the Engr-in-charge Note :- SMC tank panels should have ISI marked and original make embossing in each panel. Any other left out items required for fixing is deemed to be included in the item rate.
Taking down old unserviceable PVC tank of capacity 5000 ltrs complete all as specified and directed by the Engr-in-charge
Taking down old unserviceable PVC tank of capacity 500 ltrs complete all as specified and directed by the Engr-in-charge
Taking out old broken air termination, single pointed aluminium rod of any dia fixed over the GI Tube with the clamps complete all as specified and directed by the Engr-in-charge
Material & labour for CPT Cirprotec CPT-L ESE lightning rod with stainless steel body type advance lightning protection system in compliance with standard NFC 17-102 & UNE 21186-96, working on the principle of early streamer emission technology which will offer level 1 protection for up to 42 mtrs radius when mounted on the RCC concrete base on building at a height of structure 4.5 mtrs from the place to be protected complete all as directed by Engineer-in-Charge.
Taking out old, GI tube of any dia complete all as directed by Engineer-in-Charge.
Supply and erection of mounting structure made out of 50mm bore medium grade GI pipe and of 4.5 mtrs height with base plate suitabe for roof mounting on RCC concrete base on building including taking out old, U/S one complete all as directed by Engineer-in-Charge.
Taking out old, broken Aluminium strip of size 25 x 3mm fixed on walls/roof top with saddles and screws complete all as directed by Engineer-in-Charge.
Supply & fixing single core PVC insulated and PVC Innersheathed cable with aluminium conductor cable size 1x70 Sqmm 1100 Volt grade stranded aluminium conductor complete all as specified and as directed.
Material and labour for Galvanised steel tubes 25mm bore, light grade for protection of single core PVC insulated 70 sqmm unarmoured aluminium cable fixed on external wall surfaces of G+5 bldgs by proper clamping from roof to bottom complete all as directed.
Material and labour for PVC conduit pipe 25mm bore, medium mechenical stress for protection of single core PVC insulated 70 sqmm unarmoured aluminium cable fixed on external wall surfaces of G+5 bldgs by proper clamping from roof to bottom complete all as directed.
Supply and fixing 4 digital electromechanical lightning even counter in weather proof resistance complete all as directed by Engineer-in-Charge.
Taking out old, broken/unsrviceable earth testing point of any type complete all as directed by Engineer-in-Charge.
Supply and fixing test link box for each downconductor in order to disconnect the earth termination system to enable measurement of resistance complete all as directed by Engineer-in-Charge.
Taking out old, unserviceable earthing complete with earting material complete all as directed by Engineer-in-Charge.
Material and labour for maintainance free environment friendly earth electrode set comprising of 17.2mm dia, 3 mtrs long rod of low carbon steel molecular copper bounded for a thickness of 250 micro OHMS, highly conductive ANSI/NSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 lbs) complete all as directed by Engineer-in-Charge.
M/s. MAYUR ENTERPRISES
ORIENT ELECTRIC CO
S S ENTERPRISES
satyanarayan conastruction
RS Enterprises
SHREE JAGDISH FURNITURE CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .