| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹45.5 L+₹46,962.54 (1.04%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹48.2 L+₹3.3 L (7.23%)Rejected-Finance 254 MG ROAD LAMBA LANE JUNGLIGHAT PORT BLAIR SOUTH ANDAMAN ANDAMAN AND NICOBAR ISLANDS 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹59.8 L+₹14.8 L (32.9%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | Rejected-Technical 27 RAJABHADUR BUILDING TAMARIND LANE FORT MUMBAI MUMBAI MAHARASHTRA 400001 | MUMBAI | MAHARASHTRA | 400001 | - | Rejected-Technical Not submitted documnets as per NIT |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
14 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Minniebay
GE Minniebay Junglighat Post Minniebay Port Blair 744103
PROVN OF WEIGH BRIDGE AT DOLLYGUNJ UNDER GE MINNIE BAY PORT BLAIR
2023_MES_591069_2
8235/E8
Open Tender
Civil Works
Item Rate
180 days
Minniebay Port Blair
As per tender documents
11 documents required · 11 mandatory
₹500
GE Minniebay
₹84,000
Yes
30 Jun 2023
17 May 2023
16 Jun 2023
18 May 2023
14 Jun 2023
1 Jun 2023
Amount
Surfaces excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5m depth for foundation, etc., and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed by Engineer-in-Charge.
Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (Design mix) M-30 graded aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns & Retaining wall etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (Design mix) M-30 graded aggregate in Columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (Design mix) M-30 graded aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (Design mix) M-30 graded aggregate in slabs supported on walls, beams and columns in floors, roof landings, balconies, shelves,chajjas and the like complete all as specified and directed by Engineer-in-Charge.
M&L TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed by Engineer-in-Charge.
M&L TMT bars 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed by Engineer-in-Charge.
Form work to sides of concrete foundations, footings, bases of columns, rafts and raft beams, side and soffits (if any) of foundation and plinth beams and simillar work, vertical or to batter rough finished surfaces of concrete flat complete all as specified and directed by Engineer-in-Charge.
Form work to sides of walls, retaining wall, etc and simillar work, vertical or to batter rough finished surfaces of concrete flat complete all as specified and directed by Engineer-in-Charge.
Formwork to sides of pillars, posts, struts,piers,columns and stanchions rough finished surfaces of concrete Square, rectangular or polygonal complete all as specified and directed by Engineer-in-Charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc rough finished surfaces of concrete flat complete all as specified and directed by Engineer-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Precast cement concrete block masonry with solid blocks,Type C1,1:3:6 (20mm graded aggregate) exc 10 cm in width and setting in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded granite stone aggregate) in sub base of flooring/ hard standing.even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick plain Cement Concrete Type C2,1:3:6 (using 40 mm graded stone aggregate) in plinth protection complete all as specified and directed by Engineer-in-Charge.
M&L for Non Skid ceramic tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm screed in cement mortor 1:6 complete all as specified and as directed by Engineer in Charge.
M&L for glazed ceramic,coloured tiles in vertical surface 350x250x7 mm/ 450x 350x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in CM 1:4 on wall surface complete all as specified and as directed by Engineer in Charge
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 5mm thick in cement mortar 1:4 over a backing coat of 10mm thick in CM 1:6 on concrete or brick masonry surfaces including mixing water proofing compound as per manufacurers instructions on and including finishing the top surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. Note: Water proofing compound will be measured and paid separately
M&L for rendering 5 mm thick on concrete surfaces ( roof ceiling and soffit of chajjas), in CM (1:3) finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Supply only Integral water proofing compound.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whiting on plastered surfaces, preparatory to distempering complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of ceiling and applying two coats of cement based paint over a coat of chalk whiting on plastered surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of chalk whiting on plastered surfaces complete all as specified and directed by Engineer-in-Charge.
S&F for Aluminium anodised frames for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer-in-Charge.
S&F for Aluminium anodised door shutters, aluminium section weighing not less than 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, aluminium extruded handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc complete all as specified and directed by Engineer-in-Charge.
S&F for Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable aluminium handle (1 no.) complete all as specified and directed by Engineer-in-Charge. Note: Sheet glass, wire cloth and particle board shall be measured and paid separately under relevant items as "Supply only".
S&F for Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed by Engineer-in-Charge.
Supply only 5.5mm thick sheet glass ordinary quality, in squares n. exc 0.5sqm each pane complete all as specified and directed by Engineer-in-Charge.
Supply only 12mm thick Prelaminated particle board, interior grade, prelaminated both sides with decorative laminations, fixed with screws to aluminium frame work complete all as specified and directed by Engineer-in-Charge.
Excavation over areas n.exc. 1.5 m deep and getting out in hard / dense soil complete all as specified and directed by Engineer-in-Charge.
Excavation over areas exc. 1.5 m n. exc 3.0 m deep and getting out in hard / dense soil complete all as specified and directed by Engineer-in-Charge.
Material and labour for APP modified waterproofing treatment over existing RCC roof slab with following specification including brushing off the surface to receive the treatment obtain the required surface and then providing 10mm screed bed with water proofing compound with required slope complete as directed :- (a) Applying bituminous primer @ 1.2 kg/Sqm on the prepared dry roof surface. (b) Laying 4mm thick APP membrane Plain finish weight not less than 3 to 4 kg per sqm by torch application with minimum 10cm side lap and 15cm end lap.(c) Applying bituminous primer @ 1.2 kg/Sqm and applying one coat of bituminous aluminium paint at the rate of 0.3kg/sqm Note : The laying of membrane shall be got done through an authorized applicator of manufacturer of APP membrane.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out as in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
M&L for hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge. Note : Sample of hardcore to be incorporated in this work shall be got duly approved by GE before incorporating in work and copy of the same shall be attached along with RAR for tech check. Necessary sample shall also needs to be kept/handed over to sample room against subject CA.
M&L for 150mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing finishing even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for 80mm thick Machine pressed precast conctrete interlocking paver block reflective type any shape and size confirming to IS 15658-2006, M-40 Grade as approved laid in sand cushioning complete all as specified and as directed Note : Sand cushioning shall be measured and paid separatly
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed
M & L for supply, installation, testing and commissioning 16m x 3m ELECTRONIC WEIGH BRIDGE( Steel Truck Scale) pit type connect upto 08 Nos of load cell , extra strength (ES-series) of capcity 60 Metric ton,Static, fully electronic, Pit type Fully floating with special longitudinal / lateral bumper assembly,Fully welded, No constrainers type of Weighbridge.IS 2062 grade,Max speed of vehicle pass over 10 KMPH,Platform size of 16 M X 3 M, Maximum Capacity 60 MT,No. of Load Cells 08 nos.Verification Interval "e" Value or Minimum Graduation 05 KG,Overall weighing accuracy "2e" for full scale output,Power Supply ±220/240 V AC,Weighing Capacity Load 60 MT,Pit Type,Platform Structure Fully floating with special longitudinal / lateral bumper assembly,No constrainers,Modelling & testing with advanced design software (Pro-E) and Finite Element Analysis (FEA),Specially developed "Modular Design" for dynamic loading & rugged applications. Fully flexible for future expansion in length and/or capacity,Robotic Welding Fully welded modular design with minimum human intervention to minimize errors and to achieve homogeneous welds.Only single section rolled beams without splice joints or butt welds,Indicator Terminal.Construction with High Tensile steel,Mounting to wall, desk or column power UPS with 8 hrs backup, 85 to 264 VAC at 50 to 60 Hz operating environment 10% to 95% RH, non-condensing protection - IP68/IP 69k with inbuilt surge protection display 40 mm height, weight display, seven digits seven segments LCD with white backlight scale Interface One analog scale,Keypad Seven function keys; Zero, Tare, Clear, On/Off, Print, F1 & F2 (customizable) communication Standard: COM1 RS232, Approvals - GB/T7551 - 1997 certificate (eqv OIML R60) and accuracy - Class II & III,Span deflection ratio - 1:1300 including cable wire of 20m, suitable computer with required software installation along with printer complete all as specified and directed by Enginer-in-Charge.
Particulars/ Requirement of Electronic Weigh Bridge: (a) Alloy Tool Steel Load cell with mounting Assembly- 8.00 Nos (b) Weight controller / Terminal with weather proof enclosure- 1.00 Nos (c) Junction box IP 65 with surge protection- 1.00 Nos (d) Complete weight bridge metallic platform assembly- 1.00 Nos (e) Longitudinal bumping arrangement assembly- 1 Nos (f) Weight bridge data integration software- 1 Nos (g) Supervision of site / installation, calibration / Testing and commissioning of weight bridge with 2 years on all electronics and 5 years on platform warranty - 1 Nos (h) 4 Nos of Hydraulic jack and other welding equipments required for installation shall be provided by Contractor and Machine/installation shall be erected/installed by the contractor under the supervision of OEM/ OEm authorised Rep and shall be ensured for smooth functioning and run of installation. Note : Contractor shall need to submit Drawing, Manufacturer test certificate and brochures confirming relevant IS codal provisions to the GE for necessary approval and after the receipt of approval only, Contractor needs to place the order for incorporation in the work. Gurantee bond / Security deposit against the subject item shall be submitted by Contractor in Rs 100/- Non judicial stamp paper along with FDR for 5 years as per Gurantee conditon mentioned in Particular specification. If any defects or repair / replacement required during testing/commissioning of the installation shall be made at free of cost to the department by the Contractor with necessary liaison with OEM.
Supply and fixing LED security lights fitting 90 Watt,new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source complete all as specified as directed by Engineer-in-Charge. Make : CROMPTON Cat part No:- LSTP-90-CDL or equivalent in list of makes attached in tender copy.
S&F of GI tubular swaged poles complete with GI base plate finial taper plug, bolts, nuts and screws, with two holes for drawing conductor between pole box to street light fitting all as specified type 410 SP-31 of height 9m including necessary Earth work,PCC foundation copping etc and fixing and including PVC junction box as suitable size as approved by GE complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing building security LED light fitting of 35 Watts 240 Volts luminous shall be more than 2000 lumen and efficiency not less than 100 lm/Watt,including all fixing accessories completely mounted on 25 mm dia light grade GI pipe bracket of 1.5m long bent to shape, mounted on wall,connection complete all as specified and as directed by Engineer-in-Charge.
S & F Street light GI bracket 40mm dia medium grade ISI marked 1.5m length coated with anti corrosive primer with clamps of size 25x5mm thick (03 Set) with nuts,bolts & washers etc complete all as specified and directed by Engineer-in-Charge.
S&F GI pipe light grade 50 mm dia ISI marked along with fixing accessories for cable protection on road crossings /plinth protection or fixed to the pole/ wall etc for cable protection complete all as specified and directed by Engineer-in-Charge.
Supply, laying and jointing in trenches / passing through pipes/ fixing on poles/fixing on wall with saddles of LT under ground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area mentioned below including cable connecting lugs, glands, jointing fixing materials complete all as specified and directed by Engineer-in-Charge.
4 core 10 Sqmm.
3.5 core 50 Sqmm.
Supply & laying Telerex DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and directed by Engineer-in-Charge.
All as per item No 53.00 above but outer dia of 77 mm and inner dia 63 mm complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, not exceeding 1.50m wide and not exeeding 1.50m in depth for foundations, trenches of cable or pipe lines etc or and getting out in soft / loose soil complete all as specified and directed by Engineer-in-Charge.
Design, Supply, installing testing and commissioning factory fabricated out door type totally enclosed LT panel board suitable size with 400 Amps bus bar, conforming to relevant IS and protection class IP-65 ,dust,vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 40x40x5mm MS angle iron frame,duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of redoxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables,locking arrangement,including accomodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engr-in-charge.including Supply and fixing the following :-
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mir deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32x6 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I.Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test point.(iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit. (iv) All accessories required for galvanised steel plate electrode required, as specified and as directed.
M&L for Plain cement concrete Type B1 1:2:4 Nominal mix (using 20mm graded stone aggregate ) as in hard standing after laying cable under road etc complete all as specified and directed by Engineer-in-Charge.
M & L point wiring with 1.5 Sq.mm (nominal area) PVC unsheathed multi strandard copper conductor PVC insulated 1100 volt FRLSH grade single core cable drawn through concealed/surface and including rigid PVC conduit medium grade ISI marked minimum 25mm size and its accessories complete along with 1.5 Sqmm cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed ,ceiling/roofs with and including 1.2 mm thick MS sheet terminal boxes duly fabricated flush mounting in the wall for mounting switches,switch socket combinations fan regulators etc, as required with 3 mm thick plastic laminated sheet top cover complete all as specified and directed by Engineer-in-Charge.
One light /fan point controlled by one switch
One three pin switch socket 5/6 Amps plug point on same board
One five pin switch socket 5/6 Amps plug point on Independent board
All as per item No.60.00 here-in-before but with 2.5 Sqmm single core multi standard unsheathed FRLSH copper conductor for one three pin socket 16 Amps on independent board including continuous earth wire PVC insulated 1.5 Sqmm FRLSH copper solid conductor to common earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No.60.00 here-in-before but with 4 Sqmm single core multi standard FRLSH copper conductor for one three pin socket 15 Amps on independent board/metal clad socket for AC point including continuous earth wire PVC insulated 4 Sqmm FRLSH copper solid conductor to common earth dolly complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of switch piano, flush button type, single pole, one way 16 amps complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of switch piano, flush button type, single pole, one way 6 amps complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of socket outlet 2-in-1, 3 pin, 6 amps flush type complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of ceiling rose, surface bakelite 65 mm x 30 mm, 3 terminals complete all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring complete with 2 x 2.5 sqmm, single core, multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 volts grade, drawn in 25mm PVC conduit on surface (as required) along walls roofs etc including 2.5 sqmmm size PVC insulated unsheathed copper conductor to common earth continuity and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge. Note (i) All three wire/cable (phase, neutral and earth) should be run through for each individual circuit from the DBs. (ii) Two run/four runs of cable and one run/two runs of earth conductor and PVC Conduit/Casing Caping be measured as one length.
All as per item No. 69 above but 2 x 4 sqmm and 1 x 4 sqmm for earth wire complete all as specified and directed by Engineer-in-Charge.
S&F in replacement DB SPN 8 way with category of protection double door type IP-42 factory made with tinned copper 200 Amps rated bus bar suitable for MCBs,all as specified and directed. Note : SPN distribution board shall be fixed in the wall such that front cover shall be seen flush with the wall surface complete all as specified and directed by Engineer-in-Charge.
Supply and fixing amp rating 240V, 10KA breaking capacity 'C' curve miniature circuit breaker (MCB) SP 6 to 32 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 240V, breaking capacity 10 KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity of 32 AMP, in the SPN DB Complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge.
S & F single pole and neutral enclosure with a two pin and earthplug and socket complete with one single pole MCB complete all as specified and directed by Engineer-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210cfm with service value of 6.00 BEE. Five star rated with brushless direct current motor complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge.
S & F LED bulb 12 W suitable for holder complete all as specified and directed by Engineer-in-Charge.
Supply and fixing unarmoured electric power cable (Heavy duty) with stranded copper conductor for 1100 volts grade of 3 core 1.5 sqmm cross sectional area for street lights in PVC conduits complete all as specified and directed by Engineer-in-Charge.
S & F lamp holder ( angular type) insulated body with back plate complete all as specified and as directed by Engineer-in-Charge.
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip 25×4mm connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I complete all as specified and as directed by Engr-in-Charge. Note: (i) Cost of earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning & filling, PCC chamber pit, RCC cover & test point.(iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit.(iv) If the desired earth resistance is not achieved during testing as per IS , the complete earthing shall be replaced / repaired by the contractor at his own cost and no extra claim shall be admissible. (vi) Earth test report shall be submitted to Accepting Officer for the payment of RAR / FB
OPS Associates
Kakolil Trade Agencies
MGP Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .