Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.9 CrAccepted-AOC | ₹1.9 Cr Quoted ₹3.4 Cr | L-1 | Accepted-AOC VALID |
| 2 | Rejected-Technical | - | - | Rejected-Technical INVALID |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
19 Dec 2019, 2:00 pmClosed
Ravinder Kumar, Executive Engineer
EXECUTIVE ENGINEER, PUBLIC HEALTH ENGINEERING DIVISION, BAWAL
Providing canal based water works scheme for Garhi, Bolni, Bagthala Kheri Motla group of villages construction of water works at village Kheri Motla Distt. Rewari (Under Sansad Adrash Gram Yojna ON RISK AND COST OF SH. MANJEET SINGH CONTRACTOR
2019_HRY_110423_1
PHED/BAWAL/ 17895-958
Open Limited
Civil Works - Others
Works
270 days
garhi bolni
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
EXECUTIVE ENGINEER PHED
₹3.4 L
Yes
27 May 2020
28 Nov 2019
19 Dec 2019
28 Nov 2019
19 Dec 2019
28 Nov 2019
Amount
Pumping Machiner A) RAW WATER PUMPING STATION Raw water pump set Erection testing & commissioning of Open well Submersible pumping sets as per IS specification no 14220 - 1994 (as amended from time to time up to date for pumps ) and 9283-1994 (as amended up to date for motors ) as per the following details. 1800 LPM at 40 M. Heads (70% Paid, Balance 30% for installation and commissioning)
B) WATER WORKS KHERI MOTLA i) Raw water pump set Erection testing & commissioning of Open well Submersible pumping sets as per IS specification no 14220 - 1994 (as amended from time to time up to date for pumps ) and 9283-1994 (as amended up to date for motors ) as per the following details. 900 LPM at 15 M. Heads (at w/w) (70% Paid, Balance 30% for installation and commissioning)
ii) Clear water pump set Erection testing & commissioning of Open well Submersible pumping sets as per IS specification no 14220 - 1994 (as amended time to time up to date for pumps ) and 9283-1994 (as amended up to date for motors ) as per following details 650 LPM at 35 M. Heads Motor (For B/Stn. Bolni) (70% Paid, Balance 30% for installation and commissioning)
400 LPM at 50 M. Heads Motor (For B/Stn. Bagthala) (70% Paid, Balance 30% for installation and commissioning)
400 LPM at 40 M. Heads Motor (For B/Stn. Kheri Motla) (70% Paid, Balance 30% for installation and commissioning)
C) B/STN BOLNI i) Clear water pump set Supply , erection testing & commissioning of Open well Submersible pumping sets as per IS specification no 14220 - 1994 (as amended from time to time up to date for pumps ) and 9283-1994 (as amended up to date for motors ) as per the following details. 800 LPM at 40 M. Heads Motor (70% Paid, Balance 30% for installation and commissioning)
700 LPM at 40 M. Heads Motor (70% Paid, Balance 30% for installation and commissioning)
D) B/STN BAGTHALA i) Clear water pump set Erection testing & commissioning of Open well Submersible pumping sets as per IS specification no 14220 - 1994 (as amended from time to time up to date for pumps ) and 9283-1994 (as amended up to date for motors ) as per the following details. 800 LPM at 40 M. Heads Motor
Panel Board for Motors Supply, erection, testing & commissioning of wall mounted electrical L.T. Panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm and 400 mm deep having the follwing items a) Main switch 100 Amp. 1 No. (L&T Siemens, ABB) b) Volt meter 100x100 mm range 0 to 500 Volt 1 No. (AE/KAPPA/L&T) c) Amp meter 100x100 mm range 0 to 100 Amp. 1 Nos. (AE/KAPPA/L&T) d) CT 100/3 Nos. (AE/KAPPA/L&T) e) VSS & ASS 1 No. each of approved make f) SPP 1 No. of approved make g) Motor starter, star delta 1 No (L&T Siemens, ABB) h) Capacitor KVAR as per site requirement i) Indicating Lamp - One Set & 1 change over switch 100 AMP For 1800 LPM at 40 M. Heads, Pump Sets
For 900 LPM at 15 M. Heads, Pump Sets
For 650 LPM at 35 M. Heads, Pump Sets
For 400 LPM at 50 M. Heads, Pump Sets
For 400 LPM at 40 M. Heads, Pump Sets
For 800 LPM at 40 M. Heads, Pump Sets
For 700 LPM at 40 M. Heads, Pump Sets
Sluice Valves & specials for Pumping Machinery Supplying, fixing, jointing, testing & commissioning of DI sluice valves resilient sheet P.N. 1.6 as per DNIT specification on the pumping machinery & Heads works including cost of jointing material (IVC / VAG make) 100 mm i/d
Supply and fixing of DI D/Fbends , reducers , Tees , pipe and specials etc. including cost of Jointing materials, laying, jointing, in position as per specifications.
DI D/F Pipes. 100 mm i/d
Diesel Generating Set Designing, Supply & erection of DG set of required capacity given below with acoustic of suitable rating with change over switch, fenced enclosure with platform for DG sets complete as per DNIT. The rating should be at 1500 RPM (a) Diesel Engine b) Alternator c) Bettery 24 V (d) Base Plate (e) 1x120 sq mm 3.0 core XLPE Aluminum = 20 m (f) Tools A.M.F. PANEL (a) Motorised change over switch 250 Amp 4 P with fuse base and HRC links 250 Amp. (b) Under voltage/ over voltage relay - 2 No. 415 VAC (c) Engine Start relay 24 VDC 1 No. (d) Electronic Timers 24 VDC 1 No. (e) Electronic Timers 24 VDC 2 No. (f) Auxiliary relay 220 VAC - 2 No. (g) Auxiliary relay 220 VAC - 3 No. (h) Metering set 415 VAC - 1 set (Amp. Meter, Volt Meter, ASS, VSS, Phase Indicaters, Control fuse, frequency meter, CT'S) (i) Metering set 24 V DC (Amp. Meter, Volt Meter) (j) Over Load protection for DC - 1 No. (k) Battery Charger 24 V DC (Blueron make) (l) Copper bus bar of suitable size (m) KWH meter 96 square mm size (n) Starting fuse button and key switch (On/Off) (o) Engine Protection unit with Audiovisual alarm and shut down for low lubricating oil pressure and high coolant temperature. (p) Indicating lump for low lubricating oil pressure high collant tempurature, set running, load on, DC control on. Note: Control Panel shall have the provision to provide auto manual failure panel (AMFP). 50 KVA for Raw Water Pumping Station (70% Paid, Balance 30% for installation and commissioning)
Supply erection testing and commissioning of exhaust fans each having a capacity of 45 cubic metre per minute, complete with suitable G.I sheet Ducting in meter room and pump Chamber and energy for the sites.
Supply erection & testing of Ceiling fan of size 48" i/d (1200 mm) of reputed IS I make complete in all respects.
Supply erection, testing of light fitting including wire in the pump chamber with material upto 10 points including switch, button, plug, PVC conduict pipe & copper wire etc. as per approved specifications.
Providing and fixing of insulated Rubber matting suitable for HKV installation 1 meter x 2 meter x 12mm as per panel SPEC for sites as per specification.
S&S Tank Providing & fixing suitable floating arm 250 mm size along with swivel bend as per required specifications approved by Engineer-in-Charge
Supplying, erection, testing and commissioning of sluice gate valves 250mm x 250mm with actuators for S&S tanks with all accessories including cost of joining material complete in all respects.(i) Sluice gate (IVC / Kirloskar make)
Providing and fixing of PVC water Bar (fixo- stop) with ribs & central bulbs of size given below confirming to IS-12200 of 1987 (fixo-stop) along with the bitumen board including cost of bitumen filler complete in all respect i) 250 mm wide x 8 to 11 mm thickness.
Sluice Valves & specials for Distribution lines/ rising main Supplying fixing, testing, jointing & commissioning of DI sluice valve resilient sheet PN:1.6 as per DNIT specification including cost of jointing material of make IVC & VAG 100 mm
Supply and fixing of DI D/Fbends , reducers , Tees, pipe and specials etc. including cost of Jointing materials, laying, jointing, in position as per specifications
Providing & fixing of D.I. Air Valve “IVC” Brand soft seated complete as confirming to I.S.I. for 100mm i/d D.I. S.V. complete. 80 mm
Providing & fixing of C.I. U type bend 200mm i/d for clear water tank complete in all respects. 200 mm
Providing & fixing of Flow meter crone make complete in all respect .
Operation and maintenance of water works (disinfection material suppliedby the PHED) as per schedule-IV for a period of 5 years (60 Months) after three months trial run period (will be charged to A/Mtc. Estimate)Operation and Maintenance during the defect liability period (Operation only)
1st Year operation & Maintenance after defect liability period
2nd year operation and maintenance
3rd year operation and maintenance
4th year operation and maintenance
Bidder Name
Amount
Vinod Manocha Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .