Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAccepted-AOC 252 22 NEAR SOCITY BUS STAND INDRA COLONY PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹37.6 L+₹1.8 L (4.98%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹39.9 L+₹4.1 L (11.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹40.9 L+₹5.0 L (14.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹43.2 L+₹7.4 L (20.6%)Rejected-Finance BRAJANATHCHAK TOWNSHIP HALDIA HALDIA HALDIA | MEDINIPUR EAST | WEST BENGAL | 721605 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹36.4 L
EMD Value
₹72,800
Closing Date
13 Feb 2025, 6:00 pmClosed
GE 860 EWS Karu
GE 860 EWS Karu Pin-194201
REPAIR/REPLACEMENT OF SWITCHGEAR, CHANGEOVER SWITCH, BUS BAR, RELAYS, LBS WITH CONNECTED ACCESSORIES AT KARU ZONE I II AND SHESHARTHANG UNDER GE 860 EWS
2025_MES_694765_1
8191/2024-25/E8
Open Tender
Civil Works
Item Rate
270 days
KARU
As per tender documents
9 documents required · 9 mandatory
₹500
GE 860 EWS Karu
₹72,800
Yes
19 Mar 2025
24 Jan 2025
15 Feb 2025
24 Jan 2025
13 Feb 2025
7 Feb 2025
Amount
S&F in replacement of LT FPB made out of CRCA sheet 3 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 1500 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:
Incoming: LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with air circuit breaker, with microprocessor release IPR -E eleteical draw type 1000 Amp, 100 KA , overload protection, no-volt release with necessary CTs,meter and cable boxes of rating upto - 01 No for incoming
Outgoing: a) ACB AC 3 Phase 415 V, 50Hz 4 pole 630A capactiy 100KA with adjustable type thermal and magnetic setting relays - 02 Nos ( one No working and stand by) b) MCCB AC 3 Phase 415 V, 50Hz 4 pole 200 A capactiy 36 kA with adjustable type thermal and magnetic setting relays - 04 Nos c) MCB SPN 40 Amps 2P - 01 for local lighting d) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs e) LED indicating lamps with colour Red, Yellow, Blue - 01 Set f) Panel drawing shall be got approved from GE before placing the order.
S&F in replacement of LT panel box, by means of nut bolts washer, and opening of existing LT cables properly stacking, and supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 450mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 800 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (400Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable dismantled before etc., and comprising of the following:-
(a) MCCB 400 amps, 4 pole with breaking capacity 36KA (Adjustable thermal & magnetic release) - 01 No(Incomer) (b) MCCB 160 amps, 4 pole with breaking capacity 25 KA (Adjustable thermal & magnetic release) - 01 No (outgoing) (c ) MCCB 100 A 4 pole with breaking capacity 25 KA (Adjustable thermal & magnetic release) - 08 Nos (outgoing) (d ) MCCB 63 A 4 pole with breaking capacity 25 KA (Adjustable thermal & magnetic release) - 08 Nos (outgoing) (e) Multifunctional meter Cat No 30332567 MAKE schneider (f) Moulded fuse holder 125 A including HRC fuses = 3 Nos (g) Indicator lamp RYB :01 Set (h) CT'S 400/5 01 Set Make-L&T (j) Panel drawing shall be got approved from GE before placing the order.
Supply & Laying in replacement cable XLPE FRLS Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 500 sqmm complete all as specified and directed by Engr-in-Charge.
Description all as per item Srl No. 3.00 here in before but 3.5 core 400 sqmm
Description all as per item Srl No. 3.00 here in before but 3.5 core 300 sqmm
Description all as per item Srl No. 3.00 here in before but3.5 core 240 sqmm
Description all as per item Srl No. 3.00 here in before but 3.5 core 95 sqmm
Description all as per item Srl No. 3.00 here in before but 3.5 core 70 sqmm
S&F in replacement of sheet metal double door enclosure MCCB TPN DBs 4 way 415V flush mounted complete all as specified and directed by Engr-in-Charge.
Supply and Laying in replacement of GI pipe light grade in trenches/Floor or fixed to Pole/Wall with all fitting for protection of cable including dismantling existing pipe of size 100 mm bore complete all as specified and directed by the Engineer-in-Charge.
Description all as per item Srl No. 10.00 here in before but 80 mm bore
Description all as per item Srl No. 10.00 here in before but 50 mm bore
S&F in replacement, LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with MCCB, 63 Amps, 16 KA, ICS = 100% ICU, with adjustable thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F in replacement, LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with MCCB,100 Amps, 35 KA, ICS = 100% ICU, with with adjustable thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F in replacement, LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with MCCB, 160 Amps, 36 KA, adjustable type , including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F in replacement, LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with MCCB, 200 Amps, 36 KA, adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F in replacement, LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with MCCB, 250 Amps, 36KA adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F in replacement, LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with MCCB, 400 Amps,36 KA adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F in replacement, LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with ACB, 630 Amps, 50 KA adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F in replacement, LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with ACB, 800 Amps, 50 KA adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 1500 Amp capacity complete with powder coating, necessary internal electric connection as required complete all as specified and directed by Engr-in-Charge.
Description all as per item Srl No. 21.00 here in before but capacity of 1000 Amp
Description all as per item Srl No. 21.00 here in before but capacity of 800 Amp
Description all as per item Srl No. 21.00 here in before but capacity of 600 Amp
Description all as per item Srl No. 21.00 here in before but capacity of 400 Amp
Description all as per item Srl No. 21.00 here in before but capacity of 200 Amp
Supply and fixing in repair on load change over switch 400 Amps capacity, 415 Volts, 50 Hz, 4 Pole with advance neutral complete open execution type complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair on load change over switch 315 Amps capacity, 415 Volts, 50 Hz, 4 Pole with advance neutral complete open execution type complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair on load change over switch 250 Amps capacity, 415 Volts, 50 Hz, 4 Pole with advance neutral complete open execution type complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair on load change over switch 200 Amps capacity, 415 Volts, 50 Hz, 4 Pole with advance neutral complete open execution type complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair on load change over switch 100 Amps capacity, 415 Volts, 50 Hz, 4 Pole with advance neutral complete open execution type complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB SP-06 to 40 Amp, 240 volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB SPN-06 to 32 Amp, 240 volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB TPN-63 Amp, 240 volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Intelligent Panel meter to measure voltage, current, frequency, power factor, etc on LT panel with all connected CTs complete all as specified and as directed by the Engineer in charge.
S&F in replacement of LED indicating lamps with colour Red, Yellow, Blue - 01 Set in LT panel with all connected CTs complete all as specified and as directed by the Engineer in charge.
S&F in replacement of Automatic 3 Phase 415 V, 50Hz, 500kW LT Distribution Control Panel (LBS) made up of MS plate with Aluminium Bus bar for Controlling and Monitoring the mains Supply from a centralized Location with Dimension of 8 x 13 x 2ft (H x W x D) Rectangular shape complete all as specified and as directed by the Engineer in charge.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of cable/foundation of pole and stay etc and getting out in hard/dense soil soil complete all as specified and as directed by the Engineer in charge.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of cable/foundation of pole and stay etc and getting out in hard rock complete all as specified and as directed by the Engineer in charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and as directed by the Engineer in charge.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point all as specified and as directed by the Engineer in charge.
Taking out Old UNSV earthing and M&L for Earthing complete with GI plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to steel earth STRIP 32X6MM up to 7.5 mtr by means of nuts, bolts, check nuts, washers of tinned brass, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering,including charcoal or coke and salt in alternate layers and filling earth pit with fresh vegetable soil below copper plate and above upto ground level as required and necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed.(Note:i)Charges for earth resistivity test deemed to be included in the quoted rate.ii)Earth resistance value shall be less than 1.0 ohm)
Sand cushioning to underground cable complete all as specified in clause 19.75 of SSR Part - I, complete all as specified and directed by Engr-in-Charge. Note- Only punned thickness shall be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm complete all as specified and directed by Engr-in-Charge.
Rampal Singh Contractor (BID ID -3237869)
osho traders (BID ID -3237891)
M/S JAVED CONSTRUCTION COMPANY (BID ID -3238171)
M/S MA CONSTRUCTION Co (BID ID -3238763)
M/S MOHD KARIM (BID ID -3238746)
M/S NISSAR ALI (BID ID -3238831)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .