Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 1 4 A GREEN BELT OPPOSITE POLICE COLONY BY PASS BEMINA SRINAGAR JAMMU KASHMIR 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
15 Mar 2021, 6:00 pmClosed
ASSISTANT REGISTRAR PROCURMENT AND STORES
IUST AWANTIPORA
Supply and Installation of Laboratory Equipments for Centre for Vocational Studies
2021_IUST_119698_1
IUST/Reg PS/CVS/2021/160
Open Tender
Laboratory and scientific equipment
Item Rate
30 days
IUST AWANTIPORA
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
ISLAMIC UNIVERSITY OF SCIENCE AND TECHNOLOGY
₹50,000
25 Mar 2021
8 Mar 2021
18 Mar 2021
8 Mar 2021
15 Mar 2021
8 Mar 2021
Pipettes ( 10-100uL, and 100- 1000 µL) Make: (Gilson, Eppendorf, Himedia, Tarsons) Volume adjustable Volumes, 10µl-100µl, 100µl-1000µL It should be highly resistant to heat, acids and alkalis, mildew, bleaches, aging, sunlight and abrasion Positioned for perfect Ergonomics Ejector: Very low ejection force and positioned for perfect ergonomics. Quick connection clip: Remove lower part easily. Should be supplied with factory calibration certificate. European CU Certified Warrant ≥1 year and from the date of installation and AMC per year after the expiry of standard warranty
Table Top high speed Non -refrigerated Centrifuge (Eppendorf, Thermo Fisher, Sorvall) Maximum Speed of 30,130xg /14000 rpm, with a brushless motor Speed setting should be possible in both rpm and rcf Rotors to be supplied with centrifuge should have minimum 30X1.5mL It should be possible to store 50 programs with 5 quick access program keys Should possess a separate short spin key for brief spin Rotor lids should have a Quick Lock-system for secure lid closing and opening Noise levels should be ˂54 db(A) It should be possible to operate the centrifuge at set rpm, for short spin protocols Instrument should be CE certified, IVD conformity
Protein Electrophoresis system (Tarsons, Biorad, Sigma, Himedia and Thermo Fisher) Gel Tank should be compatible with both homemade as well as readymade gels Gel Tank should be compatible with running as well as transfer module Gel Tank should accommodate up to four or more gels per run. Should supply power Supply Adapters to connect the covered power leads of electrophoresis units to power supplies made by other companies Should supply gel Handcast System. There should be at least 2-Handcast Stations Handcast System should include: 2-4 Sealing Pads, 2-4 Glass Plate Sets, Gel Combs (at least 2 each: 10 and 15 well) The Blotting Module should be a wet transfer device
Multi-Functional IV Training Arm Injection Should have 8 vena of the vascular system of the arm Should provide a good training of injection, infusion and phlebotomization Skin color PVC material Rating should be above 4 Star European CE certification Warrant ≥1 year and from the date of installation and AMC per year after the expiry of standard warranty
Agarose gel Electrophoresis Unit Tarsons, Biorad, Sigma, Himedia and Thermo Fisher) Gel Tank should have a volume of 400-500 ml and compatible homemade gels Gel Tank should accommodate up to two or more gels per run. Should supply power Supply Adapters to connect the covered power leads of electrophoresis units to power supplies made by other companies Should supply gel Handcast System. There should be at least 2-Handcast Stations Power supply should have constant voltage or current settings Power supply should have Built-in timer for walk-away gel electrophoresis Power supply should have 2-4 sets of output jacks that are compatible with most electrophoresis devices. Two Boats (dams) large and small Handcast System should include: Gel Combs at least 2 each: 5, 10 and 15 well. Suitable for electric supply of 220-240V European CE certification Warrant ≥1 year and from the date of installation and AMC per year after the expiry of standard warranty
Fridge (Samsung, LG and whirlpool) Capacity should be 300- 340 Liters Temperature Range of 1 ° C to 10 ° C 4-7 shelves, Adjustable Free-Standing or Horizontal Solid state digital temperature controller with alarm Standard Single or double door Stabilizer Required: No Suitable for Electric supply of about 220-240V(Low energy consumption)
Sphygmomanometer Make (Omron, Dr Morepen, Withings BPM Connect Manual Should have universal cuff Accuracy should be within 5 mmHg Easy to use
Sphygmomanometer Make (Omron, Dr Morepen, Withings BPM Connect Automatic and digital For adult Pressurization through internal motor pump Oscillometric Automatic adjustment of cuff pressure and exhaust speed Measurement in mm Hg Measurement range of heart rate from 40-180 or more Accuracy of pulse rate measurement ± 2% LCD display
BIOMED SYSTEMS
BIOMED SYSTEMS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .