| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹25.9 L+₹3.2 L (14.1%)Rejected-Finance 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹27.4 L+₹4.7 L (20.9%)Rejected-Finance 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L3 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
5 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NASIRABAD
Garrison Engineer, Military Engineer Services, Nasirabad, Pin - 305601
REPAIRS AND MAINTENANCE OF SUMMER APPLIANCES AT AJMER AND NASIRABAD MIL STN UNDER GE NASIRABAD
2024_MES_640976_1
8421/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE Nasirabad
MES Contractor enlisted as Class D and above and category b(i) having deposited Standing Security of Rs 1,00,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
Yes
GE NASIRABAD
₹54,000
Yes
13 Mar 2024
6 Feb 2024
7 Mar 2024
6 Feb 2024
5 Mar 2024
20 Feb 2024
6 Feb 2024 - 20 Feb 2024
Amount
Dismantling and taking out the existing old unserviceable compressor hermetically sealed unit of window type AC and S&F New compressor suitable for window AC of capacity 1.5 Ton complete all as specified and directed by Engineer in Charge. Make :Tecumesh/Hitachi/LG or equivalent
All as per Srl item No.1.00 here in before but compressor suitable for window AC of capacity 2.0 Ton complete all as specified and directed by Engineer in Charge. Make :Tecumesh/Hitachi/LG or equivalent
Dismantling and taking out the existing old unserviceable compressor hermetically sealed unit of any make from split type AC and S&F New compressor suitable for Split AC of capacity 1.5 Ton complete all as specified and directed by Engineer in Charge. Make :Tecumesh/Hitachi or equivalent
All as per Srl item No.3.00 here in before but compressor suitable for Split AC of capacity 2.0 Ton complete all as specified and directed by Engineer in Charge. Make :Tecumesh/Hitachi. Note :- For Sl N0 1.00 to 4.00 1. All Engineering works shall be carried out at site/E/M store yard only in presence of JE/Engr- in- Charge. 2. No equipment shall be transport/carry out to local market for repairs
M&L for testing leakage in system Window type Air conditioner of 1.5/2.0 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system complete all as specified and directed by Engineer in Charge.
M&L for testing leakage in system Split type Air conditioner of 1.5/2.0 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system complete all as specified and directed by Engineer in Charge.
M&L for servicing of Air conditioning of Window/Split of any capacity including air Filter Cleaning, Condenser and Evaporator coil Cleaning, insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water complete all as specified and directed. Note :- Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department complete all as specified and directed.
S&F only for the following items, complete all as specified and directed by Engineer in Charge.:- Make : Usha/Epcos/Havells
All as per Srl item No. 8.00 here in before but Starting capacitor of capacity 80/100 MFD.
All as per Srl item No. 8.00 here in before but Starting capacitor of capacity 100/120 MFD.
All as per Srl item No. 8.00 here in before but Running Condenser capacity of 10/20 MFD.
All as per Srl item No. 8.00 here in before but Running Condenser capacity of 36 MFD multipurpose.
All as per Srl item No. 8.00 here in before but Running Condenser capacity of 40/45/50 MFD.
All as per Srl item No. 8.00 here in before but Running Condenser capacity of 60MFD, multipurpose.
All as per Srl item No. 8.00 here in before but Cooling Coil and condensor coil suitable for 1.5/2.0 Ton Capacity Window AC(Blue star AC, LG AC) as per existing sample.
All as per Srl item No. 8.00 here in before but Cooling Coil and condensor coil suitable for 1.5/2.0 Ton Capacity Split AC (Blue star AC, LG AC) as per existing sample.
All as per Srl item No. 8.00 here in before but Swing motor suitable for 1.5/2.0 Ton Capacity Window type Air Conditioner (Blue star AC, LG AC) as per existing sample.
All as per Srl item No. 8.00 here in before but Swing motor suitable for 1.5/2.0 Ton Capacity Split type Air Conditioner (Blue star AC, LG AC) as per existing sample.
All as per Srl item No. 8.00 here in before but Over load relay suitable for 1.5/2.0 Ton Window type AC.
All as per Srl item No. 8.00 here in before but Over load relay suitable for 1.5/2.0 Ton Split type AC.
All as per Srl item No. 8.00 here in before but PVC Front gril suitable for Window type AC of any Make As per exsting sample suitable for 1.5/2.0 Ton window AC.
All as per Srl item No. 8.00 here in before but Electric blower motor double shaft suitable for 1.5/2.0 Ton Capacity Window type AC. Make: Raptor/Generic or equivalent.
All as per item No.8.00 here in before but Electric Blower Motor Double Shaft suitable for 1.5/2.0 Ton Split AC. Make :- Raptor/Generic or equivalent.
All as per Srl item No. 8.00 here in before but Blower motor fan blade suitable for 1.5/2.0 Window type AC.
All as per Srl item No. 8.00 here in before but Blower motor fan blade suitable for 1.5/2.0 Split type AC.
All as per Srl item No. 8.00 here in before but Condenser motor with fan blade suitable for 1.5/2 Ton capacity Window type AC.
All as per Srl item No. 8.00 here in before but Condenser motor with fan blade suitable for 1.5/2 Ton capacity Split type AC.
All as per Srl item No. 8.00 here in before but Thermostat switch with knob suitable for AC of any capacity.
All as per Srl item No. 8.00 here in before but Air Filter Suitable for 1.5/2.0 Ton Capacity Window/Split type Air conditioner.
All as per Srl item No. 8.00 here in before but Capillary tube length as per existing size suitable for 1.5/2.0 Ton Capacity Air conditioner.
All as per Srl item No. 8.00 here in before but PCB Circuit with remote control suitable for any make and capacity of 1.5/2.0 Ton Window type AC and 1.5/2.0 split type capacity Air Conditioner.
All as per Srl item No. 8.00 here in before but for PVC flexible waste condensing drain out pipe for split AC suitable size fixed properly on wall /floor etc. connetced properly all as directed
M&L repair & replacement of new Suction pipe suitable for 1.5/2.0 ton capacity Suitable for Air conditioner as per sample complete all as specified and directed by Engineer in Charge
M&L for replacement of damaged Insulation of size 1/4&3/8 for Split AC complete as per existing sample complete all as specified and directed by Engineer in Charge
M&L for replacement of damaged Insulation of size 1/2 & 5/8 for Split AC complete as per existing sample complete all as specified and directed by Engineer in Charge
M&L for replacement of Rubber bush suitable for 1.5/2.0/3.0 ton capacity Suitable for Air conditioner as per sample complete all as specified and directed by Engineer in Charge
M&L for replacement of Copper Tube of size 1/4 and 3/8 suitable for any type and any capacity Air conditioner complete all as specified and directed by Engineer in Charge
M&L for replacement of Plug nut of size 1/2 and 5/8 suitable for any type and any capacity Air conditioner complete all as specified and directed by Engineer in Charge
Taking out and shifting new location and refixing both indoor and outdoor unit of split type Air conditioning electrically driven 230V/250V ,AC 50 Hz capacity 1.5/2.0 Ton in wall with rowl plugs including making holes for inlet /outlet in the wall with 50mmX50mmX6mm size of agle iron for foundation of condensing unit as per suitable size and making good existing surface including insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer complete all as specified and directed.
Disconnecting of old indoor/outdoor split ac S&F of new indoor/outdoor unit of split AC complete all as specified and directed.
Dismantling and taking out the existing old unsv compressor sealed unit from Water cooler and S&F new compressor copper wound unit for operation on single phase, 230 V, 50 Hz, AC supply & confirm to IS-1067 Part-I, suitable for Water cooler of cooling capacity 40/80 ltrs/hrs and complete. Note:- 1. All Engineering works shall be carried out at site/E/M store yard only in presence of JE/Engr- in- Charge. 2. No equipment shall be transport/carry out to local market for repairs
All as per item No.17.00 here in before but compressor suitable for Water Cooler of cooling capacity 60/120 ltrs/hrs complete all as specified and directed. Make-Kirloskar/Blue star/LG/Tecumseh/Voltas/Usha
All as per item No.17.00 here in before but compressor suitable for Water Cooler of cooling capacity 150/150 ltrs/hrs complete all as specified and directed. Note:- Item Srl .No. 17 to 19 Make-Kirloskar/Blue star/LG/Tecumseh/Voltas/Usha
M&L Checking the unserviceable water cooler of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete.
S&F only for the following items, complete all as specified and directed by Engineer in charge.:- Make:- LG / Blue star / Universal / Airmaster
All as per item No.21.00 here in before but Condensor motor 1/35 HP 230V,SP, 50 Hz suitable for 40/80 capacity water cooler as per existng sample complete all as specified and directed by Engineer -in-Charge.
All as per item No.21.00 here in before but 1/10 HP suitable for 150/150,60/120 or equivalent water cooler as per existng sample complete all as specified and directed by Engineer -in-Charge.
All as per item No.21.00 here in before but Condenser Blower fan blade suitable for 150/150,60/120 and 40/80 capacity water cooler or suitable for 1/10HP & 1/35 HP fan motor only including nuts/bolts any make and any capacity as per site requirement.
All as per item No.21.00 here in before but Capacitor for condenser motor suitable for any capacity, size complete Make: Milborn / Universal / Dipcon / Runcon / Usha / Epcos / Brite or equivalent
All as per item No.21.00 here in before but Starting Capacitor suitable for compressor of water cooler 150/150,60/120 and 40/80 capacity Make: Milborn / Universal / Dipcon / Runcon / Usha / Epcos / Brite or equivalent
All as per item No.21.00 here in before but Running Capacitor suitable for compressor of water cooler 150/150,60/120 and 40/80 capacity Make: Milborn / Universal / Dipcon / Runcon / Usha / Epcos / Brite or equivalent
All as per item No.21.00 here in before but Starting relay current type suitable for compressor of water cooler 150/150,60/120 and 40/80 capacity Make: Usha / Asian / Brite / Epcos / Dipcon / Concap or equivalent
All as per item No.21.00 here in before but Over load Protector with relay box type suitable for compressor of water cooler 150/150,60/120 and 40/80 capacity. Make:- Hitachi/Anupurna/whirlpool or equivalent.
All as per item No.21.00 here in before but Thermostat switch with knob suitable for compressor of water cooler 150/150,60/120 and 40/80 capacity. Make : Godrej / Renutrol/ Anpurna/ Whirlpool or equivalent.
All as per item No.21.00 here in before but PVC float valve of size 15 mm assy alongwith ball with complete accessories for water cooler any capacity of size 15 mm dia . Make: Prayag/leader/Supreme
All as per item No.21.00 here in before but Supply and repalcement of Self closing water tap 15 mm dia chromium plated inner/outer thread as per sample for water cooler 150/150,60/120 and 40/80 capacity Make: Waterman / Leader / Prayag / Leader.
All as per item No.21.00 here in before but Air Filter Suitable for water cooler 150/150,60/120 and 40/80 capacity as per existing sample.
All as per item No.21.00 here in before but Capillary tube of suitable length as per existing size for water cooler 150/150,60/120 and 40/80 capacity as per existing sample.
Taking out old u/s copper conductor cable lead from water cooler any capacity and supply and fixing new copper conductor cable for water cooler lead size 2.5 sqmm 3 core AC, 50 Hz, PVC sheathedand overall PVC insulated all as directed.
Taking out old US plug top from water cooler any capacity and S & F of new plugtop of 15 Amp complete all as directed. Make: Anchor/Cona/Havells
Taking out old US PVC drain pipe from water cooler any capacity and S & F new PVC drain pipe with clamp of size 40 mm dia for water cooler all as directed
Taking out old U/S top cover gasket of water cooler 80/120/150 (storage capacity) and supply and fixing new gasket all as directed. Make : Usha/Blue star.
Taking out old unserviceable top cover holding clamp of water cooler of any capacity and supply and fixing new holding clamp all as directed
M&L for testing the leakage in system by charging of Nitrogen Gas up to 300 PSI. Repairing of leakage spots/Joints with gas welding work, cleaning and flushing the complete water cooler with gas, making the system leak proof, vacuuming the complete system complete all as specified and directed.
Supply and replacement of condensing coil suitable for Water Cooler of capacity 40/80,60/120,150/150 Ltrs including welding/soldering, at site complete all as spd and directed. As per existing sample.
M&L for removing burnt/defective sealed compressor unit of any make from any type and Capacity of 165 to 200 Ltrs refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing compressor sealed unit including necessary brazing work as required.new sealed compressor unit complete all as spd and directed. Make- Godrej/Videocon/Whirlpool /LG/Samsung or Equivalent .
All as per item No. 29.00 here in before but compressor suitable for refrigerator capacity of 286 to 320 Ltrs complete all as specified and directed. Make- Godrej/Videocon/Whirlpool /LG /Samsung or Equivalent .
M&L Checking the unserviceable Refrigerator of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete.
S&F only for the following items, complete all as specified and directed by Engineer in charge.:-
All as per item No.32.00 here in before but Front grill suitable for 165 to 320 ltrs capacity Refrigerator
All as per item No.32.00 here in before but Freezer suitable for 165 to 320 ltrs capacity Refrigerator
All as per item No.32.00 here in before but Relay current type and thermal over load protector suitable for compressor complete. Make: Renutrol/Voltas/LG or Equivalent.
All as per item No.32.00 here in before but Thermostat auto defrost type suitable for any make and any capacity Refrigerator Make: Danfos/IndFoss/renutrol or Equivalent .
All as per item No.32.00 here in before but Air Filter suitable for any make and any capacity Refrigerator Make:Danfos/IndFoss/renutrol or Equivalent.
All as per item No.32.00 here in before but Capillary tube including brazing work of suitable length as per existing size for refrigerator any make and any capacity. Make:Danfos/IndFoss/renutrol or Equivalent
All as per item No.32.00 here in before but for Heater Coil for refrigerator of size 165 Ltr to 320 Ltr Make: LG, Samsung, Whirlpool or equivalent.
All as per item No.32.00 here in before but of New PCB for refrigerator invertor type of size 165 Ltr to 320 Ltr as per existing sample requirement.
M&L for removing burnt/defective sealed compressor unit icluding brazing work of any make from Capacity 155 to 320 Ltr of Deep freezer by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit complete all as specified and directed at site by the Engr-in-Charge. Make-Tecumesh/Godrej/Voltas/Blue star/ whirlpool/ LG.
M&L for testing the leakage in system by charging Nitrogen Gas up to 300 PSI. Repairing the leakage spots/Joints with welding work including supply and replacement of filter pencil type copper and capillary tube of existing dia & length. Making the system leakproof vacuuming the system complete all as specified and directed at site by the Engr-in-Charge.
M&L Checking the unserviceable Deep Freezer of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department complete all as specified and directed.
S&F only for the following items, complete all as specified and directed by Engineer in charge.:-
All as per item No.36.00 here in before but Relay current type and over load protector suitable for compressor Make: Danfos/Ind Foss/renutrol or Equivalent.
All as per item No.36.00 here in before but Thermostat auto defrost type suitable for any make and any capacity Deep Freezer Make:- LG,Whirlpool or equivalent.
All as per item No.36.00 here in before but Drier filter complete set suitable for any make and any capacity Deep Freezer as per existing size.
All as per item No.36.00 here in before but Replacement of old unsv Blower motor for Deep Freezer 4x4 Make as per sample make as per existing sample requirement.
All as per item No.36.00 here in before but Capillary tube of suitable length as per existing size for Deep freezer any make and any capacity as per site requirement. Make:- Danfos/IndFoss/renutrol or Equivalent.
All as per item No.36.00 here in before but Starting relay suitable for 310/320 ltrs capacity Deep freezer Make:- as per site requirement.
All as per item No.36.00 here in before but S & F new Axial fan motor with Condenser motor (Rotary/Axial fan) suitable for any type and any capacity deep freezer complete all as specified and directed. Make: AUE/Cool Blow/Universal/ Frac master or Equivalent.
All as per item No.36.00 here in before but Starting capacitor suitable for Deep freezer suitable for any type and any capacity deep freezer. Make: Universal/Dipcon/Runcon /Usha/ Epcos/Brite or Equivalent.
Supply and replacement of old unsv copper bound Fan motor with frame legs and nut, bolts including iron blade for desert cooler 1350RPM or 1/7HP single phase 220 volt 50C/S, 375-450mm including fixing nut bolts of desert cooler and making necessary electrical connection and testing complete all as specified. Make : Khaitan or equilent
M&L for rewinding of desert cooler fan motor of 1/7HP /1/8 HP single phase 3 speed with super ennamelled copper wire of appropriate gauge with insulating material complete after removing old burnt wire including servicing change the unserviceable bush, shaft and testing after completion , complete all as specified and directed by Engr-in - charge.
S&F only for the following items, complete all as specified and directed by Engineer in charge.:-
All as per item No.39.00 here in before but Water circulating submersible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hr Make: Micra TESLA/TEXMO or Equivalent.
All as per item No.39.00 here in before but Supply and Fixing of Filter pad made out of wooden wool suitable for Air grills of desert cooler as per existing size.
All as per item No.39.00 here in before but Painting the external portion of desert cooler with 2 coat of synthetic enamel paint of Ist grade over a coat of zinc chrome primer after scarping existing painted surface and painting the interior portion of the cooler with 1 coats of anti corrosive paint and refixing all components and testing complete all as specified and directed. Make : - Asian/Berger.
All as per item No.39.00 here in before but Front panel of dimension as per existing size suitable for desert cooler of capacity 4000/5000/6000 Cum per hrs
All as per item No.39.00 here in before but Supply and replacement of base and side grill, rear/ back grill for desert cooler made out 22 gauge GI sheet (any make and any size) of desert cooler all as per site requirement.
All as per item No.39.00 here in before but PVC Flexible hose suitable for desert cooler cooling system as per existing sample requirement.
All as per item No.39.00 here in before but PVC Fan Blade suitable for 3000/4000/5000/6000 as per sample requirement.
All as per item No.39.00 here in before but Bolt, nut with washers as per site requirement.
All as per item No.39.00 here in before but PVC Connector i.e (Elbow, Tee,3 way etc)
M&L for replacement of U/S Voltage stabilizer 2 KVA to 3 KVA, input voltage range 90 volt to 220volt and output voltage 220 volt to 230 Volt AC + 2% variation of voltage complete with accessories etc. Make: As per existing sample requirement.
M&L for replacement of U/S Voltage stabilizer 04 KVA to 5KVA , input voltage range 90 volt to 220volt and output voltage 220 volt to 230 Volt AC + 2% variation of voltage complete with accessories etc As per existing sample requirement complete all as specified and directed by Engineer-in-Charge.
S&F of pressure transducer 0-18 Bar & 0-30 Bar as per site requirement complete all as specified and directed
Supply & Charging of Compressor oil 4GS as per site requirement complete all as specified and directed.
Removing and dismantling of complete compressor defective parts and replacement of defective spare parts (connecting rod bearing, pump end bearing, seal bearing, sunction read discharge read, crank shaft, piston oil and compressing rings, piston pins, DV guides,cyllinder sleeves,oil pump assembly,Thrust washer,valve plate etc.), complete overhauling complete all as specified and directed by Engineer-in-Charge as per site requirement.
Disconnecting all electrical wiring connections and removal of damaged/ unserviceable spares / parts and wiring with and including 1.0 sq mm multistranded copper wire and interlocking connections with suitable size lugs,connectors including marking numbers, cable tie, nut bolts, screws & making provn for single phase preventor & systematically cleaning and checking supply of microprocessor controller with all safety provisions of LT electric control panel board, displays, testing and commissioning for central type A/C plant, contactor and expansion valve cleaning and liquid line strainer and test leak testing and checking & set right the parameters complete all as directed by Eng-in-charge at ajmer. Make of wire-Havells or equilent
S&F of water differential switch as per site requirement complete all as specified and directed as per site requirement.
Supply of Coupling tyre as per site requirement complete all as specified and directed.
Supply and fixing chilled water sensors as per site requirement complete all as specified and directed make as per site req.
S& F of Heating strip of AC Plant complete all as specified and directed by Engineer-in-Charge make as per site requirement. 3KW, 34 cm.
M&L for pressure testing, leak repairing and Vaccumization of chiller and charging of refrigerant complete all as specified and directed by Engineer-in-Charge .
M&L for charging of Refrigerant R-22/F-22/R-410A/R-134(a) in Split/Window AC, water cooler, deep freezer and AC Plant of any capacity complete all as specified and directed by Engr-in-Charge.
Replacement of old pvc cooling tower fills and S&F new pvc fills for cooling tower as per site requirement.
Descaling the condenser (60 TR & 72 TR capacity AC Plant) with and using descaling solution. The solution will be circulated till all the scale from the tube is removed. The left cover scale will be removed by nylon brush fixed on rod circulation of fresh water through condenser till the clear water comes out from the other end and including repairs complete all as specified and directed .
Uma engineers
PD GUPTA AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .