Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC HOUSE NO 59 THILIXU VILLAGE BLOCK V PS POST DIMAPUR NAGALAND 797 112 | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹10.7 L+₹78,580 (7.92%)Rejected-Finance C O HILL HARDWARE STORE P R HILL KOHIMA NAGALAND | PHEK | NAGALAND | 797104 | L2 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | Shri Atoshe Tuccu L1 | thepfuralie zutso L2 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying cables, foundation for pole, etc and getting out in hard/dense soil complete all as specified and as directed. | 34 | Cum | 600 ₹20,400 Lowest | 610 ₹20,740 |
| 2.00 | Returning, filling in, including spreading, levelling, watering and well ramming of soil in layers n. exc 25cm thick complete all as specified and as directed. | 16 | Cum | 240 ₹3,840 Lowest | 245 ₹3,920 |
| 3.00 | Removing excavated soil to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and as directed. | 18 | Cum | 260 ₹4,680 Lowest | 265 ₹4,770 |
| 4.00 | Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to requirred thickness complete all as specified and as directed. (Note: Thickness of sand cushioning after punning down shall be measured for payment purpose) | 12 | Cum | 2,500 ₹30,000 Lowest | 2,560 ₹30,720 |
| 5.00 | Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed. | 1.2 | Per 1000 Nos | 18,000 ₹21,600 Lowest | 20,000 ₹24,000 |
| 6.00 | S &F in repair street light fitting of 60 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kVcomplete also tested for 440 Volt for 8 hour Phase to phase without any damage complete all as specified and as directed. | 19 | Each | 7,500 ₹1,42,500 Lowest | 8,500 ₹1,61,500 |
| 7.00 | S &F in repair street light fitting of 100 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kVcomplete also tested for 440 Volt for 8 hour Phase to phase without any damage and connecting up complete all as specified and as directed. | 17 | Each | 13,500 ₹2,29,500 Lowest | 14,500 ₹2,46,500 |
| 8.00 | S &F in repair flood light fitting of 90 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kVcomplete also tested for 440 Volt for 8 hour Phase to phase without any damage and connecting up complete all as specified and as directed. | 22 | Each | 10,000 ₹2,20,000 Lowest | 11,000 ₹2,42,000 |
| 9.00 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 4.0 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including taking down old unserviceable UG cable any type complete all as specified and as directed. | 200 | Rm | 400 ₹80,000 Lowest | 450 ₹90,000 |
| 10.00 | S & F in repair multicore PVC connection and testing 1.5 sqmm 3 core copper cable including necessary and connector with pole structure with all fixing and connecting accessories etc, complete all as specified and direted. | 200 | Rm | 160 ₹32,000 Lowest | 165 ₹33,000 |
Tender Value
₹9.8 L
EMD Value
₹19,600
Closing Date
6 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Zakhama
C/o 792 FPO PIN-900792 C/O 99 APO
REPAIR/MAINT OF PERIMETER LIGHTS AND SECURITY LIGHTS INCLUDING CONNECTED WORKS AT CHAKABAMA MIL STN UNDER AGE (I) ZAKHAMA
2025_MES_735397_1
8533/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chakabama C/o 99 APO
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Zakhama
₹19,600
17 Dec 2025
15 Oct 2025
8 Nov 2025
15 Oct 2025
6 Nov 2025
30 Oct 2025
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying cables, foundation for pole, etc and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming of soil in layers n. exc 25cm thick complete all as specified and as directed.
Removing excavated soil to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and as directed.
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to requirred thickness complete all as specified and as directed. (Note: Thickness of sand cushioning after punning down shall be measured for payment purpose)
Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed.
S &F in repair street light fitting of 60 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kVcomplete also tested for 440 Volt for 8 hour Phase to phase without any damage complete all as specified and as directed.
S &F in repair street light fitting of 100 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kVcomplete also tested for 440 Volt for 8 hour Phase to phase without any damage and connecting up complete all as specified and as directed.
S &F in repair flood light fitting of 90 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kVcomplete also tested for 440 Volt for 8 hour Phase to phase without any damage and connecting up complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 4.0 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including taking down old unserviceable UG cable any type complete all as specified and as directed.
S & F in repair multicore PVC connection and testing 1.5 sqmm 3 core copper cable including necessary and connector with pole structure with all fixing and connecting accessories etc, complete all as specified and direted.
Supply and fix street light panel factory febricated (CPRI type-tested) MCB TPN 63 A -01 nos, contactor TP65 A-01 no ,Astronomical timer street light control panel with accessories outdoor type including connected switch gears , cable etc and suitable sheet metal enclosure test and commissioning of 440 V , outdoor cubical type with sutaible provision of 25x3 mm angular base and vertical frame along with necessary PCC foundation and locking arrangement including taking down old one complete all as specified and directed. NOTES: The quoted rate shall be inclusive of the following (a) Suitable copper control wiring inside panel board ,cable glands ,cable lugs , supporting insulator etc. (b) The panel should be mounted min 0.30 m above the ground level. (c) Quoted rate is inclusive of angular base frame and PCC foundation earth work connected accessories. (d) Design / Drawing / bom of the panel showing the dimensions is to be obtained from manufacturer/ supplier and is to be approved from AGE(I) before placing the final order to the manufacturer. (e) Any thing missed out in the technical specification but technically required for efficient working is deemed to be included in the quoted rates. Make: Havells , cat no IHXSS0312A/ L&T / Legrand
M&L in repair for GI pipe light grade 40mm bore with all fittings laid in trenches/ walls/ floors/ poles/ road crossing with necessary coping and clamps complete all as speciffied and as directed.
M & L for cutting the existing hard standing/PCC/WBM road at a depth not less than 45 cm and 25 cm wide for passing of cable through GI pipe returning filling in complete including finishing the surfaces by providing cement concrete (1:2:4) type B2 using 40mm grade stone aggregate) upto 20cm depth,finishing to a uniform smooth surface to match the existing surface complete all as specified and directed. Note - GI pipes shall be measured and paid seprately under relevant item of this schedule.
thepfuralie zutso (BID ID -3467643)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
Tender.pdf
Tender Documents • 0.75 MB
BOQ_823493.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .